Pilot Operated Prop. Pressure Relief Valve Series R4V*P2 (Denison)
Catalogue HY11-3500/UK
Characteristics Proportional pressure relief valves series R4V*P2 are based on the mechanically adjusted series R4V. The additional proportional unit between the mechanical pilot valve and the main stage allows continuous pressure adjustment. The optimum performance can be achieved in combination with the digital amplifier module PCD00A-400.
Features • Pilot operated with manual adjustment • Continuous adjustment by proportional solenoid • 2 interfaces - L-body (R4V06-G¾", R4V10-G1¼") - T-body (R4V03-G½", R4V06-G1") • 3 pressure stages • With mechanical maximum pressure adjustment
Pilot Operated Prop. Pressure Relief Valve Series R4V*P2 (Denison)
Catalogue HY11-3500/UK
Ordering Code / Technical Data Ordering code
R4V Proportional pressure relief valve
5 Size
Code
Nominal size
03
NG10 (G½")
06
NG25 (G1" - T-body, G¾" - L-body)
10
NG32 (G1¼")
Code
Body R4V03 T-body R4V06 T-body R4V06 L-body R4V10 L-body
6 D
Max. pressure 350 bar
P2 Body
Pressure stages
Adjustment
Drain line
G0R
Proportional Solenoid pressure voltage control 12V=
A Design series
Seal
Code 1 5
Seal NBR FPM
Code 0
Drain line internal external from pilot head (Y1)
2
Code 1 3
Code Pressure stages 1 up to 105bar 3 up to 210bar 5 up to 350bar
Options
Adjustment Hand knob Acorn nut with lead seal
Technical data R4V*P2
10
General Size Mounting Mounting position Ambient temperature Weight Hydraulic Max. operating pressure Pressure stages Nominal flow Fluid Fluid temperature Viscosity permitted Viscosity recommended Filtration Electrical (prop. solenoid) Duty ratio Nominal voltage Max. current Coil resistance Protection class Power amplifier
T-body 03 (½") Threaded body unrestricted [°C] -20...+50 [kg] 5.0
L-body 06 (1")
06 (¾")
10 (1¼")
5.1
7.4
8.4
[bar] Ports A and X up to 350; Ports B and Y 30 bar [bar] 105, 210, 350 [l/min] 90 300 300 Hydraulic oil as per DIN 51524...525 [°C] -20...+80 [cSt]/[mm2/s] 20...380 [cSt]/[mm2/s] 30 ISO 4406 (1999) 18/16/13 (acc. NAS 1638: 7) [%] [V] [A] [Ohm]
600
100 12= 2.3 4 at 20°C IP65 in accordance with EN 60529 (plugged and mounted) PCD00A-400
Pilot Operated Prop. Pressure Relief Valve Series R4V*P2 (Denison)
Catalogue HY11-3500/UK
Dimensions T-body
10
NG 03 06 Ports
Body T-body T-body
B1 85 136 Function
H1 27.5 38
H2 21 28
H3 59.5 93
H4 144.5 178
H5 106.5 140
L1 53 66.5
L2 92 117.5
Port size R4V03*P2 T-body G½ " G½ "
A pressure (inlet) B tank (outlet) X1) ext. remote control or vent connection Y12) external drain 1) closed when supplied 2) port Y1 is only available at drain line (code2) external from the pilot head
Pilot Operated Prop. Pressure Relief Valve Series R4V*P2 (Denison)
Catalogue HY11-3500/UK
Dimensions L-body
10
NG 06 10 Ports
Body L-body L-body
B2 81 120.7 Function
B3 76 85.8
H6 23 31.8
H7 51 50.8
H8 81 96
H9 166 181
H10 128 143
L3 49 49.8
Port size R4V06 L-body G¾ " G¾ "
A pressure (inlet) B tank (outlet) X1) ext. remote control or vent connection Y12) external drain 1) closed when supplied 2) port Y1 is only available at drain line (code2) external from the pilot head
Features. ⢠The direct operated, cushioned piston design results in fast response, low leakage and minimal hysteresis. ⢠Up to 5 pressure adjustment ranges are ...Missing:
NBR. 5. FPM. Pilot oil. Code. Pilot. Drain. 4. External via port X1 or X2. External. 5. External ... AC: up to 7200, DC: up to 16000 switchings/hour. Coil insulation ...
The proportional directional valves 4DP02 of the nominal size NG10 (CETOP 05) are offered under ... Kaarst, Germany. 3. Technical Data. General. Design.
Cracking pressure. Direct operated check valve. Design series. Seals. Nominal size. Body sealing. Code. Body sealing. 1 sealing for port A. 2 1) sealing for port ...
NBR. 5. FPM. Code Solenoid voltage omit. Standard w/o vent function. G0R. 12V= G0Q ... AC: up to 7200, DC: up to 16000 switchings/hour. Coil insulation class.
The valve bodies of the Parker Manapak valve series. PRM are made of steel. ... in the valve body. ⢠Piloting results in a ... The O-rings for sealing the connecting ...
When the valve poppet is open, the large cross-section allows high flow rates at low differential pressure. ⢠Different control ratios can be chosen with the NG6.
piston type valves with low hysteresis. They can be used as a P-T relief, and a T-T controlled counter balance valve. 4 pressure stages with max. pressure ...
INDD CM. Catalogue HY11-3500/UK ... 2 way flow control valves series 2F1C provide pressure and viscosity ... Minimum pressure difference curves. 2F1C02.