Pilot Operated Prop. Pressure Relief Valve Series ... - Parker Hannifin

Catalogue HY11-3500/UK. Parker Hannifin GmbH & Co. KG. Hydraulic Controls Division. Kaarst, Germany ... Minimum pressure curve RE*M*W 1). R4V03.
413KB taille 104 téléchargements 432 vues
Pilot Operated Prop. Pressure Relief Valve Series R4V*P2 (Denison)

Catalogue HY11-3500/UK

Characteristics Proportional pressure relief valves series R4V*P2 are based on the mechanically adjusted series R4V. The additional proportional unit between the mechanical pilot valve and the main stage allows continuous pressure adjustment. The optimum performance can be achieved in combination with the digital amplifier module PCD00A-400.

Features • Pilot operated with manual adjustment • Continuous adjustment by proportional solenoid • 2 interfaces - L-body (R4V06-G¾", R4V10-G1¼") - T-body (R4V03-G½", R4V06-G1") • 3 pressure stages • With mechanical maximum pressure adjustment

R4V10*P2 L-body

R4V06*P2 L-body

10

R4VP2_UK.INDD RH

10-15

Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany

Pilot Operated Prop. Pressure Relief Valve Series R4V*P2 (Denison)

Catalogue HY11-3500/UK

Ordering Code / Technical Data Ordering code

R4V Proportional pressure relief valve

5 Size

Code

Nominal size

03

NG10 (G½")

06

NG25 (G1" - T-body, G¾" - L-body)

10

NG32 (G1¼")

Code

Body R4V03 T-body R4V06 T-body R4V06 L-body R4V10 L-body

6 D

Max. pressure 350 bar

P2 Body

Pressure stages

Adjustment

Drain line

G0R

Proportional Solenoid pressure voltage control 12V=

A Design series

Seal

Code 1 5

Seal NBR FPM

Code 0

Drain line internal external from pilot head (Y1)

2

Code 1 3

Code Pressure stages 1 up to 105bar 3 up to 210bar 5 up to 350bar

Options

Adjustment Hand knob Acorn nut with lead seal

Technical data R4V*P2

10

General Size Mounting Mounting position Ambient temperature Weight Hydraulic Max. operating pressure Pressure stages Nominal flow Fluid Fluid temperature Viscosity permitted Viscosity recommended Filtration Electrical (prop. solenoid) Duty ratio Nominal voltage Max. current Coil resistance Protection class Power amplifier

T-body 03 (½") Threaded body unrestricted [°C] -20...+50 [kg] 5.0

L-body 06 (1")

06 (¾")

10 (1¼")

5.1

7.4

8.4

[bar] Ports A and X up to 350; Ports B and Y 30 bar [bar] 105, 210, 350 [l/min] 90 300 300 Hydraulic oil as per DIN 51524...525 [°C] -20...+80 [cSt]/[mm2/s] 20...380 [cSt]/[mm2/s] 30 ISO 4406 (1999) 18/16/13 (acc. NAS 1638: 7) [%] [V] [A] [Ohm]

600

100 12= 2.3 4 at 20°C IP65 in accordance with EN 60529 (plugged and mounted) PCD00A-400

R4VP2_UK.INDD RH

10-16

Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany

Pilot Operated Prop. Pressure Relief Valve Series R4V*P2 (Denison)

Catalogue HY11-3500/UK

Characteristic Curves Signal/pressure curve R4V

p/Q performance curves 1) R4V03

R4V06

R4V10

Minimum pressure curve RE*M*W 1) R4V03 R4V06

R4V10

1)

10

The performance curves are measured with external drain. For internal drain the tank pressure has to be added to curve.

R4VP2_UK.INDD RH

10-17

Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany

Pilot Operated Prop. Pressure Relief Valve Series R4V*P2 (Denison)

Catalogue HY11-3500/UK

Dimensions T-body

10

NG 03 06 Ports

Body T-body T-body

B1 85 136 Function

H1 27.5 38

H2 21 28

H3 59.5 93

H4 144.5 178

H5 106.5 140

L1 53 66.5

L2 92 117.5

Port size R4V03*P2 T-body G½ " G½ "

A pressure (inlet) B tank (outlet) X1) ext. remote control or vent connection Y12) external drain 1) closed when supplied 2) port Y1 is only available at drain line (code2) external from the pilot head

R4V06*P2 T-body G1 " G1 " G¼ "

R4VP2_UK.INDD RH

10-18

Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany

Pilot Operated Prop. Pressure Relief Valve Series R4V*P2 (Denison)

Catalogue HY11-3500/UK

Dimensions L-body

10

NG 06 10 Ports

Body L-body L-body

B2 81 120.7 Function

B3 76 85.8

H6 23 31.8

H7 51 50.8

H8 81 96

H9 166 181

H10 128 143

L3 49 49.8

Port size R4V06 L-body G¾ " G¾ "

A pressure (inlet) B tank (outlet) X1) ext. remote control or vent connection Y12) external drain 1) closed when supplied 2) port Y1 is only available at drain line (code2) external from the pilot head

R4V10 L-body G1¼ " G1¼ " G¼ "

R4VP2_UK.INDD RH

10-19

Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany

Catalogue HY11-3500/UK

Notes

10

R4VP2_UK.INDD RH

10-20

Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany