Suntana 2 Microprozessor-Controlled Temperature ... - APPER Solaire

Running time meter and measurement of solar energy yield inimum and maximum value display of storage tank and collector temperature imitation of storage ...
531KB taille 2 téléchargements 170 vues
Suntana 2 Microprozessor-Controlled Temperature Difference Regulator Pump-to-pump or pump-to-valve selection of 2 collector systems for East/West orientation or 2 storage systems with storage priority or 2 completely seperate solar systems

untana 2

Minimum and maximum value display of storage tank and collector temperature Running time meter and measurement of solar energy yield Limitation of storage tank temperature Menu-driven LCD display

The Suntana solar thermal regulator offers everything your thermal solar system needs. The microprocessor-controlled controller monitors and controls your thermal solar systems with up to two differently orientated collector paneels and maximal two service water and buffer storage tanks. In addition to controlling the solar system the regulator also takes over important system monitoring and security functions. System parameters and measured values can be viewed and modified via a menudriven 2 x 16-char LCD display. By means of a volume meter with pulse input the solar energy of the collector panel fed into the heat storage tank can be read from the LCD display at any time. With the aid of the integrated operating hour counters both controller outputs are automatically monitored and therefore ensure increased operational safety of your solar system. The regulator has a maximum of five inputs for measuring the temperature, one digital pulse input for measuring the solar energy yield as well as two outputs for activating pumps. The use of high-quality precision temperature sensors of platinum (Pt1000) guarantees exact and lasting operation of your solar system. The regulator is supplied including four temperature sensors.

System setup: Solar system with measurement of solar energy yield

T1

T1

Storage1

P1

2 seperate solar systems

P1

Collectorfield 1

T4

T3

T5

T2

T1

V1 V1

Storage1

T2

Collectorfield 2

Storage2

T4

T2

P2

Key: T1...T5: Temperature determination V1 : Volume meter for measurement of solar energy yield P1: Solar loop pump 1 P2: Solar loop pump 2 Reversing valve R2: 3-way valve Measurement of solar energy yield insist of V1, T4, T5

T2

Two-storage solar system with 2 pumps and measurement of solar energy yield

Two-storage solar system with 2 pumps

Storage1

T3

P1

T3

Two-storage solar system with pump and 3-way valve

T1

T1

Two-storage solar system with pump, 3-way valve and measurement of solar energy yield T1

T1

T4

T4 T5 Storage2 T5

Storage1 T4

T2

Storage1

V1

T3

P1

T1

Collectorfield 1

2 collector systems for East/West orientation with 2 pumps and measurement of solar energy yield

Collectorfield 2

Collectorfield 1

P2

T4 T2

Technical data:

T3

V1 V1

Storage1

P1

Collectorfield 2

P2

Collectorfield 1

Collectorfield 1

Collectorfield 2

T3

T3

Collectorfield 2

Storage1

T4 Storge1 T4

T5 V1 V1

T2

Storager2

Collector systems for East/West orientation 3-way valve and measurement of solar energy yield T1

T3

Storage1

T4

Storage1 M T2 Reversing valve R2

Collector systems for East/West orientation 3-way valve T1

T1

P1

T5

T3

T3

P1

Storage2 T5

Reversing valve R2

P2

2 collector systems for East/West orientation with 2 pumps

Storage1 T4

P1 M T2

T3

T2

P1

P2

Storage2

Reversing valve R2 M

P1

T2

Reversing M valve R2

T5

T2

V1 V1

P1

Nominal voltage 230 Volt ( ± 15 % ), 50 Hz £ 1,0 W Own consumption 6 inputs 5 x temperature determination Precision temperature sensor PT1000 1 x pulse determination pulse counter (1...99 liter/pulse) 2 outputs R1 Triac for speed control, switching capacity max. 200 W R2 relay, switching capacity max. 800 W All outputs are protected against overload and short circuit. Adjustment ranges Turn-on temperature difference 4...17 K Turn-off temperature difference 2...15 K Display LCD-Display, 2 lines with 16 char each, menu-driven clear text display Protection IP 20 / DIN 40050 Permissible ambient temperature 0°C to + 45° C Installation wall installation Weight 490 g Casing Recycleable 3-part plastic casing Dimensions l x w x h (mm) 150 x 215 x 43 mm Temperature sensor PT1000 1,5 m silicon cable, measuring range up to 180°C Permitted by the VDE Proof- and Certification Institute under DIN EN 60730-1, DIN EN 60730-2-9

Technical Alterations can be made without prior notice. Illustrations and descriptions do not claim to be complete. - 704.354 - 04.01

Single-storage solar system