R507 220-240V 60Hz

LRA (rated after 4 sec. UL984) HST. A. 18.6. Cut-in current HST. A. 18.6. Resistance, main and start winding (25°C) Ω. 3.7/14.1. Approvals. UL984/CSA-C22.2.
108KB taille 35 téléchargements 254 vues
SC12CLX LBP Compressor R404A/R507 220-240V 60Hz

Compressors

Data Sheet (Replaces CF.54.T2.02) General SC12CLX

Code number

104L2695

104L

SC12CLX Application

R404A R507

Lilac stripe Approvals

Application Application Evaporating temperature range Voltage range

°C V/Hz

LBP

Barcode on white background

-40 to -10

Yellow background

2695

DANFOSS COMPRESSORS

R

198 - 254 /60 CSIR

Max. ambient temperature Comp. cooling at ambient temp.

°C

38

32°C

F2

38°C

F2

SC12CLX 230V-60Hz 1PH THERMALLY PROTECTED

Approval mark

Design cm3

Oil quantity

cm

Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment

S O F1

12.87

3

550

g

1300

cm3

1510

kg

13.7

F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

204 178 170

ø16

watt

495

LRA (rated after 4 sec. UL984) HST

A

18.6

Cut-in current HST

A

18.6

Resistance, main and start winding (25°C)



70 150

Motor size

127 101.6 35

Motor

3.7/14.1

Approvals

UL984/CSA-C22.2

127 165 186 218

D Dimensions A

219

B

213

B1

193

B2

110

Suction connector

location/I.D. mm

C

8.2 ±0.09

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

6.2 ±0.09

pcs.

E B A

B1 B2

255

80

55

63

151

Compressors on a pallet

C

3

mm

ø19 ø9.7

37°

37°

107

September 2002

CF.54.T3.02

107 115

55 63

Displacement

Height

8349-5

Motor type

8349-2

Compressor

8258

1

Capacity (EN 12900/CECOMAF) Comp.\°C SC12CLX

-40 146

-35 282

-30 429

watt -25 590

-23.3 649

-20 770

-15 972

-10 1200 c

Capacity (ASHRAE) Comp.\°C SC12CLX

-40 169

-35 327

watt -30 497

-25 685

-23.3 753

-20 894

-15 1130

-10 1397 b 8222

Power consumption Comp.\°C SC12CLX

-40 277

-35 376

watt -30 462

-25 540

-23.3 566

-20 616

-15 696

-10 784

a2 d

Current consumption Comp.\°C SC12CLX

-40 2.58

-35 2.75

A -30 2.96

-25 3.23

-23.3 3.33

-20 3.54

-15 3.91

-10 4.32

c 11

10

COP (EN 12900/CECOMAF) Comp.\°C SC12CLX

-40 0.53

W/W

-35 0.75

-30 0.93

-25 1.09

-23.3 1.15

-20 1.25

-15 1.40

-35 0.87

-30 1.08

-25 1.27

-23.3 1.33

-20 1.45

-15 1.62

COP (ASHRAE) Comp.\°C SC12CLX

-40 0.61

-10 1.53

12

13 14

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Fan cooling F2, 220V 60Hz

EN 12900/CECOMAF 45°C 32°C 45°C

-10 1.78

Start winding Main winding Winding protector

ASHRAE 45°C 32°C 32°C

Accessories Devices

Fig.

SC12CLX

Starting relay

a2

117U6019

Cover

b

103N2008

Starting capacitor 80 µF

c

117U5019

Cord relief

d

103N1004

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

118-1917 118-1918 118-1919

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

2

CF.54.T3.02