Direct Operated Proportional DC Valve Series D1FP Characteristics
3. Characteristics. The direct operated control valve D1FP of the nominal ... controlling of pressure and velocity. Driven by the new .... [A] 4.0 medium lag. EMC.
Characteristics The direct operated control valve D1FP of the nominal size NG06 (CETOP03) shows extremly high dynamics combined with maximum flow. First of all it is used for highest accuracy in positioning of hydraulic axis and controlling of pressure and velocity. Driven by the new patented VCD® actuator the D1FP reaches the frequency response of real servovalves. Compared with solenoid driven valves the D1FP can also be used in applications with pressure drops up to 350bar across the valve. Because of the high flow capability the D1FP can be a substitute for NG10 valves in some cases. A loss of the power supply lets the spool move in a defined position. All common input signals are available.
3
Technical features • Real servovalve dynamics (-3dB/350Hz at ±5% input signal) • No flow limit up to 350 bar pressure drop through the valve • Max. tank pressure 350 bar (with external drain port y) • High flow • Defined spool positioning in case of power supply breakdown • Onboard electronics
Directional Size Proportional VCD control DIN NG06 control valve CETOP03 NFPA D03
3 Code
Spool type
9
P Spool type
Spool Y-port position (plugged) 4) on power down 1)
Flow [l/min] at ∆p 35bar per metering edge
Zerolap E50M E50H E50F E50C E50B
40 25 12 6 3 QB = QA /2
B60M
40 / 20 Overlap 25%
E01M E01H E01F E01C E01B
E02M E02H
40 25
B32M
QB = QA /2
(other seal compound on request)
Commandsignal
Accessories
Spool/ sleeve design
Design series
Code
Connection type
0 5
6 + PE acc. EN175201-804 11 + PE acc. EN175201-804
Code
Signal
Flow direction
B E S
+/- 10V +/- 20mA 4...20mA
0...+10V -> P-A 0...+20mA -> P-A 12...20mA -> P-A
Spool pos. on power down
A 2)
QB = QA /2
40 / 20
Seal NBR
Code
40 25 12 6 3
B31M
0
N
B 2)
C 3)
40 / 20
1)
On power down the spool moves in a defined position. This cannot be guaranteed in case of single flow path on the control edge A – T resp. B – T with pressure drops above 120 bar or contamination in the hydraulic fluid.
2)
approx. 10% opening, only zero lapped spools
3)
only for overlapped spools
4)
needs to be removed at tank pressure >35 bar
Please order plugs separately. See chapter 3 accessories.
Technical Data General Design Actuation Size Mounting interface Mounting position Ambient temperature Weight Vibration resistance Hydraulic Max. operating pressure
Direct operated proportional DC valve VCD® actuator NG06/CETOP03/NFPA D03 DIN 24340 / ISO 4401 / CETOP RP121 / NFPA unrestricted [°C] -20...+50 [kg] 4.5 [g] 25 acc. DIN IEC68, part 2-6
Fluid Fluid temperature Viscosity permitted [cSt] / [mm2/s] recommended [cSt] / [mm2/s] Filtration Nominal flow at ∆p=35bar per control edge 2) [l/min] Flow maximum [l/min] Leakage at 100 bar [ml/min] Static / Dynamic Step response at 100% step 3) [ms] Frequency response (±5% signal) 3) [Hz] Hysteresis [%] Sensitivity [%] Temperature drift [%/°K] Electrical characteristics Duty ratio [%] Protection class Supply voltage/ripple [V] Current consumption max. [A] Switch-on current typical [A] Input signal Voltage [V] Impedance [kOhm] Current [mA] Impedance [Ohm] Current [mA] Impedance Differential input max. Code 0 Code 5 Enable signal (only code 5) Diagnostic signal Pre-fusing EMC Electrical connection Wiring min. Code 0 Code 5 Wiring lenght max.
3
[bar] Ports P, A, B 350 [bar] Port T max. 35, port Y max. 35 1) Hydraulic oil as per DIN 51524...535, other on request [°C] -20...+60 20...380 30...80 ISO 4406 (1999)
18/16/13 (acc. NAS 1638: 7)
3 / 6 / 12 / 25 / 40 90 (at ∆p=350bar over two control edges)
B â T with pressure drops above 120 bar or contamination in the hydraulic fluid. 2) approx. 10% opening, only zero lapped spools. 3) only for overlapped spools.
Hydraulic Controls Division ... Hydraulic. Max. operating pressure. [bar] Ports P, A, B 350, T 210. Fluid. Hydraulic oil as per DIN 51524...535, other on request.
B12 3) zerolap 2). E52. B61. QB = QA /2. ( ) flow for spool B11/B12. Code. Flow [l/min] .... If the minimal supply voltage drops below, it is internally monitored and ...
The proportional directional valves 4DP02 of the nominal size NG10 (CETOP 05) are offered under ... Kaarst, Germany. 3. Technical Data. General. Design.
Series CM. 7. Ordering Code. Schematics. The valve side is shown at the top of the symbols, the manifold side with channel designation is shown on the bottom.
ated or "at rest" condition. When downstream pressure exceeds the value set by the spring force, the control piston moves off its seat, closing off the flow path ...
Catalogue HY11-3500/UK. Parker Hannifin ... The optimum dynamics are achieved at a control pressure ... a completely factory set unit with minimum or no need.
When the valve poppet is open, the large cross-section allows high flow rates at low differential pressure. ⢠Different control ratios can be chosen with the NG6.
Pressurizing the X-port relieves the area on top of the poppet to the drain port and allows flow from B to A. The seat design of the SVLB valve series provides ...
provides shock-free unloading of the fluid, especially at high working pressure and large volumes. Connection for pilot line. Connection for pilot line. Code. RH.
Features. ⢠The direct operated, cushioned piston design results in fast response, low leakage and minimal hysteresis. ⢠Up to 5 pressure adjustment ranges are ...Missing:
Series PRDM are direct operated pressure reducing valves to regulate pressure in one area of a hydraulic circuit at a predetermined level below normal system.
The valve bodies of the Parker Manapak valve series. PRM are made of steel. ... in the valve body. ⢠Piloting results in a ... The O-rings for sealing the connecting ...
piston type valves with low hysteresis. They can be used as a P-T relief, and a T-T controlled counter balance valve. 4 pressure stages with max. pressure ...
Cracking pressure. Direct operated check valve. Design series. Seals. Nominal size. Body sealing. Code. Body sealing. 1 sealing for port A. 2 1) sealing for port ...
NBR. 5. FPM. 3) Position control for D5S08/10 only. Spring 2 or 4. Spool A and sleeve 3. Options ... AC: up to 7200, DC: up to 16000 switchings/hour. Solenoid ...
Adjustment. Throttle valve. Seal. FPM. Design series. (not required for ordering). V. Code ... V. SK-FM2-V-20. Note: The O-ring plate (with. O-rings) for sealing the.
Max. switching frequency. [1/h] 16000 (DC), 7200 (AC) .... The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm. Surface finish. NBR. BK375. 4x M5x30.