collector systems for East/West orientation or storage systems with storage priority or completely seperate solar systems. Running time meter and measurement ...
Suntana 2 Microprozessor-Controlled Temperature Difference Regulator Pump-to-pump or pump-to-valve selection of 2 collector systems for East/West orientation or 2 storage systems with storage priority or 2 completely seperate solar systems
untana 2
Minimum and maximum value display of storage tank and collector temperature Running time meter and measurement of solar energy yield Limitation of storage tank temperature Menu-driven LCD display
The Suntana solar thermal regulator offers everything your thermal solar system needs. The microprocessor-controlled controller monitors and controls your thermal solar systems with up to two differently orientated collector paneels and maximal two service water and buffer storage tanks. In addition to controlling the solar system the regulator also takes over important system monitoring and security functions. System parameters and measured values can be viewed and modified via a menudriven 2 x 16-char LCD display. By means of a volume meter with pulse input the solar energy of the collector panel fed into the heat storage tank can be read from the LCD display at any time. With the aid of the integrated operating hour counters both controller outputs are automatically monitored and therefore ensure increased operational safety of your solar system. The regulator has a maximum of five inputs for measuring the temperature, one digital pulse input for measuring the solar energy yield as well as two outputs for activating pumps. The use of high-quality precision temperature sensors of platinum (Pt1000) guarantees exact and lasting operation of your solar system. The regulator is supplied including four temperature sensors.
System setup: Solar system with measurement of solar energy yield
T1
T1
Storage1
P1
2 seperate solar systems
P1
Collectorfield 1
T4
T3
T5
T2
T1
V1 V1
Storage1
T2
Collectorfield 2
Storage2
T4
T2
P2
Key: T1...T5: Temperature determination V1 : Volume meter for measurement of solar energy yield P1: Solar loop pump 1 P2: Solar loop pump 2 Reversing valve R2: 3-way valve Measurement of solar energy yield insist of V1, T4, T5
T2
Two-storage solar system with 2 pumps and measurement of solar energy yield
Two-storage solar system with 2 pumps
Storage1
T3
P1
T3
Two-storage solar system with pump and 3-way valve
T1
T1
Two-storage solar system with pump, 3-way valve and measurement of solar energy yield T1
T1
T4
T4 T5 Storage2 T5
Storage1 T4
T2
Storage1
V1
T3
P1
T1
Collectorfield 1
2 collector systems for East/West orientation with 2 pumps and measurement of solar energy yield
Collectorfield 2
Collectorfield 1
P2
T4 T2
Technical data:
T3
V1 V1
Storage1
P1
Collectorfield 2
P2
Collectorfield 1
Collectorfield 1
Collectorfield 2
T3
T3
Collectorfield 2
Storage1
T4 Storge1 T4
T5 V1 V1
T2
Storager2
Collector systems for East/West orientation 3-way valve and measurement of solar energy yield T1
T3
Storage1
T4
Storage1 M T2 Reversing valve R2
Collector systems for East/West orientation 3-way valve T1
T1
P1
T5
T3
T3
P1
Storage2 T5
Reversing valve R2
P2
2 collector systems for East/West orientation with 2 pumps
Storage1 T4
P1 M T2
T3
T2
P1
P2
Storage2
Reversing valve R2 M
P1
T2
Reversing M valve R2
T5
T2
V1 V1
P1
Nominal voltage 230 Volt ( ± 15 % ), 50 Hz £ 1,0 W Own consumption 6 inputs 5 x temperature determination Precision temperature sensor PT1000 1 x pulse determination pulse counter (1...99 liter/pulse) 2 outputs R1 Triac for speed control, switching capacity max. 200 W R2 relay, switching capacity max. 800 W All outputs are protected against overload and short circuit. Adjustment ranges Turn-on temperature difference 4...17 K Turn-off temperature difference 2...15 K Display LCD-Display, 2 lines with 16 char each, menu-driven clear text display Protection IP 20 / DIN 40050 Permissible ambient temperature 0°C to + 45° C Installation wall installation Weight 490 g Casing Recycleable 3-part plastic casing Dimensions l x w x h (mm) 150 x 215 x 43 mm Temperature sensor PT1000 1,5 m silicon cable, measuring range up to 180°C Permitted by the VDE Proof- and Certification Institute under DIN EN 60730-1, DIN EN 60730-2-9
Technical Alterations can be made without prior notice. Illustrations and descriptions do not claim to be complete. - 704.354 - 04.01
Running time meter and measurement of solar energy yield inimum and maximum value display of storage tank and collector temperature imitation of storage ...
Full motor protection with integrated trip electronics. â. â. External control functions. Control input "Overriding Off". â. â. Control input "Overriding Min". â. â ... systems in accordance with German directive TrinkwV 2001. â ... Ele
glass transition, phase transition (crystallization), and ... the glass temperature, Tg, is related to (d7/dr)r above ... by direct reversible measurements in the melt.
From the Department of Emergency Medicine,. Medical University ... Setting: Emergency department of a tertiary care university hospital. Patients: .... admission.
1 sept. 2018 - et suppléments en vigueur et de tous les frais imputés pour l'utilisation du réseau de distribution et de transport ainsi que la contribution.
Soleil par rapport à la Terre change de 30° environ entre le solstice d'hiver et le solstice d'été. Comme la plupart des fours sont conçus pour être utilisés l'été, ...
Department of Drug Delivery Research, Johnson & Johnson Pharmaceutical Research and ... complexation, 2-hydroxypropyl-β-cyclodextrin (HPβCD), solubility.
Use the check-boxes to mark your progress. â Please read the ... IC socket. Watch the position of the notch! â R2 : 18K (1 - 8 - 0 - 2 - 1). â R7 : 1K8 (1 - 8 - 0 - 1 ...
INSPECT SWITCH CONTINUITY. (a) Using an ohmmeter, check that no continuity exists be- tween the terminal and switch body when the coolant temperature is ...
Of all of the sensing technologies, temperature sensing is the most common. ..... Although the mechanical stresses can effect long term stability, the electrical ...
Heater LED - ON when the PIC is requesting the heater to be turned ON and the ... Over Temperature Shutdown active, the corresponding heater output was ...
Temperature command to the DS1615 over the serial interface. The most recently ..... Note that if an invalid command is issued, no action is taken by the device.
Prevent dust or metallic debris from falling into the controller and cause malfunctions. DO NOT ... PID, PID programmable, Fuzzy, Self-tuning, manual, ON/OFF.