The pressure relief valve VS*06 is a direct operated spool valve for subplate mounting with internal drain to port T. The connection and function is according to ISO 6264. Function • Spool type valve • Subplate mounting according to ISO 6264 • 5 pressure stages • 2 adjustment modes • Gauge port
4
Ordering code
VS Pressure relief valve
Code 025 064 160 210 350
A Pressure Adjustment stages screw with hexagon socket
06
V
G
Nominal size
FPM Seals
Gauge port G1/4“
Lock
Design series (not required for ordering)
Code omit Z*
Pressure stages up to 25 bar up to 64 bar up to 160 bar up to 210 bar up to 350 bar
Lock Normal DIN lock
* not pictured
Technical data General Design Nominal size Interface Mounting position Ambient temperature Weight Hydraulics Max. operating pressure Pressure stages Nominal flow Fluid Fluid temperature Viscosity permitted recommended Filtration
Direct operated relief valves spool type DIN NG06 / CETOP03 / NFPA D03 Subplate mounting according to ISO 6264 unrestricted [°C] -20...+80 [kg] 1.3 [bar] Port P 350, Port T depressurized [bar] 25, 64, 160, 210, 350 [l/min] 25 Hydraulic oil according to DIN 51524...525 [°C] Recommended +30...+50, permitted -20...+70 [cSt] / [mm²/s] 20...380 [cSt] / [mm²/s] 30...50 ISO 4406 (1999); 18/16/13
The fail-safe position of the directional valve during power ... With electrical connections the protective conductor (PE W) must be connected according to the ...
a considerable effect on the service life of the hydraulic ... Drain lines are not to be crimped, and if possible, at a .... Manual override of the solenoid requires a.
2-way pressure compensators series LCM are sandwich plate valves designed for ... When the cross sectional opening of the directional valves is held steady, ...
4. The direct operated pressure relief valve series EVSA is a seated type valve for screw-in mounting. It is available in two sizes and three pressure stages.
D*FP*5. Description. Order No. IEC 61076-2-101 M12 / 4 + PE. 5004109. Description. Order No. ... to DIN 24340-A16, size NG16/CETOP07. With * marked ...
Motors. Range of application. ⢠Closed loop position and force control of linear cylin- ders and ... Optimization with integrated oscilloscope function. Flexible .... Equipping electric power systems with electronic operating equipment. HD 625 ...
Nominal flow. [l/min]. 150 ... Technical data. C4V10 ... Nominal size. 5. Max. pressure. 350 bar. 3. Subplate mounting. The Denison model code is avail- able for ...
NBR. 5. FPM. Pilot oil. Code. Pilot. Drain. 4. External via port X1 or X2. External. 5. External ... AC: up to 7200, DC: up to 16000 switchings/hour. Coil insulation ...
comb-2way-check.INDD RH. 2 Way Slip-In Cartridge Valves. Combination Examples. 2 Way Function. 2 way seat valve, flow A B. 2 way seat valve with stroke ...