SUNRISE TELECOM
The Datacom/ DDS Module is part of a family of plug-in modules for the SunSet MTT® and xDSL test sets
Datacom/DDS Module SSxDSL-9
Data Sheet The SSxDSL-9 Datacom/DDS Module, part of the SunSet Modular Test Toolkit (MTT) family of products, is a rugged, battery-operated handheld test solution for WAN/data, Frame Relay, and DDS service verification. The module is designed to assist technicians in bringing up new data communication service and troubleshooting the existing data network fast and effectively. The powerful test module can be used for all your testing requirements including, DTE/DCE emulation for end-to-end testing of data networks, bidirectional monitoring for a greater level of troubleshooting for data networks, FOX testing for Frame Relay CIR verification, and Frame Relay Ping testing for checking link connectivity.
features
applications
Datacom
CSU/DSU CPE Mode
• DTE/DCE emulation • Bidirectional monitoring with Y-adapter
DSU/CSU Chan
nel B
• V.35, RS232, RS449, RS530, X.21 • Data rates from 2400 bps to 2.048 Mbps
ank
OCU
-DP
Central Office
Customer Premises
• Bit error rate testing with stress patterns • Control lead status monitor for CTS, RTS, DSR, DTR • Received data display
DTE Emulation DTE
DTE
• Frame relay UNI/NNI testing DCE
DDS 4-Wire
DCE
• CSU/DSU emulation • Bit error rate testing on a primary channel
DCE Emulation DCE
• Loopback testing • Received data display
DTE
benefits • Lightweight
Datacom Monitoring Datacom Monitor
• Flexible modular design • Eliminates the need for multiple instruments • Intuitive and easy-to-use • Cost-effective and future-proof
CSU
/DSU
CPE/Router
datacom specifications Supports V.35, X.21/V.11, RS232/V.24, RS449/V.36, RS530 interfaces Test modes: DTE Emulation, DCE Emulation, Bidirectional monitoring Connector: SCSI port with adapter cables
Operation Modes DTE Emulation • Point-to-point or point-to-loopback BERT • Control and analyze datacom control leads DCE Emulation • Point-to-point BERT • Control and analyze datacom control leads Datacom Monitoring • Bidirectional monitoring with Y-adapter cable • Monitor control leads, frequency
DTE/DCE Emulation
Test rates V.35, X.21, RS449, RS530: 2.4, 4.8, 9.6, 14.4, 19.2, 28.8, 38.4, 48 kbit/s, Nx56 kbit/s, Nx64 kbit/s, where N=1 to 32 RS232 Sync: 2.4, 4.8, 9.6, 14.4, 19.2, 28.8, 38.4, 48, 56, 64, 128 kbit/s RS232 Async: 2.4, 4,8, 9.6, 14.4, 19.2, 28.8, 38.4, 57.6 kbit/s Test patterns Synchronous rates: QRS, 215-1, 220-1, 223-1, 2047, 511, 63, 1-8, 1-16, 3-24, All 1s, All 0s, Alt 10, FOX, DDS-1 to DDS-6 Asynchronous rates: 2047, 511, 63, All 1s, All 0s, Alt 10, 1-8, 1-16, 3-24, FOX Error injection: 1 bit error Control transmit datacom leads, including RL and LL
Measurements
Bit error/G.821 Error count and rate ITU-T G.821 Analysis: ES, %ES, SES, %SES, UAS, %UAS, EFS, %EFS, AS, %AS Data loss, data loss seconds, pattern loss, pattern loss seconds Datacom interface analysis Change of state of control leads is displayed and recorded: RTS, CTS, DTR, DSR, DCD, RL, LL, C, I Transmit control leads (selectable on/off) View received data Propagation delay Measure propagation delay in microseconds and UIs (Unit Intervals) Maximum delay measurement (at 2.048 Mbit/s): 8 seconds Interfaces: X.21, V.35, RS449, RS530, RS232 Sync
Frame Relay Basic (SWxDSL-9FRA)
LMI standards: ITU-T Q.933, ANSI T1.617, LMI (DLCI 1023, GOF Vendors), NO LMI Modes: UNI DTE, UNI DCE Interfaces: X.21, V.35, RS449, RS530, RS232 Sync Rates: Nx56 kbit/s, Nx64 kbit/s, where N =1 to 32
SSxDSL-9 Datacom/DDS Module
LMI Analysis Settings: T391 Status Inquiry, T392 Status, N391 Full Status Polling, N392 Error Threshold, N393 Monitor Events Results: Link OK Total, Link Errored Total, Timeout Error, Response Sequence Number, Wrong Message PVC status: New, Active, or Inactive DLCI indication (keep the status for up to 60 DLCI) PING Test Settings: DLCI Header length (2/3/4 bytes), DLCI Value, Local IP @, Destination IP address, Network Layer Protocol Identifier (NLPID: IP or SNAPIP), Timeout, Number of PINGs Results: Number of PINGs, Number of PINGs sent, PING status (Received, Unreached, Errored), Round Trip Time (Current, Average, Maximum, Minimum) InARP support Conforms to RFC2390 (IETF) Settings: Mode [Timed (selectable), Manual Request, No InARP], Timeout (selectable) InARP statistics: InARP requests sent, InARP response received, InARP response Timeout, InARP requests received, InARP response sent, last IP address assigned IP encapsulation conforms to RFC1490 specification Echo PING: Echo/response to PING request to local IP address – Results: Total PING request received, IP address of PING requestor, Number of PING requested by IP address timestamped FOX Test Settings: DLCI Header length (2/3/4 bytes), DLCI Value, CIR, Frame length (Nx64 bytes N =1 to 64), Forward Explicit Congestion Notification (FECN), Backward Explicit Congestion Notification (BECN), Discard Eligibility (DE) Results: PVC Status, Current Rate, Errored Frames, RSN Error, SSN Error, Frame Check Sequence (FCS) Error, Count of Frame Received with FECN, with BECN, with DE, Count of transmit frames, Count of received frames Statistics Analysis Bidirectional monitoring via Y-cable Selectable short frame length, long frame length Frame relay performance: Avg/Max/Min Utilization (%), Avg/Max/ Min Throughout (%), Avg/Max/Min Frame/Sec Frame relay statistics: Avg octet, Total frame, FECN frames, BECN frames, DE frames, Short frames, Long frames, Aborted frame, FCS errors DLCI analysis: Total active DLCI count, Active DLCI listing (up to 100 DLCI) DLCI statistics: Avg octet, Total frames, FECN frames, BECN frames, DE frames, Short frames, Long frames, Aborted frames, FCS errors
Frame Relay NNI (SWxDSL-9FRNNI)
Requires SWxDSL-9FRA LMI standards: ITU-T Q.933, ANSI T1.617, LMI (DLCI 1023, GOF Vendors), NO LMI Modes: NNI USER, NNI NETWORK Rates, LMI Analysis, PING Test, FOX Test, Statistic Analysis - as described in Frame Relay Basic section
DDS 4-Wire Specifications
Product description
Test modes: CSU/DSU Emulation Signal: Bipolar return to zero with alternate mark inversion Input impedance, Term: 135Ω Primary channel conforms to AT&T PUB 62310 Rates: 2400, 4800, 9600, 19200, 56000, 64000 bit/s Connector: 8-pin modular RJ-48
Module size (WxLxH): 5.0 x 3.5 x 0.9 in (12.6 x 9 x 2.2 cm) Operating temperature: 32˚ to 122˚F (0˚ to 50˚C) Storage temperature: -4˚ to 158˚F (-20˚ to 70˚C) Humidity: 5% to 85% noncondensing
Operation Mode CSU/DSU CPE Mode • BERT testing at the DDS-4W interface • Test primary channels • Respond to DSU/CSU loop codes
Test Pattern Generator
Test patterns: 2047, 511, 63, 215-1, 220-1, 223-1, QRS, DDS-2 to DDS6, 55DLY, 55OCT, All 1s, All 0s, Alt 10, 1-8, 1-16, 3-24 Error injection: 1 bit error
Measurements
Frequency, LOSS, LOFS, EXZS, OOS, OOFS, BPVs, FBEs Bit error/G.821 Error count and rate ITU-T G.821 Analysis: ES, %ES, SES, %SES, UAS, %UAS, EFS, %EFS, AS, %AS, DGRM, %DGRM View received data
ORDERING INFORMATION SSxDSL-9 SWxDSL-9FRA SWxDSL-9FRNNI
Datacom/DDS Module Testing at both Datacom and DDS-4W interfaces Frame Relay Basic Frame Relay NNI [Requires SWxDSL-9FRA]
Recommended Accessories SSDCOM-DCC SSDCOM-DCY SS253 SS254 SS255 SS262-B SS267
Datacom Adapters Package Includes datacom adapters SS253, SS254, SS255, SS262-B, and SS267 Datacom Adapters Y Package Includes datacom adapters SS253, SS253Y, SS254, SS254Y, SS255, SS255Y, SS262-B, SS267, SS267Y X.21 DTE/DCE Adapter Set RS232 DTE/DCE Adapter Set RS449 DTE/DCE Adapter Set RS530 DTE/DCE Adapter Set V.35 DTE/DCE Adapter Set
Loopback Testing
Transmit: Latching DSU/CSU Internal loopback: Manual or auto-respond to DSU/CSU command
Status/Alarm Indicators
O
0
90
38
IS
R
LE E TE C O M N C.
SA AU CAPITAL DE 381 123 EUROS – TVA : FR 00 722 063 534 - R.C.S. NANTERRE B 722 063 534 - SIRET 72206353400043 - CODE APE 516 J
IS
,I
ELEXO - Téléphone : 01 41 22 10 00 - Fax : 01 41 22 10 01 -
[email protected]
SUN
Dual-color LEDs (on SunSet xDSL/MTT) Current status and alarm history conditions for: Signal, Error, Pattern sync, Bit Error
01 - A6
© 2006 Sunrise Telecom Incorporated. All rights reserved. Specifications subject to change without notice. All product and company names are trademarks of their respective corporations. Sunrise Telecom San Jose, Modena, and Taiwan facilities are ISO 9001 certified. Do not reproduce, redistribute, or repost without written permission from Sunrise Telecom. REV.A00 October 2006