F 455, F 457, F 458. M. M. M. CAUTION - RISK OF FIRE. This product must be installed in accordance with the applicable installation code by a person familiar ...
Ceiling GENERAL PRODUCT INFORMATION: CAUTION - RISK OF FIRE This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.
This product is listed by one of the following “Nationally Recognized Testing Laboratory” These fixtures are intended to be installed utilizing NEC compliant junction boxes.
Use minimum 90°c supply conductors.
This product is suitable for damp locations. This product may be dimmed with a low voltage electronic dimmer.
1A 4
3
MOUNTING PLATE
1
MOUNTING PLATE SCREW
1
SCREW HOLE
FIXTURE BASE
FIXTURE SCREW
5
5
1
Secure the mounting plate to the junction box with two mounting plate screws.
2
Connect the fixture to a suitable ground in accordance to local electrical codes.
3
Connect the white driver wire to the neutral power line wire with a wire nut.
4
Connect the black driver wire to the hot power line wire with a wire nut.
5 1
Place the fixture base onto the mounting plate and secure it in place by screwing the fixture screws into the screw holes.
1
MISE EN GARDE - RISQUE D'INCENDIE Ce produit doit être installé selon le code d’installation pertinent , par une personne qui connaÎt bien le produit et son fonctionnement ainsi que les risques inhérents
Les fils d’alimentation doivent convenir pour 90°c.
1A 4
3
PLAQUE DE MONTAGE
1
VIS DE PLAQUE DE MONTAGE
1
TROUS DE VIS
BASE DE LUMINAIRE
VIS DE LUMINAIRE
5
5
1
Fixer la plaque de montage sur le boîte de jonction avec deux vis de montage.
2
Connecter le luminaire à un terrain approprié conformément aux codes électriques locaux.
3
Connecter le fil blanc de conducteur pour le fil de ligne à neutre avec un écrou de fil.
4
Connecter le fil noir de conducteur au fil de la ligne d'alimentation hot avec un écrou de fil.
5 1
Placez la base de luminaire sur la plaque de montage et le fixer en vissant les vis de luminaire dans les trous de vis.
2
ADVERTENCIA - RIESGO DE INCENDIO Este productor debe ser instalado segun el codigo de instalacion aplicable por una persona que conozca la constussion y el funcionamiento del producto y los riesgos que supone.
Conductores de alimentacion 90°c Min.
1A 4
3
PLACA DE MONTAJE
TORNILLO DE LA PLAQUE DE MONTAGE
1
1
AGUJERO DEL TORNILLO
BASE DE LA LÁMPARA
TORNILLO DE LA LÁMPARA
5
5
1
Fije la placa de montaje a la caja de junctura con dos tornillos de montaje.
2
Conecte la lámpara a una puesta a tierra adecuada de acuerdo a los códigos eléctricos locales.
3
Conecte el cable blanco del conductor al cable de la línea de alimentación neutra con una tuerca para cable.
4
Conecte el cable negro del conductor al cable de la línea eléctrica caliente con una tuerca para cable.
5 1
Coloque la base de la lámpara a la placa de montaje y seguro en su lugar atornillando los tornillos de la lámpara en los agujeros de los tornillos.
Port Washington, NY 11050 ... Properly secure the safety cord to the bracket on mounting back plate to temporary hang the fixture in place (FM-38934 only).
Install the glass panels by carefully sliding them into the housing and securing ... Connect the white fixture wire to the neutral power line wire with a wire nut.
Headquarters/Eastern Distribution Center. 44 Harbor Park Drive. Port Washington, NY 11050. Central Distribution Center. 1600 Distribution Ct. Lithia Springs ...
NEC junction boxes. This product is safety listed for damp locations. For a complete list of dimmers, visit out website at www.Feiss.com. CAUTION RISK OF FIRE.Termes manquants :
fixture's ground wire directly to the back plate using the green screw provided. ... PC Diffuser. Mounting Plate. Junction Box. Glass. (RPL-GLA-13114). Shade.
Connect the fixture ground wire to a suitable ground in accordance to local electrical codes. Connect the white driver wire to the neutral power line wire with a wire nut. Connect the black driver wire to the hot power line wire with a wire nut. Moun
CAUTION - RISK OF FIRE. This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved. Use minimum 90°c supply conductors. 4. 1. 1.
Coloque las tiras adhesivas dentro del marco de los parlantes. Inserte la rejilla de .... necesitará tener acceso al interior de los parlantes durante la instalación.
... côté du attache fileté de l'écrou pré-installée sur le plaque de montage. Installez l'anneau de fond abat-jour et diffuseur, puis fixez-les en place avec le fleuron.
with the construction and operation of the product and the hazards involved. Use minimum 90°c supply conductors. 4. 1. 1. 6. 7. 5. Pavé Flush Mount. 1.0. FM442.
Connect the black fixture wire to the hot power line wire with a wire nut. Align the keyed slots ... the hazards involved. Use minimum 90°c supply conductors. G. P.
These fixtures are intended to be installed utilizing compliant junction. NEC boxes. This product is safety listed for damp locations. Incandescent lamps may be ...
Secure the mounting plate to the junction box. ... Place the pipe cover, spacer, steel washer, rubber washer, shade, rubber washer, and steel washer onto the ...
44 Harbor Park Drive • Port Washington, NY 11050. Phone (516) 515.5000 • Fax (516) 515.5050. Western Distribution Center. 1750 Archibald Ave • Ontario, CA ...
... on the lamp socket for Max Wattage information. Install the shade by aligning it with the fixture base, then using the thumb screws to secure them together. 1. 2.
Connect the fixture to a suitable ground in accordance with local electrical codes. Connect the white fixture wire to the neutral power line wire with a wire nut.
Screw the lamps into the sockets. Refer to the label on the lamp socket for Max Wattage information. Install the shades by placing them over the sockets, then ...
Place the rubber washer, the shade, and large washer onto the threaded pipe (in that order), then secure them in place using a hex nut. Place the decorative cup ...
Place the fixture base over the threaded nipple and secure it in place with the cap nut. Screw the lamps into the sockets. Refer to the label on the lamp socket for ...