Folic Acid by LCMS With Minimized Sample Prep & Increased Sensitivity Method Conditions Column: Catalog No.: Dimensions: Solvents:
Gradient:
Post Tme: Flow Rate: Samples:
Please note that folic acid sample was prepared in solvent A only as opposite to samples of other acids which are prepared in 50% mixture of solvents A and B. When the sample of folic acid was prepared in 50% A+50%B the MS signal was lower.
Notes: Deficiency of folic acid (vitamin B9 ) is associated with several chronic diseases (for example macrocytic anaemia, psychiatric disorders, neutral tube defects in newborns, cancer, Alzheimer’s disease and cardiovascular disease in adults [1]; thus accurate assessment of folate status has become important in the clinical setting, in epidemiological studies in clinical and research laboratories. FA cannot be synthesized by mammalian cells and therefore must be supplied with diet. It is very important to establish highly sensitive methods for the quantitative determination of trace amounts of this vitamin. [1]. B.C. Nelson, K.E. Sharpless, L.C. Sander; J. Chromatogr. A, 1135 (2006) 203-211
For more information visit www.MTC-USA.com
Cat. No. 70000-15P-2
Cogent Diamond Hydride™ 4µm, 100Å. 70000-15P-2 2.1mm x 150mm A: DI water + 10 mM ammonium acetate B: 90% acetonitrile/10% DI water/10 mM ammonium acetate. pH = 7 adjusted using ammonia Time (min) %B 0.00 100 5.00 90 9.00 50 10.00 100 5 min. 0.4 mL/min. Sample stock solution was made in Solvent A at a concentration of 2.0 mg/L. Sample for analysis was made by diluting the stock with Solvent A, to which 0.1% ammonia was added. Sample final concentration was 0.2 mg/L.
Detection:
ESI – neg - Agilent 6210 MSD TOF mass spectrometer.
Discussion A sensitive and reliable method was developed for the determination of folic acid (FA) and can be used in many applications including the complex sample matrices without the solid-phase extraction clean-up. Since the method uses LC-MS (negative-ion) it provides fantastic sensitivity as well as great selectivity. The use of chelating agents or high concentration of salts in the mobile phase or ion pair reagents (non MS compatible) are not required as in older methods for FA analysis. The LOQ is dramatically better than existing methods with UV detection. When this methodology is used very fast equilibration between gradients is observed as well. Excellent precision was achieved using the presented method. Twenty consecutive injections resulted in (%RSD = 0.26).
The upper chromatogram is the initial separation, ... conditions that would hydrolyze other reversed phases. See next page for ... silica in reversed phase.
Description. APP A44. APPLICA. TION. NOTES. Method Conditions. Column: ... retention higher percentages of water in the mobile phase can be used. The diminished hydrophobicity is shown in Table 1. For more information visit www.
as base) bound to a ribose or deoxyribose sugar. Examples of these include cytidine, uridine, adenosine, guanosine, thymidine and inosine. Nucleosides can ...
Discussion. The polar compound, Metformin, and the nonpolar compound. Glyburide, can be retained on the same stationary phase (see A. & B), utilizing the ...
40018-75P. Cogent Bidentate⢠C18 HPLC Column, 4µm \,100A 4.6mm x 75mm. Cat. ... Solvent A: 100% DI water + ... 1mg of the compound dissolved in 1 mL.
for melamine: - Agilent 6210 MSD TOF mass spectrometer. Note: When an instrument with ... Use of LC-MS detection eliminates the need for derivatization (as is ...
Mass Spec: Atmospheric Pressure. Chemical Ionization in positive mode: APCI+ Single Ion Monitoring. Discussion. Two proprietary compounds, which are ...
Cholesterol⢠HPLC columns, peaks ETES and ESTN are resolved with polarity-based, Reverse Phase, ACN as the organic modifier. ⢠With other C18 columns, ...
This active pharmaceutical ingredient was separated from related compounds in a real life pharmaceutical preparation. Note the excellent peak shape and the ...
Cogent Diamond Hydride⢠HPLC Column, 100à , 4µm, 2.1 x 150mm. Cat. No. ... The analysis of succinic acid is mostly done using gas chromatography. (GC) ...
functions, reduction of cholesterol level and reduction of the risk of cancer and the mprovement of digestion/absorption of food ingredients such as minerals.
Cogent Silica-C⢠HPLC Column, 100à , 4µm, 4.6 x 75 mm. Cat. No. Description ... determination of amino acids in many types of samples. Ordinary columns ...
Cogent Bidentate C18 HPLC Column, 100à , 4µm, 4.6 x 75 mm, Standard End Fittings. Cat. No. ... refraction indices between solvent A and solvent B in gradient ...
69069-Q20. Cogent Qx2⢠Column for LC-MS, 2.1 ID x 20 mm, PEEK & Titanium housing, ... Mass Spec: Atmospheric Pressure. Chemical Ionization in positive.
determination can be used for diagnosis of galactosemia in newborn babies [1-3]. Literature: [1]. Ji-Seon Jeong, Ha-Jeong Kwon, Hye-Ran Yoon, Yong-Moon ...
In contrast when a market leading HILIC column was used under the same conditions, the efficiency dropped by more than 30% over this same range of flow ...
Mass Spec: Atmospheric Pressure. Chemical Ionization in the. Positive mode: APCI+. Discussion: Major Peaks. Table below: Major peaks in mass spectra of ...