technical data - Klíma-S Bt

management system in order to help protect human health and the ... Electrical Specifications . .... Quantity. 1. Motor. Model. 2YC63BXD#C. Type. Hermetically sealed swing compressor ... Control. Expansion valve(electronic type). Nr of Circuits. 1. Refrigerant Oil. Type .... The integrated heating capacity and power input, is ...
3MB taille 14 téléchargements 60 vues
EEDEN08-720

technical data

Altherma

ERHQ006-008AD EKHBH/X008AA ERHQ011-016AA EKHBH/X016AB EKHWS(U) EKSOL

Altherma ERHQ006-008AD EKHBH/X008AA ERHQ011-016AA EKHBH/X016AB EKHWS(U) EKSOL

Daikin’s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to its close involvement in environmental issues. For several years Daikin has had the intention to become a leader in the provision of products that have limited impact on the environment. This challenge demands the eco design and development of a wide range of products and an energy management system, resulting in energy conservation and a reduction of waste.

ISO14001 assures an effective environmental management system in order to help protect human health and the environment from potential impact of our activities, products and services and to assist in maintaining and improving the quality of the environment.

Daikin Europe N.V. is approved by LRQA for its Quality Management System in accordance with the ISO9001 standard. ISO9001 pertains to quality assurance regarding design, development, manufacturing as well as to services related to the product.

“The present publication is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this publication to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, In the broadest sense, arising from or related to the use and/or interpretation of this publication. All content is copyrighted by Daikin Europe N.V..”

Naamloze Vennootschap Zandvoordestraat 300 B-8400 Ostend, Belgium www.daikin.eu BTW: BE 0412 120 336 RPR Oostende

EEDEN0 8 - 7 2 0

EEDEN08-720 - 02/2008 Printed in Belgium by Goekint Graphics Copyright © Daikin

Daikin units comply with the European regulations that guarantee the safety of the product.

EEDEN08-720

technical data Altherma

ERHQ006-008AD EKHBH/X008AA ERHQ011-016AA EKHBH/X016AB EKHWS(U) EKSOL

• • R-410A • ALTHERMA

rA e0 h1 t4 l- RA

Heating only

Heat pump 4

• Altherma •

EEDEN08-720

technical data Altherma

Part 1/3: ERHQ006-008AD EKHBH/X008AA

• Outdoor units • R-410A • ERHQ006-008AD

TABLE OF CONTENTS ERHQ006-008AD

1

Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

2

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Nominal Capacity and Nominal Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

3

Capacity tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Heating/ Cooling capacity tables

4

12

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Dimensional drawing & centre of gravity . . . . . . . . . . . . . . . . . . . . . . . 13 Dimensional drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Centre of gravity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

13 14

5

Piping diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

6

Wiring diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Wiring diagram

7

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Sound data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Sound pressure spectrum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

• Altherma • Outdoor units

17

7

• Outdoor units • R-410A • ERHQ006-008AD

1 D iA n8 0u 0 a - r m 6 o rA0 o e0 dh1Q t4H uRl- EA•OR

1



Features Cost effective alternative to a fossil fuel boiler



Easy to install

Low energy bills and low CO2 emissions



Total solution for year round comfort

1

8

• Altherma • Outdoor units

• Outdoor units • R-410A • ERHQ006-008AD

2

Specifications

2-1 NOMINAL CAPACITY AND NOMINAL INPUT Indoor Units Condition 1

Heating capacity Heating PI

Condition 2

ERHQ006AD

ERHQ007AD

ERHQ008AD

EKHBH008AA

EKHBH008AA

EKHBH008AA

Minimum

kW

4.36

4.36

4.36

Nominal

kW

5.75

6.84

8.43

Maximum

kW

7.45

8.79

9.58

Nominal

kW

1.26

1.58

2.08 4.05

COP

Nominal

4.56

4.34

Heating

Minimum

kW

3.87

3.87

3.87

Nominal

kW

5.03

6.10

7.64

Maximum

kW

6.68

7.98

8.76

Heating PI

Nominal

kW

1.58

1.95

2.54

COP

Nominal

3.18

3.13

3.00

Notes

Condition 1: cooling Ta 35°C - LWE 18°C ( DT = 5°C ) - heating Ta DB/WB 7°C/6°C - LWC 35°C ( DT = 5°C )

Notes

Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C ) - heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )

2-1 NOMINAL CAPACITY AND NOMINAL INPUT Indoor Units Condition 1

Heating capacity

Cooling capacity

Condition 2

Minimum

kW

ERHQ006AD

ERHQ007AD

ERHQ008AD

EKHBX008AA

EKHBX008AA

EKHBX008AA

4.36

4.36

4.36

Nominal

kW

5.75

6.84

8.43

Maximum

kW

7.45

8.79

9.58

Minimum

kW

4.82

4.82

4.82

Nominal

kW

7.20

8.16

8.37

Maximum

kW

7.20

8.50

8.91

Heating PI

Nominal

kW

1.26

1.58

2.08

Cooling PI

Nominal

kW

2.27

2.78

2.97

COP

Nominal

4.56

4.34

4.05

EER

Nominal

3.17

2.94

2.82

Heating

Minimum

kW

3.87

3.87

3.87

Nominal

kW

5.03

6.10

7.64

Maximum

kW

6.68

7.98

8.76

Minimum

kW

3.67

3.67

3.67

Nominal

kW

5.12

5.86

6.08

Cooling

Maximum

kW

5.12

6.13

7.10

Heating PI

Nominal

kW

1.58

1.95

2.54

Cooling PI

Nominal

kW

2.16

2.59

2.75

COP

Nominal

3.18

3.13

3.00

EER

Nominal

2.37

2.26

2.21

Notes

Condition 1: cooling Ta 35°C - LWE 18°C ( DT = 5°C ) - heating Ta DB/WB 7°C/6°C - LWC 35°C ( DT = 5°C )

Notes

Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C ) - heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )

2-2 TECHNICAL SPECIFICATIONS Casing

Colour

Dimensions

Unit

ERHQ006AD

Weight Packing

ERHQ008AD

Polyester painted galvanised steel Height

mm

Width

mm

797 960

Depth

mm

390 735

Height

mm

Width

mm

825

Depth

mm

300

Unit

kg

56

Packed Unit

kg

61

Material

EPS

Material

Carton

Weight

2

Ivory white

Material

Packing

ERHQ007AD

1

kg

• Altherma • Outdoor units

5

9

• Outdoor units • R-410A • ERHQ006-008AD

2

1

Specifications

2-2 TECHNICAL SPECIFICATIONS Heat Exchanger Specifications

2

Length

ERHQ006AD

845

mm

1.8

Nr of Rows Fin Pitch Nr of Stages

32 Hi-Xa(8)

Type

WF fin

Treatment Fan

Anti-corrosion treatment (PE)

Type

Propeller

Quantity Motor

1 Quantity Output

Compressor

1 W

53

Quantity Motor

1 Model

2YC63BXD#C

Type Operation Range

Sound Level (nominal)

Hermetically sealed swing compressor

Motor Output

W

Min

°CWB

Max

°CWB

25

Cooling

Min

°CDB

10

Max

°CDB

43

Sanitary water

Min

°CDB

-20

Max

°CDB

Sound Power

dBA

61

61

62

Sound Pressure

dBA

48

48

49

Sound Power

dBA

63

63

63

Sound Pressure

dBA

48

48

50

Heating

Heating Cooling

Refrigerant

Type kg

Control Type

Piping Connections

Liquid

Type

Flare connection mm

Type

6.35 Flare connection

mm

Quantity

15.9 1

Type Piping Length

1.7 1

Diameter (OD) Drain

43

FVC50K Diameter (OD)

Gas

-20

Expansion valve(electronic type)

Nr of Circuits Refrigerant Oil

1,920

R-410A

Charge

Socket

Diameter (OD)

mm

Minimum

m

3

Maximum

m

30

Additional Refrigerant Charge

kg/m

Installation Maximum height difference

m

18

0.02>10m 20

Defrost Method

Reverse cycle

Defrost Control

Sensor for outdoor heat exchanger temperature

Capacity Control Method

Inverter controlled

Standard Accessories

Installation manual

Standard Accessories

10

ERHQ008AD

2

Tube type Fin

ERHQ007AD

mm

Item Quantity

1

Item

Drain plug

Quantity

1

Notes

See operation range drawing

Notes

The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information.

• Altherma • Outdoor units

• Outdoor units • R-410A • ERHQ006-008AD

2

Specifications

2-3 ELECTRICAL SPECIFICATIONS Power Supply

V3

Phase

1~

Frequency

Hz

50

Voltage

V

230

Starting current Maximum running Current

Wiring Connections

ERHQ007AD

Name

Voltage Range Current

ERHQ006AD

Minimum

V

-10%

Maximum

V

+10%

Heating

A

11

Cooling

A

11

Heating

A

18

Cooling

A

16.25

Minimum Ssc value

kVA

Recommended fuses

A

1 2

Equipment complying with EN/IEC 61000-3-12 20

For power supply Quantity

3

For connection with indoor

Quantity

4

Remark

Included earth wiring

• Altherma • Outdoor units

ERHQ008AD

11

• Outdoor units • R-410A • ERHQ006-008AD

3

Capacity tables

3-1

Heating/ Cooling capacity tables

COOLING

1

Model

3 006

007

008

Tamb (°C) LWE (°C) 7 11 13 16 20 7 11 13 16 20 7 11 13 16 20

20 CC 6.01 6.81 7.23 7.88 8.80 7.15 8.09 8.57 9.33 10.4 8.24 9.26 9.79 10.6 11.7

25 PI 1.56 1.57 1.57 1.56 1.55 2.05 2.09 2.11 2.13 2.16 2.43 2.49 2.52 2.57 2.63

CC 5.73 6.50 6.90 7.54 8.42 6.84 7.73 8.20 8.92 9.9 7.90 8.87 9.38 10.17 11.3

30 PI 1.75 1.77 1.78 1.78 1.79 2.28 2.34 2.36 2.40 2.44 2.68 2.76 2.80 2.86 2.94

CC 5.43 6.17 6.56 7.17 8.03 6.50 7.34 7.79 8.49 9.48 7.52 8.45 8.93 9.69 10.75

35 PI 1.95 1.98 2.00 2.01 2.03 2.52 2.59 2.63 2.68 2.73 2.94 3.05 3.10 3.17 3.26

CC 5.12 5.83 6.20 6.79 7.63 6.13 6.94 7.36 8.03 8.99 7.10 7.79 8.14 8.68 9.39

40 PI 2.16 2.21 2.23 2.26 2.29 2.77 2.87 2.91 2.97 3.04 3.23 3.31 3.36 3.41 3.48

CC 4.80 5.30 5.56 5.95 6.48 5.35 5.84 6.09 6.46 6.96 5.68 6.12 6.34 6.67 7.09

43 PI 2.39 2.32 2.28 2.22 2.13 2.68 2.62 2.59 2.53 2.44 2.86 2.80 2.77 2.71 2.61

CC 4.59 4.98 5.18 5.46 5.82 4.89 5.21 5.36 5.57 5.82 4.87 5.18 5.33 5.55 5.80

PI 2.53 2.38 2.30 2.18 1.99 2.59 2.43 2.34 2.20 1.99 2.59 2.43 2.35 2.20 1.99

HEATING (Peak values)

Model

006

007

008

LWC Tamb -15 -10 -7 -2 2 7 -15 -10 -7 -2 2 7 -15 -10 -7 -2 2 7

30 HC 3.93 4.65 5.14 6.06 6.89 8.03 4.87 5.67 6.21 7.23 8.14 9.40 5.42 6.27 6.84 7.92 8.9 10.2

35 PI 1.48 1.52 1.54 1.57 1.57 1.57 1.82 1.88 1.91 1.95 1.97 1.98 2.06 2.13 2.17 2.22 2.26 2.28

HC 3.67 4.32 4.77 5.62 6.38 7.45 4.62 5.34 5.83 6.77 7.61 8.79 5.16 5.93 6.46 7.45 8.35 9.58

40 PI 1.59 1.65 1.68 1.72 1.74 1.75 1.94 2.02 2.07 2.13 2.16 2.19 2.19 2.29 2.34 2.41 2.46 2.51

HC 3.47 4.07 4.49 5.28 6.00 7.00 4.43 5.09 5.55 6.42 7.21 8.32 4.97 5.68 6.17 7.10 7.93 9.10

45 PI 1.71 1.79 1.83 1.88 1.91 1.94 2.08 2.18 2.24 2.32 2.37 2.42 2.34 2.46 2.53 2.62 2.69 2.76

HC 3.33 3.89 4.28 5.03 5.72 6.68 4.30 4.92 5.35 6.17 6.92 7.98 4.86 5.51 5.97 6.85 7.65 8.76

50 PI 1.84 1.94 1.99 2.06 2.11 2.15 2.23 2.36 2.42 2.52 2.59 2.66 2.51 2.65 2.73 2.85 2.93 3.02

HC 3.25 3.78 4.15 4.87 5.53 6.47 4.24 4.82 5.23 6.02 6.74 7.78 4.80 5.42 5.86 6.70 7.47 8.56

PI 1.99 2.10 2.16 2.25 2.31 2.37 2.40 2.55 2.63 2.75 2.83 2.92 2.70 2.86 2.95 3.10 3.20 3.31

HEATING (integrated values*)

Model

006

007

008

LWC Tamb -15 -10 -7 -2 2 7 -15 -10 -7 -2 2 7 -15 -10 -7 -2 2 7

30 HC 3.50 4.14 4.52 5.27 5.92 8.03 4.34 5.04 5.46 6.29 7.00 9.40 4.82 5.58 6.02 6.89 7.6 10.2

35 PI 1.40 1.45 1.45 1.46 1.45 1.57 1.73 1.79 1.80 1.81 1.81 1.98 1.96 2.03 2.04 2.07 2.08 2.28

HC 3.27 3.85 4.20 4.89 5.49 7.45 4.11 4.75 5.13 5.89 6.55 8.79 4.59 5.28 5.69 6.48 7.18 9.58

40 PI 1.51 1.56 1.58 1.60 1.60 1.75 1.85 1.92 1.94 1.98 1.99 2.19 2.08 2.17 2.20 2.25 2.27 2.51

HC 3.09 3.62 3.95 4.59 5.16 7.00 3.94 4.53 4.88 5.59 6.20 8.32 4.43 5.06 5.43 6.17 6.82 9.10

45 PI 1.62 1.70 1.72 1.75 1.76 1.94 1.98 2.07 2.10 2.15 2.18 2.42 2.23 2.34 2.37 2.44 2.47 2.76

HC 2.97 3.46 3.77 4.38 4.92 6.68 3.83 4.38 4.71 5.37 5.96 7.98 4.32 4.91 5.26 5.96 6.58 8.76

SYMBOLS CC HC PI LWE LWC Tamb

12

50 PI 1.75 1.84 1.87 1.92 1.94 2.15 2.12 2.24 2.28 2.35 2.38 2.66 2.39 2.52 2.57 2.65 2.70 3.02

HC 2.89 3.36 3.65 4.24 4.76 6.47 3.77 4.29 4.60 5.23 5.80 7.78 4.27 4.82 5.15 5.83 6.43 8.56

PI 1.89 2.00 2.03 2.10 2.13 2.37 2.28 2.42 2.47 2.56 2.61 2.92 2.56 2.72 2.78 2.88 2.94 3.31

* The integrated heating capacity and power input, is the average heating capacity and power input during 1 cycle. (from end of defrost till end of the next defrost).

3TW57782-1

NOTES

: Cooling capacity at maximum operating frequency, measured acc. Eurovent 6/C/003-2006 (kW) : Heating capacity at maximum operating frequency, measured acc. Eurovent 6/C/003-2006 (kW) : Power input (kW) : Leaving Water Evaporator temperature (°C) : Leaving Water Condensor temperature (°C) : Ambient temperature (°C) RH=85%

• Altherma • Outdoor units

1

2

3

Cooling capacity Capacity is according to Eurovent rating standard 6/C/003-2006 and valid for chilled water range Dt = 3∼8°C Heating capacity Capacity is according to Eurovent rating standard 6/C/003-2006 and valid for chilled water range Dt = 3∼8°C Power input Power input is total input according to Eurovent rating standard 6/C/003-2006

• Outdoor units • R-410A • ERHQ006-008AD

4

Dimensional drawing & centre of gravity

4-1

Dimensional drawing unit (mm)

ERHQ006-008 AD Drain outlet (I.D. J 15.9 hose for connection)

4

Wall height on air outlet side = less than 1200

Minimum space for air passage

1

In case of removing stop valve cover 4 x holes for anchor bolts (M8 or M10)

Name plate Brand name label

Wiring inlet

Terminal strip with earth terminal

Outdoor air temperature thermistor

Liquid stop valve (J6.4 CuT) Service port

• Altherma • Outdoor units

Gas stop valve (J15.9 CuT)

3D060289

13

• Outdoor units • R-410A • ERHQ006-008AD

1

4

Dimensional drawing & centre of gravity

4-2

Centre of gravity

ERHQ006-008 AD

4

The position of foundation bolt 4D042258L

14

• Altherma • Outdoor units

• Outdoor units • R-410A • ERHQ006-008AD

5

Piping diagram

ERHQ006-008AD

1

Outdoor unit Heat exchanger

5

Outdoor air temperature thermistor

Capillary tube 1

Capillary tube 2 Capillary tube 3

Heat exchanger thermistor

Muffler with filter

Refrigerant flow Cooling Heating

Capillary tube 4

Filter Motor operated valve

Propeller fan

Filter Four way valve on : heating

Muffler with filter

Field piping

Muffler Liquid stop valve

Muffler Field piping Discharge pipe thermistor

Compressor

Accumulator

Gas stop valve with service port

3D052750B

• Altherma • Outdoor units

15

• Outdoor units • R-410A • ERHQ006-008AD

1

6

Wiring diagram

6-1

Wiring diagram

ERHQ006-008AD

6 Power supply

To indoor unit

Sheet metal

Indoor

g Field wiring

(outdoor) (discharge) (Condenser) Outdoor Z1C∼Z7C X1M, X2M Y1E V2, V3, V5, V9, V100 SA2 FU1, FU2, FU3: AC1, AC2 U, V, W, X11A, X12A E1, E2 HR1, HR2

16

: Ferrite core : Terminal strip : Electronic expansion valve coil : Varistor : Surge arrester : Fuse

: Connector

MRM10, MRM20 MRC/W R1T∼R3T S2∼S102 LEDA L N SW1 SW4 M1C M1F L1R

: Magnetic relay : Thermistor : Connector : Pilot lamp : Live : Neutral : Forced operation on/off switch SW (SW1) : Local setting SW (SW4) : Compressor motors : Fan motor : Reactor

• Altherma • Outdoor units

Q1L PM1 PCB1,2 Y1R Sheet metal

: Overload protector : Power module : Printed circuit board : Reversing solenoide valve coil : Terminal strip fixed plate

3D052296E

• Outdoor units • R-410A • ERHQ006-008AD

7

Sound data

7-1

Sound pressure spectrum ERHQ007AD Heating

3TW57557-2

Octave band center frequency (Hz)

2 3 4

Data is valid at free field condition (measured in a semi-anachoic room) dB(A) = A-weighted sound power level (A-scale according to IEC) Reference acoustic pressure 0dB = 20μPa If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections.

1

Coil Microphone

2 3 4

Location of microphone

Coil Microphone

Location of microphone

Sound pressure level (dB) Octave band center frequency (Hz)

3TW57557-1

Data is valid at free field condition (measured in a semi-anachoic room) dB(A) = A-weighted sound power level (A-scale according to IEC) Reference acoustic pressure 0dB = 20μPa If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections.

Octave band center frequency (Hz)

NOTES

NOTES

3 4

Data is valid at free field condition (measured in a semi-anachoic room) dB(A) = A-weighted sound power level (A-scale according to IEC) Reference acoustic pressure 0dB = 20μPa If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections.

ERHQ006AD Cooling

Sound pressure level (dB)

3TW57557-2

2

Octave band center frequency (Hz)

NOTES

ERHQ008AD Heating

1

7

3TW57557-2

NOTES 1

1

Sound pressure level (dB)

Sound pressure level (dB)

ERHQ006AD Heating

1 Coil Microphone

2 3 4

Location of microphone

• Altherma • Outdoor units

Data is valid at free field condition (measured in a semi-anachoic room) dB(A) = A-weighted sound power level (A-scale according to IEC) Reference acoustic pressure 0dB = 20μPa If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections.

Coil Microphone

Location of microphone

17

• Outdoor units • R-410A • ERHQ006-008AD

7-1

Sound pressure spectrum

ERHQ007AD Cooling

ERHQ008AD Cooling Sound pressure level (dB)

7

Sound data

Sound pressure level (dB)

1

7

3TW57557-1

Octave band center frequency (Hz)

3TW57557-1

NOTES 1 2 3 4

Data is valid at free field condition (measured in a semi-anachoic room) dB(A) = A-weighted sound power level (A-scale according to IEC) Reference acoustic pressure 0dB = 20μPa If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections.

1 Coil Microphone

2 3 4

Location of microphone

18

Octave band center frequency (Hz)

NOTES

• Altherma • Outdoor units

Data is valid at free field condition (measured in a semi-anachoic room) dB(A) = A-weighted sound power level (A-scale according to IEC) Reference acoustic pressure 0dB = 20μPa If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections.

Coil Microphone

Location of microphone

• Indoor units • R-410A • EKHBH(X)008AA

TABLE OF CONTENTS EKHBH(X)008AA

1

Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

2

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

21

Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

21 24

3

Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

26

4

Dimensional drawing & centre of gravity . . . . . . . . . . . . . . . . . . . . . . . 27 Dimensional drawing

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

5

Piping diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

6

Wiring diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 Wiring diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . External connection diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

29

7

Operation range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

32

8

Hydraulic performance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Static pressure drop unit

• Altherma • Indoor units

31

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

19

• Indoor units • R-410A • EKHBH(X)008AA

1 A T A I8 0N 0U a ) m X R rA( O e0H O h1B Dt4H NKl- E•AIR

1



Features Cost effective alternative to a fossil fuel boiler



Easy to install

Low energy bills and low CO2 emissions



Total solution for year round comfort

1

20

• Altherma • Indoor units

• Indoor units • R-410A • EKHBH(X)008AA

2 2-1

Specifications TECHNICAL SPECIFICATIONS

EKHBH008AA

Outdoor units W

230

Colour Packing

Unit

Weight

Packing

Epoxy polyester painted galvanised steel Height

mm

Width

mm

660

Depth

mm

610

1225

922

Height(1)

mm

Width

mm

502

Depth

mm

361

Machine weight

kg

50

Gross Weight

kg

65

Material

EPS

Material

Wood

Material

Carton

Material

PP (straps)

Weight Main components

Pump

kg

10

Type

Water cooled

Nr. of speed Nominal ESP unit

3 Heating

kPa

Cooling

kPa

Power input Water side Heat exchanger

W

49

49 51

130

Type

Brazed plate

Qty

1

Water volume

l

Water flow rate Min.

l/min

Water flow rate No

Heating (3)

l/min

Cooling (2)

l/min

0.67 12 16.5

16.5 14.7

Insulation material Expansion vessel Water filter

Polyurethane foam

Volume

l

Max. water pressure

bar

10 3

Pre pressure

bar

1

Diameter perforations

mm

1

Material Water circuit

Brass

Piping connections diameter (7)

inch

G 1 (MALE)

Piping

inch

1-1/4"

Safety valve

bar

3

Manometer

Yes

Drain valve / Fill valve

Yes

Shut off valve

Yes

Air purge valve

Yes

Total water volume (6)

l

5.5

Refrigerant Circuit

Gas side diameter

mm

15.9

Liquid side diameter

mm

6.35

Sound Level

Sound Pressure (4)

dBA

28

Sound Power (8)

dBA

42

Ambient

Operation range

Waterside

Heating

°C

Cooling

°C

Heating (5)

°C

Cooling

°C

Outdoor units

-20~25

-20~25 10~43

15~50

15~50 5~22 ERHQ007AD

Nominal input (Indoor only) Casing

2

RAL9010

Material Dimensions

1

ERHQ006AD

Nominal input (Indoor only) Casing

EKHBX008AA

W

230

Colour

RAL9010

Material

Epoxy polyester painted galvanised steel

• Altherma • Indoor units

21

• Indoor units • R-410A • EKHBH(X)008AA

2 2-1

1

Specifications TECHNICAL SPECIFICATIONS

Dimensions

Packing

2 Unit

Weight Packing

EKHBH008AA

Height

mm

Width

mm

1225 660

Depth

mm

610

Height(1)

mm

922

Width

mm

502

Depth

mm

361

Machine weight

kg

50

Gross Weight

kg

65

Material

EPS

Material

Wood

Material

Carton

Material

PP (straps)

Weight Main components Pump

kg

10

Type

Water cooled

Nr. of speed

Water side Heat exchanger

3

Nominal ESP Heating unit Cooling

kPa

Power input

W

45

Expansion vessel

49 130

Type

Brazed plate

Qty

1

Water volume

l

Water flow rate Min.

l/min

Water flow rate Nom.

Heating (3)

l/min

Cooling (2)

l/min

0.67 12 19.6

16.8 Polyurethane foam

l

10

Max. water pressure

bar

3

Pre pressure

bar

1

mm

1

Material

Brass

Piping connections diameter (7)

inch

G 1 (MALE)

Piping

inch

1-1/4"

Safety valve

bar

3

Manometer

Yes

Drain valve / Fill valve

Yes

Shut off valve

Yes

Air purge valve

Yes

Total water volume (6) Refrigerant Circuit Gas side diameter

Operation range

l

5.5

mm

15.9 6.35

Liquid side diameter

mm

Sound Pressure (4)

dBA

28

Sound Power (8)

dBA

42

Ambient Waterside

Heating

°C

Cooling

°C

Heating (5)

°C

Cooling

°C

-20~25

-20~25

15~50

15~50

10~43 5~22

Outdoor units

ERHQ008AD

Nominal input (Indoor only) Casing

Colour

Dimensions

Packing

W

230 RAL9010

Material

Unit

22

19.6

Volume

Water filter Diameter perforations

Sound Level

45

kPa

Insulation material

Water circuit

EKHBX008AA

Epoxy polyester painted galvanised steel Height

mm

1225

Width

mm

660

Depth

mm

610

Height(1)

mm

922

Width

mm

502

Depth

mm

361

• Altherma • Indoor units

• Indoor units • R-410A • EKHBH(X)008AA

2 2-1

Specifications TECHNICAL SPECIFICATIONS

Weight Packing

EKHBH008AA

Machine weight

kg

50

Gross Weight

kg

65

Material Material

Wood

Material

Carton kg

10

Type

Water cooled

Nr. of speed Nominal ESP unit

3 Heating

kPa

Cooling

kPa

Power input Water side Heat exchanger

38

38 48

W

130

Type

Brazed plate

Qty

1

Water volume

l

Water flow rate Min.

l/min

Water flow rate Nom.

Heating (3)

l/min

Cooling (2)

l/min

0.67 12 24.1

24.1 17.4

Insulation material Expansion vessel Water filter

Polyurethane foam

Volume

l

Max. water pressure

bar

10 3

Pre pressure

bar

1

Diameter perforations

mm

1

Material Water circuit

Brass

Piping connections diameter (7)

inch

G 1 (MALE)

Piping

inch

1-1/4"

Safety valve

bar

3

Manometer

Yes

Drain valve / Fill valve

Yes

Shut off valve

Yes

Air purge valve

Yes

Total water volume (6)

l

5.5

Refrigerant Circuit

Gas side diameter

mm

15.9

Liquid side diameter

mm

6.35

Sound Level

Sound Pressure (4)

dBA

28

Sound Power (8)

dBA

42

Ambient

Operation range

Waterside

2

PP (straps)

Weight Pump

1

EPS

Material Main components

EKHBX008AA

Heating

°C

Cooling

°C

Heating (5)

°C

Cooling

°C

Notes

-20~25

-20~25

15~50

15~50

10~43 5~22 (1) With option kit EKHBDP installed: Height=936mm

Notes

(2) Tamb 35°C - LWE 7°C (DT=5°C)

Notes

(3) DB/WB 7°C/6°C-LWC 35°C(DT=5°C)

Notes

(4) The sound pressure level is measured via a microphone at 1m from the unit. It is a relative value, depending on the distance and acoustic environment. The sound pressure level mentioned is valid for pump medium speed.

Notes

(5) 15°C-25°C: BUH only, no Heatpump operation=during commissioning.

Notes

(6) Including piping+PHE+backup heater/excluding expansion vessel.

Notes

(7) Value mentioned is connection after ball valves. Connection at unit is G1 1/2 female

Notes

(8) DB/WB 7°C/6°C-LWC 35°C(DT=5°C), medium pump speed

• Altherma • Indoor units

23

• Indoor units • R-410A • EKHBH(X)008AA

2

1

2-2

Specifications

ELECTRICAL SPECIFICATIONS

Electric heater

2

Power Supply

Phase Hz

50

Voltage

V

230

Current

Running Current

A

Voltage Range

Minimum

+10% Quantity of wires Type of wires

6V3 Phase

1~

Frequency

Hz

50

Voltage

V

230

Current

Running Current

A

Voltage Range

Minimum

26 -10%

Maximum

+10% Quantity of wires Type of wires

3G Select diameter and type according to national and local regulations

Type

6WN Phase

3~

Frequency

Hz

50

Voltage

V

400

Current

Running Current

A

Voltage Range

Minimum

+10% Quantity of wires Type of wires

4G Select diameter and type according to national and local regulations

Type Power Supply

8.7 -10%

Maximum

Wiring For power Connections supply backup heater

6T1 Phase

3~

Frequency

Hz

50

Voltage

V

230

Current

Running Current

A

Voltage Range

Minimum

+10% Quantity of wires Type of wires

4G Select diameter and type according to national and local regulations

Type Power Supply

15.1 -10%

Maximum

Wiring For power Connections supply backup heater

9WN Phase

3~

Frequency

Hz

50

Voltage

V

400

Current

Running Current

A

Voltage Range

Minimum

13 -10%

Maximum

+10%

Wiring For power Connections supply backup heater

24

3G Select diameter and type according to national and local regulations

Type

Power Supply

Electric heater

13 -10%

Maximum

Wiring For power Connections supply backup heater

Electric heater

1~

Frequency

Power Supply

Electric heater

EKHBX008AA

3V3

Wiring For power Connections supply backup heater Electric heater

EKHBH008AA

Type

Quantity of wires Type of wires

• Altherma • Indoor units

4G Select diameter and type according to national and local regulations

• Indoor units • R-410A • EKHBH(X)008AA

2

2-2

Specifications

ELECTRICAL SPECIFICATIONS

Electric heater

Power Supply

9T1

1

3~

2

EKHBH008AA

Type Phase Frequency

Hz

EKHBX008AA

50

Voltage

V

230

Current

Running Current

A

22.6

Voltage Range

Minimum

-10%

Maximum

+10%

Wiring For power Connections supply backup heater

Quantity of wires Type of wires

Wiring Connections Connection type

4G Select diameter and type according to national and local regulations

For power supply connection to Optional Warm Water Tank + Q2L

Quantity of wires

3G

Type of wires

Select diameter and type according to national and local regulations For more details of the voltage range and current refer to installation manual EKHBH/ X008AA*

Connection type

For connection with R5T

Quantity of wires

Wire included in option EKHWS*

Type of wires

Wire included in option EKHWS*

Connection type

For connection with A3P

Quantity of wires

Depends on thermostat type, refer to installation manual EKHBH/X008AA*

Type of wires

Select diameter and type according to national and local regulations Voltage: 230V/Maximum current: 100mA/Minimum 0,75 mm²

Connection type

For connection with M2S

Quantity of wires

3G

Type of wires

Select diameter and type according to national and local regulations Voltage: 230V/Maximum current: 100mA/Minimum 0,75 mm²

Connection type

For connection with M3S

Quantity of wires

3G or 4G

Type of wires

Select diameter and type according to national and local regulations Voltage: 230V/Maximum current: 100mA/Minimum 0,75 mm²

• Altherma • Indoor units

25

• Indoor units • R-410A • EKHBH(X)008AA

3

Options

Factory mounted optional equipment for EKHB(H/X)008AA**

1

Reference

Description Heating only model EKHBH008A... Reversible model EKHBX008A...

A3V3

3V3

Back up heater 3kW 1∼230 V

V

V





















6V3

Back up heater 6kW 1∼230 V





V

V

















6W1

Back up heater 6kW 3∼400 V









V

V













6T1

Back up heater 6kW 3∼230 V













V

V









9W1

Back up heater 9kW 3∼400 V

















V

V





9T1

Back up heater 9kW 3∼230 V





















V

V

3

A6V3 A3V3

A6V3

A6T1

A6V3

A6WN

A9WN A6T1

A9T1 A9WN

A9T1

Outdoor combination table for EKHB(H/X)008AA**

ERHQ006ADV3

ERHQ007ADV3

ERHQ008ADV3

EKHBH008AA*

Heating only indoor unit

V

V

V

EKHBX008AA*

Reversible indoor unit

V

V

V

ERHQ006ADV3

ERHQ007ADV3

ERHQ008ADV3

V

V

V

Kit availability for ERHQ006AD*

EKBPHT16

Bottom plate heater (1)

Kit availability for EKHB(H/X)008AA*

Reference

Description Heating only model EKHBH008A... Reversible model EKHBX008A...

A3V3

A6V3

EKHWS150A3V3

Domestic hot water tank 150l 1-230V

V

V

EKHWS200A3V3

Domestic hot water tank 200l 1-230V

V

EKHWS300A3V3

Domestic hot water tank 300l 1-230V

V

EKHWS200A3Z2

Domestic hot water tank 200l 2-400V

EKHWS300A3Z2

A3V3

A6WN

A6T1

A6V3

A6WN

V

V

V (*) V (*)

V

V

V

V

V

V









V

Domestic hot water tank 300l 2-400V









V

EKHWSU150A3V3

Domestic hot water tank 150l 1-230V

V

V

V

V

EKHWSU200A3V3

Domestic hot water tank 200l 1-230V

V

V

V

V

EKHWSU300A3V3

Domestic hot water tank 300l 1-230V

V

V

V

V

EKHBDP

Option kit for condensate free cooling operation



V



V



EKRP1HB

Digital I/O PCB (2)

V

V

V

V

V

A9WN

A9T1

A6T1

A9WN

V

V

V (*) V (*)

V

A9T1 V

V (*) V (*)

V

V

V (*) V (*)

V

V

V (*) V (*)

V

V

V (*) V (*)

V

V

V





V

V





V





V

V





V (*) V (*)

V

V

V (*) V (*)

V

V

V (*) V (*)

V

V

V (*) V (*)

V

V

V (*) V (*)

V

V

V (*) V (*)

V

V

V



V



V



V

V

V

V

V

V

V

V

(*) If neutral line is available

Kit available for EKHWS*

Reference

Description EKHWS... EKHWSU...

15A3V3

200A3V3/Z2 300A3V3/Z2 150A3V3

200A3V3

EKUHWA

Option kit for UK EKHWSU150-300V3







V

V

300A3V3 V

EKSOLHWAV1

Solarkit (3)

V

V

V

V

V

V

EKWBSWW150

Wall bracket for EKSWW150V3

V





V





Remarks: Other combinations than mentioned in this option TW are not guaranteed. (1) Heater tape that can be fixed on the bottom plate to prevent ice formation. (2) Address card that provides two additional output connections (remote alarm and remote ON/OFF signalisation). In EKSOLHWAV1, the same digital I/O PCB as for EKRP1HB is already included. 3TW57789-2C (3) Kit to be mounted on domestic hot water tank that provides connection to solar panels for additional water heating.

26

• Altherma • Indoor units

• Indoor units • R-410A • EKHBH(X)008AA

4

Dimensional drawing & centre of gravity

4-1

Dimensional drawing

EKHBH008AA

1

FIXATION

4

Service door (Closed) 361 (Open) 553 G 1 (Male)

Dimensions wallbracket

Minimum space for service & ventilation

Min. 150

Min. 200

Center of gravity j 1 Pump + switch for speed setting j 2 Remocon j 3 Water IN connection G 1 1/2 (female) j 4 Water OUT connection G 1 1/2 (female) j 5 Power supply intake (+ domestic hot water tank) j 6 Air purge j 7 Expansion vessel+j 7A nipple+j 7B Drain j 8 Blow off valve j 9 Blow off drain (flexible hose J20) j 10 Pressure gauge j 11 Water filter j 12 Suction pipe connection J15.9 flare connection j 13 Liquid pipe connection J6.35 flare connection j 14 Shut off valves with drain/fill valve (accessory delivered with unit) j 15 Holes for fixation j 16 Switchbox terminals j 17 Switchbox terminals option domestic hot water tank j 18 Wallbracket

3TW57784-1A

EKHBX008AA FIXATION

Service door (Closed) 361 (Open) 553 G 1 (Male)

Dimensions wallbracket

Minimum space for service & ventilation

Min. 150

Min. 200

Center of gravity j 1 Pump + switch for speed setting j 2 Remocon j 3 Water IN connection G 1 1/2 (female) j 4 Water OUT connection G 1 1/2 (female) j 5 Power supply intake (+ domestic hot water tank) j 6 Air purge j 7 Expansion vessel+j 7A nipple+j 7B Drain j 8 Blow off valve j 9 Blow off drain (flexible hose J20) j 10 Pressure gauge j 11 Water filter j 12 Suction pipe connection J15.9 flare connection j 13 Liquid pipe connection J6.35 flare connection j 14 Shut off valves with drain/fill valve (accessory delivered with unit) j 15 Holes for fixation j 16 Switchbox terminals j 17 Switchbox terminals option domestic hot water tank j 18 Wallbracket

3TW57784-2A

• Altherma • Indoor units

27

• Indoor units • R-410A • EKHBH(X)008AA

5

1

Piping diagram

EKHBH(X)008AA R4T R3T R2T R1T

5

Water side

Inlet water thermistor Refrigerant liquid side thermistor Outlet water backup heater thermistor Outlet water heat-exchanger thermistor

Field installation Filter Inlet Shut off valve

Refrigerant side

Safety valve Drain valve

Pressure gauge

Drain

Expansion vessel Cooling (EKHBX) Heating (EKHBX + EKHBH)

Option backup heater Drain valve

Field installation

Air purge

Flowswitch

Pump

Outlet Shut off valve

Overview Electric heater body Evaporator Condensor

Outdoor unit

Refr. out Refr. in

Water inlet Refrigerant side

Water side

Refr. in Water outlet Refr. out

O Check valve L Flare connection M Screw connection N Flange connection Z Pinched pipe PSpinned pipe

28

• Altherma • Indoor units

3TW56715-1

• Indoor units • R-410A • EKHBH(X)008AA

6

Wiring diagram

6-1

Wiring diagram

EKHBH(X)008AA3V3

1

Only for EKSOLHWAV1 Option

Power supply 230V 1N∼50Hz

Solar pump connection

Outdoor unit

>> See note 2
See note 2
See note 2
See note 2
See note 2
See note 2
See note 2
See note 2
typical 3 to 4 persons usage pattern. High Daily demand up to 550 l -> 4 to 6 persons usage pattern.

(2) Heat-up time: Definition: Heat-up time The time required to reheat the domestic hot water tank to 55°C after tapping a certain volume of hot water at 40°C. note: changing the field settings (see installation manual) can influence the heat-up time.

Tank 150L 200L 300L

Heat-up time for 150 L (bath) 60 60 50

Setpoint temp. (°C) 55 55 55

Heat-up time for 50 L (shower) 45 40 30

Conditions for testing: Ta = 7°CDB / 6°CWB, Troom = 20°C, Tstart = 10°C, outdoor unit type: ERYQ007

(3) Efficiency of sanitary hot water production: In the ALTHERMA by Daikin system both the heat-pump and the electric booster heater supply the energy to produce sanitary hot water. The higher the portion of energy supplied by the heat-pump, the more energy efficient the system is. Lowering the setpoint temperature increases the portion of energy supplied by the heat-pump and thus the efficiency of the system.

Heat-pump portion

Definition: Heat-pump portion Percentage of energy supplied by the heat-pump in the total energy need for sanitary hot water.

Setpoint temp. (°C) Conditions:

Real life condition Outdoor temperature Room temperature Outdoor unit type Tank type Field settings

Simulation of a daily usage based upon ′medium′ usage pattern. 7°CDB / 6°CWB 20°CDB ERYQ007 200l Default field settings (see installation manual).

4TW57839-1

70

• Altherma • Domestic hot water tank

• Domestic hot water tank • DOMESTIC HOT WATER TANK • EKHWS

4

Dimensional drawing & centre of gravity

4-1

Dimensional drawing

3

EKHWS j 1 Water mains in female 3/4’’ BSP j 2 Water mains out female 3/4’’ BSP j 3 Thermistor connection j 4 Flow (from EKHB(H/X)*) female 3/4’’ BSP j 5 Return (to EKHB(H/X)*) female 3/4’’ BSP j 6 Switchbox j 7 Thermal protector j 8 Anode j 9 Cable entry power, booster heater and thermal protection cable j 10 Re-circulation connection female 3/4’’ BSP j 11 Cable entry from EKHB(H/X)* (see EKSOLHWAV1) j 12 Cable entry (to EKSOLHWAV1) j 13 Thermistor connection (See EKSOLHWAV1)

Required service space around the tank

1

3 4

3TW57834-1

EKHWSU Water connections kit

Water connections

j 1 j 2 j 3 j 4 j 5 j 6 j 7 j 8

Water IN (cold) Water OUT (hot) Flow from EKHB(H/X)* Return to EKHB(H/X)* Temperature relief valve Thermistor connection Thermistor connection (SeeEKSOLHWAV1) Re-circulation hole

22MM 3/4’’ female BSP 3/4’’ female BSP 3/4’’ female BSP 15MM 1/2’’ female BSP 3/4’’ female BSP

j 9 j 10 j 11 j 12 j 13 j 14 j 15 j 16 j 17

Pressure reducing valve Expansion relief valve T-piece (to tundish) Tundish T-piece (to expansion vessel) Adapter (expansion vessel) Expansion vessel Drain valve Solenoid valve

22MM-22MM 22MM-22MM 15MM-15MM-1/2’’ female BSP 22MM-15MM 22MM-22MM-22MM 22MM-3/4’’ female BSP female BSP 22MM-3/4’’ hale BSP 3/4’’ female BSP-3/4’’ hale BSP

Other

j 18 j 19 j 20 j 21 j 22 j 23 j 24 j 25 j 26

Switchbox Thermal protector 1+Thermostat Cable entry power, booster heater, therminal protector Cable entry power solenoid valve Cable entry solenoid valve Blind stop + 2 plastic screw-on closing caps for pressure reducing valve Thermal protector 2+Thermostat Cable entry (to EKSOLHWAV1) Cable entry from EKHB(H/X)* (see EKSOLHWAV1) Required service space Model EKHWSU150A3V3 EKHWSU200A3V3 EKHWSU300A3V3

H1 900 1150 1600

H2 1015 1265 1715

H3 255 410 410

H4 130 200 200

3TW57834-2

• Altherma • Domestic hot water tank

71

• Domestic hot water tank • DOMESTIC HOT WATER TANK • EKHWS

5

Piping diagram

EKHWSU Field supply

Field installation (delivered with indoor unit)

Indoor

Load

Shut off valve

Water return

Shut off valve

Water flow

Outdoor

3-way motorized valve

Option domestic hot water tank

Water flow

3

Water return

Option domestic hot water tank Water main IN

Water main OUT

5 Pressure reducing valve with integrated non return valve line strainer Expansion relief valve T-piece

Tundish

2-way solenoid valve

Expansion vessel *Field installation delivered with EKUHWA kit T-piece

Drain valve

RST Y1S M3S

Domestic hot water thermistor Solenoid valve 3-way motorized valve

3TW57835-1 Check valve

72

Flare connection

Screw connection

Flange connection

Pinched pipe

Spinned pipe

• Altherma • Domestic hot water tank

• Domestic hot water tank • DOMESTIC HOT WATER TANK • EKHWS

6

Wiring diagram

6-1

Wiring diagram

3

EKHWSU

1 EKHB/X* Switchbox

E4H F2B F2U K3M L N Q2T Q2L Q3L X2M∼X4M X5M1∼X7M Y1S

EKHWSU**0A3V3 Water tank Switch box

: Booster heater : Fuse booster heater : Fuse 5A/250V : Contactor booster heater : Line : Neutral : Thermostat Domestic hot water tank : Thermostat protector domestic hot water tank Thermal protector Booster heater : Terminal block : Terminal block : Solenoid valve

3 6

Notes: 1 This wiring diagram applies to the EKHWSU option : Field wiring 2 : Field wiring : Wire colour : Terminal strip : Protective earth 3 BLK=Black RED=Red BLU=Blue WHT=White PNK=Pink YLW=Yellow BRN=Brown GRY=Grey GNR=Green ORG=Orange VIO=Violet 4 Please refer to the EKHWSU**DA3V3 option manual for more installation details.

3TW57836-1

• Altherma • Domestic hot water tank

73

• Domestic hot water tank • DOMESTIC HOT WATER TANK • EKHWS

7

Operation range EKHW DOMESTIC HOT MODE outdoor temp (°CDB)

3 7

water temperature sanitary tank (°C)

BOOSTER HEATER OPERATION ONLY

4TW57753-1A

74

• Altherma • Domestic hot water tank

• Solar Kit • SOLAR KIT • EKSOLHWAV1

TABLE OF CONTENTS EKSOLHWAV1

1

Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76

2

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

77

Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

77

3

77

Dimensional drawing & centre of gravity . . . . . . . . . . . . . . . . . . . . . . . 78 Dimensional drawing

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 78

4

Piping diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80

5

Wiring diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 Wiring diagram

• Altherma • Solar Kit

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81

75

• Solar Kit • SOLAR KIT • EKSOLHWAV1

1

Features

t 1 i V aKA m W r H r e L a hO l tS oKl ESA

3 1

76

• Altherma • Solar Kit

• Solar Kit • SOLAR KIT • EKSOLHWAV1

2 2-1

Specifications TECHNICAL SPECIFICATIONS

Dimensions

Packing

Unit

Weight Packing

Height

mm

340

Depth

mm

295

Height

mm

770

Width

mm

305

Depth

mm

270

Unit

kg

8

Packed Unit

kg

9

Material Type Pressure drop

Solar side kPa

21.5

Maximum inlet temperature

Solar side °C

110

W

Type W

Sound

Sound Pressure

dBA

Water circuit

Piping connections diameter inch

Insulation material

5

46 27 3/4" FBSP EPP

°C

35

Minimum

°C

1

ELECTRICAL SPECIFICATIONS Phase Voltage

EKSOLHWAV1

1~

Frequency Hz Voltage range

1,400

Maximum

Power Supply

2

3

Power input

Unit

3

water cooled

Number of speeds

2-2

1 Brazed plate

K Logarithmic mean temperature difference (LMTD)

Ambient temperature

3

Carton kg

Capacity

Pump

795

Width

Weight Heat Exchanger

mm

EKSOLHWAV1

V

50 220-240

Minimum

-10%

Maximum

+10%

Power Supply Intake

indoor unit

• Altherma • Solar Kit

77

• Solar Kit • SOLAR KIT • EKSOLHWAV1

3

Dimensional drawing & centre of gravity

3-1

Dimensional drawing EKSOLHWAV1 + EKHWS200-300*

EKSOLHWAV1 + EKHWS150*

Detail 1

3

Detail 1

3

Switchbox domestic hot water tank

j 11 Cable entry (Altherma indoor unit) j 12 Cable entry (Pump cable) Components

j 1 j 2 j 3 j 4

Pump + switch for speed setting Heat exchanger EPP casing Non return valves

Accessories (delivered with EKSOLHWAV1) Connection type j 13 Thermistor sockel (thermistor solar pump station) (internal diameter 6.1mm) j 14 Adapter 3/4″M BSP-3/4″M BSP j 15 Adapter 3/4″F BSP-3/4″M BSP j 16 Adapter 3/4″M BSP-3/4″M BSP

CONNECTIONS j 5 Inlet connection from solar pump station j 6 Return connection to solar pump station j 7 Inlet connection from Altherma indoor unit j 8 Return connection to Altherma indoor uint j 9 EKSOLHWAV1 return connection to the domestic hot water tank heatexchanger j j 9a 200-300l Tank 9b 150l Tank j 10 EKSOLHWAV1 inlet connection from the domestic hot water tank heatexchanger

78

3/4″F BSP 3/4″F BSP 3/4″F BSP 3/4″F BSP 3/4″F BSP 3/4″F BSP

• Altherma • Solar Kit

Minimum space for service & ventilation

Detail 1 Scale: 1/4

Service space

Scale: 1/20

3TW57844-1

• Solar Kit • SOLAR KIT • EKSOLHWAV1

3

Dimensional drawing & centre of gravity

3-1

Dimensional drawing

3 EKSOLHWAV1 + EKHWS200-300*

EKSOLHWAV1 + EKHWS150*

Detail 2 Scale: 1/4

Detail 2

Detail 1

3 3

Switchbox domestic hot water tank

j 11 Cable entry (Altherma indoor unit) j 12 Cable entry (Pump cable) Components

j 1 j 2 j 3 j 4

Pump + switch for speed setting Heat exchanger EPP casing Non return valves

Accessories (delivered with EKSOLHWAV1) Connection type j 13 Thermistor sockel (thermistor solar pump station) (internal diameter 6.1mm) j 14 Adapter 3/4″M BSP-3/4″M BSP j 15 Adapter (Field supply) 3/4″F BSP-3/4″M BSP

Minimum space for service & ventilation

Model EKHWSU150* EKHWSU200* EKHWSU300*

H1 430 400 400

Service space

CONNECTIONS j 5 Inlet connection from solar pump station j 6 Return connection to solar pump station j 7 Inlet connection from Altherma indoor unit j 8 Return connection to Altherma indoor uint j 9 EKSOLHWAV1 return connection to the domestic hot water tank heatexchanger j j 9a 200-300l Tank 9b 150l Tank j 10 EKSOLHWAV1 inlet connection from the domestic hot water tank heatexchanger

3/4″F BSP 3/4″F BSP 3/4″F BSP 3/4″F BSP 3/4″F BSP

EKUHWA Kit j 16 Solenoid valve 3/4″F BSP-3/4″F BSP j 17 Adapter 3/4″M BSP-3/4″M BSP Solenoid valve

3/4″F BSP

• Altherma • Solar Kit

Scale: 1/20

3TW57844-2

79

• Solar Kit • SOLAR KIT • EKSOLHWAV1

4

Piping diagram

EKSOLHWAV1

Overview

Indoor

3-way motorized valve

Load

Shut off valve Shut off valve

Water from indoor

Field supply Solar collector

Solenoid valve 3-way motorized valve

Field supply

Field installation (delivered with indoor unit)

Outdoor

Y1S M3S

Option domestic hot water tank

Field supply Solar pump station

Water to tank

Medium from solar collector Option solar kit Medium to solar collector

3

Water from tank * Delivered with EKUHWA kit

Water to indoor

4

Detail 1 Only for EKHWSU* Water from indoor

Water to tank

Detail 1

2-way solenoid valve *

Medium from solar collector For EKHW(S/E)*

Plate heat exchanger

Medium to solar collector

Non return valve Pump Water to indoor

Water from tank Non return valve

Check valve

80

Flare connection

Screw connection

Flange connection

3TW57845-1 Pinched pipe

• Altherma • Solar Kit

Spinned pipe

• Solar Kit • SOLAR KIT • EKSOLHWAV1

5

Wiring diagram

5-1

Wiring diagram

3

EKSOLHWAV1 with EKHWS*V3 EKHWS*V3 Switchbox

EKHB/X* Switchbox

Solar pump

3 5

EKHB/X* Switchbox E4H F2B F2U K3M L N Q2T Q2L Q3L Q3T X2M∼X4M X5M1∼X7M Y1S

: Booster heater : Fuse booster heater : Fuse 5A/250V : Contactor booster heater : Line : Neutral : Thermostat protector 1 domestic hot water tank : Thermal protector : Thermal protector 2 Booster heater : Thermostat protector 2 domestic hot water tank : Terminal block : Terminal block : Solenoid valve

Notes: 1

2 3

: Field wiring : Field wiring : Wire colour : Terminal strip : Protective earth BLK=Black RED=Red BLU=Blue WHT=White PNK=Pink YLW=Yellow BRN=Brown GRY=Grey GNR=Green ORG=Orange VIO=Violet For more installation details please refer to the relevant installation manual.

3TW57846-1

EKSOLHWAV1 with EKHWS*Z2 EKHWS*Z2 Switchbox

EKHB/X* Switchbox

Solar pump

EKHB/X* Switchbox E4H F2B F2U K3M L N Q2T Q2L Q3L Q3T X2M∼X4M X5M1∼X7M Y1S

: Booster heater : Fuse booster heater : Fuse 5A/250V : Contactor booster heater : Line : Neutral : Thermostat protector 1 domestic hot water tank : Thermal protector : Thermal protector 2 Booster heater : Thermostat protector 2 domestic hot water tank : Terminal block : Terminal block : Solenoid valve

Notes: 1

2 3

: Field wiring : Field wiring : Wire colour : Terminal strip : Protective earth BLK=Black RED=Red BLU=Blue WHT=White PNK=Pink YLW=Yellow BRN=Brown GRY=Grey GNR=Green ORG=Orange VIO=Violet For more installation details please refer to the relevant installation manual.

3TW57846-1

• Altherma • Solar Kit

81

• Solar Kit • SOLAR KIT • EKSOLHWAV1

5

Wiring diagram

5-1

Wiring diagram

EKSOLHWAV1 with EKHWSU EKHWS*V3 Switchbox

EKUHWA

EKHB/X* Switchbox

Notes: 1

3 5

2 3

: Field wiring : Field wiring : Wire colour : Terminal strip : Protective earth BLK=Black RED=Red BLU=Blue WHT=White PNK=Pink YLW=Yellow BRN=Brown GRY=Grey GNR=Green ORG=Orange VIO=Violet For more installation details please refer to the relevant installation manual.

EKSOLHWAV1

EKHB/X* Switchbox

E4H F2B F2U K3M L N Q2T Q2L Q3L Q3T X2M∼X4M X5M1∼X7M Y1S

: Booster heater : Fuse booster heater : Fuse 5A/250V : Contactor booster heater : Line : Neutral : Thermostat protector 1 domestic hot water tank : Thermal protector : Thermal protector 2 Booster heater : Thermostat protector 2 domestic hot water tank : Terminal block : Terminal block : Solenoid valve

3TW57846-1

82

• Altherma • Solar Kit