Application Application Evaporating temperature range Voltage range
°C V/Hz
LBP
Barcode on white background
-40 to -10
Yellow background
2854
DANFOSS COMPRESSORS
198 - 254 /60
R
CSR
Max. ambient temperature Comp. cooling at ambient temp.
°C
38
32°C
F2
38°C
F2
SC15CLX 230V-60Hz 1PH 8349-6
Motor type
THERMALLY PROTECTED
Approval mark
Design cm3
Oil quantity
cm
Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment
S O F1
15.28
3
550
g
1300
cm3
1510
kg
13.7
F2
= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary
204 178 170
ø16
watt
550
LRA (rated after 4 sec. UL984) HST
A
21.8
Cut-in current HST
A
21.8
Resistance, main and start winding (25°C)
Ω
70 150
Motor size
127 101.6 35
Motor
3.5/12.1
Approvals
UL984/CSA-C22.2
127 165 186 218
D Dimensions A
219
B
213
B1
193
B2
110
Suction connector
location/I.D. mm
C
10.2 ±0.09
Process connector
location/I.D. mm
D
6.2 ±0.09
Discharge connector
location/I.D. mm
E
6.2 ±0.09
pcs.
E B A
B1 B2
255
80
55
63
151
Compressors on a pallet
C
3
mm
ø19 ø9.7
37°
37°
107
September 2002
CF.54.R3.02
107 115
55 63
Displacement
Height
8349
Compressor
8257
1
Capacity (EN 12900/CECOMAF) Comp.\°C SC15CLX
-40 179
-35 351
-30 530
watt -25 720
-23.3 788
-20 928
-15 1158
Capacity (ASHRAE) Comp.\°C SC15CLX
-40 208
-35 407
-10 1417
a3 a2
watt -30 614
-25 836
-23.3 915
-20 1078
-15 1347
e
-10 1649
c 8227
Power consumption Comp.\°C SC15CLX
-40 303
-35 414
watt -30 515
-25 610
-23.3 641
-20 699
-15 783
-10 864
-30 2.46
-25 2.90
-23.3 3.05
-20 3.33
-15 3.73
-10 4.11
Current consumption Comp.\°C SC15CLX
-40 1.51
-35 1.99
COP (EN 12900/CECOMAF) Comp.\°C SC15CLX
-40 0.59
-35 0.85
-30 1.03
W/W -25 1.18
-23.3 1.23
-20 1.33
-15 1.48
COP (ASHRAE) Comp.\°C SC15CLX
-40 0.68
d
A
-10 1.64
b e
Start winding 5
2
4
1
a2
Main winding Winding protector 1
1
2 N L
2 N L
Bleeder resistance
c
a3
W/W -35 0.98
Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Fan cooling F2, 220V 60Hz
-30 1.19
-25 1.37
-23.3 1.43
EN 12900/CECOMAF 45°C 32°C 45°C
-20 1.54
-15 1.72
-10 1.91
M
Thermostat
Fan
ASHRAE 45°C 32°C 32°C
Accessories Devices
Fig.
SC15CLX
a3
117-7038 (470 mm cable lenght) 117-7039 (550 mm cable lenght) 117-7043 (1000 mm cable lenght) 103N2008
Starting device
Cover
b
Starting relay
a2
Starting capacitor
c
Run capacitor
e
Cord relief
d
Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities
Components of starting device 103N1004 118-1917 118-1918 118-1919
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.
ENGLISH. EN. This instruction sheet provides you with the information required to safely own and operate your product. Retain these instructions for future reference. The product you have purchased is of the highest quality workmanship and material,
List of common used Power boxes (220V/50-60Hz + EU plug cable) and ACP panels. 1.11.2010. Type of bed. V e rs io n o f th e b e d. F o o t c o n tro ls a n d. /o.
Maintenance Guide ..... intended use (i.e.: do not use in swimming pools, bathrooms, etc.). The use ... Do not use this pump in swimming pools or other situations.
Rules for dryness and cleanliness of system components (DIN 8964) are ...... 332. 8230. M. 10. 12. 11. 13. 14. Main winding. Motor protector. Start winding a2 b.