2-way pressure compensators series LCM are sandwich plate valves designed for ... When the cross sectional opening of the directional valves is held steady, ...
Characteristics 2-way pressure compensators series LCM are sandwich plate valves designed for stacking beneath a proportional directional control valve with a standardised mounting pattern. The valve maintains a constant pressure differential between ports P and A or P and B across the directional valve. When the cross sectional opening of the directional valves is held steady, a constant flow rate is achieved, regardless of consumer load fluctuations. The control pressure applied to the spring side of the compensator spool is supplied from port A or B via a shuttle valve. Flow rate regulation is automatically effective in the port with the highest pressure.
Application example
Technical data Series Port size Mounting pattern Max. operating pressure Pressure differential
[bar] [bar]
LCM2 NG06 NFPA D03 CETOP 3 350 10
LCM3 NG10 NFPA D05 CETOP 5 350 10 Proportional DC valve model D31FS with 2 way pressure compensator LCM3 maintains a constant flow rate. The diagram shows the design according to code X.
7
Ordering Code
LCM Pressure compensator
Code 2 3
V
PP Size
Pilot oil Differential Control pressure connection 10 bar
Size NG06 NG10
Seal FPM
Design series
(not required for ordering)
Code Pilot oil omit internal X1) external 1) NG10 only
Dimensions LCM2
LCM3
Mounting screws: BK 403 (4 x M5 x 90) For mounting screws connected with the directional valves D1 or D31.
Mounting screws: BK 412 (4 x M6x 90) The views show the mounting surface for the directional valve.
The fail-safe position of the directional valve during power ... With electrical connections the protective conductor (PE W) must be connected according to the ...
a considerable effect on the service life of the hydraulic ... Drain lines are not to be crimped, and if possible, at a .... Manual override of the solenoid requires a.
4. The direct operated pressure relief valve series EVSA is a seated type valve for screw-in mounting. It is available in two sizes and three pressure stages.
D*FP*5. Description. Order No. IEC 61076-2-101 M12 / 4 + PE. 5004109. Description. Order No. ... to DIN 24340-A16, size NG16/CETOP07. With * marked ...
Catalogue HY11-3500/UK ... A manually adjusted pilot stage controls a seated type main stage. ... allows oil circulation from P to T at minimum pressure drop.
Motors. Range of application. ⢠Closed loop position and force control of linear cylin- ders and ... Optimization with integrated oscilloscope function. Flexible .... Equipping electric power systems with electronic operating equipment. HD 625 ...
Nominal flow. [l/min]. 150 ... Technical data. C4V10 ... Nominal size. 5. Max. pressure. 350 bar. 3. Subplate mounting. The Denison model code is avail- able for ...
NBR. 5. FPM. Pilot oil. Code. Pilot. Drain. 4. External via port X1 or X2. External. 5. External ... AC: up to 7200, DC: up to 16000 switchings/hour. Coil insulation ...