Characteristics / Ordering Code Direct operated check valves series ZRV have a cartridge type insert to provide zero leakage and high life time. The check function can be located in the P- or in the T-port.
ZRV-P02
ZRV-P02
Features • Leakage-free seat • High life time • Cracking pressure 0.5 bar • Sizes - ZRV01 - NG06 / CETOP3 - ZRV02 - NG10 / CETOP5 ZRV-P02
Technical data General Size Mounting interface
Mounting position Ambient temperature Weight Hydraulic Max. operating pressure Nominal flow Cracking pressure Fluid Fluid temperature Viscosity permitted Viscosity recommended Filtration
06 DIN 24340 A6 ISO 4401 NFPA D03 CETOP RP 121 unrestricted [°C] -20...+50 [kg] 0.7
10 DIN 24340 A10 ISO 4401 NFPA D05
2.0
[bar] 350 [l/min] 40 [bar] 0.5 Hydraulic oil as per DIN 51524...525 [°C] -20...+80 [mm2/s] 10...650 [mm2/s] 30 ISO 4406 (1999) 18/16/13 (acc. NAS 1638: 7)
100 0.5
Ordering code
ZRV Check valve, direct operated Code P T
Pressure control
Nominal size
Code 01 02
Press. control Blocked in P Blocked in T
Nominal size NG06 NG10
Ordering code details see end of chapter. ZRV_UK.INDD RH
Cracking pressure. Direct operated check valve. Design series. Seals. Nominal size. Body sealing. Code. Body sealing. 1 sealing for port A. 2 1) sealing for port ...
Features. ⢠The direct operated, cushioned piston design results in fast response, low leakage and minimal hysteresis. ⢠Up to 5 pressure adjustment ranges are ...Missing:
The proportional directional valves 4DP02 of the nominal size NG10 (CETOP 05) are offered under ... Kaarst, Germany. 3. Technical Data. General. Design.
Nominal flow. [l/min]. 150 ... Technical data. C4V10 ... Nominal size. 5. Max. pressure. 350 bar. 3. Subplate mounting. The Denison model code is avail- able for ...
Series CM. 7. Ordering Code. Schematics. The valve side is shown at the top of the symbols, the manifold side with channel designation is shown on the bottom.
NBR. 5. FPM. Pilot oil. Code. Pilot. Drain. 4. External via port X1 or X2. External. 5. External ... AC: up to 7200, DC: up to 16000 switchings/hour. Coil insulation ...
When the valve poppet is open, the large cross-section allows high flow rates at low differential pressure. ⢠Different control ratios can be chosen with the NG6.
NBR. 5. FPM. Code Solenoid voltage omit. Standard w/o vent function. G0R. 12V= G0Q ... AC: up to 7200, DC: up to 16000 switchings/hour. Coil insulation class.
Direct operated 2 way pressure compensators series. R5A can be combined with any type of fixed or adjusta- ble flow resistor (throttle) to provide a load ...