PREPARATION. 1. Terminate the power supplied to the magnetic transformer being controlled. 2. Punch out the desired knockout conduit on the transformer. 3.
INSTALLATION INSTRUCTION Photocell 9000-PCH-GY, 9000-PCR-GY IMPORTANT: Read all instructions before installing. • Read all instructions before proceeding with the installation. • WARNING: Risk of electrical shock, not for use with swimming pool or spa fixtures.’ • Place the wall switch in the “OFF” position • Do not modify or change the product in any way. This product is to be installed by a qualified electrician only. Failure to do so will void the warranty and may result in serious injury and/or damage to the transformer.
IMPORTANTE: Lea todas las instrucciones antes de instalar. • No conecte este temporizador en un cable de extensión u otro adaptador de corriente. Conecte directamente a una toma eléctrica. • No conecte el contador a los aparatos que contienen • elementos de calefacción (de aparatos de cocina, calentadores, planchas, etc.) • El fallo del temporizador para apagar dicho dispositivo puede provocar un sobrecalentamiento y un posible incendio. • No conecte este temporizador si está húmedo. • No limpie este temporizador cuando está enchufado int. • No exceder los valores máximos del temporizador. • Posible riesgo de descarga: Mantener fuera del alcance de los niños.
IMPORTANT: Lisez toutes les instructions avant de l’installer. • Ne branchez pas ce temporisateur dans une rallonge ou un autre adaptateur électrique. Brancher directement dans une prise électrique. • Ne pas relier cette minuterie pour les appareils qui contiennent • éléments de chauffage (appareils de cuisson, chauffe, un fer à repasser, etc.) • L’échec de l’horloge pour éteindre tel dispositif peut entraîner une surchauffe et un incendie. • Ne branchez pas cette minuterie si elle est mouillée. • Ne nettoyez pas ce temporisateur quand il est branché int. • Ne pas dépasser les évaluations maximales de la minuterie. • Risque d’électrocution: Conserver hors de la portée des enfants.
THIS INSTRUCTION APPLIES TO THE MODELS BELOW:
9000-PCH-GY
9000-PCR-GY
SPECIFICATION Input: 120VAC Max Load: 600W Sensitivity: 0.5 - 1fc on / 8 - 15fc off Application Location: Dry or Wet locations Anti-interference Delay: 30 seconds
Headquarters/Eastern Distribution Center 44 Harbor Park Drive Port Washington, NY 11050
Central Distribution Center 1600 Distribution Ct Lithia Springs, GA 30122
Knockout
ON
COM
12V 13V 14V 15V
Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. January 21, 2016 3:47 PM 1
INSTALLATION INSTRUCTION Photocell 9000-PCH-GY, 9000-PCR-GY On - Board Installation 9000-PCH-GY FOR ON-BOARD INSTALLATION 1.
Unscrew and remove the mounting nut from the photocell.
2.
With the photocell outside the transformer, thread the quick connector and wires through the knockout.
3.
Replace the mounting nut and fasten the photocell to the transformer.
4.
Plug the quick connector into the transformer.
5.
Adjust the photocell to the desired position and resupply power to the magnetic transformer
Photocell
Knockout Mounting Nut
FOR REMOTE INSTALLATION 1.
Uncrew and remove mounting nut 2 from the waterproof plug.
2.
With the photocell outside the transformer, thread the quick connector and wires through the knockout.
Remote Installation 9000-PCR-GY
Waterproof Plug Photocell
3.
Replace mounting nut 2 and fasten the waterproof plug to the transformer.
4.
Using the L-Bracket and appropriate mounting screws for the desired application, mount the L-Bracket to secure the photocell in desired location.
5.
Plug the quick connector into the transformer.
6.
Adjust the photocell to the desired position and resupply power to the magnetic transformer
Mounting Nut 1 L-Bracket Mounting Nut 2
`
Note: After intially powering the photocell, please allow 1-2 minutes for it to fully configure.
WARNING •
Make sure the photocell is not affected by the light from surrounding fixtures. This could affect its performance.
•
Potential shock hazard: Keep out of reach of children.
Headquarters/Eastern Distribution Center 44 Harbor Park Drive Port Washington, NY 11050
Central Distribution Center 1600 Distribution Ct Lithia Springs, GA 30122
Western Distribution Center 1750 Archibald Avenue Ontario, CA 91760
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. January 21, 2016 3:47 PM 2
A) Recessed Mounting. NOTE: The back plate is not needed for recessed mounting and may be discarded. 1. Cut a 3 1/4â diameter hole in the surface. 2. Feed the fixture wires through the hole, and connect the wires to a 24V transformer. 3. Compress t
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous ... space that you are working on. WARNING: ...
Système est destiné à être installé par un électricien qualifié en conformité avec ... of our products at any time as part of the company's continuous improvement ...
Do not substitute any parts, leave parts out, or use any parts that are ... of our products at any time as part of the company's continuous improvement program.
from the fixture through the wire slot in the stake. STEP 2: 5. Cut the power supply wire from the transformer at the location of the fixture. 6. Separate the power ...
DECEMBER 2018 waclighting.com. Phone (800) ... 1. Shut off the power at the circuit breaker and remove existing fixture, including the mounting hardware. 2.
(ie moisture-proof polyurethane). Important! Ensure you do not cut through the toekick below. Important! Ensure you do not cut through the toekick below.
4 mai 2016 - WARNING: This product contains chemicals known to the State of California to cause cancer, birth defects and/or other reproductive harm. Thoroughly wash hands after ... Lire les instructions avec attention et couper l'électricité au nive
15 janv. 2003 - ends of Plaster Frame to prevent lateral movement of Plaster Frame. ..... Le cadre en plâtre (2) et le joint (25) doivent toucher le plafond (23).
2e vidéo. 1. jeune homme/femme. 2. éclairé par son écran. 3. zoom/travelling : voit reflet dans yeux. 4. contemplation. 5. regarde film couleur. 3e vidéo. 1. couple.
44 Harbor Park Drive ... Connect the driver input/output wire to junction box wires as shown in Fig. 2, making sure that all wire connectors (D1) are secured.
VEHICLE LIFT LOCATIONS . .... Electric components . ..... Turbo control system preparation. ..... Before connecting the power wiring to the battery, check the ...
space that you are working on. WARNING: Risk of electric shock ... The Mounting Stake requires approximately a one (1) square foot hole to facilitate installation. The excavated should be approximately 14” deep, depending on your local code ...
Headquarters/Eastern Distribution Center. 44 Harbor Park Drive. Port Washington, NY 11050. Central Distribution Center. 1600 Distribution Ct. Lithia Springs ...
44 Harbor Park Drive • Port Washington, NY 11050. Phone (516) ... Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch ”OFF”.
... company's continuous improvement program. MAy, 2014 ... junction box (F1) using the junction box screws (B1). The side of the mounting plate marked “GND”.
MAy, 2014. INSTALLATION INSTRUCTION. Elemental - dwelLED ... (F1) using the junction box screws (B1).The side of the mounting plate marked “GND” must ...
To eliminate the risk of burns or fire by reaching over the .... Specified Rating of Power Supply. Cord Kit and Circuit. Protection. 120/240 Volts. 120/208 Volts.