CAUTION - RISK OF FIRE This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.
These fixtures are intended to be installed utilizing NEC compliant junction boxes. This product is safety listed for damp locations.
Use minimum 90°c supply conductors.
For a complete list of dimmers, visit out website at www.Feiss.com
1A MOUNTING PLATE
FIXTURE SCREW
10 8
9
10 CANOPY
4 1
DRIVER
1 6
7
STEM
1 1 3
CANOPY
PENDANT
1
Determine the height of the fixture with the provided stems and assemble them by screwing them together.
2
Secure the mounting plate to the junction box.
3
Feed the fixture wires through the stems and screw the stem assembly to the pendant.
4
Feed the fixture wires through the canopy and screw the canopy onto the stem assembly.
5
Connect the fixture to a suitable ground in accordance to local electrical codes.
6
Connect the blue driver wire to the white fixture wire with a wire nut.
7
Connect the red driver wire to the black fixture wire with a wire nut.
8
Connect the white driver wire to the neutral power line wire with a wire nut.
9
Connect the black driver wire to the hot power line wire with a wire nut.
10
Neatly place the driver and wires into the junction box and/or canopy, then place the canopy onto the mounting plate and secure it in place with the fixture screws. 1
ATTENTION : RISQUE D'INCENDIE Ce produit doit être installé conformément au code d'installation en vigueur par une personne familière avec la construction et l'exploitation du produit et les risques qu'il entraîne.
Utiliser les conducteurs d'alimentation supérieure à 90° c.
1A PLAQUE DE MONTAGE
VIS DE LUMINAIRE
10 8
9
10 DAIS
4 1
CONDUCTEUR
1 6
7
TIGE
1 1 3
DAIS
PENDENTIF
1
Déterminer la hauteur du luminaire avec les connecteurs et assembler en les vissant ensemble.
2
Fixer la plaque de montage sur le boîtier électrique avec deux vis de plaque de montage.
3
Faire passer les fils de luminaire à travers les tiges et visser l'ensemble de la tige pour le pendentif.
4
Faire passer les fils deu luminaire à travers la dais et visser le dais sur l'assemblage de la tige.
5
Connectez le luminaire à un terrain approprié conformément avec les codes électriques locaux.
6
Connectez le fil bleu de conducteur au fil blanc de luminaire avec un écrou de fil.
7
Connectez le fil rouge de conducteur au fil noir de luminaire avec un écrou de fil.
8
Connectez le fil blanc de conducteur au fil ligne neutre avec un ecrou de fil.
9
Connectez le fil noir de conducteur au fil ligne chaude avec un ecrou de fil.
10
Parfaitement placer le conducteur et le fils dans le boîte de jonction et/ou de la dais, puis déposer la dais sur la plaque de montage et fixez-le en serrant les vis de montage.
2
PRECAUCIÓN: RIESGO DE INCENDIO Este producto debe instalarse de acuerdo con el código de instalación aplicable por una persona familiarizada con la construcción y operación del producto y los riesgos que conllevan.
Utilizar conductores de suministro mínimo 90° c.
1A PLACA DE MONTAJE
10 8
9
TORNILLO DE LA LÁMPARA
10 DOSEL
4 1
CONDUCTOR
1 6
7
TALLO
1 1 3
DOSEL
COLGANTE
1
Determinar la altura de la lámpara con los tallos proporcionados y ensamblarlos atornillándolos juntos.
2
Fije la placa de montaje a la caja eléctrica.
3
Pase los cables de la lámpara a través de los tallos y atornille el tallo para el colgante.
4
Pase los cables de la lámpara a través de el dosel y atornille el dosel en el ensamble de la tallo.
5
Conecte la lámpara a una tierra apropiada de acuerdo con los códigos eléctricos locales.
6
Conectar el cable azul del conductor al cable blanco de la lámpara con tuerca para cable.
7
Conectar el cable rojo del conductor al cable negro de la lámpara con tuerca para cable.
8
Conecte el cable conductor blanco al cable neutro línea con tuerca para cable.
9
Conecte el cable conductor negro al cable de línea caliente potencia con tuerca para cable.
10
Cuidadosamente coloque el conductor y los cables en la caja eléctrica o dosel, luego colocar el dosel en la placa de montaje y asegúrelo en su lugar apretando los tornillos de la lámpara.
Determine the height of the fixture with the provided stems and assemble them by screwing them together. Secure the mounting plate to the junction box.
Secure the fixture to the post with the post screws making sure to neatly tuck in all wiring. ... Place the cover over the frame and secure it in place by screwing the finial onto the nipple ... Feiss reserves the right to ... A Generation Brands Com
Insert the diffuser into the diffuser base, place the LED assembly on top of the diffuser, and secure it to the top of the housing ... A Generation Brands Company.
44 Harbor Park Drive • Port Washington, NY 11050 ... Place the fixture over the mounting back plate and secure with mounting screws (B) and rubber gaskets ...
For slope ceiling applications, rotate swivel at the top of the stem to ensure luminaire is aiming down (Fig.3). 9. To prevent moisture from entering the outlet.
Fixer la plaque de montage sur le boîte de jonction avec deux vis de montage. ... Connectez le fil blanc de conducteur au fil ligne neutre avec un capuchon de ...
Connect the white driver wire to the neutral power line wire with a wire nut. ... Insert the glass panels into the housing and secure them using the glass panel ...
For a complete list of dimmers, visit out website at www.Feiss.com. This instruction shows a .... improvements without notification. A Generation Brands Company.
Beware of joists, water pipes and electric cables when drilling holes. 2. ... Aurora does not levy any WEEE disposal charges to its customers for affected WEEE.
44 Harbor Park Drive • Port Washington, NY 11050. Phone (516) 515.5000 • Fax (516) 515.5050. Western Distribution Center. 1750 Archibald Ave • Ontario, CA ...
NEC junction boxes. This product is safety listed for damp locations. For a complete list of dimmers, visit out website at www.Feiss.com. CAUTION RISK OF FIRE.Termes manquants :
Headquarters/Eastern Distribution Center. 44 Harbor Park Drive. Port Washington, NY 11050. Central Distribution Center. 1600 Distribution Ct. Lithia Springs ...
the circuit breaker switch(es) that control the power to the fixture or room that you are ... CAUTION When handling the fixture, do not apply pressure to the LEDs.
CAUTION: To prevent electrical shock, ensure electricity has been turned off at the circuit breaker before beginning. •. Read all instructions before installing.
Headquarters/Eastern Distribution Center. 44 Harbor Park Drive. Port Washington, NY 11050. Central Distribution Center. 1600 Distribution Ct. Lithia Springs ...
44 Harbor Park Drive. Port Washington, NY 11050. Central Distribution Center. 1600 Distribution Ct. Lithia Springs, GA 30122. Western Distribution Center.