Compressors for R134a 220-240V 50Hz & 60Hz Collection of

temperatures (LBP Low Back Pressure) for use in refrigerators, freezers and ..... R134a. 8270-2. DANFOSS COMPRESSORS. Barcode on white background.
10MB taille 0 téléchargements 261 vues
COMPRESSORS

Collection of Datasheets

Compressors for R134a 220-240V 50Hz & 60Hz

R E F R I G E R AT I O N A N D A I R C O N D I T I O N I N G

Standard Compressors

Energy-optimized Compressors

P-Series PL20F (50Hz) PL35F (50Hz) PL50F (50Hz) PL50F (HST/50Hz)

Page Page Page Page

12 14 16 18

T-Series TL2.5F (50Hz) TL3F (50Hz) TL4F (50Hz) TL5F (50Hz) TLS4F (50Hz) TLS5F (50Hz) TLS6F (50Hz) TLS7F (50Hz)

Page Page Page Page Page Page Page Page

20 22 24 26 28 30 32 34

N-Series NL6F (50Hz) NL7F (50Hz) NL8F (50Hz) NL9F (50Hz) NL11F (50Hz) NF7FX (50/60Hz) NF9FX (50Hz) NF10FX (50/60Hz) NF11FX (50Hz) NL10MF (50/60Hz)

Page Page Page Page Page Page Page Page Page Page

36 38 40 42 44 46 48 50 52 54

F-Series FR7.5F (50Hz) FR8.5F (50Hz) FR10F (50Hz)

Page 56 Page 58 Page 60

S-Series SC15F (50Hz) SC18F (50Hz) SC21F (50Hz) SC12G (60Hz) SC15G (60Hz) SC18G (60Hz)

Page Page Page Page Page Page

62 64 66 68 70 72

Energy-optimized Compressors

2

N-Series NLE6F (50Hz) NLE7F (50Hz) NLE8FK (50Hz) NLE9F (50Hz)

Page Page Page Page

88 90 92 94

N-Series NLE9FT (50Hz)

Page 146

Universal Compressors P-Series PL35G (50/60Hz) Page 148

High Energy-optimized Compressors T-Series TLY4F TLY5FK TLX6FK

(50Hz) (50Hz) (50Hz)

N-Series NLY5.5FK NLY6F NLY7F NLY9FK

(50Hz) (50Hz) (50Hz) (50Hz)

Page 96 Page 98 Page 100

Page Page Page Page

102 104 106 108

Variable Speed Drive Compressors T-Series TLV5F (50-60Hz) TLV6F (50-60Hz) TLV7F (50-60Hz)

Page 110 Page 112 Page 114

Tropical Compressors T-Series TLS3FT (50Hz) TLS4FT (50Hz) TLS5FT (50Hz) TFS4FT (50Hz) TFS4.5FT (50Hz)

Page Page Page Page Page

116 118 120 122 124

T-Series TL2.5G TL3G TL4G TL5G

(50/60Hz) (50/60Hz) (50/60Hz) (50/60Hz)

Page Page Page Page

150 152 154 156

F-Series FR6G FR7.5G FR8.5G FR10G FR11G

(50/60Hz) (50/60Hz) (50/60Hz) (50/60Hz) (50Hz)

Page Page Page Page Page

158 160 162 164 166

Page Page Page Page Page

168 170 172 174 176

Page Page Page Page

178 180 182 184

S-Series SC10G (50/60Hz) SC12G (50/60Hz) SC15G (50/60Hz) SC18G (50/60Hz) SC21G (50/60Hz) S-Series (Twins) SC12/12G (50Hz) SC15/15G (50Hz) SC18/18G (50Hz) SC21/21G (50Hz)

Heat Pump Compressors T-Series TL4GH

(50/60Hz) Page 186

F-Series FR7GH (50/60Hz) Page 188

P-Series PLE35F (50Hz) PLE50F (50Hz)

Page 74 Page 76

N-Series NL6FT NL6.1FT NL7FT NL9FT NL10FT

T-Series TLES3F (50Hz) TLES4F (50Hz) TLES5F (50Hz) TLES6F (50Hz) TLES7F (50Hz)

Page Page Page Page Page

S-Series SC12FT (50/60Hz) SC15FT (50/60Hz) SC18FTX (50/60Hz) SC21FTX (50Hz) SC21FTX (60Hz)

78 80 82 84 86

Energy-optimized Tropical Compressors

(50/60Hz) (50Hz) (50Hz) (50Hz) (50Hz)

Page Page Page Page Page

126 128 130 132 134

Page Page Page Page Page

136 138 140 142 144

CK.40.B7.02

S-Series SC10GH SC12GH SC15GH SC18GH SC10GHH SC15GHH SC10GH SC12GH SC15GH SC18GH

(50Hz) (50Hz) (50Hz) (50Hz) (50Hz) (50Hz) (50/60Hz) (50/60Hz) (50/60Hz) (50/60Hz)

Page Page Page Page Page Page Page Page Page Page

190 192 194 196 198 200 202 204 206 208

August 2003

1. General

This collection of datasheets contains information on Danfoss hermetic refrigeration compressors for 220-240V especially designed for refrigeration systems using refrigerant R134a (CF3-CH2F). The programme consists of the basic types PL, TL, TLV, TF, NL, NF, FR, SC and SC Twin.

8238-2

8238-3

PL

8238-16

TL (TF similar)

8238-4

TLV

NL (NF similar)

8238-6

8238-5

8238-7

FR 1.1 Compressor designations

SC

SC Twin

The compressor designations are built up according to the following system: Compressor design

Optimization level

PL

Blank Standard energy level S Semi-direct intake

TL, TF

NL, NF

FR

SC

E Energy-optimized (optimized motor) Y, X High Energyoptimized (high optimization level)

Compressor size

Nominal displacement in cm3

Exception: For PL compressors the capacity at rating point is stated

Application range F R134a LBP(MBP) FT R134a LBP tropical FK R134a LBP/(MBP) LST FX R134a LBP/(MBP) HST G R134a LBP/MBP/HBP GH R134a Heat pumps GHH R134a Heat pumps (optimized) MF R134a MBP

Start characteristics

Blank ➞ universal (principal rule) K = LST characteristics (capillary tube) X = HST characteristics (expansion valve)

Example TL

ES

5

F

NL

E

7

F

21

FT

SC

1.2 Design

August 2003

X

Compressors with the denominations PL, PLE, TLS, TFS, TLES, TLY, NL, NF and NLE are designs with semi-direct intake. Compressors with the denomination NLY are designs with direct intake. Please note that the suction and process connectors on all TLS, TLES, and TLY compressors have been interchanged as compared with the basic TL compressors. Using the wrong connector as suction connector on PL, PLE, TLS, TFS, TLES, TLY, NL, NF and NLE compressors will lead to reduced capacity and efficiency. Using the wrong connector as suction connector on the NLYs is not allowed since the compressor will not function.

CK.40.B7.02

3

1.3 Type label 105G

NL6F 220-240V~50Hz LBP LST/HST

Blue stripe Approvals Barcode on white background

R134a

6606

DANFOSS COMPRESSORS

Yellow background

1.4 Data stamping

8273-3

Application

All compressors have a yellow label with the type designation. This label has a blue stripe and the text ”R134a“. The country of origin indicated on the compressor paper label and on the compressor cover varies depending on the manufacturing place. Information can be found on our technical information sheet ”Country of Origin“.

Danfoss compressors have a manufacturing date code stamping on the housing. The form mainly used recently is stamping into the top cover of the housing. On some compressor production lines the stamping has been changed to needle printing into the side of the housing. This is going to be introduced on all products. For a certain period 2 different codes, in needle printing and cover stamping, will be used in parallel. The coding is designed not to be mixed up with the previous version.

Example (recent date code): L--4F-4400 F-203E1157 The first line states the model designation and the code no. L= last letter (or last two letters) of the compressor type -4F- = nominal displacement and application 4400 = 4 last digits in the code no. (= position mark) The second line states the date of manufacture and internal Danfoss codes. F = manufacturing place (F = Germany, AL = Slovenia, AM = Mexico) 20 = week 20 3 = 2003 E = Friday (A = Monday etc.) 115 = nominal voltage 7 = internal Danfoss code The country of origin (manufacturing place) is also stamped on the compressor cover.

Example (new date code): H49477 (6 characters) 113A01B (7 characters) Composition of line 1 H4947: Compressor type information (102H4947 = H4947) 7: internal Danfoss code Composition of line 2 11: Production week 3: Production year A: Production day A = Monday, B = Tuesday, C = Wednesday, etc. 01: Production hour 00 to 23 or shift code -1, -2, -3 B: Danfoss Compressors internal production location code A to G Germany K to N Slovenia R, S Mexico

1.5 Compressor dimensions

4

The build-in conditions (total height, weight, tube dimensions etc.) are specified in the individual datasheets including dimensioned sketches for the compressors.

CK.40.B7.02

August 2003

F

Compressors with denominations ending with F are primarily designed for low evaporating temperatures (LBP Low Back Pressure) for use in refrigerators, freezers and similar applications in regions with stable supply voltage.

FT

Compressors with denominations ending with FT are designed for low evaporation temperatures (LBP Low Back Pressure) for use in refrigerators, freezers and similar applications operating in regions with unstable supply voltage.

FK

Compressors with denominations ending with FK are F-types designed for low evaporation temperatures with LST starting characteristics (capillary tube).

FX

Compressors with denominations ending with FX are F-types designed for low evaporation temperatures with HST starting characteristics (expansion valve).

G

Compressors with denominations ending with G are primarily designed for high evaporation temperatures (HBP High Back Pressure) for use in liquid coolers, dehumidifiers, refrigerated display counters, vending machines and similar applications. The compressors can also be used for ”Heavy Duty“ purposes at low evaporating temperatures for use in refrigerators, freezers and similar applications operating in regions with unstable supply voltage.

GH

Compressors with denominations ending with GH are designed for high evaporating temperatures for cooling of electronic cabinets and for use in heat pump systems.

GHH

Compressors with denominations ending with GHH are optimized versions of GH compressors.

MF

Compressors with denominations ending with MF are primarily designed for medium evaporation temperatures (MBP Medium Back Pressure) for use in commercial refrigerators, bottle coolers, ice machines and similar applications.

2. Application range

The table on page 6 shows the normally recommended applications as regards voltage/ frequency, ambient temperature, evaporating temperature and necessary compressor cooling. The recommendations must be regarded as a guideline only as they presuppose a proper dimensioning of the refrigeration system.

2.1 Design limits

Condensing temperature Winding temperature

August 2003

In order to secure a satisfying lifetime of the compressor, and to protect the compressor against overload, some design criteria for the appliances must be fulfilled. Both the condensing temperature and the compressor temperature should be kept as low as possible. This can be done by using well-dimensioned condenser surfaces and by ensuring good ventilation around the compressor under all operating conditions. In order to protect the compressor against overload, the compressor has to start and work properly through pressure peaks obtained in the highest ambient temperature and lowest obliging voltage. At peak load the condensing temperature must not exceed 70°C. The winding temperature must not exceed 135°C. At stable operation conditions the condensing temperature must not exceed 60°C. The winding temperature must not exceed 125°C. These limitations secure a protection of valves, gaskets, oil, and motor insulation.

CK.40.B7.02

5

SC12 - 15FT SC18FTX SC21FTX SC21FTX PL35G

TL2.5G

TL3 - 4 - 5G

FR6G

FR7.5G

G

FR8.5 - 10G FR11G SC10G

SC12 - 15 - 18G SC12 - 15 - 18G SC21G SC12/12G SC15/15G Twin SC18/18G SC21/21G Twin TL4GH FR7GH GH

SC10 - 12 - 15 GH SC18GH SC10 - 12 - 15 - 18GH

GHH MF

6

SC10 - 15GHH NL10MF

F2 F2 S

F2

S

S

S

S

S S

S

S

S F2 F1

O/F1

F2

S

S

F2

F2 F2 F1

F2

S

S

S S* S

S*

S S S S S O/F1 O/F1 S F2*** F2*** F2 F2 F2 F2

S

S

S

F2

S

F2

S

F2

S

F2

O/F1

F2

F2

F2

F1

F2

O/F1

S

S

F2

F2 F2 F1

F2

F2

F2

S

F2

S

F2

O/F1

F2

O/F1

F2

F2

F2

F1

F2

O/F1

S

S

F2

F2 F2 F1

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2

F2**

F2

F2

F2

F2 F2 F2

F2

F2

198 - 254 /50

F2

F2

F2

F2

F2

F2

F2

F2

F2

198 - 254 /50 198 - 254 /50 198 - 254 /60 198 - 254 /50 198 - 254 /60 198 - 254 /50 198 - 254 /50 198 - 254 /50 198 - 254 /60 198 - 254 /50 187 - 254 /50 198 - 254 /60

F2

F2

F2

F2

F2

F2

F2**

F2

F2

F2

F2

F2

F2

F2

F2

O/F1

O/F1

O/F1

O/F1

O/F1

O/F1

F1 F2 F2

F2

F1 F2 F2

O O/F1 O/F1

CK.40.B7.02

F2

F1 F2 F2

O O/F1 O/F1

F2 O

O/F1 O/F1

The application limits regarding evaporating temperatures and motor systems are specified in the individual compressor datasheets.

FT FTX

HBP

Run capacitor compulsory Run capacitor recommended Not applicable below -25°C evaporating temperature in 43°C ambient temp. above 240V O/F1 possible at 220V nominal (187-242V)

NL6FT NL6.1FT NL7FT NL9 - 10FT NLE9FT

S F1 O/F1 F1 F2 F2

S S S*1) S*

43°C MBP

= = = =

NF11FX NL6 - 7 - 8 - 9F NL11F NLE6 - 7 - 9F - NLE8FK NLY6 - 7F - NLY5.5 - 9FK FR7.5 - 8.5 -10F SC15 - 18 - 21F TFS4 - 4.5FT TLS3 - 4 - 5FT

S

LBP

* *1) ** ***

NF9FX NF10FX

HBP

Ambient temperature 38°C LBP MBP HBP S S S* S* S S S S S* S S S S S* S* S S S* S F1 F1 F1 F1 O/F1 O/F1 F2 F2 F2 F2 F2 F2 S O/F1 S S* S O/F1 S S S S S S O/F1 S O/F1 O/F1 F2 F2 F2 F2 F2 F2 F2

Static cooling normally sufficient Oil cooling Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temp.) Fan cooling 3.0 m/s necessary Outside application range, not recommended

NF7FX

198 - 254 /50 198 - 254 /50 198 - 254 /50 198 - 254 /50 198 - 254 /50 198 - 254 /50 198 - 254 /50 198 - 254 /50 198 - 254 /50 198 - 254 /50 198 - 254 /50 198 - 254 /50 198 - 254 /50 198 - 254 /50 198 - 254 /50-60 198 - 242 /50 198 - 242 /60 198 - 242 /50 198 - 242 /50 198 - 242 /60 198 - 242 /50 198 - 254 /50 198 - 254 /50 198 - 254 /50 198 - 254 /50 198 - 254 /50 198 - 254 /50 176 - 242 /50 187 - 254 /50 187 - 254 /50 198 - 254 /60 187 - 254 /50 187 - 254 /50 187 - 254 /50 187 - 254 /50 187 - 254 /50 198 - 254 /60 187 - 254 /50 198 - 254 /60 187 - 254 /50 187 - 254 /60 198 - 254 /50 198 - 254 /60 187 - 254 /50 198 - 254 /50 198 - 254 /60 207 - 254 /60 187 - 254 /50 198 - 254 /50 198 - 254 /60 187 - 254 /50 198 - 254 /50 198 - 254 /60 187 - 254 /50 198 - 254 /50 198 - 254 /60 187 - 254 /50 198 - 254 /50 198 - 254 /60 198 - 254 /50 187 - 254 /50 198 - 254 /50 198 - 254 /60 187 - 254 /50 198 - 254 /50 198 - 254 /60 198 - 254 /60 187 - 254 /50 198 - 254 /50 198 - 254 /60

LBP S S* S S S S S S S S S S S S* S S F1 O/F1 F1 F2 F2 S O/F1 S S* S O/F1 S S S S S S S S O/F1 O/F1 F2 F2 F2 F2

32°C MPB S S* S

= = = = =

F FK FX

PL20 - 35 - 50F PLE35 - 50F TL2.5 - 3F TL4 - 5F TLS4 - 5 - 6F TLS7F TLES3F TLES4F TLES5F TLES6F TLES7F TLY4F TLY5FK TLX6FK TLV5 - 6 - 7F

Mains [V/Hz]

S O F1 F2

Compressor

August 2003

3. Electrical equipment

The compressors are equipped with a single-phase AC motor. With the exception of the smallest TL and the biggest SC compressors the TL, TLS, NL, FR, and SC compressors are designed with universal motors which means that they can obtain a high (HST) or low starting torque (LST) depending on the external electrical equipment used. The electrical equipments are classified as ”normal tight“ (IP20) The motor protector is built into the motor (winding protector). Earth connections are located on the bracket around the current lead-in of the compressor. No attempt must be made to start the compressor without a complete starting device. The compressors can be supplied with the following motor systems:

3.1 LST (RSIR)

8073

8074-2

8074

standard

alternative

PL, TL, NL, FR

TFS

8190

Compressors with the motor type Resistant Start Induction Run (RSIR) have a starting device for Low Starting Torque (LST). The design of the electrical equipment depends on the actual compressor design. The following designs of starting devices exist: a) PTC + cord relief + cover, the motor protector is built into the motor (winding protector), used for compressors with the denominations PL, TL, NL, FR, and SC. b) Relay housing including motor protector + cord relief + cover (alternative: terminal board with cord relief), used for compressors with the denomination TFS. The PTC starting device requires a pressureSC equalization before each start. This starting device is normally used in well-designed refrigerating systems with capillary tube as throttling device. The PTC needs a compressor standstill period of 5 minutes to cool down before each start. 3.2 LST (RSCR)

8075

Compressors with the motor type Resistant Start Capacitor Run (RSCR) have a starting device for Low Starting Torque (LST). This starting device consists of a PTC and a run capacitor and is mandatory for compressors with the denominations PLE, TLY and NLY. The PTC starting device requires a pressure-equalization before each start. This starting device is normally used in well-designed refrigerating systems with capillary tube as throttling device.

PLE, TLES, TLY, NLE, NLY August 2003

CK.40.B7.02

7

8076

8077-2

3.3 HST (CSIR)

PL, TL, NL, FR

NF

8088

Compressors with the motor type Capacitor Start Induction Run (CSIR) have a starting device for High Starting Torque (HST). This starting device consists of a starting relay and a starting capacitor and is used for compressors with the denominations TL, NL, NF, FR and SC. The following designs of starting devices exist: a) Relay + starting capacitor + cord relief + cover, used for compressors with the denominations TL, NL, FR and SC. b) Relay housing including motor protector + starting capacitor + cord relief (2x) + cover, used for compressors with the denomination NF. The starting device requires no pressure-equalization before each start and is normally used in refrigerating systems with expansion valve as throttling device or in capillary tube systems where pressure equalizing is not obtained during the standstill periods. The starting device is mandatory for NF-FX compressors and for some of the biggest SC compressors. The starting capacitor is designed for short time cut-in. ”1.7% ED“, which is stamped on the starting capacitor, means for instance max. 10 cutins per hour each with a duration of 6 seconds.

SC

Compressors with the motor type Capacitor Start Run (CSR) have a starting device for High Starting Torque (HST). This starting device consists of a starting relay, a starting capacitor, a run capacitor, a terminal board, a cord relief, and a cover. The starting device is mandatory for some of the biggest SC compressors. The starting capacitor is designed for short time cutin. ”1.7% ED“, which is stamped on the starting capacitor, means for instance max. 10 cut-ins per hour each with a duration of 6 seconds. 8191

3.4 HST (CSR)

SC 8

CK.40.B7.02

August 2003

3.5 Electronic unit (variable speed)

8434

TLV

The variable speed compressor motors are electronically controlled. No attemp must be made to start the compressor without a complete electronic unit, as specified in the data sheet for the compressor type in question. The electronic unit has a built-in overload protection as well as thermal protection. In case of activation of this protection the electronic unit will protect the compressor motor as well as itself. When the protection has been activated, the electronic unit automatically will restart the compressor after a certain time. The electronic unit provides the compressor with High Starting Torque (HST) which means that a pressure-equalizeation of the system before start is not necessary.

The compressors are equipped with permanent magnet rotors (PM motor) and 3 identical stator windings. The electronic unit is mounted directly on the compressor and controls the PM motor. Connecting the motor to AC mains, by fault, will damage the magnets and lead to drastically reduced efficiency, or even non functioning. For further information on which starting device to use on individual compressors, please refer to the actual datasheets (some compressors have limitations for either LST or HST).

3.6 Connections

The electrical equipments are equipped with connectors depending on the ordered code number, Starting relays: 6.3 mm spade connectors only PTCs: 6.3 or 4.8 mm spade connectors and screws Variable speed electronic unit: 6.3 mm spade connectors only The power supply must be connected as shown in the wiring diagrams for the chosen electrical equipment given in the actual datasheets.

The compressors have been approved in respect of safety by testing authorities in the majority of Western European countries. Actual standards to which the compressors have been approved are specified in the individual datasheets. Approval markings appear on the compressor labels. To fulfil the requirements of EN 60355-2-34 the protection screen 103N0476 must be applied to the PTC starting device.

7363

Most compressors which are capable of running at 60Hz have been approved in respect of safety by testing authorities UL and CSA. Actual standards to which the compressors have been approved are specified in the individual datasheets. Approval markings appear on a separate approval mark label.

R

TL3G 230V-60Hz 1PH THERMALLY PROTECTED

8284-4

3.7 Approvals

Approval mark

Protection screen

August 2003

CK.40.B7.02

9

4. Moisture and impurities

The compressors are dried to a maximum moisture content of 60 to 75 mg depending on the compressor size. The maximum impurity content is 40 to 50 mg depending on the compressor size.

5. Max. refrigerant charge

The refrigerant charge must never be too large to be contained on the condenser side of the refrigeration system. Only the refrigerant amount which is necessary for the system to function must be charged. The refrigerant amount may be critical as regards oil foaming and liquid hammer after long standstill periods. Because of this, limitations of refrigerant charges have been introduced. The maximum refrigerant charge is specified in the individual datasheets. If these limitations cannot be complied with, the risk may be reduced if a crankcase heater is properly used or if a pump down system is established.

6. Oil charge

The compressors are supplied charged with dried and degassed oil, which is normally sufficient for the lifetime of the compressor. The refrigeration systems and the system components must be dimensioned in such a way that the oil can be lead back continuously to the compressor housing without accumulating in the system, e.g. without oil pockets and with sufficient gas velocity. The compressors use polyolester oils and are approved only for these oils and R134a. The oil charge is specified in the individual datasheets.

7. Mounting

Soldering problems caused by oil in the connectors can be avoided by placing the compressor on its baseplate some time before soldering it into the system. The compressor must never be placed upside down when mounting the rubber grommets in the baseplate. Instead place the compressor on its side with the connectors upwards.

7.1 Mounting accessories

Washer

Nut M6

Washer

Grommet sleeve

Steel pin

9

9

Compressor base

Clip

Compressor base

3327-2

7382-2

Cabinet base Cabinet base

Screw M6 x 25

Rubber grommet

Rubber grommet

Bolt joint

Snap-on joint

The mounting accessories for the compressors are available in two versions, with bolt joint or snap-on joint. The code numbers for the mounting accessories are specified in the individual compressor datasheets. These rubber grommets are designed for the 5/8 in. (16 mm) holes of the baseplate: Bolt joint for one compressor in a bag 118 - 1917 (with screw M6 x 25 mm) 118 - 1946 (with screws 1/4 inch) Bolt joint in quantities 118 - 1918 (with screws M6 x 25 mm) Snap-on in quantities 118 - 1919 Snap-on for one compressor in a bag 118 - 1947 These rubber grommets are designed for the 3/4 in. (19 mm) holes of the baseplate: Bolt joint in quantities 118 - 1949 (with screws 1/4 inch)

10

CK.40.B7.02

August 2003

8. Condition at delivery

The compressors are delivered without mounted starting devices on pallets with the dimensions 1144 x 800 mm. Quantities per pallets are specified in the individual datasheets. Electrical equipment is packed in separate boxes. The most important performance controls carried out during manufacturing are, • A high potential insulation test with 1650V for 1 second • Pumping capacity • Tightness of discharge side and discharge valve • Tightness of compressor housing • Check of the right oil charge • Noise test The compressors are supplied with sealed connectors and the sealing should not be removed before the system assembly takes place (max. 15 minutes with open connectors).

9. Twin-compressors

The Twin version consists of two SC compressors mounted on a common baseplate. The two compressors are joined by an oil-equalizing tube and also have an intake manifold with screw connector for a service valve or a solder connector (these parts are supplied as accessories). Each Twin compressor is supplied with two sets of electrical equipment and mounting accessories. To ensure optimum starting characteristics and the smallest possible mains load we recommend that the compressors be equipped with a time-delay relay for start of the second compressor.Twin compressors can operate with capacity regulation depending on the controls used.

10. Conversion from R12 to R134a

Normally, the capillary tube shall be adjusted at low evaporating temperatures. Compared to an optimized R12 system with the same evaporator capacity, the R134a system must have an increased resistance defined as approx. 10% less N2 flow at 10 bar inlet pressure. The same size of capillary tube as used for R12 can be used at high evaporating temperatures. • A drier with 3Å desiccant of Molecular Sieves must always be used. • Rules for dryness and cleanliness of system components (DIN 8964) are transferred to R134a systems. • The system components must not contain mineral oil or greasy substances. • The compressors must be soldered into the system no later than 15 minutes after the connector seals have been removed. • The same evacuation procedure as for R12 systems must be used. • Max. 1% non-condensable gases. • The system must not contain any chlorine. • The charging equipment must only be used for R134a. • If the same vacuum pump is to be used for R12 and R134a systems, a special Ester oil must be used in agreement with the pump supplier.

11. Warnings

No high potential test nor start tests must be carried out while the compressor is under vacuum. No attempt must be made to start the compressor without a complete starting device. Allow the compressor to assume a temperature above 10°C before starting the first time in order to avoid starting problems. Anti-freeze agents must not be used in the compressors as such agents are damaging to several of the materials used. In particular, the ethyl or methyl alcohol contents of such anti-freeze agents have a destructive effect on the synthetic motor insulation.

August 2003

CK.40.B7.02

11

PL20F Standard Compressor R134a 220-240V 50Hz Data Sheet (Replaces CD.41.B8.02) General PL20F

Code number

101G0100

PL20F R134a

Blue stripe

Application

101G

Application

0100

Approvals

Application Evaporating temperature range Voltage range

°C V/Hz

MBP

Barcode on white background

-25 to 0

Yellow background

DANFOSS COMPRESSORS

8270-2

Compressor

198 - 254 /50

Motor type

RSIR

Max. ambient temperature Comp. cooling at ambient temp.

°C

38

32°C

S

38°C

S

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

Design Displacement

cm3

Oil quantity

cm3

150

g

300

cm3

800

kg

3.8

Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment

1.41

Motor Motor size

watt

29

LRA (rated after 4 sec. UL984) LST

A

1.2

Cut-in current LST

A

5.7

Resistance, main and start winding (25°C)



84.0/19.0 100

EN 60335-2-34 with Annex AA 35 70

Approvals

204 170

Dimensions Height

Suction connector

mm

location/I.D. mm

A

129

B

127

B1

120

B2

73

C

6.2 ±0.09

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

5.0 +0.12/+0.20

pcs.

C

D

ø9

E

B1 B A B2 206

150

8241

46 59 130

50 60.5

Compressors on a pallet

ø16

127

February 2003

12

CD.41.B9.02

CK.40.B7.02

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C PL20F

-25 16.0

-23.3 19.0

-20 25.4

watt -15 36.5

-10 49.6

-5 64.9

0 82.6 g

Capacity (ASHRAE) Comp.\°C PL20F

-25 19.7

-23.3 23.4

watt -20 31.3

-15 45.0

-10 61.3

-5 80.3

-20 46.4

-15 51.5

-10 57.2

-5 63.3

0 69.7

-20 0.36

-15 0.37

-10 0.39

-5 0.41

0 0.43

Power consumption Comp.\°C PL20F

-25 42.0

-23.3 43.4

0 102

-25 0.35

-23.3 0.35

-25 0.38

-25 0.47

d Main winding a1 Start winding N

W/W

-23.3 0.44

-20 0.55

-15 0.71

-10 0.87

-5 1.03

-23.3 0.54

-20 0.67

-15 0.87

-10 1.07

-5 1.27

COP (ASHRAE) Comp.\°C PL20F

a1

A

COP (EN 12900/CECOMAF) Comp.\°C PL20F

8224

watt

Current consumption Comp.\°C PL20F

b

0 1.19

N

C

L

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Static cooling, 220V 50Hz, PTC consumption incl.

EN 12900/CECOMAF 55°C 32°C 55°C

0 1.47

Winding protector

ASHRAE 55°C 32°C 32°C

Accessories Devices PTC starting device

6.3 mm spades 4.8 mm spades

Fig.

PL20F

a1

103N0011 103N0018

Cover

b

103N0491

Cord relief

d

103N1010

Protection screen for PTC

g

103N0476

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

118-1917 118-1918 118-1919

CD.41.B9.02

CK.40.B7.02

February 2003

13

PL35F Standard Compressor R134a 220-240V 50Hz Data Sheet (Replaces CD.41.E3.02) General PL35F

Code number

101G0202

PL35F R134a

Blue stripe

Application

101G

Application

0202

Approvals

Application Evaporating temperature range Voltage range

°C V/Hz

MBP

Barcode on white background

-25 to 0

Yellow background

DANFOSS COMPRESSORS

8270

Compressor

198 - 254 /50

Motor type

RSIR

Max. ambient temperature Comp. cooling at ambient temp.

°C

38

32°C

S

38°C

S

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

Design Displacement

cm3

Oil quantity

cm3

150

g

300

cm3

830

kg

4.1

Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment

2.00

Motor Motor size

watt

43

LRA (rated after 4 sec. UL984) LST

A

1.7

Cut-in current LST

A

5.6

Resistance, main and start winding (25°C)



204 170

52.0/19.0 100

EN 60335-2-34 with Annex AA 35 70

Approvals

Dimensions Height

Suction connector

mm

location/I.D. mm

A

134

B

132

B1

125

B2

73

C

6.2 ±0.09

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

5.0 +0.12/+0.20

pcs.

C

D

ø9

E

B1 B A B2 206

150

8241

46 59 130

50 60.5

Compressors on a pallet

ø16

127

February 2003

14

CD.41.E4.02

CK.40.B7.02

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C PL35F

-25 32

-23.3 36

-20 45

watt -15 60

-10 79

-5 101

0 125 g

Capacity (ASHRAE) Comp.\°C PL35F

-25 39

-23.3 44

watt -20 55

-15 74

-10 97

-5 124

-20 57

-15 64

-10 72

-5 80

0 88

-20 0.51

-15 0.53

-10 0.55

-5 0.58

0 0.62

Power consumption Comp.\°C PL35F

-25 50

-23.3 52

0 155

-25 0.50

-23.3 0.50

-25 0.64

-25 0.78

d Main winding a1 Start winding N

W/W

-23.3 0.69

-20 0.79

-15 0.94

-10 1.10

-5 1.26

-23.3 0.85

-20 0.97

-15 1.16

-10 1.36

-5 1.55

COP (ASHRAE) Comp.\°C PL35F

a1

A

COP (EN 12900/CECOMAF) Comp.\°C PL35F

8224

watt

Current consumption Comp.\°C PL35F

b

0 1.42

N

C

L

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Static cooling, 220V 50Hz, PTC consumption incl.

EN 12900/CECOMAF 55°C 32°C 55°C

0 1.76

Winding protector

ASHRAE 55°C 32°C 32°C

Accessories Devices PTC starting device

6.3 mm spades 4.8 mm spades

Fig.

PL35F

a1

103N0011 103N0018

Cover

b

103N0491

Cord relief

d

103N1010

Protection screen for PTC

g

103N0476

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

118-1917 118-1918 118-1919

CD.41.E4.02

CK.40.B7.02

February 2003

15

PL50F Standard Compressor R134a 220-240V 50Hz Data Sheet (Replaces CD.41.F3.02) General PL50F

Code number

101G0220

PL50F R134a

Blue stripe

Application

101G

Application

0220

Approvals

Application Evaporating temperature range Voltage range

°C V/Hz

LBP

Barcode on white background

-35 to -10

Yellow background

DANFOSS COMPRESSORS

8270-3

Compressor

198 - 254 /50

Motor type

RSIR

Max. ambient temperature Comp. cooling at ambient temp.

°C

38

32°C

S

38°C

S

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

Design Displacement

cm3

Oil quantity

cm3

150

g

300

cm3

850

kg

4.3

Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment

2.50

Motor Motor size

watt

54

LRA (rated after 4 sec. UL984) LST

A

2.2

Cut-in current LST

A

6.0

Resistance, main and start winding (25°C)



38.0/20.0 100

EN 60335-2-34 with Annex AA 35 70

Approvals

204 170

Dimensions Height

Suction connector

mm

location/I.D. mm

A

137

B

135

B1

128

B2

73

C

6.2 ±0.09

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

5.0 +0.12/+0.20

pcs.

C

D

ø9

E

B1 B A B2 206

150

8241

46 59 130

50 60.5

Compressors on a pallet

ø16

127

February 2003

16

CD.41.F4.02

CK.40.B7.02

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C PL50F

-35 14.2

-30 26.2

-25 40.0

watt -23.3 45.1

-20 55.8

-15 74.1

-10 95.2 g

Capacity (ASHRAE) Comp.\°C PL50F

-35 17.4

-30 32.3

watt -25 49.3

-23.3 55.6

-20 68.9

-15 91.5

-25 60.0

-23.3 62.7

-20 68.1

-15 76.5

-10 85.6

-25 0.50

-23.3 0.51

-20 0.53

-15 0.55

-10 0.58

Power consumption Comp.\°C PL50F

-35 43.6

-30 51.9

-10 118

-35 0.47

-30 0.48

-35 0.32

-35 0.40

d Main winding a1 Start winding N

W/W

-30 0.50

-25 0.67

-23.3 0.72

-20 0.82

-15 0.97

-30 0.62

-25 0.82

-23.3 0.89

-20 1.01

-15 1.20

COP (ASHRAE) Comp.\°C PL50F

a1

A

COP (EN 12900/CECOMAF) Comp.\°C PL50F

8224

watt

Current consumption Comp.\°C PL50F

b

-10 1.11

N

C

L

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Static cooling, 220V 50Hz, PTC consumption incl.

EN 12900/CECOMAF 55°C 32°C 55°C

-10 1.38

Winding protector

ASHRAE 55°C 32°C 32°C

Accessories Devices PTC starting device

6.3 mm spades 4.8 mm spades

Fig.

PL50F

a1

103N0011 103N0018

Cover

b

103N0491

Cord relief

d

103N1010

Protection screen for PTC

g

103N0476

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

118-1917 118-1918 118-1919

CD.41.F4.02

CK.40.B7.02

February 2003

17

PL50F Standard Compressor HST Starting Characteristics R134a 220-240V 50Hz Data Sheet (Replaces CD.41.G3.02) General PL50F

Code number

101G0222

PL50F R134a

Blue stripe

Application

101G

Application

0222

Approvals

Application Evaporating temperature range Voltage range

°C V/Hz

MBP

Barcode on white background

-25 to 0

Yellow background

DANFOSS COMPRESSORS

8283-2

Compressor

198 - 254 /50

Motor type

CSIR

Max. ambient temperature Comp. cooling at ambient temp.

°C

38

32°C

F2

38°C

F2

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

Design Displacement

cm3

Oil quantity

cm3

150

g

300

cm3

850

kg

4.3

Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment

2.50

Motor Motor size

watt

54

LRA (rated after 4 sec. UL984) HST

A

4.2

Cut-in current HST

A

4.2

Resistance, main and start winding (25°C)



38.0/14.0 100

EN 60335-2-34 with Annex AA 35 70

Approvals

204 170

Dimensions Height

Suction connector

mm

location/I.D. mm

A

137

B

135

B1

128

B2

73

C

6.2 ±0.09

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

5.0 +0.12/+0.20

pcs.

C

D

ø9

E

B1 B A B2 206

150

8241

46 59 130

50 60.5

Compressors on a pallet

ø16

127

February 2003

18

CD.41.G4.02

CK.40.B7.02

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C PL50F

-25 40.0

-23.3 45.1

-20 55.8

watt

-15 74.1

-10 95.2

-5 120

0 148 c

Capacity (ASHRAE) Comp.\°C PL50F

-25 49.3

-23.3 55.6

watt -20 68.9

-15 91.5

-10 118

-5 148

0 183 b

Power consumption Comp.\°C PL50F

-25 58.0

-23.3 60.7

watt -20 66.1

-15 74.5

-10 83.6

-5 93.7

8225

0 105

a2 d

Current consumption Comp.\°C PL50F

-25 0.50

-23.3 0.51

A -20 0.53

-15 0.55

-10 0.58

-5 0.62

0 0.66

c 11

10

COP (EN 12900/CECOMAF) Comp.\°C PL50F

-25 0.69

W/W

-23.3 0.74

-20 0.84

-15 0.99

-10 1.14

-5 1.28

-23.3 0.92

-20 1.04

-15 1.23

-10 1.41

-5 1.58

COP (ASHRAE) Comp.\°C PL50F

-25 0.85

0 1.41

12

13 14

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Fan cooling, 220V 50Hz

EN 12900/CECOMAF 55°C 32°C 55°C

0 1.74

Main winding Winding protector

Start winding

ASHRAE 55°C 32°C 32°C

Accessories Devices

Fig.

PL50F

Starting relay

a2

117U6021

Cover

b

103N0491

Starting capacitor 60 µF

c

117U5014

Cord relief

d

103N1010

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

118-1917 118-1918 118-1919

CD.41.G4.02

CK.40.B7.02

February 2003

19

TL2.5F Standard Compressor R134a 220-240V 50Hz Data Sheet (Replaces CD.42.S3.02) General TL2.5F

102G

TL2.5F

Code number (small baseplate)

102G4200

Code number (large baseplate)

102G4201

Application

R134a

Blue stripe Approvals

4200

Barcode on white background

Application Application

MBP

Evaporating temperature range Voltage range

°C

-25 to 0

V/Hz

198 - 254 /50

Motor type

RSIR

Max. ambient temperature

°C

38

32°C

S

38°C

S

Displacement

cm3

2.61

Oil quantity

cm3

180

g

400

cm3

1600

kg

6.7

Comp. cooling at ambient temp.

DANFOSS COMPRESSORS

Yellow background

8271-2

Compressor

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

Design

Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment

ø3.6

ø16

LRA (rated after 4 sec. UL984) LST

watt

60

A

2.3

35 70 100

Motor size

Cut-in current LST

A

7.0

ø9

Resistance, main and start winding (25°C)



40.0/15.0

ø19

Approvals

163 159

E

Suction connector

location/I.D. mm

C 6.2 ±0.09

6.5 ±0.09

Process connector

location/I.D. mm

D 6.2 ±0.09

6.5 ±0.09

Discharge connector

location/I.D. mm

E 5.0 +0.12/+0.20

Compressors on a pallet

pcs.

D C

or

222 176

° 31.5 28°

A B

C or D

A B

105 107

mm

102G4201

30°

102G4200

105

Height

170 178 186 204

EN 60335-2-34 with Annex AA, CCIB

Dimensions

101.6 136

Motor

5.0 +0.12/+0.20 125

102

June 2001

20

CD.42.S4.02

CK.40.B7.02

71

29

51 20° °

45°

157 60.5 66

8428

96 117

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C TL2.5F

-25 32

-23.3 37

-20 47

watt -15 65

-10 86

-5 110

0 137 g

Capacity (ASHRAE) Comp.\°C TL2.5F

-25 39

-23.3 45

watt -20 58

-15 80

-10 106

-5 136

0 169

-20 63

-15 71

-10 80

-5 89

0 98

-20 0.46

-15 0.49

-10 0.52

-5 0.55

0 0.58

Power consumption Comp.\°C TL2.5F

-25 54

-23.3 57

-25 0.44

-23.3 0.45

-25 0.59

-25 0.73

d Main winding a1 Start winding N

W/W

-23.3 0.64

-20 0.75

-15 0.91

-10 1.07

-5 1.24

-23.3 0.79

-20 0.92

-15 1.12

-10 1.33

-5 1.53

0 1.40

COP (ASHRAE) Comp.\°C TL2.5F

a1

A

COP (EN 12900/CECOMAF) Comp.\°C TL2.5F

8217

watt

Current consumption Comp.\°C TL2.5F

b

N

C

L

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Static cooling, 220V 50Hz, PTC consumption incl.

EN 12900/CECOMAF 55°C 32°C 55°C

0 1.73

Winding protector

ASHRAE 55°C 32°C 32°C

Accessories Devices PTC starting device

6.3 mm spades 4.8 mm spades

Fig.

TL2.5F

a1

103N0011 103N0018

Cover

b

103N2010

Cord relief

d

103N1010

Protection screen for PTC

g

103N0476

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

118-1917 118-1918 118-1919

CD.42.S4.02

CK.40.B7.02

June 2001

21

TL3F Standard Compressor R134a 220-240V 50Hz Data Sheet (Replaces CD.42.I5.02) General TL3F

Code number

102G4300

102G

TL3F Application

R134a

Blue stripe Approvals

Application Application Evaporating temperature range Voltage range

°C V/Hz

MBP

Barcode on white background

-25 to 0

Yellow background

4300

8271-3

Compressor

DANFOSS COMPRESSORS

198 - 254 /50

Motor type

RSIR/CSIR

Max. ambient temperature Comp. cooling at ambient temp.

°C

38

32°C

S

38°C

S

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

Design Displacement

cm3

Oil quantity

cm3

180

g

400

cm3

1600

kg

6.7

Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment

3.13

ø16

Motor watt

LRA (rated after 4 sec. UL984) LST/HST

75

A

2.8/4.5

Cut-in current LST/HST

A

7.5/4.5

Resistance, main and start winding (25°C)



31.5/15.0

Approvals

A

163

B

159

location/I.D. mm

C

6.2 ±0.09

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

5.0 +0.12/+0.20

C or D

E

pcs.

105

105 107

A B

Compressors on a pallet

D C

or

222 176

30°

mm

170 178 186 204

° 31.5 28°

Suction connector

ø9

EN 60335-2-34 with Annex AA, CCIB

Dimensions Height

35 70 100

Motor size

125

102

June 2001

22

CD.42.I6.02

CK.40.B7.02

71

29

51 20° °

45°

157 60.5 66

8263

96 117

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C TL3F

-25 42

-23.3 48

-20 60

watt -15 82

-10 108

-5 138

0 173

HST c

Capacity (ASHRAE) Comp.\°C TL3F

-25 52

-23.3 59

watt -20 74

-15 101

-10 133

-5 171

0 214 b

Power consumption Comp.\°C TL3F

-25 66

-23.3 69

watt -20 76

-15 87

-10 99

-5 111

8219

0 124

a2 d

Current consumption Comp.\°C TL3F

-25 0.50

-23.3 0.51

A -20 0.52

-15 0.54

-10 0.57

-5 0.61

0 0.67

c 11

10

COP (EN 12900/CECOMAF) Comp.\°C TL3F

-25 0.64

W/W

-23.3 0.69

-20 0.79

-15 0.94

-10 1.09

-5 1.24

-23.3 0.85

-20 0.97

-15 1.16

-10 1.35

-5 1.53

COP (ASHRAE) Comp.\°C TL3F

-25 0.78

0 1.39

12

13 14

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Static cooling, 220V 50Hz, PTC consumption incl.

EN 12900/CECOMAF 55°C 32°C 55°C

0 1.72

Main winding

ASHRAE 55°C 32°C 32°C

Winding protector Start winding

LST g

b 8217

a1

Accessories Devices

d

Fig.

TL3F

a1

103N0011 103N0018

Starting relay

a2

117U6007

PTC starting device

6.3 mm spades 4.8 mm spades

Main winding a1 Start winding N

Cover

b

103N2010

Starting capacitor 60 µF

c

117U5014

Cord relief

d

103N1010

Protection screen for PTC

g

103N0476

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

N

118-1917 118-1918 118-1919

C

L

Winding protector

CD.42.I6.02

CK.40.B7.02

June 2001

23

TL4F Standard Compressor R134a 220-240V 50Hz Data Sheet (Replaces CD.42.Z1.02) General TL4F

102G

TL4F

Code number

102G4400

Code number

102G4426

Application

R134a

Blue stripe Approvals

Application Application Evaporating temperature range Voltage range

°C

4400

Barcode on white background

LBP

8271-4

Compressor

DANFOSS COMPRESSORS

Yellow background

-35 to -10

V/Hz

198 - 254 /50

Motor type

RSIR/CSIR

Max. ambient temperature Comp. cooling at ambient temp.

°C

38

32°C

S

38°C

S

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

Design Displacement

cm3

Oil quantity

cm3

180

g

400

cm3

1600

kg

6.7

Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment

3.86

ø16

Motor size

watt

85

alternative motor

80

LRA (rated after 4 sec. UL984) LST/HST

A

3.2/4.8

alternative motor

ø9

3.2/4.6 A

170 178 186 204

7.5/4.8

alternative motor

7.8/4.6

Resistance, main and start winding (25°C) Ω

25.7/16.3

E

26.8/13.5 EN 60335-2-34 with Annex AA, CCIB

° 31.5 28°

A

163

B

159

Suction connector

location/I.D. mm

C 6.2 ±0.09

6.5 ±0.09

Process connector

location/I.D. mm

D 6.2 ±0.09

6.5 ±0.09

Discharge connector

location/I.D. mm

E 5.0 +0.12/+0.20

pcs.

5.0 +0.12/+0.20 125

105

45°

Compressors on a pallet

8263

102

June 2001

24

CD.42.Z2.02

CK.40.B7.02

51 20° °

mm

102G4426

157 60.5 66

Height

102G4400

105 107

A B

Dimensions

71

Approvals

D C

or

222 176

29

alternative motor

C or D

30°

Cut-in current LST/HST

35 70 100

Motor

96 117

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C TL4F

-35 31

-30 44

-25 61

watt -23.3 67

-20 81

-15 107

-10 137

HST c

Capacity (ASHRAE) Comp.\°C TL4F

-35 38

-30 54

watt -25 75

-23.3 83

-20 100

-15 131

-10 170 b

Power consumption Comp.\°C TL4F

-35 60

-30 70

watt -25 81

-23.3 85

-20 93

-15 107

8219

-10 122

a2 d

Current consumption Comp.\°C TL4F

-35 0.51

-30 0.53

A -25 0.55

-23.3 0.56

-20 0.58

-15 0.63

-10 0.69

c 11

10

COP (EN 12900/CECOMAF) Comp.\°C TL4F

-35 0.52

W/W

-30 0.63

-25 0.75

-23.3 0.79

-20 0.88

-15 1.00

-10 1.12

-30 0.77

-25 0.92

-23.3 0.98

-20 1.08

-15 1.24

-10 1.38

COP (ASHRAE) Comp.\°C TL4F

-35 0.64

12

13 14

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Static cooling, 220V 50Hz, PTC consumption incl.

EN 12900/CECOMAF 55°C 32°C 55°C

Main winding

ASHRAE 55°C 32°C 32°C

Winding protector Start winding

LST g

b 8217

a1

Accessories Devices

d

Fig.

TL4F

a1

103N0011 103N0018

Starting relay

a2

117U6009

PTC starting device

6.3 mm spades 4.8 mm spades

Main winding a1 Start winding N

Cover

b

103N2010

Starting capacitor 60 µF

c

117U5014

Cord relief

d

103N1010

Protection screen for PTC

g

103N0476

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

N

118-1917 118-1918 118-1919

C

L

Winding protector

CD.42.Z2.02

CK.40.B7.02

June 2001

25

TL5F Standard Compressor R134a 220-240V 50Hz Data Sheet (Replaces CG.42.B1.02) General TL5F

Code number

102G4501

102G

TL5F Application

R134a

Blue stripe Approvals

Application Application Evaporating temperature range Voltage range

°C V/Hz

LBP

Barcode on white background

-35 to -10

Yellow background

4501

8271

Compressor

DANFOSS COMPRESSORS

198 - 254 /50

Motor type

RSIR/CSIR

Max. ambient temperature Comp. cooling at ambient temp.

°C

38

32°C

S

38°C

S

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

Design Displacement

cm3

Oil quantity

cm3

180

g

400

cm3

1790

kg

7.5

Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment

5.08

ø16

Motor watt

110

alternative motor

125

LRA (rated after 4 sec. UL984) LST/HST

A

4.3/5.1

alternative motor Cut-in current LST/HST

35 70 100

Motor size

4.7/5.8 A

ø9

8.6/5.1

alternative motor

170 178 186 204

8.7/5.8

Resistance, main and start winding (25°C) Ω

18.2/15.1

alternative motor

16.0/17.0

Approvals

C or D

E

EN 60335-2-34 with Annex AA, CCIB 30°

° 31.5 28°

169

C

6.2 ±0.09

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

5.0 +0.12/+0.20

Compressors on a pallet

pcs.

125

8263

45° 102

June 2001

26

CG.42.B2.02

CK.40.B7.02

71

B location/I.D. mm

105 107

173

105

A

51 20° °

Suction connector

A B

mm

157 60.5 66

Height

29

Dimensions

D C

or

222 176

96 117

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C TL5F

-35 43

-30 60

-25 82

watt -23.3 91

-20 110

-15 144

-10 183

HST c

Capacity (ASHRAE) Comp.\°C TL5F

-35 53

-30 74

watt -25 101

-23.3 112

-20 136

-15 177

-10 226 b

Power consumption Comp.\°C TL5F

-35 70

-30 85

watt -25 101

-23.3 107

-20 118

-15 136

8219

-10 154

a2 d

Current consumption Comp.\°C TL5F

-35 0.75

-30 0.78

A -25 0.81

-23.3 0.83

-20 0.86

-15 0.91

-10 0.97

c 11

10

COP (EN 12900/CECOMAF) Comp.\°C TL5F

-35 0.61

W/W

-30 0.70

-25 0.81

-23.3 0.85

-20 0.93

-15 1.06

-10 1.19

-30 0.86

-25 1.00

-23.3 1.05

-20 1.15

-15 1.30

-10 1.47

COP (ASHRAE) Comp.\°C TL5F

-35 0.75

12

13 14

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Static cooling, 220V 50Hz, PTC consumption incl.

EN 12900/CECOMAF 55°C 32°C 55°C

Main winding

ASHRAE 55°C 32°C 32°C

Winding protector Start winding

LST g

b 8217

a1

Accessories Devices

d

Fig.

TL5F

a1

103N0011 103N0018

Starting relay

a2

117U6004

PTC starting device

6.3 mm spades 4.8 mm spades

Main winding a1 Start winding N

Cover

b

103N2010

Starting capacitor 60 µF

c

117U5014

Cord relief

d

103N1010

Protection screen for PTC

g

103N0476

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

N

118-1917 118-1918 118-1919

C

L

Winding protector

CG.42.B2.02

CK.40.B7.02

June 2001

27

TLS4F Standard Compressor R134a 220-240V 50Hz Data Sheet (Replaces CG.42.J3.02) General TLS4F

Code number

102G4425

Application

R134a SUCTION CONNECTOR

Blue stripe

Application Application

LBP

Evaporating temperature range Voltage range

°C

-35 to -10

V/Hz

198 - 254 /50

Motor type

102G

TLS4F

4425

Approvals Barcode on white background

8272-4

Compressor

DANFOSS COMPRESSORS

Yellow background

RSIR/CSIR

Max. ambient temperature Comp. cooling at ambient temp.

°C

38

32°C

S

38°C

S

S O F1 F2

Design 3

Displacement

cm

Oil quantity

cm3

180

g

400

cm3

1600

kg

6.7

watt

85

Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

3.86

Motor Motor size

80

LRA (rated after 4 sec. UL984) LST/HST

A

3.2/4.8

A

7.5/4.8

alternative motor Cut-in current LST/HST

35 70 100

alternative motor

ø16

3.2/4.6

alternative motor

ø9

7.8/4.6

Resistance, main and start winding (25°C) Ω

170 178 186 204

25.7/16.3

alternative motor

26.8/13.5

Approvals

EN 60335-2-34 with Annex AA

C

D

222 176

E Dimensions

C

6.2 ±0.09

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

5.0 +0.12/+0.20 125

8244

45°

102

May 2001

28

CG.42.J4.02

CK.40.B7.02

51 20° °

pcs.

157 60.5 66

Compressors on a pallet

71

location/I.D. mm

Process connector

105 107

Suction connector

A B

29

163 159

30°

A B

105

mm

° 31.5 28°

Height

96 117

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C TLS4F

-35 34.6

-30 51.5

-25 72.0

watt -23.3 79.9

-20 96.8

-15 126

-10 162

HST c

Capacity (ASHRAE) Comp.\°C TLS4F

-35 42.6

-30 63.5

watt -25 88.9

-23.3 98.6

-20 119

-15 156

-10 200 b

Power consumption Comp.\°C TLS4F

-35 67.5

-30 77.8

watt -25 89.0

-23.3 93.0

-20 101

-15 115

8219

-10 130

a2 d

Current consumption Comp.\°C TLS4F

-35 0.59

-30 0.62

A -25 0.66

-23.3 0.68

-20 0.71

-15 0.76

-10 0.81

c 11

10

COP (EN 12900/CECOMAF) Comp.\°C TLS4F

-35 0.51

W/W

-30 0.66

-25 0.81

-23.3 0.86

-20 0.96

-15 1.10

-10 1.25

-30 0.82

-25 1.00

-23.3 1.06

-20 1.18

-15 1.36

-10 1.54

COP (ASHRAE) Comp.\°C TLS4F

-35 0.63

12

13 14

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Static cooling, 220V 50Hz

EN 12900/CECOMAF 55°C 32°C 55°C

Main winding

ASHRAE 55°C 32°C 32°C

Winding protector Start winding

LST g

b 8217

a1

Accessories Devices

Fig.

TLS4F

a1

103N0011 103N0018

Starting relay

a2

117U6009

PTC starting device

6.3 mm spades 4.8 mm spades

d Main winding a1 Start winding N

Cover

b

103N2010

Starting capacitor 60 µF

c

117U5014

Cord relief

d

103N1010

Protection screen for PTC

g

103N0476

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

N

118-1917 118-1918 118-1919

C

L

Winding protector

CG.42.J4.02

CK.40.B7.02

May 2001

29

TLS5F Standard Compressor R134a 220-240V 50Hz Data Sheet (Replaces CD.42.K5.02) General TLS5F

Application

Code number

102G4520

Code number

102G4526

102G

TLS5F R134a SUCTION CONNECTOR

Blue stripe

4520

Approvals

Application Application

Barcode on white background

LBP

Evaporating temperature range Voltage range

°C

198 - 254 /50

Motor type

RSIR/CSIR °C

38

32°C

S

38°C

S

Displacement

cm3

5.08

Oil quantity

cm3

180

g

400

cm3

1790

kg

7.3

Comp. cooling at ambient temp.

DANFOSS COMPRESSORS

Yellow background

-35 to -10

V/Hz

Max. ambient temperature

8272

Compressor

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

Design

Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment

ø16

Motor size

watt

125

alternative motor

110

LRA (rated after 4 sec. UL984) LST/HST

A

4.7/5.8

alternative motor

ø9

4.3/5.1 A

170 178 186 204

8.7/5.8

alternative motor

8.6/5.1

Resistance, main and start winding (25°C) Ω

16.0/17.0

D

222 176

E

18.2/15.1 EN 60335-2-34 with Annex AA

° 31.5 28°

A

173

B

169

Suction connector

location/I.D. mm

C 6.2 ±0.09

6.5 ±0.09

Process connector

location/I.D. mm

D 6.2 ±0.09

6.5 ±0.09

Discharge connector

location/I.D. mm

E 5.0 +0.12/+0.20

pcs.

5.0 +0.12/+0.20 125

105

45°

Compressors on a pallet

8244

102

May 2001

30

CD.42.K6.02

CK.40.B7.02

51 20° °

mm

102G4526

157 60.5 66

Height

102G4520

105 107

A B

Dimensions

71

Approvals

29

alternative motor

C

30°

Cut-in current LST/HST

35 70 100

Motor

96 117

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C TLS5F

-35 47.8

-30 70.7

-25 98.0

watt -23.3 109

-20 131

-15 170

-10 216

HST c

Capacity (ASHRAE) Comp.\°C TLS5F

-35 58.9

-30 87.2

watt -25 121

-23.3 134

-20 161

-15 209

-10 267 b

Power consumption Comp.\°C TLS5F

-35 82.7

-30 97.1

watt -25 112

-23.3 117

-20 128

-15 144

8219

-10 162

a2 d

Current consumption Comp.\°C TLS5F

-35 0.96

-30 0.98

A -25 1.01

-23.3 1.02

-20 1.05

-15 1.10

-10 1.15

c 11

10

COP (EN 12900/CECOMAF) Comp.\°C TLS5F

-35 0.58

W/W

-30 0.73

-25 0.88

-23.3 0.93

-20 1.02

-15 1.18

-30 0.90

-25 1.08

-23.3 1.14

-20 1.26

-15 1.45

COP (ASHRAE) Comp.\°C TLS5F

-35 0.71

-10 1.33

12

13 14

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Static cooling, 220V 50Hz, PTC consumption incl.

EN 12900/CECOMAF 55°C 32°C 55°C

-10 1.65

Main winding

ASHRAE 55°C 32°C 32°C

Winding protector Start winding

LST g

b 8217

a1

Accessories Devices

Fig.

TLS5F

a1

103N0011 103N0018

Starting relay

a2

117U6004

PTC starting device

6.3 mm spades 4.8 mm spades

d Main winding a1 Start winding N

Cover

b

103N2010

Starting capacitor 60 µF

c

117U5014

Cord relief

d

103N1010

Protection screen for PTC

g

103N0476

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

N

118-1917 118-1918 118-1919

C

L

Winding protector

CD.42.K6.02

CK.40.B7.02

May 2001

31

TLS6F Standard Compressor R134a 220-240V 50Hz Data Sheet (Replaces CG.42.G1.02) General TLS6F

Code number

102G4620

Application

R134a SUCTION CONNECTOR

Blue stripe

Application

102G

TLS6F

4620

Approvals

Application

LBP

Evaporating temperature range Voltage range

°C

-35 to -10

V/Hz

Barcode on white background

8272-2

Compressor

DANFOSS COMPRESSORS

Yellow background

198 - 254 /50

Motor type

RSIR/CSIR

Max. ambient temperature Comp. cooling at ambient temp.

°C

38

32°C

S

38°C

S

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

Design Displacement

cm3

Oil quantity

cm3

180

g

400

cm3

1790

kg

7.3

Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment

5.70

ø16

Motor watt

125

alternative motor

110

LRA (rated after 4 sec. UL984) LST/HST

A

4.7/5.8

alternative motor Cut-in current LST/HST

35 70 100

Motor size

4.3/5.1 A

ø9

8.7/5.8

alternative motor

170 178 186 204

8.6/5.1

Resistance, main and start winding (25°C) Ω

16.0/17.0

alternative motor

18.2/15.1

D

222 176

E

EN 60335-2-34 with Annex AA

° 31.5 28°

30°

Approvals

C

B

169

C

6.2 ±0.09

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

5.0 +0.12/+0.20

Compressors on a pallet

pcs.

125

105 107

105

173

8244

45°

102

June 2001

32

CG.42.G2.02

CK.40.B7.02

71

location/I.D. mm

A

51 20° °

Suction connector

A B

mm

157 60.5 66

Height

29

Dimensions

96 117

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C TLS6F

-35 58

-30 77

-25 104

watt -23.3 115

-20 139

-15 183

-10 235

HST c

Capacity (ASHRAE) Comp.\°C TLS6F

-35 71

-30 95

watt -25 128

-23.3 142

-20 172

-15 226

-10 290 b

Power consumption Comp.\°C TLS6F

-35 84

-30 101

watt -25 119

-23.3 125

-20 138

-15 159

8219

-10 181

a2 d

Current consumption Comp.\°C TLS6F

-35 0.78

-30 0.82

A -25 0.86

-23.3 0.88

-20 0.92

-15 0.99

-10 1.08

c 11

10

COP (EN 12900/CECOMAF) Comp.\°C TLS6F

-35 0.69

W/W

-30 0.76

-25 0.87

-23.3 0.92

-20 1.01

-15 1.15

-30 0.94

-25 1.08

-23.3 1.13

-20 1.24

-15 1.42

COP (ASHRAE) Comp.\°C TLS6F

-35 0.85

-10 1.30

12

13 14

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Static cooling, 220V 50Hz, PTC consumption incl.

EN 12900/CECOMAF 55°C 32°C 55°C

-10 1.60

Main winding

ASHRAE 55°C 32°C 32°C

Winding protector Start winding

LST g

b 8217

a1

Accessories Devices

Fig.

TLS6F

a1

103N0011 103N0018

Starting relay

a2

117U6004

PTC starting device

6.3 mm spades 4.8 mm spades

d Main winding a1 Start winding N

Cover

b

103N2010

Starting capacitor 60 µF

c

117U5014

Cord relief

d

103N1010

Protection screen for PTC

g

103N0476

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

N

118-1917 118-1918 118-1919

C

L

Winding protector

CG.42.G2.02

CK.40.B7.02

June 2001

33

TLS7F Standard Compressor R134a 220-240V 50Hz Data Sheet (Replaces CG.42.H1.02) General TLS7F

Code number

102G4720

Application

R134a SUCTION CONNECTOR

Blue stripe

Application

102G

TLS7F

4720

Approvals

Application

LBP

Evaporating temperature range Voltage range

°C

-35 to -10

V/Hz

Barcode on white background

8272-3

Compressor

DANFOSS COMPRESSORS

Yellow background

198 - 254 /50

Motor type

RSIR/CSIR

Max. ambient temperature

°C

Comp. cooling at ambient temp.

38*

32°C

S

38°C

S

S O F1

* run capacitor 4 µF compulsory in 38°C ambient temperature

F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

Design Displacement

cm3

Oil quantity

cm3

180

g

400

cm3

1790

kg

7.5

Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment

6.49

ø16

Motor watt

LRA (rated after 4 sec. UL984) LST/HST

140

A

5.4/5.7

Cut-in current LST/HST

A

9.7/5.7

Resistance, main and start winding (25°C)



14.5/14.8

Dimensions Height

mm

location/I.D. mm

A

173

B

169

C

6.2 ±0.09

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

5.0 +0.12/+0.20

170 178 186 204

C

D

222 176

E ° 31.5 28°

Suction connector

ø9

EN 60335-2-34 with Annex AA

30°

Approvals

35 70 100

Motor size

Compressors on a pallet

pcs.

105

105 107

A B

125

102

June 2001

34

CG.42.H2.02

CK.40.B7.02

71

29

51 20° °

45°

157 60.5 66

8244

96 117

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C TLS7F

-35 66

-30 89

watt

-25 120

-23.3 133

-20 160

-15 208

-10 264

-25 148

-23.3 163

-20 197

-15 256

-10 326

Capacity (ASHRAE) Comp.\°C TLS7F

-35 81

-30 109

HST c

watt

b

Power consumption Comp.\°C TLS7F

-35 97

-30 116

8219

watt -25 136

-23.3 143

-20 158

-15 182

a2

-10 207 d

Current consumption Comp.\°C TLS7F

-35 0.87

-30 0.91

A -25 0.96

-23.3 0.98

-20 1.03

-15 1.11

-10 1.20

c 11

10

COP (EN 12900/CECOMAF) Comp.\°C TLS7F

-35 0.68

W/W

-30 0.77

-25 0.88

-23.3 0.92

-20 1.01

-15 1.14

-30 0.94

-25 1.09

-23.3 1.14

-20 1.24

-15 1.41

COP (ASHRAE) Comp.\°C TLS7F

-35 0.84

12

-10 1.28

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Static cooling, 220V 50Hz, PTC consumption incl.

EN 12900/CECOMAF 55°C 32°C 55°C

Main winding

-10 1.57

ASHRAE 55°C 32°C 32°C

Winding protector Start winding

LST g

Accessories

b

Devices

Fig.

TLS7F

PTC starting device

6.3 mm spades 4.8 mm spades

a1

103N0011 103N0018

PTC starting device

6.3 mm spades a1** 4.8 mm spades

103N0016* 103N0021*

Starting relay

a2

Cover

b

103N2010

c

117U5014

Cord relief

d

103N1010

Protection screen for PTC

g 6.3 mm spades 4.8 mm spades

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

8217

a1 d Main winding a1 Start winding

117U6000

Starting capacitor 60 µF

Run capacitor 4 µF

13 14

N

103N0476

N

117-7117* 117-7119* 118-1917 118-1918 118-1919

C

L

Winding protector

* run capacitor 4 µF compulsory in 38°C ambient temperature ** with connector for RC

2

August 2003

CG.42.H2.02

CK.40.B7.02

June 2001

35

NL6F Standard Compressor R134a 220-240V 50Hz Data Sheet (Replaces CD.43.P5.02) General NL6F

Code number

105G6606

105G

NL6F Application

R134a

Blue stripe Approvals

Application Application Evaporating temperature range Voltage range

°C V/Hz

LBP

Barcode on white background

-35 to -10

Yellow background

6606

DANFOSS COMPRESSORS

8273-2

Compressor

198 - 254 /50

Motor type

RSIR/CSIR

Max. ambient temperature Comp. cooling at ambient temp.

°C

38

32°C

S

38°C

S

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

Design Displacement

cm3

Oil quantity

cm3

320

g

400

cm3

2130

kg

9.3

Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment

6.13

204 170

Motor watt

LRA (rated after 4 sec. UL984) LST/HST

125

A

5.0/5.0

Cut-in current LST/HST

A

9.6/5.0

Resistance, main and start winding (25°C)



16.0/13.6

Approvals

100 70

Motor size

ø16

EN 60335-2-34 with Annex AA

178

D

205

E

Dimensions

C

6.2 ±0.09

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

5.0 +0.12/+0.20

pcs.

A B

102.5

C

80

75.5

181

location/I.D. mm

25°

B Suction connector

Compressors on a pallet

188

15°

A

35°

mm

93.5

Height

254

113

January 2003

36

CD.43.P6.02

CK.40.B7.02

27°

47°

54 78

51°

72

166

60.5

8248

119 127

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C NL6F

-35 52

-30 77

-25 110

watt -23.3 123

-20 151

-15 200

-10 258

HST c

Capacity (ASHRAE) Comp.\°C NL6F

-35 64

-30 95

watt -25 135

-23.3 151

-20 186

-15 247

-10 318 b

Power consumption Comp.\°C NL6F

-35 80

-30 98

watt -25 118

-23.3 125

-20 139

-15 161

8219

-10 185

a2 d

Current consumption Comp.\°C NL6F

-35 0.78

-30 0.81

A -25 0.86

-23.3 0.88

-20 0.92

-15 0.99

-10 1.08

c 11

10

COP (EN 12900/CECOMAF) Comp.\°C NL6F

-35 0.65

W/W

-30 0.78

-25 0.93

-23.3 0.99

-20 1.09

-15 1.24

-30 0.96

-25 1.15

-23.3 1.21

-20 1.34

-15 1.53

COP (ASHRAE) Comp.\°C NL6F

-35 0.80

-10 1.39

12

13 14

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Static cooling, 220V 50Hz, PTC consumption incl.

EN 12900/CECOMAF 55°C 32°C 55°C

-10 1.72

Main winding

ASHRAE 55°C 32°C 32°C

Winding protector Start winding

LST g

b 8217

a1

Accessories Devices

Fig.

NL6F

a1

103N0011 103N0018

Starting relay

a2

117U6004 103N2010

PTC starting device

6.3 mm spades 4.8 mm spades

Cover

b

Starting capacitor 80 µF

c

117U5015

Cord relief

d

103N1010

Protection screen for PTC

g

103N0476

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

d Main winding a1 Start winding N

N

118-1917 118-1918 118-1919

C

L

Winding protector

CD.43.P6.02

CK.40.B7.02

January 2003

37

NL7F Standard Compressor R134a 220-240V 50Hz Data Sheet (Replaces CG.43.K1.02) General NL7F

Code number

105G6706

Code number compressor with oil cooler

105G6716

105G

NL7F Application

R134a

Blue stripe Approvals

6706

Barcode on white background

Application Application

LBP

Evaporating temperature range Voltage range

°C

-35 to -10

V/Hz

198 - 254 /50

Motor type

RSIR/CSIR

Max. ambient temperature

°C

38

32°C

S

38°C

S

Displacement

cm3

7.27

Oil quantity

cm3

320

g

400

cm3

2180

kg

9.6

Comp. cooling at ambient temp.

DANFOSS COMPRESSORS

Yellow background

8273-4

Compressor

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

Design

Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment

204 170

Motor watt

LRA (rated after 4 sec. UL984) LST/HST

150

A

5.9/5.9

Cut-in current LST/HST

A

10.4/5.9

Resistance, main and start winding (25°C)



13.3/14.1

Approvals

100 70

Motor size

EN 60335-2-34 with Annex AA, CCIB

ø16 178 205

D

E C

C

6.2 ±0.09

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

5.0 +0.12/+0.20

Oil cooler

location/I.D. mm

F

5.0 +0.12/+0.20

A B

40 102.5 75.5

190 183

93.5

location/I.D. mm

A B

15°

Suction connector

mm

35°

Height

25°

Dimensions

254

F 8249

72

51°

113

August 2001

38

CG.43.K2.02

CK.40.B7.02

27°

47°

40 54 78

80 60.5

pcs.

166

Compressors on a pallet

119 127

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C NL7F

-35 71

-30 99

-25 136

watt -23.3 151

-20 182

-15 238

-10 303

HST c

Capacity (ASHRAE) Comp.\°C NL7F

-35 87

-30 122

watt -25 167

-23.3 186

-20 225

-15 293

-10 374 b

Power consumption Comp.\°C NL7F

-35 97

-30 121

watt -25 146

-23.3 155

-20 173

-15 201

8219

-10 232

a2 d

Current consumption Comp.\°C NL7F

-35 0.92

-30 0.96

A -25 1.02

-23.3 1.04

-20 1.10

-15 1.20

-10 1.33

c 11

10

COP (EN 12900/CECOMAF) Comp.\°C NL7F

-35 0.73

W/W

-30 0.82

-25 0.93

-23.3 0.97

-20 1.06

-15 1.18

-10 1.31

-30 1.01

-25 1.15

-23.3 1.20

-20 1.30

-15 1.46

-10 1.61

COP (ASHRAE) Comp.\°C NL7F

-35 0.90

12

13 14

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Static cooling, 220V 50Hz, PTC consumption incl.

EN 12900/CECOMAF 55°C 32°C 55°C

Main winding

ASHRAE 55°C 32°C 32°C

Winding protector Start winding

LST g

b 8217

a1

Accessories Devices

Fig.

NL7F

a1

103N0011 103N0018

Starting relay

a2

117U6000 103N2010

PTC starting device

6.3 mm spades 4.8 mm spades

Cover

b

Starting capacitor 80 µF

c

117U5015

Cord relief

d

103N1010

Protection screen for PTC

g

103N0476

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

d Main winding a1 Start winding N

N

118-1917 118-1918 118-1919

C

L

Winding protector

CG.43.K2.02

CK.40.B7.02

August 2001

39

NL8F Standard Compressor R134a 220-240V 50Hz Data Sheet (Replaces CD.43.J5.02) General NL8F

Code number

105G6822

Application Application

LBP

Evaporating temperature range Voltage range

°C

-35 to -10

V/Hz

105G

NL8F Application

R134a

Blue stripe Approvals

6822

Barcode on white background

DANFOSS COMPRESSORS

Yellow background

8273-5

Compressor

198 - 254 /50

Motor type

RSIR/CSIR

Max. ambient temperature Comp. cooling at ambient temp.

°C

38

32°C

S

38°C

S

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

Design Displacement

cm3

7.95

Oil quantity

cm3

320

Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment

g

400

cm3

2230

kg

9.8 204 170

Motor watt

LRA (rated after 4 sec. UL984) LST/HST

175

A

6.6/7.9

Cut-in current LST/HST

A

10.9/7.9

Resistance, main and start winding (25°C)



10.7/13.0

Approvals

100 70

Motor size

ø16

EN 60335-2-34 with Annex AA

178

D

205

E

Dimensions

6.2 ±0.09

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

5.0 +0.12/+0.20

Compressors on a pallet

pcs.

A B

102.5

191

C

80

75.5

B

25°

197

15°

location/I.D. mm

A

35°

Suction connector

C mm

93.5

Height

254

113

June 2001

40

CD.43.J6.02

CK.40.B7.02

27°

47°

54 78

51°

72

166

60.5

8248

119 127

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C NL8F

-35 82

-30 112

-25 149

watt -23.3 163

-20 194

-15 249

-10 317

HST c

Capacity (ASHRAE) Comp.\°C NL8F

-35 101

-30 139

watt -25 184

-23.3 201

-20 240

-15 308

-10 392 b

Power consumption Comp.\°C NL8F

-35 116

-30 134

watt -25 154

-23.3 162

-20 177

-15 203

8219

-10 232

a2 d

Current consumption Comp.\°C NL8F

-35 0.92

-30 0.98

A -25 1.04

-23.3 1.07

-20 1.13

-15 1.22

-10 1.34

c 11

10

COP (EN 12900/CECOMAF) Comp.\°C NL8F

-35 0.70

W/W

-30 0.84

-25 0.97

-23.3 1.01

-20 1.09

-15 1.23

-30 1.04

-25 1.19

-23.3 1.25

-20 1.35

-15 1.52

COP (ASHRAE) Comp.\°C NL8F

-35 0.87

-10 1.37

12

13 14

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Static cooling, 220V 50Hz, PTC consumption incl.

EN 12900/CECOMAF 55°C 32°C 55°C

-10 1.69

Main winding

ASHRAE 55°C 32°C 32°C

Winding protector Start winding

LST g

b 8217

a1

Accessories Devices

Fig.

NL8F

a1

103N0011 103N0018

Starting relay

a2

117U6001 103N2010

PTC starting device

6.3 mm spades 4.8 mm spades

Cover

b

Starting capacitor 80 µF

c

117U5015

Cord relief

d

103N1010

Protection screen for PTC

g

103N0476

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

d Main winding a1 Start winding N

N

118-1917 118-1918 118-1919

C

L

Winding protector

CD.43.J6.02

CK.40.B7.02

June 2001

41

NL9F Standard Compressor R134a 220-240V 50Hz Data Sheet (Replaces CG.43.M1.02) General NL9F 105G6802

Code number

105G6804*)

Code number compressor with oil cooler

105G

NL9F

Code number

Application

R134a

Blue stripe Approvals

105G6812 )

* Performance data established on 8.2 mm suction line. Restrictions due to 6.2 mm suction line can affect system performance.

6802

Barcode on white background

8273

Compressor

DANFOSS COMPRESSORS

Yellow background

Application Application

LBP

Evaporating temperature range Voltage range

°C

-35 to -10

V/Hz

S O F1

198 - 254 /50

Motor type

RSIR/CSIR

Max. ambient temperature Comp. cooling at ambient temp.

°C

38

32°C

S

38°C

S

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

F2

204 170

Design Displacement

cm3

Oil quantity

cm3

320

g

400

cm3

2280

kg

10.0

Weight without electrical equipment

ø16

D

Motor watt

A B

EN 60335-2-34 with Annex AA

105G6812 mm

A B

8249

191

location/I.D. mm

C 8.2 ±0.09

8.2 ±0.09

Process connector

location/I.D. mm

D 6.2 ±0.09

6.2 ±0.09

6.2 ±0.09

Discharge connector

location/I.D. mm

E 6.2 ±0.09

6.2 ±0.09

5.0 +0.12/+0.20

Oil cooler

location/I.D. mm

F 6.2 ±0.09

August 2001

pcs.

F

197

Suction connector

Compressors on a pallet

254

105G6802 105G6804

80

CG.43.M2.02

CK.40.B7.02

6.2 ±0.09

166

Dimensions

40 102.5 75.5

10.7/13.0

25°

10.9/7.9



15°

A

Resistance, main and start winding (25°C)

35°

Cut-in current LST/HST

Approvals

42

C

6.6/7.9

93.5

A

60.5

LRA (rated after 4 sec. UL984) LST/HST

E

175

51°

72

Motor size

Height

178 205

113

27°

47°

40 54 78

Free gas vol. in compressor

100 70

Maximum refrigerant charge

8.35

119 127

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C NL9F

-35 80

-30 112

-25 155

watt -23.3 172

-20 208

-15 272

-10 346

HST c

Capacity (ASHRAE) Comp.\°C NL9F

-35 98

-30 138

watt -25 191

-23.3 212

-20 256

-15 335

-10 427 b

Power consumption Comp.\°C NL9F

-35 117

-30 141

watt -25 167

-23.3 176

-20 195

-15 225

8219

-10 257

a2 d

Current consumption Comp.\°C NL9F

-35 0.92

-30 0.99

A -25 1.08

-23.3 1.11

-20 1.18

-15 1.29

-10 1.41

c 11

10

COP (EN 12900/CECOMAF) Comp.\°C NL9F

-35 0.68

W/W

-30 0.80

-25 0.93

-23.3 0.98

-20 1.07

-15 1.21

-10 1.35

-30 0.98

-25 1.14

-23.3 1.20

-20 1.32

-15 1.49

-10 1.66

COP (ASHRAE) Comp.\°C NL9F

-35 0.84

12

13 14

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Static cooling, 220V 50Hz, PTC consumption incl.

EN 12900/CECOMAF 55°C 32°C 55°C

Main winding

ASHRAE 55°C 32°C 32°C

Winding protector Start winding

LST g

b 8217

a1

Accessories Devices

d

Fig.

NL9F

a1

103N0011 103N0018

Starting relay

a2

117U6001 103N2010

PTC starting device

6.3 mm spades 4.8 mm spades

Cover

b

Starting capacitor 80 µF

c

117U5015

Cord relief

d

103N1010

Protection screen for PTC

g

103N0476

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

Main winding a1 Start winding N

N

118-1917 118-1918 118-1919

C

L

Winding protector

CG.43.M2.02

CK.40.B7.02

August 2001

43

NL11F Standard Compressor R134a 220-240V 50Hz Data Sheet (Replaces CG.43.J1.02) General NL11F 105G6900

Code number

105G6901*)

Code number compressor with oil cooler

105G

NL11F

Code number

Application

R134a

Blue stripe Approvals

105G6910 )

* Performance data established on 8.2 mm suction line. Restrictions due to 6.2 mm suction line can affect system performance.

6900

Barcode on white background

8273-6

Compressor

DANFOSS COMPRESSORS

Yellow background

Application Application

LBP

Evaporating temperature range Voltage range

°C

-35 to -10

V/Hz

S O F1

198 - 254 /50

Motor type

RSIR/CSIR

Max. ambient temperature

°C

Comp. cooling at ambient temp.

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

38

32°C

O/F1

38°C

O/F1

F2

204 170

Design Displacement

cm3

Oil quantity

cm3

320

g

400

cm3

2360

kg

10.7

Weight without electrical equipment

ø16

D

Motor

8.2/14.7

A B

EN 60335-2-34 with Annex AA

105G6910 mm

A

105G6900 105G6901

B

197

location/I.D. mm

C 8.2 ±0.09

8.2 ±0.09

Process connector

location/I.D. mm

D 6.2 ±0.09

6.2 ±0.09

6.2 ±0.09

Discharge connector

location/I.D. mm

E 6.2 ±0.09

6.2 ±0.09

5.0 +0.12/+0.20

Oil cooler

location/I.D. mm

F 6.2 ±0.09

August 2001

pcs.

F 8249

Suction connector

Compressors on a pallet

254

203

80

CG.43.J2.02

CK.40.B7.02

6.2 ±0.09

166

Dimensions

40 102.5 75.5

13.6/10.4



25°

A

Resistance, main and start winding (25°C)

15°

Cut-in current LST/HST

35°

9.2/10.4

Approvals

44

C

A

60.5

LRA (rated after 4 sec. UL984) LST/HST

E

235

93.5

watt

51°

72

Motor size

Height

178 205

113

27°

47°

40 54 78

Free gas vol. in compressor

100 70

Maximum refrigerant charge

11.15

119 127

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C NL11F

-35 102

-30 144

-25 200

watt -23.3 223

-20 271

-15 356

-10 455

HST c

Capacity (ASHRAE) Comp.\°C NL11F

-35 125

-30 177

watt -25 246

-23.3 274

-20 334

-15 438

-10 561 b

Power consumption Comp.\°C NL11F

-35 146

-30 178

watt -25 212

-23.3 224

-20 248

-15 286

8219

-10 325

a2 d

Current consumption Comp.\°C NL11F

-35 1.40

-30 1.46

A -25 1.54

-23.3 1.57

-20 1.64

-15 1.75

-10 1.89

c 11

10

COP (EN 12900/CECOMAF) Comp.\°C NL11F

-35 0.70

W/W

-30 0.81

-25 0.94

-23.3 0.99

-20 1.09

-15 1.25

-10 1.40

-30 0.99

-25 1.16

-23.3 1.22

-20 1.34

-15 1.53

-10 1.73

COP (ASHRAE) Comp.\°C NL11F

-35 0.86

12

13 14

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Static cooling, 220V 50Hz, PTC consumption incl.

EN 12900/CECOMAF 55°C 32°C 55°C

Main winding

ASHRAE 55°C 32°C 32°C

Winding protector Start winding

LST g

b 8217

a1

Accessories Devices

Fig.

NL11F

a1

103N0011 103N0018

Starting relay

a2

117U6002 103N2010

PTC starting device

6.3 mm spades 4.8 mm spades

Cover

b

Starting capacitor 80 µF

c

117U5015

Cord relief

d

103N1010

Protection screen for PTC

g

103N0476

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

d Main winding a1 Start winding N

N

118-1917 118-1918 118-1919

C

L

Winding protector

CG.43.J2.02

CK.40.B7.02

August 2001

45

NF7FX Standard Compressor R134a 220V 50/60Hz Data Sheet (Replaces CD.43.W4.22) General NF7FX

Connector-material

Sealing

Copper-plated steel

Aluminium caps

Copper-plated steel

Rubber plugs

105G6743

Copper

Rubber plugs

105G6753

Application

105G

NF7FX

Code number Blue stripe

R134a SUCTION CONNECTOR

6743

Barcode on white background

DANFOSS COMPRESSORS

8340

Compressor

Yellow background

Application Application

LBP/MBP

Evaporating temperature range

-30 to 45 (-34.4 to 7.2)

°F (°C)

Voltage range

V/Hz

198 - 242 /50 198 - 242 /60

Motor type

CSIR

Max. ambient temperature

°F (°C)

100 (38)

Comp. cooling at ambient temp. 90°F (32°C)

50Hz: S

60Hz: F1

100°F (38°C)

50Hz: F1

60Hz: F1

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

Design cu.in. (cm3)

14.0 (400)

Free gas vol. in compressor housing fl.oz. (cm3)

79.7 (2360)

Weight without electrical equipment

23.0 (10.5)

lbs. (kg)

27°

51°

4.45"(113)

Motor watt

340

LRA (rated after 4 sec.UL984) HST

A

15.8

Cut-in current HST

A

4.69"(119) 5.00"(127)

8.10"(205)

D

15.8 A B

Dimensions B

7.76 (197)

Suction connector

location/I.D. in. (mm) C 0.320-0.327 (8.2±0.09)

Process connector

location/I.D. in. (mm) D 0.252-0.259 (6.5±0.09)

Discharge connector

location/I.D. in. (mm) E

Compressors on a pallet

pcs.

0.252-0.259 (6.5±0.09) 80

9.92"(252) 8.03"(204) 6.70"(170)

1.38"(35)

8.00 (203)

5.20"(132) 4.00"(101.6) 2.76"(70)

in. (mm) A

2.97"(75.5)

EN 60335-2-34 with Annex AA

4.04"(102.5)

-

Approvals (105G6753)

15°

Approvals (105G6743)

25°

5.8/12.6

35°

Resistance, main and start winding (77°F) Ω

Height

E C

3.68"(93.5)

Motor size

47°

(54)

10.8 (320)

oz. (g)

Maximum refrigerant charge

3.01"(78)

fl.oz. (cm )

Oil quantity

2.13"

0.44 (7.27)

3

6.54"(166) 2.83"(72) 2.34" (59.5)

Displacement

8367

ø0.75"(19) ø0.63"(16) ø0.38"(9.7) 6.50"(165) 7.32"(186)

August 2003

46

CD.43.W5.22

CK.40.B7.02

1

August 2003

Capacity at LBP conditions (ASHRAE) Comp.\°F -30 Comp.\°C -34.4 NF7FX 341

-20 -28.9 496

-13 -25 630

-10 -23.3 696

Btu/h

0 -17.8 943

10 -12.2 1255

20 -6.7 1630

30 -1.1 2086

40 4.4 2604

10 -12.2 1117

20 -6.7 1450

30 -1.1 1854

40 4.4 2312

45 7.2 2899

Capacity at MBP conditions (ASHRAE) Comp.\°F -30 Comp.\°C -34.4 NF7FX 304

-20 -28.9 442

-13 -25 562

-10 -23.3 620

Btu/h

0 -17.8 840

45 7.2 2573

Capacity (EN 12900/CECOMAF) Comp.\°F -30 Comp.\°C -34.4 NF7FX 82

-20 -28.9 119

-13 -25 151

-10 -23.3 167

0 -17.8 226

10 -12.2 301

20 -6.7 390

30 -1.1 498

40 4.4 622

-20 -28.9 158

-13 -25 176

-10 -23.3 184

0 -17.8 209

10 -12.2 235

20 -6.7 261

30 -1.1 287

40 4.4 314

45 7.2 327

-13 -25 1.76

-10 -23.3 1.78

0 -17.8 1.83

10 -12.2 1.89

20 -6.7 1.95

30 -1.1 2.02

40 4.4 2.10

45 7.2 2.14

a2

-20 -28.9 3.13

-13 -25 3.58

Btu/Wh

-10 -23.3 3.79

0 -17.8 4.52

10 -12.2 5.36

20 -6.7 6.27

30 -1.1 7.29

40 4.4 8.35

-20 -28.9 2.80

-13 -25 3.19

45 7.2 8.90

Btu/Wh

-10 -23.3 3.37

0 -17.8 4.02

10 -12.2 4.76

20 -6.7 5.56

30 -1.1 6.46

40 4.4 7.36

-10 -23.3 0.91

0 -17.8 1.08

10 -12.2 1.28

20 -6.7 1.49

30 -1.1 1.73

40 4.4 1.98

COP (EN 12900/CECOMAF) Comp.\°F -30 Comp.\°C -34.4 NF7FX 0.61

b

c

A

-20 -28.9 1.73

EER at MBP conditions (ASHRAE) Comp.\°F -30 Comp.\°C -34.4 NF7FX 2.27

dc

watt

EER at LBP conditions (ASHRAE) Comp.\°F -30 Comp.\°C -34.4 NF7FX 2.55

8226

d

45 7.2 691

Current consumption Comp.\°F -30 Comp.\°C -34.4 NF7FX 1.70

a2

watt

Power consumption Comp.\°F -30 Comp.\°C -34.4 NF7FX 134

c

-20 -28.9 0.75

-13 -25 0.86

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Fan cooling F1, 220V 50Hz

10 12

Main winding

11 13

Start winding Thermostat

14

M

Motor protector

45 7.2 7.87

W/W

ASHRAE (LBP) 130°F (54.4°C) 90°F (32°C) 90°F (32°C)

ASHRAE (MBP) 130°F (54.4°C) 95°F (35°C) 115°F (46°C)

45 7.2 2.11

EN12900/CECOMAF 55°C (131°F) 32°C (90°F) 55°C (131°F)

Accessories Devices

Fig.

Star ting relay (Klixon incl.) Protector 3/4"

Texas Instruments

a2

NF7FX 117U4140 MRP59EN-6

Star ting capacitor 125 µF

c

117U5018

Cover

b

117U1023

Cord relief

d

117U0349

Cord relief capacitor

dc

117U0349

Ø in. (mm) 5 /8 (16) 3 /4 (19) 5 /8 (16)

118-1946 118-1949 118-1947

Mounting accessories Bolt joint for one compressor Bolt joint for one compressor Snap-on for one compressor

2

August 2003

CD.43.W5.22

CK.40.B7.02

August 2003

47

NF9FX Standard Compressor R134a 220V 50Hz Data Sheet (Replaces CD.43.Z2.22) General

Copper-plated steel

Aluminium caps

Copper-plated steel

Rubber plugs

Application Blue stripe

Rubber plugs

Copper

Rubber plugs

R134a SUCTION CONNECTOR

105G6842 (UL-recognized) 105G6952* (UL-recognized)

Copper-plated steel

105G

NF9FX

Code number

6843

Barcode on white background

105G6843

DANFOSS COMPRESSORS

Yellow background

105G6953*

R

NF9FX 220V-50Hz 1PH

* Oil cooler version

Application LBP/MBP

V/Hz

198 - 242 /50

Motor type

CSIR

Max. ambient temperature

°F (°C)

100 (38)

Comp. cooling at ambient temp. 90°F (32°C)

O/F1

100°F (38°C)

O/F1

Design cu.in. (cm3)

Displacement

0.51 (8.35)

3

fl.oz. (cm )

Oil quantity Maximum refrigerant charge

10.8 (320)

oz. (g)

14.0 (400)

Free gas vol. in compressor housing fl.oz. (cm3)

79.7 (2360)

Weight without electrical equipment

23.0 (10.5)

lbs. (kg)

S O F1 F2

THERMALLY PROTECTED = Static cooling normally sufficient Approval mark = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

27°

51°

4.45"(113)

47°

(54)

Voltage range

1.57" (40)

-30 to 45 (-34.4 to 7.2)

°F (°C)

2.13"

Evaporating temperature range

6.54"(166) 2.83"(72) 2.34" (59.5)

Application

4.69"(119) 5.00"(127)

8.10"(205)

D

E

Motor

5.8/12.6

Approvals (105G6842, 105G6852)

UL984/CSA-C22.2

Approvals (105G6843, 105G6853)

-

A B

9.92"(252) 8.03"(204) 6.70"(170)

8.00 (203)

B

7.76 (197)

Suction connector

location/I.D. in. (mm) C 0.320-0.327 (8.2±0.09)

Process connector

location/I.D. in. (mm) D 0.252-0.259 (6.5±0.09)

Discharge connector

location/I.D. in. (mm) E

0.252-0.259 (6.5±0.09)

Oil cooler

location/I.D. in. (mm) F

0.252-0.259 (6.5±0.09)

Compressors on a pallet August 2003

48

in. (mm) A

pcs.

80 CD.43.Z3.22

CK.40.B7.02

1.38"(35)

Height

5.20"(132) 4.00"(101.6) 2.76"(70)

Dimensions

2.97"(75.5)

15.8

Resistance, main and start winding (77°F) Ω

4.04"(102.5)

15.8

A

1.57" (40)

A

Cut-in current HST

25°

LRA (rated after 4 sec.UL984) HST

C

15°

340

35°

watt

3.68"(93.5)

Motor size

8340-6

Sealing

8340-2

NF9FX

Connector-material

3.01"(78)

Compressor

F 8336

ø0.75"(19) ø0.63"(16) ø0.38"(9.7) 6.50"(165) 7.32"(186)

1

August 2003

Capacity at LBP conditions (ASHRAE) Comp.\°F -30 Comp.\°C -34.4 NF 9FX 389

-20 -28.9 562

-13 -25 712

-10 -23.3 786

Btu/h

0 -17.8 1061

10 -12.2 1409

20 -6.7 1825

30 -1.1 2331

40 4.4 2912

10 -12.2 1255

20 -6.7 1624

30 -1.1 2072

40 4.4 2586

45 7.2 3237

Capacity at MBP conditions (ASHRAE) Comp.\°F -30 Comp.\°C -34.4 NF9FX 347

-20 -28.9 501

-13 -25 635

-10 -23.3 701

Btu/h

0 -17.8 945

45 7.2 2873

Capacity (EN 12900/CECOMAF) Comp.\°F -30 Comp.\°C -34.4 NF9FX 94

-20 -28.9 135

-13 -25 171

-10 -23.3 189

0 -17.8 254

10 -12.2 337

20 -6.7 436

30 -1.1 557

40 4.4 694

-20 -28.9 180

-13 -25 200

-10 -23.3 209

0 -17.8 238

10 -12.2 269

20 -6.7 299

30 -1.1 330

40 4.4 361

45 7.2 377

-20 -28.9 1.77 -20 -28.9 3.13 -20 -28.9 2.78

-13 -25 1.81

-10 -23.3 1.83

0 -17.8 1.89

10 -12.2 1.97

20 -6.7 2.05

30 -1.1 2.14

40 4.4 2.24

-20 -28.9 0.75

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Fan cooling F1, 220V 50Hz

a2

-13 -25 3.57 -13 -25 3.17

45 7.2 2.29

Btu/Wh

-10 -23.3 3.76

0 -17.8 4.46

10 -12.2 5.25

20 -6.7 6.12

30 -1.1 7.08

40 4.4 8.05

45 7.2 8.62

Btu/Wh

-10 -23.3 3.35

0 -17.8 3.97

10 -12.2 4.66

20 -6.7 5.43

30 -1.1 6.28

40 4.4 7.16

-10 -23.3 0.90

0 -17.8 1.07

10 -12.2 1.25

20 -6.7 1.46

30 -1.1 1.68

40 4.4 1.92

COP (EN 12900/CECOMAF) Comp.\°F -30 Comp.\°C -34.4 NF9FX 0.62

b

c

A

EER at MBP conditions (ASHRAE) Comp.\°F -30 Comp.\°C -34.4 NF9FX 2.30

dc

watt

EER at LBP conditions (ASHRAE) Comp.\°F -30 Comp.\°C -34.4 NF9FX 2.57

8226

d

45 7.2 771

Current consumption Comp.\°F -30 Comp.\°C -34.4 NF9FX 1.72

a2

watt

Power consumption Comp.\°F -30 Comp.\°C -34.4 NF9FX 151

c

-13 -25 0.86

10 12

Main winding

11 13

Start winding Thermostat

14

M

Motor protector

45 7.2 7.62

W/W

ASHRAE (LBP) 130°F (54.4°C) 90°F (32°C) 90°F (32°C)

ASHRAE (MBP) 130°F (54.4°C) 95°F (35°C) 115°F (46°C)

45 7.2 2.04

EN12900/CECOMAF 55°C (131°F) 32°C (90°F) 55°C (131°F)

Accessories Devices

Fig.

Star ting relay (Klixon incl.) Protector 3/4"

Texas Instruments

a2

NF9FX 117U4140 MRP59EN-6

Star ting capacitor 125 µF

c

Cover (105G6842, 105G6852)

b

117U1021

Cover (105G6843, 105G6853)

b

117U1023

117U5018

Cord relief

d

117U0349

Cord relief capacitor

dc

117U0349

Ø in. (mm) 5 /8 (16) 3 /4 (19) 5 /8 (16)

118-1946 118-1949 118-1947

Mounting accessories Bolt joint for one compressor Bolt joint for one compressor Snap-on for one compressor

2

August 2003

CD.43.Z3.22

CK.40.B7.02

August 2003

49

NF10FX Standard Compressor R134a 220V 50/60Hz Data Sheet (Replaces CG.43.A3.22) General NF10FX

Connector-material

Sealing

Copper-plated steel

Aluminium caps

Application Blue stripe

Copper-plated steel 50Hz

Rubber plugs

105G6847 (UL-recognized)

Copper-plated steel 50/60Hz

Rubber plugs

105G6846

Copper

Rubber plugs

105G

NF10FX

Code number

R134a SUCTION CONNECTOR

6847

Barcode on white background

8340-3

Compressor

DANFOSS COMPRESSORS

Yellow background R

Application LBP/MBP

Evaporating temperature range Voltage range

NF10FX 220V-50Hz 1PH

-30 to 45 (-34.4 to 7.2)

°F (°C)

V/Hz 105G6846/47: 198 - 242 /50 105G6846: 198 - 242 /60

Motor type

CSIR

Max. ambient temperature

°F (°C)

100 (38)

Comp. cooling at ambient temp. 90°F (32°C)

50Hz: F1

60Hz: F2

100°F (38°C)

50Hz: F2

60Hz: F2

S O F1 F2

THERMALLY PROTECTED = Static cooling normally sufficient Approval mark = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

8340-7

Application

10.8 (320)

oz. (g)

16.1 (460)

Maximum refrigerant charge

0.62 (10.09)

Free gas vol. in compressor housing fl.oz. (cm3)

79.7 (2360)

Weight without electrical equipment

23.0 (10.5)

lbs. (kg)

4.45"(113)

Cut-in current HST

A

20.0 4.5/12.8

Approvals (105G6847)

UL984/CSA-C22.2

Approvals (105G6846)

-

A B

15°

Resistance, main and start winding (77°F) Ω

C

4.04"(102.5)

20.0 25°

450

A

9.92"(252) 8.03"(204) 6.70"(170)

7.76 (197)

location/I.D. in. (mm) C 0.320-0.327 (8.2±0.09)

Process connector

location/I.D. in. (mm) D 0.252-0.259 (6.5±0.09)

Compressors on a pallet

August 2003

location/I.D. in. (mm) E pcs.

1.38"(35)

8.00 (203)

B Suction connector

Discharge connector

50

in. (mm) A

5.20"(132) 4.00"(101.6) 2.76"(70)

Dimensions Height

CG.43.A4.22

CK.40.B7.02

8367

ø0.75"(19) ø0.63"(16) ø0.38"(9.7)

0.252-0.259 (6.5±0.09) 80

E

35°

watt

LRA (rated after 4 sec.UL984) HST

4.69"(119) 5.00"(127)

3.68"(93.5)

Motor size

47°

8.10"(205)

D

Motor

27°

51°

(54)

fl.oz. (cm3)

3.01"(78)

Oil quantity

2.13"

cu.in. (cm3)

2.97"(75.5)

Displacement

6.54"(166) 2.83"(72) 2.34" (59.5)

Design

6.50"(165) 7.32"(186)

1

August 2003

Capacity at LBP conditions (ASHRAE) Comp.\°F -30 Comp.\°C -34.4 NF10FX 449

-20 -28.9 648

-13 -25 821

-10 -23.3 905

Btu/h

0 -17.8 1222

10 -12.2 1623

20 -6.7 2104

30 -1.1 2693

40 4.4 3374

10 -12.2 1445

20 -6.7 1872

30 -1.1 2394

40 4.4 2996

45 7.2 3759

Capacity at MBP conditions (ASHRAE) Comp.\°F -30 Comp.\°C -34.4 NF10FX 400

-20 -28.9 578

-13 -25 732

-10 -23.3 807

Btu/h

0 -17.8 1089

45 7.2 3336

Capacity (EN 12900/CECOMAF) Comp.\°F -30 Comp.\°C -34.4 NF10FX 108

-20 -28.9 156

-13 -25 197

-10 -23.3 217

0 -17.8 293

10 -12.2 389

20 -6.7 503

30 -1.1 643

40 4.4 804

-20 -28.9 248

-13 -25 272

-10 -23.3 283

0 -17.8 318

10 -12.2 354

20 -6.7 390

30 -1.1 426

40 4.4 462

45 7.2 481

-20 -28.9 2.70 -20 -28.9 2.61 -20 -28.9 2.33

-13 -25 2.73

-10 -23.3 2.75

0 -17.8 2.81

10 -12.2 2.88

20 -6.7 2.96

30 -1.1 3.05

40 4.4 3.15

-13 -25 3.02 -13 -25 2.69

45 7.2 3.21

Btu/Wh

-10 -23.3 3.20

0 -17.8 3.85

10 -12.2 4.60

20 -6.7 5.42

30 -1.1 6.34

40 4.4 7.33

45 7.2 7.86

Btu/Wh

-10 -23.3 2.85

0 -17.8 3.42

10 -12.2 4.08

20 -6.7 4.80

30 -1.1 5.62

40 4.4 6.49

-10 -23.3 0.77

0 -17.8 0.92

10 -12.2 1.10

20 -6.7 1.29

30 -1.1 1.51

40 4.4 1.74

COP (EN 12900/CECOMAF) Comp.\°F -30 Comp.\°C -34.4 NF10FX 0.51

-20 -28.9 0.63

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Fan cooling F1, 220V 50Hz

b a2 c

A

EER at MBP conditions (ASHRAE) Comp.\°F -30 Comp.\°C -34.4 NF10FX 1.87

dc

watt

EER at LBP conditions (ASHRAE) Comp.\°F -30 Comp.\°C -34.4 NF10FX 2.09

8226

d

45 7.2 895

Current consumption Comp.\°F -30 Comp.\°C -34.4 NF10FX 2.65

a2

watt

Power consumption Comp.\°F -30 Comp.\°C -34.4 NF10FX 214

c

-13 -25 0.72

10 12

Main winding

11 13

Start winding Thermostat

14

M

Motor protector

45 7.2 6.94

W/W

ASHRAE (LBP) 130°F (54.4°C) 90°F (32°C) 90°F (32°C)

ASHRAE (MBP) 130°F (54.4°C) 95°F (35°C) 115°F (46°C)

45 7.2 1.86

EN12900/CECOMAF 55°C (131°F) 32°C (90°F) 55°C (131°F)

Accessories Devices

Fig.

Star ting relay (Klixon incl.) Protector 3/4"

Texas Instruments

a2

NF10FX 117U4139 MRP59EN-6

Star ting capacitor 125 µF

c

Cover (105G6847)

b

117U1021

Cover (105G6846)

b

117U1023

117U5018

Cord relief

d

117U0349

Cord relief capacitor

dc

117U0349

Ø in. (mm) 5 /8 (16) 3 /4 (19) 5 /8 (16)

118-1946 118-1949 118-1947

Mounting accessories Bolt joint for one compressor Bolt joint for one compressor Snap-on for one compressor

2

August 2003

CG.43.A4.22

CK.40.B7.02

August 2003

51

NF11FX Standard Compressor R134a 220V 50Hz Data Sheet (Replaces CG.43.C2.22) General NF11FX

Connector-material

Sealing

Copper-plated steel

Aluminium caps

Copper-plated steel

Rubber plugs

Copper

Rubber plugs

Application

105G

NF11FX

Code number Blue stripe

R134a SUCTION CONNECTOR

105G6944

6944

Barcode on white background

DANFOSS COMPRESSORS

8340-4

Compressor

Yellow background

Application Application

LBP/MBP

Evaporating temperature range

-30 to 45 (-34.4 to 7.2)

°F (°C)

Voltage range

V/Hz

198 - 242 /50

Motor type

CSIR 100 (38)

100°F (38°C)

F2

S O F1 F2

Design Displacement

cu.in. (cm3)

0.68 (11.15)

Oil quantity

fl.oz. (cm3)

10.8 (320)

oz. (g)

14.0 (400)

Free gas vol. in compressor housing fl.oz. (cm3)

79.7 (2360)

Weight without electrical equipment

23.0 (10.5)

lbs. (kg)

Motor

27°

51°

4.45"(113)

watt

450

LRA (rated after 4 sec.UL984) HST

A

20.0

Cut-in current HST

A

7.76 (197)

location/I.D. in. (mm) C 0.320-0.327 (8.2±0.09)

Process connector

location/I.D. in. (mm) D 0.252-0.259 (6.5±0.09)

Discharge connector

location/I.D. in. (mm) E

0.252-0.259 (6.5±0.09) 80

25°

4.04"(102.5)

B Suction connector

9.92"(252) 8.03"(204) 6.70"(170)

1.38"(35)

8.00 (203)

3.68"(93.5)

in. (mm) A

15°

Dimensions

A B

35°

-

pcs.

C

4.5/12.8

Approvals

Compressors on a pallet

E

20.0

Resistance, main and start winding (77°F) Ω

Height

4.69"(119) 5.00"(127)

8.10"(205)

D

5.20"(132) 4.00"(101.6) 2.76"(70)

Motor size

47°

2.97"(75.5)

Maximum refrigerant charge

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

(54)

F2

3.01"(78)

90°F (32°C)

2.13"

°F (°C)

Comp. cooling at ambient temp.

6.54"(166) 2.83"(72) 2.34" (59.5)

Max. ambient temperature

8367

ø0.75"(19) ø0.63"(16) ø0.38"(9.7) 6.50"(165) 7.32"(186)

August 2003

52

CG.43.C3.22

CK.40.B7.02

1

August 2003

Capacity at LBP conditions (ASHRAE) Comp.\°F -30 Comp.\°C -34.4 NF11FX 496

-20 -28.9 713

-13 -25 901

-10 -23.3 993

Btu/h

0 -17.8 1336

10 -12.2 1768

20 -6.7 2280

30 -1.1 2907

40 4.4 3637

10 -12.2 1575

20 -6.7 2029

30 -1.1 2584

40 4.4 3230

45 7.2 4051

Capacity at MBP conditions (ASHRAE) Comp.\°F -30 Comp.\°C -34.4 NF11FX 442

-20 -28.9 636

-13 -25 803

-10 -23.3 885

Btu/h

0 -17.8 1190

45 7.2 3595

Capacity (EN 12900/CECOMAF) Comp.\°F -30 Comp.\°C -34.4 NF11FX 119

-20 -28.9 171

-13 -25 216

-10 -23.3 238

0 -17.8 320

10 -12.2 423

20 -6.7 545

30 -1.1 694

40 4.4 867

-20 -28.9 266

-13 -25 291

-10 -23.3 302

0 -17.8 341

10 -12.2 383

20 -6.7 426

30 -1.1 470

40 4.4 512

45 7.2 533

-20 -28.9 2.72

-13 -25 2.76

-10 -23.3 2.78

0 -17.8 2.85

10 -12.2 2.94

20 -6.7 3.05

30 -1.1 3.17

40 4.4 3.29

45 7.2 3.36

-20 -28.9 2.68 -20 -28.9 2.39 -20 -28.9 0.64

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Fan cooling F2, 220V 50Hz

a2

-13 -25 3.10

Btu/Wh

-10 -23.3 3.29

0 -17.8 3.92

10 -12.2 4.62

20 -6.7 5.35

30 -1.1 6.18

40 4.4 7.10

-13 -25 2.76

45 7.2 7.60

Btu/Wh

-10 -23.3 2.93

0 -17.8 3.49

10 -12.2 4.11

20 -6.7 4.76

30 -1.1 5.50

40 4.4 6.31

-10 -23.3 0.79

0 -17.8 0.94

10 -12.2 1.10

20 -6.7 1.28

30 -1.1 1.48

40 4.4 1.69

COP (EN 12900/CECOMAF) Comp.\°F -30 Comp.\°C -34.4 NF11FX 0.50

b

c

A

EER at MBP conditions (ASHRAE) Comp.\°F -30 Comp.\°C -34.4 NF11FX 1.87

dc

watt

EER at LBP conditions (ASHRAE) Comp.\°F -30 Comp.\°C -34.4 NF11FX 2.10

8226

d

45 7.2 965

Current consumption Comp.\°F -30 Comp.\°C -34.4 NF11FX 2.68

a2

watt

Power consumption Comp.\°F -30 Comp.\°C -34.4 NF11FX 236

c

-13 -25 0.74

10 12

Main winding

11 13

Start winding Thermostat

14

M

Motor protector

45 7.2 6.75

W/W

ASHRAE (LBP) 130°F (54.4°C) 90°F (32°C) 90°F (32°C)

ASHRAE (MBP) 130°F (54.4°C) 95°F (35°C) 115°F (46°C)

45 7.2 1.81

EN12900/CECOMAF 55°C (131°F) 32°C (90°F) 55°C (131°F)

Accessories Devices

Fig.

Star ting relay (Klixon incl.) Protector 3/4"

Texas Instruments

a2

NF11FX 117U4139 MRP59EN-6

Star ting capacitor 125 µF

c

117U5018

Cover

b

117U1023

Cord relief

d

117U0349

Cord relief capacitor

dc

117U0349

Ø in. (mm) 5 /8 (16) 3 /4 (19) 5 /8 (16)

118-1946 118-1949 118-1947

Mounting accessories Bolt joint for one compressor Bolt joint for one compressor Snap-on for one compressor

2

August 2003

CG.43.C3.22

CK.40.B7.02

August 2003

53

NL10MF Standard Compressor R134a 220-240V 50/60Hz Data Sheet General NL10MF

Code number

105G6885

Code number

105G6886

Code number compressor with oil cooler

105G6887

105G

NL10MF Application

R134a

Blue stripe Approvals

6885

Barcode on white background

Application

DANFOSS COMPRESSORS

Yellow background

Application

8479

Compressor

MBP

Evaporating temperature range

°C

50Hz: -20*/-12 to 10 60Hz: -25 to 7.2

V/Hz

S O F1

187 - 254 /50 198 - 254 /60

Motor type

50Hz: RSIR F2

50/60Hz: CSIR Max. ambient temperature

°C

Comp. cooling at ambient temp.

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

43

32°C

O/F1

38°C

O/F1 (F2*)

43°C

O/F1 (F2*)

* F2 for 230-240V 50Hz nominal below -12°C evaporating temperature

204 170

Design cm3

10.10

cm3

320

g

600

3

2360

kg

10.5

ø16

Motor Motor size

watt

D

320

LRA (rated after 4 sec. UL984) LST/HST

A

13.1/16.1

Cut-in current LST/HST

A

17.1/16.1 6.1/17.5

105G6885/87 mm

A

203

B

197

254

Suction connector

location/I.D. mm

C 8.2 ±0.09

9.7 ±0.09

Process connector

location/I.D. mm

D 6.2 ±0.09

6.5 ±0.09

Discharge connector

location/I.D. mm

E 6.2 ±0.09

6.5 ±0.09

Oil cooler

location/I.D. mm

F

Compressors on a pallet

pcs.

93.5

105G6886

51°

72

6.2 ±0.09

54

27°

47°

80 113

August 2003

F 8249

166

Dimensions Height

A B

EN 60335-2-34

15°

Approvals

E C 35°

Resistance, main and start winding (25°C) Ω

178 205

40 102.5 75.5

cm

Weight without electrical equipment

25°

Free gas vol. in compressor

60.5

Maximum refrigerant charge

100 70

Displacement Oil quantity

40 54 78

Voltage range

CJ.43.A1.02

CK.40.B7.02

119 127

1

August 2003

Capacity (EN 12900/CECOMAF) Evap. temp. in °C NL10MF, 50Hz NL10MF, 60Hz

-25 226

-20 -15 -10 268* 343* 439 306 405 523

watt -6.7 513 610

-5 555 659

0 692 813

5 850 986

7.2 10 926 1028 1068

Capacity (ASHRAE) Evap. temp. in °C NL10MF, 50Hz NL10MF, 60Hz

-25 278

-25 235

c

watt -20 -15 -10 330* 422* 540 377 498 643

-6.7 631 750

-5 683 811

0 5 7.2 10 851 1046 1139 1264 1000 1213 1314

Power consumption Evap. temp. in °C NL10MF, 50Hz NL10MF, 60Hz

HST

b

watt -20 -15 -10 252* 286* 323 279 326 377

-6.7 346 413

-5 359 432

0 396 490

5 435 552

7.2 452 581

8219

10 475

a2 d

Current consumption Evap. temp. in °C NL10MF, 50Hz NL10MF, 60Hz

-25 1.64

A -20 -15 -10 2.02* 2.11* 2.21 1.79 1.97 2.17

-6.7 2.29 2.32

-5 2.33 2.40

0 2.45 2.65

5 2.59 2.93

7.2 2.66 3.07

-20 -15 -10 1.06* 1.21* 1.36 1.10 1.25 1.39

-6.7 1.48 1.48

-5 1.54 1.53

0 1.74 1.66

5 1.94 1.78

7.2 2.04 1.84

-20 -15 -10 1.30* 1.49* 1.67 1.35 1.54 1.71

-6.7 1.82 1.82

-5 1.89 1.88

0 2.14 2.04

5 2.39 2.19

7.2 2.51 2.26

COP (EN 12900/CECOMAF) Evap. temp. in °C NL10MF, 50Hz NL10MF, 60Hz

-25 0.95

c 11

10

W/W

COP (ASHRAE) Evap. temp. in °C NL10MF, 50Hz NL10MF, 60Hz

10 2.75

10 2.16

12

13 14

W/W -25 1.17

10 2.66

Test conditions EN 12900/CECOMAF ASHRAE Condensing temperature 55°C 55°C Ambient and suction gas temp. 32°C 32°C Liquid temperature 55°C 32°C 50Hz: Fan cooling F2, 220V 60Hz: Fan cooling F1, 220V * F2 for 230-240V 50Hz nominal below -12°C evaporating temperature preliminary data

Main winding

Winding protector Start winding

LST g

b 8217

a1

Accessories Devices

Fig.

NL10MF

a1

103N0011 103N0018

Star ting relay

a2

117U6022 103N2010

PTC star ting device

6.3 mm spades 4.8 mm spades

Cover

b

Star ting capacitor 125 µF

c

117U5018

Cord relief

d

103N1010

Protection screen for PTC

g

103N0476

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

118-1917 118-1918 118-1919

CJ.43.A1.02

CK.40.B7.02

d Main winding a1 Start winding N

N

C

L

Winding protector

August 2003

55

FR7.5F Standard Compressor R134a 220-240V 50Hz Data Sheet (Replaces CD.43.A7.02) General FR7.5F

Code number

103G6750

103G

FR7.5F Application

R134a

Blue stripe Approvals

Application Application Evaporating temperature range Voltage range

°C V/Hz

LBP

Barcode on white background

-35 to -10

Yellow background

6750

8274

Compressor

DANFOSS COMPRESSORS

198 - 254 /50

Motor type

RSIR/CSIR

Max. ambient temperature Comp. cooling at ambient temp.

°C

38

32°C

S

38°C

S

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

Design Displacement

cm3

Oil quantity

cm3

350

g

900

cm3

1450

kg

10.6

Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment

6.93

204 178

ø16

ø19

Motor 150 6.1/7.4

Cut-in current LST/HST

A

10.9/7.4

Resistance, main and start winding (25°C)



12.6/12.4

Approvals

D

8.2 ±0.09

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

6.2 ±0.09

25°

191

C

30°

B location/I.D. mm

pcs.

C E

196

A B 102 130

A

30°

mm

Suction connector

Compressors on a pallet

127 165 170 186 200

127

Height

ø9.7

EN 60335-2-34 with Annex AA

Dimensions

35 127 150

A

80

122.5

June 2001

56

CD.43.A8.02

CK.40.B7.02

8253

24°

40°

40°

55

156

243

32 55

watt

LRA (rated after 4 sec. UL984) LST/HST

101.6 70 60.5

Motor size

124.5 127.5

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C FR7.5F

-35 60

-30 79

-25 108

watt -23.3 120

-20 147

-15 197

-10 257

HST c

Capacity (ASHRAE) Comp.\°C FR7.5F

-35 74

watt

-30 97

-25 133

-23.3 148

-20 182

-15 243

-10 317 b

Power consumption Comp.\°C FR7.5F

-35 89

watt

-30 106

-25 126

-23.3 133

-20 148

-15 173

8219

-10 200

a2 d

Current consumption Comp.\°C FR7.5F

-35 0.80

-30 0.85

A -25 0.91

-23.3 0.94

-20 0.99

-15 1.09

-10 1.20

c 11

10

COP (EN 12900/CECOMAF) Comp.\°C FR7.5F

-35 0.68

W/W

-30 0.74

-25 0.86

-23.3 0.90

-20 0.99

-15 1.14

-10 1.29

-30 0.91

-25 1.05

-23.3 1.11

-20 1.22

-15 1.40

-10 1.59

COP (ASHRAE) Comp.\°C FR7.5F

-35 0.83

12

13 14

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Static cooling, 220V 50Hz, PTC consumption incl.

EN 12900/CECOMAF 55°C 32°C 55°C

Main winding

ASHRAE 55°C 32°C 32°C

Winding protector Start winding

LST g

b 8217

a1

Accessories Devices

d

Fig.

FR7.5F

a1

103N0011 103N0018

Starting relay

a2

117U6000 103N2010

PTC starting device

6.3 mm spades 4.8 mm spades

Main winding a1 Start winding N

Cover

b

Starting capacitor 80 µF

c

117U5015

Cord relief

d

103N1010

Protection screen for PTC

g

103N0476

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

N

118-1917 118-1918 118-1919

C

L

Winding protector

CD.43.A8.02

CK.40.B7.02

June 2001

57

FR8.5F Standard Compressor R134a 220-240V 50Hz Data Sheet (Replaces CG.43.G1.02) General FR8.5F

Code number

103G6850

103G

FR8.5F Application

R134a

Blue stripe Approvals

Application Application Evaporating temperature range Voltage range

°C V/Hz

LBP

Barcode on white background

-35 to -10

Yellow background

6850

8274-2

Compressor

DANFOSS COMPRESSORS

198 - 254 /50

Motor type

RSIR/CSIR

Max. ambient temperature Comp. cooling at ambient temp.

°C

38

32°C

S

38°C

S

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

Design Displacement

cm3

Oil quantity

cm3

350

g

900

cm3

1450

kg

10.6

Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment

7.95

204 178

ø16

ø19

Motor 175 6.8/8.1

Cut-in current LST/HST

A

11.4/8.1

Resistance, main and start winding (25°C)



10.7/13.0

Approvals

D

C

8.2 ±0.09

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

6.2 ±0.09

pcs.

A B

102 130

191

location/I.D. mm

30°

B Suction connector

C E

196

25°

A

30°

mm

Compressors on a pallet

127 165 170 186 200

127

Height

ø9.7

EN 60335-2-34 with Annex AA

Dimensions

35 127 150

A

80

122.5

June 2001

58

CG.43.G2.02

CK.40.B7.02

8253

24°

40°

40°

55

156

243

32 55

watt

LRA (rated after 4 sec. UL984) LST/HST

101.6 70 60.5

Motor size

124.5 127.5

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C FR8.5F

-35 65

-30 89

-25 124

watt -23.3 138

-20 169

-15 224

-10 289

HST c

Capacity (ASHRAE) Comp.\°C FR8.5F

-35 80

watt

-30 110

-25 153

-23.3 170

-20 208

-15 276

-10 357 b

Power consumption Comp.\°C FR8.5F

-35 96

watt

-30 120

-25 145

-23.3 154

-20 172

-15 201

8219

-10 231

a2 d

Current consumption Comp.\°C FR8.5F

-35 0.89

-30 0.96

A -25 1.04

-23.3 1.07

-20 1.14

-15 1.25

-10 1.37

c 11

10

COP (EN 12900/CECOMAF) Comp.\°C FR8.5F

-35 0.68

W/W

-30 0.75

-25 0.85

-23.3 0.90

-20 0.98

-15 1.11

-10 1.25

-30 0.92

-25 1.05

-23.3 1.10

-20 1.21

-15 1.37

-10 1.54

COP (ASHRAE) Comp.\°C FR8.5F

-35 0.83

12

13 14

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Static cooling, 220V 50Hz, PTC consumption incl.

EN 12900/CECOMAF 55°C 32°C 55°C

Main winding

ASHRAE 55°C 32°C 32°C

Winding protector Start winding

LST g

b 8217

a1

Accessories Devices

d

Fig.

FR8.5F

a1

103N0011 103N0018

Starting relay

a2

117U6001 103N2010

PTC starting device

6.3 mm spades 4.8 mm spades

Main winding a1 Start winding N

Cover

b

Starting capacitor 80 µF

c

117U5015

Cord relief

d

103N1010

Protection screen for PTC

g

103N0476

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

N

118-1917 118-1918 118-1919

C

L

Winding protector

CG.43.G2.02

CK.40.B7.02

June 2001

59

FR10F Standard Compressor R134a 220-240V 50Hz Data Sheet (Replaces CG.43.D2.02) General FR10F

Code number

103G6950

103G

FR10F Application

R134a

Blue stripe Approvals

Application Application Evaporating temperature range Voltage range

°C V/Hz

LBP

Barcode on white background

-35 to -10

Yellow background

6950

8274-3

Compressor

DANFOSS COMPRESSORS

198 - 254 /50

Motor type

RSIR/CSIR

Max. ambient temperature Comp. cooling at ambient temp.

°C

38

32°C

S

38°C

S

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

Design Displacement

cm3

Oil quantity

cm3

350

g

900

cm3

1450

kg

10.6

Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment

9.05

204 178

ø16

ø19

Motor 215

A

8.1/8.2

Cut-in current LST/HST

A

12.8/8.2

Resistance, main and start winding (25°C)



8.9/12.0

Dimensions

127 165 170 186 200

D

8.2 ±0.09

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

6.2 ±0.09

pcs.

A B

102 130

C

30°

191

location/I.D. mm

127

B Suction connector

C E

196

25°

A

30°

mm

Compressors on a pallet

ø9.7

EN 60335-2-34 with Annex AA

80

122.5

January 2003

60

CG.43.D3.02

CK.40.B7.02

8253

24°

40°

40°

55

156

243

32 55

Approvals

Height

35 127 150

watt

LRA (rated after 4 sec. UL984) LST/HST

101.6 70 60.5

Motor size

124.5 127.5

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C FR10F

-35 82

-30 103

-25 138

watt -23.3 153

-20 186

-15 248

-10 324

HST c

Capacity (ASHRAE) Comp.\°C FR10F

-35 101

watt

-30 127

-25 170

-23.3 188

-20 229

-15 306

-10 399 b

Power consumption Comp.\°C FR10F

-35 116

watt

-30 137

-25 162

-23.3 171

-20 191

-15 223

8219

-10 259

a2 d

Current consumption Comp.\°C FR10F

-35 1.04

-30 1.11

A -25 1.18

-23.3 1.21

-20 1.26

-15 1.36

-10 1.48

c 11

10

COP (EN 12900/CECOMAF) Comp.\°C FR10F

-35 0.71

W/W

-30 0.76

-25 0.85

-23.3 0.89

-20 0.98

-15 1.11

-30 0.93

-25 1.05

-23.3 1.10

-20 1.20

-15 1.37

-10 1.25

COP (ASHRAE) Comp.\°C FR10F

-35 0.87

12

13 14

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Static cooling, 220V 50Hz, PTC consumption incl.

EN 12900/CECOMAF 55°C 32°C 55°C

-10 1.54

Main winding

ASHRAE 55°C 32°C 32°C

Winding protector Start winding

LST g

b 8217

a1

Accessories Devices

d

Fig.

FR10F

a1

103N0011 103N0018

Starting relay

a2

117U6015 103N2010

PTC starting device

6.3 mm spades 4.8 mm spades

Main winding a1 Start winding N

Cover

b

Starting capacitor 80 µF

c

117U5015

Cord relief

d

103N1010

Protection screen for PTC

g

103N0476

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

N

118-1917 118-1918 118-1919

C

L

Winding protector

CG.43.D3.02

CK.40.B7.02

January 2003

61

SC15F Standard Compressor R134a 220-240V 50Hz Data Sheet (Replaces CD.44.H4.02) General SC15F

Code number

104G8500

Code number compressor with oil cooler

104G8510

104G

SC15F Application

R134a

Blue stripe Approvals

8510

Barcode on white background

Application LBP*)

Application Evaporating temperature range Voltage range

°C

198 - 254 /50

Motor type

RSIR/CSIR °C

Comp. cooling at ambient temp.

DANFOSS COMPRESSORS

Yellow background

-35 to -10

V/Hz

Max. ambient temperature

8275-2

Compressor

S O F1

38

32°C

O/F1

38°C

O/F1

F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

*) Can be used as a HBP compressor with 240V 50Hz mains (216-254V).

Design Displacement

cm 3

Oil quantity

cm 3 550 (500 on comp. with oil cooler)

Maximum refrigerant charge Free gas vol. in compressor

g

1300

3

1410

cm

Weight without electrical equipment

15.28

kg

204 178 170

ø16

12.6

ø19 ø9.7

watt

LRA (rated after 4 sec. UL984) LST/HST

315

A

12.6/12.6

Cut-in current LST/HST

A

17.2/12.6

Resistance, main and start winding (25°C)



70 150

Motor size

127 101.6 35

Motor

6.7/11.8

Approvals

EN 60335-2-34, CCIB

127 165 186 218

D

C

Dimensions

E 203

B1

183

B2

100

Suction connector

location/I.D. mm

C

8.2 ±0.09

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

6.2 ±0.09

Oil cooler

location/I.D. mm

F

6.2 ±0.09

pcs.

80

30

62

CD.44.H5.02

CK.40.B7.02

B2

F

37°

37°

107

August 2003

15

255

55

Compressors on a pallet

B A

B1

53

B

63

209

107 115

55 63

A

3

mm

151

Height

8264

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C SC15F

-35 100

-30 155

-25 230

watt -23.3 260

-20 325

-15 439

-10 573

HST c

Capacity (ASHRAE) Comp.\°C SC15F

-35 123

-30 191

watt -25 283

-23.3 320

-20 400

-15 541

-10 707 b 8222

Power consumption Comp.\°C SC15F

-35 186

-30 229

watt -25 275

-23.3 291

-20 324

-15 377

-10 432

a2 d

Current consumption Comp.\°C SC15F

-35 1.67

-30 1.78

A -25 1.93

-23.3 1.99

-20 2.11

-15 2.28

-10 2.44

c 11

10

COP (EN 12900/CECOMAF) Comp.\°C SC15F

-35 0.54

W/W

-30 0.68

-25 0.84

-23.3 0.89

-20 1.00

-15 1.17

-10 1.33

-30 0.83

-25 1.03

-23.3 1.10

-20 1.23

-15 1.44

-10 1.64

COP (ASHRAE) Comp.\°C SC15F

-35 0.66

12

13 14

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Fan cooling, 220V 50Hz

EN 12900/CECOMAF 55°C 32°C 55°C

Start winding Main winding Winding protector

ASHRAE 55°C 32°C 32°C

LST

b 8221

a1 d

Accessories

Main winding

Devices

Fig.

a1

Start winding

SC15F N

PTC starting device

a1

103N0002

Starting relay

6.3 mm spades

a2

117U6003

Cover

b

103N2009

Starting capacitor 80 µF

c

117U5017

Cord relief

d

103N1004

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

N

118-1917 118-1918 118-1919

C

L

Winding protector

CD.44.H5.02

CK.40.B7.02

August 2003

63

SC18F Standard Compressor R134a 220-240V 50Hz Data Sheet (Replaces CD.44.B6.02) General SC18F

Code number

104G8800

Code number compressor with oil cooler

104G8810

104G

SC18F Application

R134a

Blue stripe Approvals

8810

Barcode on white background

Application LBP*)

Application Evaporating temperature range Voltage range

°C

198 - 254 /50

Motor type

CSIR °C

Comp. cooling at ambient temp.

DANFOSS COMPRESSORS

Yellow background

-35 to -5

V/Hz

Max. ambient temperature

8275-3

Compressor

S O F1

38

32°C

O/F1

38°C

O/F1

F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

*) Can be used as a HBP compressor with 240V 50Hz mains (216-254V).

Design Displacement

cm 3

Oil quantity

cm 3 550 (500 on comp. with oil cooler)

Maximum refrigerant charge Free gas vol. in compressor

g

1300

3

1410

cm

Weight without electrical equipment

17.69

kg

204 178 170

ø16

13.1

ø19 ø9.7

LRA (rated after 4 sec. UL984) HST

watt

385

A

14.8

Cut-in current HST

A

14.8

Resistance, main and start winding (25°C)



5.0/13.7

Approvals

EN 60335-2-34

70 150

Motor size

127 101.6 35

Motor

127 165 186 218

D

C

Dimensions

E 203

B1

183

B2

100

Suction connector

location/I.D. mm

C

10.2 ±0.09

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

6.2 ±0.09

Oil cooler

location/I.D. mm

F

6.2 ±0.09

pcs.

80

30

64

CD.44.B7.02

CK.40.B7.02

B2

F

37°

37°

107

August 2003

15

255

55

Compressors on a pallet

B A

B1

53

B

63

209

107 115

55 63

A

3

mm

151

Height

8264

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C SC18F

-35 129

-30 194

-25 280

watt -23.3 314

-20 388

-15 518

-10 669

-5 842 c

Capacity (ASHRAE) Comp.\°C SC18F

-35 159

-30 238

watt -25 345

-23.3 387

-20 478

-15 638

-10 825

-5 1039 b 8222

Power consumption Comp.\°C SC18F

-35 206

-30 258

watt -25 313

-23.3 332

-20 370

-15 430

-10 492

-5 556

a2 d

Current consumption Comp.\°C SC18F

-35 2.04

-30 2.15

A -25 2.29

-23.3 2.35

-20 2.46

-15 2.65

-10 2.84

-5 3.05

c 11

10

COP (EN 12900/CECOMAF) Comp.\°C SC18F

-35 0.63

W/W

-30 0.75

-25 0.90

-23.3 0.95

-20 1.05

-15 1.20

-10 1.36

-30 0.92

-25 1.10

-23.3 1.17

-20 1.29

-15 1.48

-10 1.68

COP (ASHRAE) Comp.\°C SC18F

-35 0.77

-5 1.51

12

13 14

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Fan cooling, 220V 50Hz

EN 12900/CECOMAF 55°C 32°C 55°C

-5 1.87

Start winding Main winding Winding protector

ASHRAE 55°C 32°C 32°C

Accessories Devices

Fig.

SC18F

Starting relay

a2

117U6005

Cover

b

103N2009

Starting capacitor 80 µF

c

117U5017

Cord relief

d

103N1004

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

118-1917 118-1918 118-1919

CD.44.B7.02

CK.40.B7.02

August 2003

65

SC21F Standard Compressor R134a 220-240V 50Hz Data Sheet (Replaces CD.44.X2.02) General SC21F

Code number

104G8100

Code number compressor with oil cooler

104G8110

104G

SC21F Application

R134a

Blue stripe Approvals

8110

Barcode on white background

Application LBP*)

Application Evaporating temperature range Voltage range

°C

198 - 254 /50

Motor type

CSIR °C

Comp. cooling at ambient temp.

DANFOSS COMPRESSORS

Yellow background

-35 to -5

V/Hz

Max. ambient temperature

8275

Compressor

S O F1

38

32°C

O/F1

38°C

O/F1

F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

*) Can be used as a HBP compressor with 240V 50Hz mains (216-254V).

Design Displacement

cm3

Oil quantity

cm3 550 (500 on comp. with oil cooler)

Maximum refrigerant charge Free gas vol. in compressor

20.95

g

1300

3

1460

cm

Weight without electrical equipment

kg

204 178 170

ø16

13.3

ø19 ø9.7

LRA (rated after 4 sec. UL984) HST

watt

495

A

18.6

Cut-in current HST

A

18.6

Resistance, main and start winding (25°C)



3.7/14.1

Approvals

EN 60335-2-34

70 150

Motor size

127 101.6 35

Motor

127 165 186 218

D

C

Dimensions

E 213

B1

193

B2

110

Suction connector

location/I.D. mm

C

10.2 ±0.09

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

6.2 ±0.09

Oil cooler

location/I.D. mm

F

6.2 ±0.09

pcs.

80

30

66

CD.44.X3.02

CK.40.B7.02

B2

F

37°

37°

107

August 2003

15

255

55

Compressors on a pallet

B A

B1

53

B

63

219

107 115

55 63

A

3

mm

151

Height

8264

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C SC21F

-35 185

-30 245

-25 335

watt -23.3 375

-20 455

-15 610

-10 780

-5 990 c

Capacity (ASHRAE) Comp.\°C SC21F

-35 228

-30 302

watt -25 412

-23.3 462

-20 560

-15 750

-10 960

-5 1220 b 8222

Power consumption Comp.\°C SC21F

-35 275

-30 325

watt -25 380

-23.3 405

-20 450

-15 520

-10 600

-5 685

a2 d

Current consumption Comp.\°C SC21F

-35 2.50

-30 2.64

A -25 2.77

-23.3 2.81

-20 2.92

-15 3.16

-10 3.53

-5 4.09

c 11

10

COP (EN 12900/CECOMAF) Comp.\°C SC21F

-35 0.67

W/W

-30 0.75

-25 0.88

-23.3 0.92

-20 1.01

-15 1.17

-10 1.30

-30 0.93

-25 1.08

-23.3 1.14

-20 1.24

-15 1.44

-10 1.60

COP (ASHRAE) Comp.\°C SC21F

-35 0.83

-5 1.45

12

13 14

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Fan cooling, 220V 50Hz

EN 12900/CECOMAF 55°C 32°C 55°C

-5 1.78

Start winding Main winding Winding protector

ASHRAE 55°C 32°C 32°C

Accessories Devices

Fig.

SC21F

Starting relay

a2

117U6019

Cover

b

103N2009

Starting capacitor 80 µF

c

117U5017

Cord relief

d

103N1004

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

118-1917 118-1918 118-1919

CD.44.X3.02

CK.40.B7.02

August 2003

67

SC12G Standard Compressor R134a 220-240V 60Hz Data Sheet General SC12G

Code number

104G8245

104G

SC12G Application

R134a

Blue stripe Approvals

Application Application Evaporating temperature range Voltage range

°C V/Hz

MBP

Barcode on white background

-20 to 10

Yellow background

8245

DANFOSS COMPRESSORS

8286-10

Compressor

198 - 254 /60

Motor type

CSIR

Max. ambient temperature

°C

43

32°C

F2

38°C

F2

43°C

F2

Displacement

cm3

12.87

Oil quantity

cm3

Comp. cooling at ambient temp.

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

Design

Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment

550

g

1300

cm3

1510

kg

12.6

204 178 170

ø16

ø19 ø9.7

watt

470

LRA (rated after 4 sec. UL984) HST

A

19.7

Cut-in current HST

A

70 150

Motor size

127 101.6 35

Motor

19.7

Resistance, main and start winding (25°C) Ω

127 165 186 218

4.3/15.3

Approvals

-

D

C E

Dimensions 209 203

B1

193

B2

110

Suction connector

location/I.D. mm

C

10.2 ±0.09

Process connector

location/I.D. mm

D

6.5 ±0.09

Discharge connector

location/I.D. mm

E

6.5 ±0.09

pcs.

80

B2

255

55

Compressors on a pallet

B A

B1

63

B

37°

37°

107

August 2003

68

CG.44.L1.02

CK.40.B7.02

107 115

55 63

A

3

mm

151

Height

8258

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C SC12G

-20 298

-15 418

-10 561

watt -5 725

0 910

5 1114

7.2 1208

10 1334 c

Capacity (ASHRAE) Comp.\°C SC12G

-20 366

-15 513

watt -10 690

-5 893

0 1112

5 1378

7.2 1497

10 1654 b 8222

Power consumption Comp.\°C SC12G

-20

-15

watt -10 415

-5

0

5 572

7.2

10

a2 d

Current consumption Comp.\°C SC12G

-20

-15

A -10 2.70

-5

0

5 3.35

7.2

10 c 11

10

COP (EN 12900/CECOMAF) Comp.\°C SC12G

-20

-15

W/W

-10 1.35

-5

-10 1.67

-5

0

5 1.95

7.2

-20

5 2.41

7.2

12

13 14

COP (ASHRAE) Comp.\°C SC12G

10

W/W -15

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Fan cooling F2, 220V 60Hz preliminary data

0

EN 12900/CECOMAF 55°C 32°C 55°C

10

Start winding Main winding Winding protector

ASHRAE 55°C 32°C 32°C

Accessories Devices

Fig.

SC12G

Star ting Relay

a2

117U6011

Cover

b

103N2009

Star ting capacitor 80 µF

c

117U5017

Cord relief

d

103N1004

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

118-1917 118-1918 118-1919

CG.44.L1.02

CK.40.B7.02

August 2003

69

SC15G Standard Compressor R134a 220-240V 60Hz Data Sheet General SC15G

Code number

104G8526

104G

SC15G Application

R134a

Blue stripe Approvals

Application Application Evaporating temperature range Voltage range

°C V/Hz

MBP

Barcode on white background

-20 to 10

Yellow background

8526

DANFOSS COMPRESSORS

8286-11

Compressor

198 - 254 /60

Motor type

CSIR

Max. ambient temperature

°C

43

32°C

F2

38°C

F2

43°C

F2

Displacement

cm3

15.28

Oil quantity

cm3

Comp. cooling at ambient temp.

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

Design

Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment

550

g

1300

cm3

1410

kg

13.1

204 178 170

ø16

ø19 ø9.7

watt

470

LRA (rated after 4 sec. UL984) HST

A

19.7

Cut-in current HST

A

70 150

Motor size

127 101.6 35

Motor

19.7

Resistance, main and start winding (25°C) Ω

127 165 186 218

4.3/15.3

Approvals

-

D

C E

Dimensions 219 213

B1

193

B2

110

Suction connector

location/I.D. mm

C

10.2 ±0.09

Process connector

location/I.D. mm

D

6.5 ±0.09

Discharge connector

location/I.D. mm

E

6.5 ±0.09

pcs.

80

B2

255

55

Compressors on a pallet

B A

B1

63

B

37°

37°

107

August 2003

70

CG.44.M1.02

CK.40.B7.02

107 115

55 63

A

3

mm

151

Height

8258

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C SC15G

-20 374

-15 510

-10 672

watt -5 855

0 1061

5 1291

7.2 1398

10 1543 c

Capacity (ASHRAE) Comp.\°C SC15G

-20 460

-15 626

watt -10 827

-5 1053

0 1296

5 1596

7.2 1733

10 1912 b 8222

Power consumption Comp.\°C SC15G

-20

-15

watt -10 496

-5

0

5 690

7.2

10

a2 d

Current consumption Comp.\°C SC15G

-20

-15

A -10 3.05

-5

0

5 3.70

7.2

10 c 11

10

COP (EN 12900/CECOMAF) Comp.\°C SC15G

-20

-15

W/W

-10 1.35

-5

-10 1.67

-5

0

5 1.87

7.2

-20

5 2.31

7.2

12

13 14

COP (ASHRAE) Comp.\°C SC15G

10

W/W -15

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Fan cooling F2, 220V 60Hz preliminary data

0

EN 12900/CECOMAF 55°C 32°C 55°C

10

Start winding Main winding Winding protector

ASHRAE 55°C 32°C 32°C

Accessories Devices

Fig.

SC15G

Star ting Relay

a2

117U6011

Cover

b

103N2009

Star ting capacitor 80 µF

c

117U5017

Cord relief

d

103N1004

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

118-1917 118-1918 118-1919

CG.44.M1.02

CK.40.B7.02

August 2003

71

SC18G Standard Compressor R134a 220-240V 60Hz Data Sheet General SC18G

Code number

104G8823

104G

SC18G Application

R134a

Blue stripe Approvals

Application Application Evaporating temperature range Voltage range

°C V/Hz

MBP

Barcode on white background

-20 to 10

Yellow background

8823

DANFOSS COMPRESSORS

8286-12

Compressor

198 - 254 /60

Motor type

CSR

Max. ambient temperature

°C

43

32°C

F2

38°C

F2

43°C

F2

Displacement

cm3

17.69

Oil quantity

cm3

Comp. cooling at ambient temp.

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

Design

Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment

550

g

1300

cm3

1460

kg

13.7

204 178 170

ø16

ø19 ø9.7

watt

550

LRA (rated after 4 sec. UL984) HST

A

21.8

Cut-in current HST

A

70 150

Motor size

127 101.6 35

Motor

21.8

Resistance, main and start winding (25°C) Ω

127 165 186 218

3.5/12.1

Approvals

-

D

C E

Dimensions 219 213

B1

193

B2

110

Suction connector

location/I.D. mm

C

10.2 ±0.09

Process connector

location/I.D. mm

D

6.5 ±0.09

Discharge connector

location/I.D. mm

E

6.5 ±0.09

pcs.

80

B2

255

55

Compressors on a pallet

B A

B1

63

B

37°

37°

107

August 2003

72

CG.44.N1.02

CK.40.B7.02

107 115

55 63

A

3

mm

151

Height

8258

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C SC18G

-20 432

-15 573

-10 745

watt -5 955

0 1207

5 1506

7.2 1654

Capacity (ASHRAE) Comp.\°C SC18G

-20 534

-15 707

-20 393

-15 449

-10 921

-5 1181

0 1495

5 1869

7.2 2054

-20 1.83

-15 2.14

-20 1.10

-15 1.27

-10 511

-5 577

0 643

5 708

7.2 736

10 770

-10 2.45

-5 2.75

0 3.05

5 3.35

7.2 3.48

10 3.65

W/W -5 1.66

0 1.88

5 2.13

7.2 2.25

COP (ASHRAE) Comp.\°C SC18G

-20 1.36

8227

d

A

-10 1.46

10 2.41

b e

Start winding 5

2

4

1

a2

Main winding Winding protector 1

1

2 N L

2 N L

Bleeder resistance

c

a3

W/W -15 1.57

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Fan cooling F2, 220V 60Hz

-10 1.80

-5 2.05

0 2.33

EN 12900/CECOMAF 55°C 32°C 55°C

5 2.64

7.2 2.79

e

c

watt

COP (EN 12900/CECOMAF) Comp.\°C SC18G

a2

10 2310

Current consumption Comp.\°C SC18G

a3

watt

Power consumption Comp.\°C SC18G

10 1858

10 3.00

M

Thermostat

Fan

ASHRAE 55°C 32°C 32°C

Accessories Devices

Fig.

SC18G

a3

117-7028 (470 mm cable length) 117-7029 (550 mm cable length) 117-7032 (650 mm cable length) 103N2009

Star ting device

Cover

b

Star ting relay

a2

Star ting capacitor

c

Run capacitor

e

Cord relief

d

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

Components of star ting device 103N1004 118-1917 118-1918 118-1919

CG.44.N1.02

CK.40.B7.02

August 2003

73

PLE35F Energy-optimized Compressor R134a 220-240V 50Hz Data Sheet (Replaces CD.41.D8.02) General PLE35F

Code number

101G0201

PLE35F R134a

Blue stripe

Application

101G

Application

0201

Approvals

Application Evaporating temperature range Voltage range

°C V/Hz

MBP

Barcode on white background

-25 to 0

Yellow background

DANFOSS COMPRESSORS

8276

Compressor

198 - 254 /50

Motor type

RSCR*

Max. ambient temperature Comp. cooling at ambient temp.

°C

38

32°C

S

38°C

S * run capacitor 4 µF compulsory

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

Design Displacement

cm3

2.00

Oil quantity

cm3

135

Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment

g

300

cm3

870

kg

4.8

Motor Motor size

watt

37

LRA (rated after 4 sec. UL984) LST

A

1.3

Cut-in current LST

A

5.0

Resistance, main and start winding (25°C)



204 170

57.0/22.0 100

EN 60335-2-34 with Annex AA 35 70

Approvals

Dimensions Height

Suction connector

mm

location/I.D. mm

A

137

B

135

B1

128

B2

73

C

6.2 ±0.09

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

5.0 +0.12/+0.20

pcs.

C

D

ø9

E

B1 B A B2 206

150

8241

46 59 130

50 60.5

Compressors on a pallet

ø16

127

February 2003

74

CD.41.D9.02

CK.40.B7.02

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C PLE35F

-25 32

-23.3 36

-20 45

watt -15 60

-10 79

-5 100

0 125

Capacity (ASHRAE) Comp.\°C PLE35F

-25 39

g

watt

-23.3 44

-20 55

-15 74

-10 97

-5 124

e

0 154 b 8216

Power consumption Comp.\°C PLE35F

-25 44

watt

-23.3 46

-20 50

-15 56

-10 62

-5 69

a1

0 78 d

Current consumption Comp.\°C PLE35F

-25 0.20

-23.3 0.21

-20 0.23

-15 0.26

-10 0.29

-5 0.32

0 0.34

COP (EN 12900/CECOMAF) Comp.\°C PLE35F

-25 0.73

-25 0.89

Main winding

a1

S

N

Start winding

W/W

-23.3 0.78

-20 0.89

-15 1.07

-10 1.27

-5 1.45

-23.3 0.96

-20 1.09

-15 1.32

-10 1.57

-5 1.79

COP (ASHRAE) Comp.\°C PLE35F

e

A

0 1.60

N

C

L

W/W

Test conditions EN 12900/CECOMAF Condensing temperature 55°C Ambient and suction gas temp. 32°C Liquid temperature 55°C Static cooling, with RC 4 µF, 220V 50Hz, PTC consumption incl.

0 1.98

Winding protector

ASHRAE 55°C 32°C 32°C

Accessories Devices PTC starting device

6.3 mm spades 4.8 mm spades

Fig.

PLE35F

a1

103N0016 103N0021

Cover

b

103N0491

Cord relief

d

103N1010

Run capacitor 4 µF (compulsory) 6.3 mm spades 4.8 mm spades

e

117-7117 117-7119

Protection screen for PTC

g

103N0476

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

118-1917 118-1918 118-1919

CD.41.D9.02

CK.40.B7.02

February 2003

75

PLE50F Energy-optimized Compressor R134a 220-240V 50Hz Data Sheet (Replaces CD.41.H3.02) General PLE50F

Code number

101G0221

PLE50F R134a

Blue stripe

Application

101G

Application

0221

Approvals

Application Evaporating temperature range Voltage range

°C V/Hz

MBP

Barcode on white background

-25 to 0

Yellow background

DANFOSS COMPRESSORS

8276-2

Compressor

198 - 254 /50

Motor type

RSCR*

Max. ambient temperature Comp. cooling at ambient temp.

°C

38

32°C

S

38°C

S * run capacitor 4 µF compulsory

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

Design Displacement

cm3

Oil quantity

cm3

150

g

300

cm3

870

kg

4.8

Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment

2.50

Motor Motor size

watt

44

LRA (rated after 4 sec. UL984) LST

A

1.4

Cut-in current LST

A

5.1

Resistance, main and start winding (25°C)



47.0/24.0 100

EN 60335-2-34 with Annex AA 35 70

Approvals

204 170

Dimensions Height

Suction connector

mm

location/I.D. mm

A

140

B

138

B1

131

B2

73

C

6.2 ±0.09

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

5.0 +0.12/+0.20

pcs.

C

D

ø9

E

B1 B A B2 206

150

8241

46 59 130

50 60.5

Compressors on a pallet

ø16

127

February 2003

76

CD.41.H4.02

CK.40.B7.02

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C PLE50F

-25 42.0

-23.3 47.2

-20 57.9

watt -15 76.2

-10 97.4

-5 122

0 150

Capacity (ASHRAE) Comp.\°C PLE50F

-25 51.9

g

watt

-23.3 58.2

-20 71.5

-15 94.1

-10 120

-5 151

e

0 186 b 8216

Power consumption Comp.\°C PLE50F

-25 52.0

watt

-23.3 54.4

-20 59.0

-15 66.3

-10 74.2

-5 82.8

a1

0 92.6 d

Current consumption Comp.\°C PLE50F

-25 0.29

-23.3 0.30

-20 0.31

-15 0.34

-10 0.37

-5 0.40

COP (EN 12900/CECOMAF) Comp.\°C PLE50F

-25 0.81

-25 1.00

0 0.44

Main winding

a1

S

N

Start winding

W/W

-23.3 0.87

-20 0.98

-15 1.15

-10 1.31

-5 1.47

-23.3 1.07

-20 1.21

-15 1.42

-10 1.62

-5 1.82

COP (ASHRAE) Comp.\°C PLE50F

e

A

0 1.62

N

C

L

W/W

Test conditions EN 12900/CECOMAF Condensing temperature 55°C Ambient and suction gas temp. 32°C Liquid temperature 55°C Static cooling, with RC 4 µF, 220V 50Hz, PTC consumption incl.

0 2.01

Winding protector

ASHRAE 55°C 32°C 32°C

Accessories Devices PTC starting device

6.3 mm spades 4.8 mm spades

Fig.

PLE50F

a1

103N0016 103N0021

Cover

b

103N0491

Cord relief

d

103N1010

Run capacitor 4 µF (compulsory) 6.3 mm spades 4.8 mm spades

e

117-7117 117-7119

Protection screen for PTC

g

103N0476

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

118-1917 118-1918 118-1919

CD.41.H4.02

CK.40.B7.02

February 2003

77

TLES3F Energy-optimized Compressor R134a 220-240V 50Hz Data Sheet (Replaces CD.42.H6.02) General TLES3F

Code number

102G4310

Application

R134a SUCTION CONNECTOR

Blue stripe

Application

102G

TLES3F

4310

Approvals

Application

MBP

Evaporating temperature range Voltage range

°C

-25 to 0

V/Hz

Barcode on white background

8277

Compressor

DANFOSS COMPRESSORS

Yellow background

198 - 254 /50

Motor type

RSIR/RSCR

Max. ambient temperature Comp. cooling at ambient temp.

°C

43

32°C

S

38°C

S

43°C

S

Displacement

cm3

3.13

Oil quantity

cm 3

180

g

400

3

1790

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

Design

Maximum refrigerant charge Free gas vol. in compressor

cm

Weight without electrical equipment

kg

7.5 ø16

Motor size

watt

74

LRA (rated after 4 sec. UL984) LST

A

2.6

Cut-in current LST

A

6.9

Resistance, main and start winding (25°C) Ω Approvals

170 178 186 204

EN 60335-2-34 with Annex AA

C

C

6.2 ±0.09

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

5.0 +0.12/+0.20

pcs.

A B

105 107

location/I.D. mm

Process connector

E 30°

173 169

° 31.5 28°

A B

D

222 176

105

mm

Suction connector

Compressors on a pallet

ø9

27.5/15.1

Dimensions Height

35 70 100

Motor

125

102

August 2001

78

CD.42.H7.02

CK.40.B7.02

71

29

51 20° °

45°

157 60.5 66

8244

96 117

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C TLES3F

-25 50.0

-23.3 56.2

-20 69.6

watt -15 93.1

-10 121

-5 155

0 193 g

Capacity (ASHRAE) Comp.\°C TLES3F

-25 61.7

-23.3 69.4

watt -20 85.9

-15 115

-10 150

-5 191

-20 71.1

-15 81.1

-10 92.4

-5 105

0 120

-20 0.48

-15 0.52

-10 0.56

-5 0.60

0 0.65

Power consumption Comp.\°C TLES3F

-25 62.0

-23.3 65.0

0 240

-25 0.45

-23.3 0.46

-25 0.81

-25 1.00

d Main winding a1 Start winding N

W/W

-23.3 0.87

-20 0.98

-15 1.15

-10 1.31

-5 1.47

-23.3 1.07

-20 1.21

-15 1.42

-10 1.62

-5 1.82

COP (ASHRAE) Comp.\°C TLES3F

a1

A

COP (EN 12900/CECOMAF) Comp.\°C TLES3F

8217

watt

Current consumption Comp.\°C TLES3F

b

0 1.61

N

L

C

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Static cooling, 220V 50Hz, PTC consumption incl.

EN 12900/CECOMAF 55°C 32°C 55°C

0 2.00

Winding protector

(pos.1)

ASHRAE 55°C 32°C 32°C

g

e

b

Accessories

8223

Devices

Fig.

TLES3F

PTC star ting device

6.3 mm spades a1 4.8 mm spades (pos.1)

103N0011 103N0018

PTC star ting device

6.3 mm spades a1 4.8 mm spades (pos.2)

103N0016 103N0021

Cover

b

103N2010

Cord relief

d

103N1010

Run capacitor 4 µF (optional) 6.3 mm spades 4.8 mm spades

e

117-7117 117-7119

Protection screen for PTC

g

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

a1 d e Main winding

N

N

a1 Start winding

S

C

L

103N0476 118-1917 118-1918 118-1919

Winding protector

(pos.2)

CD.42.H7.02

CK.40.B7.02

August 2001

79

TLES4F Energy-optimized Compressor R134a 220-240V 50Hz Data Sheet (Replaces CG.42.D2.02) General TLES4F

Code number

102G4410

Application

R134a SUCTION CONNECTOR

Blue stripe

Application

102G

TLES4F

4410

Approvals

Application

LBP

Evaporating temperature range Voltage range

°C

-35 to -10

V/Hz

Barcode on white background

8277-3

Compressor

DANFOSS COMPRESSORS

Yellow background

198 - 254 /50

Motor type

RSIR/RSCR

Max. ambient temperature

°C

43

32°C

S

38°C

S

43°C

S

Displacement

cm 3

3.86

Oil quantity

cm 3

180

g

400

cm3

1790

kg

7.5

Comp. cooling at ambient temp.

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

Design

Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment

ø16

Motor size LRA (rated after 4 sec. UL984) LST

watt

80

A

2.9

Cut-in current LST

A

7.6

Resistance, main and start winding (25°C)



25.7/15.7

Approvals

170 178 186 204

C

location/I.D. mm

C

6.2 ±0.09

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

5.0 +0.12/+0.20

pcs.

E

A B

105 107

169

30°

173

B

° 31.5 28°

A

D

222 176

105

mm

Suction connector

Compressors on a pallet

ø9

EN 60335-2-34 with Annex AA

Dimensions Height

35 70 100

Motor

125

102

August 2001

80

CG.42.D3.02

CK.40.B7.02

71

29

51 20° °

45°

157 60.5 66

8244

96 117

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C TLES4F

-35 32.6

-30 49.5

-25 70.0

watt -23.3 77.9

-20 94.8

-15 124

-10 160 g

Capacity (ASHRAE) Comp.\°C TLES4F

-35 40.1

-30 61.1

watt -25 86.4

-23.3 96.2

-20 117

-15 154

-10 197

-25 80.0

-23.3 83.8

-20 91.4

-15 104

-10 118

-25 0.54

-23.3 0.56

-20 0.60

-15 0.66

-10 0.73

Power consumption Comp.\°C TLES4F

-35 59.9

-30 69.5

-35 0.45

-30 0.49

-35 0.54

-35 0.67

d Main winding a1 Start winding N

W/W

-30 0.71

-25 0.88

-23.3 0.93

-20 1.04

-15 1.20

-30 0.88

-25 1.08

-23.3 1.15

-20 1.28

-15 1.48

COP (ASHRAE) Comp.\°C TLES4F

a1

A

COP (EN 12900/CECOMAF) Comp.\°C TLES4F

8217

watt

Current consumption Comp.\°C TLES4F

b

-10 1.35

N

L

C

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Static cooling, 220V 50Hz, PTC consumption incl.

EN 12900/CECOMAF 55°C 32°C 55°C

-10 1.67

Winding protector

(pos.1)

ASHRAE 55°C 32°C 32°C

g

e

b

Accessories

8223

Devices

Fig.

TLES4F

PTC star ting device

6.3 mm spades a1 4.8 mm spades (pos.1)

103N0011 103N0018

PTC star ting device

6.3 mm spades a1 4.8 mm spades (pos.2)

103N0016 103N0021

Cover

b

103N2010

Cord relief

d

103N1010

Run capacitor 4 µF (optional) 6.3 mm spades 4.8 mm spades

e

117-7117 117-7119

Protection screen for PTC

g

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

a1 d e Main winding

N

N

a1 Start winding

S

C

L

103N0476 118-1917 118-1918 118-1919

Winding protector

(pos.2)

CG.42.D3.02

CK.40.B7.02

August 2001

81

TLES5F Energy-optimized Compressor R134a 220-240V 50Hz Data Sheet (Replaces CG.42.E2.02) General TLES5F

Code number

102G4510

Application

R134a SUCTION CONNECTOR

Blue stripe

Application

102G

TLES5F

4510

Approvals

Application

LBP

Evaporating temperature range Voltage range

°C

-35 to -10

V/Hz

Barcode on white background

8277-4

Compressor

DANFOSS COMPRESSORS

Yellow background

198 - 254 /50

Motor type

RSIR/RSCR

Max. ambient temperature

°C

Comp. cooling at ambient temp.

43*

32°C

S

38°C

S

43°C

S

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

* run capacitor 4 µF recommended in 43°C ambient temperature

Design Displacement

cm 3

5.08

Oil quantity

cm 3

180

Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment

g

400

cm3

1790

kg

7.6 ø16

Motor size

watt

105

LRA (rated after 4 sec. UL984) LST

A

4.0

Cut-in current LST

A

8.5

Resistance, main and start winding (25°C)



18.9/15.3

Approvals

170 178 186 204

C

location/I.D. mm

C

6.2 ±0.09

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

5.0 +0.12/+0.20

pcs.

E

A B

105 107

169

30°

173

B

° 31.5 28°

A

D

222 176

105

mm

Suction connector

Compressors on a pallet

ø9

EN 60335-2-34 with Annex AA

Dimensions Height

35 70 100

Motor

125

102

August 2001

82

CG.42.E3.02

CK.40.B7.02

71

29

51 20° °

45°

157 60.5 66

8244

96 117

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C TLES5F

-35 49.9

-30 71.5

-25 98.0

watt -23.3 108

-20 130

-15 169

-10 216 g

Capacity (ASHRAE) Comp.\°C TLES5F

-35 61.5

-30 88.1

watt -25 121

-23.3 134

-20 161

-15 209

-10 267

-25 105

-23.3 110

-20 121

-15 139

-10 158

-25 0.71

-23.3 0.73

-20 0.78

-15 0.85

-10 0.92

Power consumption Comp.\°C TLES5F

-35 77.3

-30 90.5

-35 0.59

-30 0.65

-35 0.65

-35 0.80

d Main winding a1 Start winding N

W/W

-30 0.79

-25 0.93

-23.3 0.98

-20 1.08

-15 1.22

-10 1.37

-30 0.97

-25 1.15

-23.3 1.21

-20 1.33

-15 1.51

-10 1.69

COP (ASHRAE) Comp.\°C TLES5F

a1

A

COP (EN 12900/CECOMAF) Comp.\°C TLES5F

8217

watt

Current consumption Comp.\°C TLES5F

b

N

L

C

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Static cooling, 220V 50Hz, PTC consumption incl.

EN 12900/CECOMAF 55°C 32°C 55°C

Winding protector

(pos.1)

ASHRAE 55°C 32°C 32°C

g

e

b

Accessories

8223

Devices

Fig.

TLES5F

PTC star ting device

6.3 mm spades a1 4.8 mm spades (pos.1)

103N0011 103N0018

PTC star ting device

6.3 mm spades a1 4.8 mm spades (pos.2)

103N0016 103N0021

Cover

b

103N2010

Cord relief

d

103N1010

Run capacitor 4 µF (optional) 6.3 mm spades 4.8 mm spades

e

117-7117 117-7119

Protection screen for PTC

g

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

a1 d e Main winding

N

N

a1 Start winding

S

C

L

103N0476 118-1917 118-1918 118-1919

Winding protector

(pos.2)

* run capacitor 4 µF recommended in 43°C ambient temperature

2

August 2003

CG.42.E3.02

CK.40.B7.02

August 2001

83

TLES6F Energy-optimized Compressor R134a 220-240V 50Hz Data Sheet (Replaces CD.42.T4.02) General TLES6F

Code number

102G4610

Application

R134a SUCTION CONNECTOR

Blue stripe

Application

102G

TLES6F

4610

Approvals

Application

LBP

Evaporating temperature range Voltage range

°C

-35 to -10

V/Hz

Barcode on white background

8277-5

Compressor

DANFOSS COMPRESSORS

Yellow background

198 - 254 /50

Motor type

RSIR/RSCR

Max. ambient temperature

°C

Comp. cooling at ambient temp.

43*

32°C

S O F1

S

38°C

S

43°C

S

F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

* run capacitor 4 µF compulsory in 38°C and higher ambient temperature

Design Displacement

cm3

5.70

Oil quantity

cm 3

180

g

400

3

1790

Maximum refrigerant charge Free gas vol. in compressor

cm

Weight without electrical equipment

kg

7.6 ø16

Motor size

watt

120

LRA (rated after 4 sec. UL984) LST

A

4.5

Cut-in current LST

A

8.8

Resistance, main and start winding (25°C)



16.5/16.9

Approvals

170 178 186 204

C

C

6.2 ±0.09

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

5.0 +0.12/+0.20

pcs.

A B

105 107

location/I.D. mm

Process connector

E 30°

173 169

° 31.5 28°

A B

D

222 176

105

mm

Suction connector

Compressors on a pallet

ø9

EN 60335-2-34 with Annex AA

Dimensions Height

35 70 100

Motor

125

102

August 2001

84

CD.42.T5.02

CK.40.B7.02

71

29

51 20° °

45°

157 60.5 66

8244

96 117

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C TLES6F

-35 58

-30 77

-25 104

watt -23.3 115

-20 139

-15 183

-10 235 g

Capacity (ASHRAE) Comp.\°C TLES6F

-35 71

-30 95

watt -25 128

-23.3 142

-20 172

-15 226

-10 290

-25 112

-23.3 118

-20 131

-15 151

-10 172

-25 0.75

-23.3 0.77

-20 0.82

-15 0.89

-10 0.97

Power consumption Comp.\°C TLES6F

-35 76

-30 93

-35 0.63

-30 0.69

-35 0.76

-35 0.94

d Main winding a1 Start winding N

W/W

-30 0.82

-25 0.93

-23.3 0.97

-20 1.06

-15 1.21

-10 1.37

-30 1.01

-25 1.14

-23.3 1.20

-20 1.31

-15 1.49

-10 1.69

COP (ASHRAE) Comp.\°C TLES6F

a1

A

COP (EN 12900/CECOMAF) Comp.\°C TLES6F

8217

watt

Current consumption Comp.\°C TLES6F

b

N

L

C

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Static cooling, 220V 50Hz, PTC consumption incl.

EN 12900/CECOMAF 55°C 32°C 55°C

Winding protector

(pos.1)

ASHRAE 55°C 32°C 32°C

g

Accessories

e

b 8223

Devices

Fig.

TLES6F

PTC star ting device

6.3 mm spades a1 4.8 mm spades (pos.1)

103N0011 103N0018

PTC star ting device

6.3 mm spades a1 4.8 mm spades (pos.2)

103N0016* 103N0021*

Cover

b

103N2010

Cord relief

d

103N1010

e

117-7117* 117-7119*

a1 d e Main winding

N

a1 Start winding

S

Run capacitor 4 µF 6.3 mm spades 4.8 mm spades Protection screen for PTC Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

g

N

C

L

103N0476 118-1917 118-1918 118-1919

Winding protector

(pos.2)

* run capacitor 4 µF compulsory in 38°C and higher ambient temp.

2

August 2003

CD.42.T5.02

CK.40.B7.02

August 2001

85

TLES7F Energy-optimized Compressor R134a 220-240V 50Hz Data Sheet (Replaces CG.42.F1.02) General TLES7F

Code number

102G4710

Application

R134a SUCTION CONNECTOR

Blue stripe

Application

102G

TLES7F

4710

Approvals

Application

LBP

Evaporating temperature range Voltage range

°C

-35 to -10

V/Hz

Barcode on white background

8277-6

Compressor

DANFOSS COMPRESSORS

Yellow background

198 - 254 /50

Motor type

RSIR/CSIR

Max. ambient temperature

°C

Comp. cooling at ambient temp.

38*

32°C

S

38°C

S

S O F1

* run capacitor 4 µF compulsory in 38°C ambient temperature

F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

Design Displacement

cm 3

Oil quantity

cm 3

180

g

400

cm3

1790

kg

7.8

Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment

6.49

ø16

Motor size

watt

140

LRA (rated after 4 sec. UL984) LST

A

5.2

Cut-in current LST

A

9.9

Resistance, main and start winding (25°C)



13.9/15.3

Dimensions Height

ø9

EN 60335-2-34 with Annex AA

A

173

B

169

Suction connector

location/I.D. mm

C

6.2 ±0.09

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

5.0 +0.12/+0.20

C

D

222 176

E ° 31.5 28°

mm

170 178 186 204

30°

Approvals

35 70 100

Motor

Compressors on a pallet

pcs.

105

105 107

A B

125

102

June 2001

86

CG.42.F2.02

CK.40.B7.02

71

29

51 20° °

45°

157 60.5 66

8244

96 117

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C TLES7F

-35 66

-30 89

-25 120

watt -23.3 133

-20 160

-15 208

-10 264 g

Capacity (ASHRAE) Comp.\°C TLES7F

-35 81

-30 109

watt -25 148

-23.3 163

-20 197

-15 256

-10 326

-25 127

-23.3 134

-20 148

-15 170

-10 192

-25 0.89

-23.3 0.91

-20 0.96

-15 1.03

-10 1.12

Power consumption Comp.\°C TLES7F

-35 89

-30 107

-35 0.79

-30 0.84

-35 0.74

-35 0.91

d Main winding a1 Start winding N

W/W

-30 0.83

-25 0.94

-23.3 0.99

-20 1.08

-15 1.22

-10 1.37

-30 1.02

-25 1.16

-23.3 1.22

-20 1.33

-15 1.51

-10 1.69

COP (ASHRAE) Comp.\°C TLES7F

a1

A

COP (EN 12900/CECOMAF) Comp.\°C TLES7F

8217

watt

Current consumption Comp.\°C TLES7F

b

N

L

C

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Static cooling, 220V 50Hz, PTC consumption incl.

EN 12900/CECOMAF 55°C 32°C 55°C

Winding protector

(pos.1)

ASHRAE 55°C 32°C 32°C

g

Accessories

e

b 8223

Devices

Fig.

TLES7F

PTC star ting device

6.3 mm spades a1 4.8 mm spades (pos.1)

103N0011 103N0018

PTC star ting device

6.3 mm spades a1 4.8 mm spades (pos.2)

103N0016* 103N0021*

Cover

b

103N2010

Cord relief

d

103N1010

e

117-7117* 117-7119*

a1 d e Main winding

N

a1 Start winding

S

Run capacitor 4 µF 6.3 mm spades 4.8 mm spades Protection screen for PTC Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

g

N

C

L

103N0476 118-1917 118-1918 118-1919

Winding protector

(pos.2)

* run capacitor 4 µF compulsory in 38°C ambient temperature

2

August 2003

CG.42.F2.02

CK.40.B7.02

June 2001

87

NLE6F Energy-optimized Compressor R134a 220-240V 50Hz Data Sheet (Replaces CD.43.K4.02) General NLE6F

Code number

105G6607

105G

NLE6F Application

R134a

Blue stripe Approvals

Application Application Evaporating temperature range Voltage range

°C V/Hz

LBP

Barcode on white background

-35 to -10

Yellow background

6607

DANFOSS COMPRESSORS

8279

Compressor

198 - 254 /50

Motor type

RSIR/RSCR

Max. ambient temperature Comp. cooling at ambient temp.

°C

38

32°C

S

38°C

S

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

Design Displacement

cm3

6.13

Oil quantity

cm 3

290

Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment

g

400

cm3

2310

kg

10.2 204 170

Motor watt

140

LRA (rated after 4 sec. UL984) LST

A

5.0

Cut-in current LST

A

9.4

Resistance, main and start winding (25°C)



Approvals

100 70

Motor size

14.9/17.9

ø16

EN 60335-2-34 with Annex AA

178

D

205

E

Dimensions

C

6.2 ±0.09

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

5.0 +0.12/+0.20

pcs.

A B

102.5

C

80

75.5

191

location/I.D. mm

25°

B Suction connector

Compressors on a pallet

197

15°

A

35°

mm

93.5

Height

254

113

July 2001

88

CD.43.K5.02

CK.40.B7.02

27°

47°

54 78

51°

72

166

60.5

8248

119 127

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C NLE6F

-35 57

-30 80

-25 112

watt -23.3 124

-20 151

-15 198

-10 252 g

Capacity (ASHRAE) Comp.\°C NLE6F

-35 70

watt

-30 99

-25 138

-23.3 153

-20 186

-15 244

-25 108

-23.3 115

-20 129

-15 153

-10 179

-25 0.70

-23.3 0.73

-20 0.77

-15 0.86

-10 0.95

Power consumption Comp.\°C NLE6F

-35 71

-30 89

-10 311

-35 0.59

-30 0.64

-35 0.80

-35 0.99

d Main winding a1 Start winding N

W/W

-30 0.91

-25 1.04

-23.3 1.08

-20 1.17

-15 1.29

-30 1.12

-25 1.27

-23.3 1.33

-20 1.44

-15 1.60

COP (ASHRAE) Comp.\°C NLE6F

a1

A

COP (EN 12900/CECOMAF) Comp.\°C NLE6F

8217

watt

Current consumption Comp.\°C NLE6F

b

-10 1.41

N

L

C

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Static cooling, 220V 50Hz, PTC consumption incl.

EN 12900/CECOMAF 55°C 32°C 55°C

-10 1.74

Winding protector

(pos.1)

ASHRAE 55°C 32°C 32°C

g

e

b 8223

Accessories Devices

Fig.

NLE6F

a1

PTC star ting device

6.3 mm spades a1 4.8 mm spades (pos.1)

103N0011 103N0018

PTC star ting device

6.3 mm spades a1 4.8 mm spades (pos.2)

103N0016 103N0021

Cover

b

103N2010

Cord relief

d

103N1010

Run capacitor 4 µF (optional) 6.3 mm spades 4.8 mm spades

e

117-7117 117-7119

Protection screen for PTC

g

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

d e Main winding

N

N

a1 Start winding

S

C

L

103N0476 118-1917 118-1918 118-1919

Winding protector

(pos.2)

CD.43.K5.02

CK.40.B7.02

July 2001

89

NLE7F Energy-optimized Compressor R134a 220-240V 50Hz Data Sheet (Replaces CG.43.N2.02) General NLE7F

Code number

105G6702

105G

NLE7F Application

R134a

Blue stripe Approvals

Application Application Evaporating temperature range Voltage range

°C V/Hz

LBP

Barcode on white background

-35 to -10

Yellow background

6702

DANFOSS COMPRESSORS

8279-2

Compressor

198 - 254 /50

Motor type

RSIR/RSCR

Max. ambient temperature Comp. cooling at ambient temp.

°C

38

32°C

S

38°C

S

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

Design Displacement

cm3

7.27

Oil quantity

cm 3

290

Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment

g

400

cm3

2310

kg

10.1 204 170

Motor watt

140

LRA (rated after 4 sec. UL984) LST

A

5.0

Cut-in current LST

A

9.4

Resistance, main and start winding (25°C)



Approvals

100 70

Motor size

14.9/17.9

ø16

EN 60335-2-34 with Annex AA

178

D

205

E

Dimensions

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

5.0 +0.12/+0.20

Compressors on a pallet

pcs.

A B

102.5

6.2 ±0.09

location/I.D. mm

80

75.5

C

Suction connector

15°

197 191

35°

A B

25°

mm

93.5

Height

C

254

113

November 2001

90

CG.43.N3.02

CK.40.B7.02

27°

47°

54 78

51°

72

166

60.5

8248

119 127

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C NLE7F

-35 68

-30 97

-25 135

watt -23.3 150

-20 182

-15 238

-10 302 g

Capacity (ASHRAE) Comp.\°C NLE7F

-35 84

watt

-30 119

-25 166

-23.3 185

-20 224

-15 293

-25 131

-23.3 139

-20 156

-15 181

-10 207

-25 0.80

-23.3 0.83

-20 0.88

-15 0.98

-10 1.09

Power consumption Comp.\°C NLE7F

-35 84

-30 107

-10 373

-35 0.66

-30 0.72

-35 0.81

-35 1.00

d Main winding a1 Start winding N

W/W

-30 0.90

-25 1.03

-23.3 1.08

-20 1.17

-15 1.32

-30 1.11

-25 1.27

-23.3 1.33

-20 1.44

-15 1.62

COP (ASHRAE) Comp.\°C NLE7F

a1

A

COP (EN 12900/CECOMAF) Comp.\°C NLE7F

8217

watt

Current consumption Comp.\°C NLE7F

b

-10 1.46

N

L

C

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Static cooling, 220V 50Hz, PTC consumption incl.

EN 12900/CECOMAF 55°C 32°C 55°C

-10 1.80

Winding protector

(pos.1)

ASHRAE 55°C 32°C 32°C

g

e

b 8223

Accessories Devices

Fig.

NLE7F

a1

PTC star ting device

6.3 mm spades a1 4.8 mm spades (pos.1)

103N0011 103N0018

PTC star ting device

6.3 mm spades a1 4.8 mm spades (pos.2)

103N0016 103N0021

Cover

b

103N2010

Cord relief

d

103N1010

Run capacitor 4 µF (optional) 6.3 mm spades 4.8 mm spades

e

117-7117 117-7119

Protection screen for PTC

g

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

d e Main winding

N

N

a1 Start winding

S

C

L

103N0476 118-1917 118-1918 118-1919

Winding protector

(pos.2)

CG.43.N3.02

CK.40.B7.02

November 2001

91

NLE8FK Energy-optimized Compressor R134a 220-240V 50Hz Data Sheet (Replaces CG.43.S1.02) General NLE8FK

Code number

105G6827

105G

NLE8FK Application

R134a

Blue stripe Approvals

Application Application Evaporating temperature range Voltage range

°C V/Hz

LBP

Barcode on white background

-35 to -10

Yellow background

6827

DANFOSS COMPRESSORS

8279-4

Compressor

198 - 254 /50

Motor type

RSIR/RSCR

Max. ambient temperature Comp. cooling at ambient temp.

°C

38

32°C

S

38°C

S

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

Design Displacement

cm 3

Oil quantity

cm 3

320

g

400

cm3

2230

kg

9.8

Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment

8.05

204 170

Motor size

watt

165

LRA (rated after 4 sec. UL984) LST

A

5.8

Cut-in current LST

A

9.8

Resistance, main and start winding (25°C)



12.9/18.0

Approvals

100 70

Motor

ø16

EN 60335-2-34 with Annex AA

178

D

205

E

Dimensions

C

6.2 ±0.09

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

5.0 +0.12/+0.20

pcs.

A B

102.5

C

80

75.5

191

location/I.D. mm

25°

B Suction connector

Compressors on a pallet

197

15°

A

35°

mm

93.5

Height

254

113

July 2001

92

CG.43.S2.02

CK.40.B7.02

27°

47°

54 78

51°

72

166

60.5

8248

119 127

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C NLE8FK

-35 82

-30 112

-25 149

watt -23.3 163

-20 194

-15 249

-10 317 g

Capacity (ASHRAE) Comp.\°C NLE8FK

-35 101

watt

-30 139

-25 184

-23.3 201

-20 240

-15 308

-10 392

-25 145

-23.3 152

-20 167

-15 191

-10 218

-25 1.00

-23.3 1.02

-20 1.08

-15 1.17

-10 1.28

Power consumption Comp.\°C NLE8FK

-35 109

-30 126

-35 0.88

-30 0.93

-35 0.75

-35 0.92

d Main winding a1 Start winding N

W/W

-30 0.89

-25 1.03

-23.3 1.07

-20 1.16

-15 1.30

-10 1.45

-30 1.10

-25 1.27

-23.3 1.32

-20 1.43

-15 1.61

-10 1.80

COP (ASHRAE) Comp.\°C NLE8FK

a1

A

COP (EN 12900/CECOMAF) Comp.\°C NLE8FK

8217

watt

Current consumption Comp.\°C NLE8FK

b

N

L

C

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Static cooling, 220V 50Hz, PTC consumption incl.

EN 12900/CECOMAF 55°C 32°C 55°C

Winding protector

(pos.1)

ASHRAE 55°C 32°C 32°C

g

e

b 8223

Accessories Devices

Fig.

NLE8FK

PTC star ting device

6.3 mm spades a1 4.8 mm spades (pos.1)

103N0011 103N0018

PTC star ting device

6.3 mm spades a1 4.8 mm spades (pos.2)

103N0016 103N0021

Cover

b

103N2010

Cord relief

d

103N1010

Run capacitor 4 µF (optional) 6.3 mm spades 4.8 mm spades

e

117-7117 117-7119

Protection screen for PTC

g

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

a1 d e Main winding

N

N

a1 Start winding

S

C

L

103N0476 118-1917 118-1918 118-1919

Winding protector

(pos.2)

CG.43.S2.02

CK.40.B7.02

July 2001

93

NLE9F Energy-optimized Compressor R134a 220-240V 50Hz Data Sheet (Replaces CG.43.O1.02) General NLE9F

105G

NLE9F

Code number

105G6803

Code number

105G6805* ) *) Performance data established on 8.2 mm suction line. Restrictions due to 6.2 mm suction line can affect system performance.

Application

Application

R134a

Blue stripe Approvals

6803

Barcode on white background

DANFOSS COMPRESSORS

Yellow background

Application

8279-3

Compressor

LBP

Evaporating temperature range Voltage range

°C

-35 to -10

V/Hz

198 - 254 /50

Motor type

S O F1

RSIR/RSCR

Max. ambient temperature

°C

Comp. cooling at ambient temp.

38

32°C

S

38°C

S

Displacement

cm3

8.35

Oil quantity

cm 3

290

F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

Design

Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment

g

400

cm3

2310

kg

10.1

watt

165

204 170

Motor size

100 70

Motor LRA (rated after 4 sec. UL984) LST

A

6.4

Cut-in current LST

A

10.7

Resistance, main and start winding (25°C)



12.9/18.0

Approvals

ø16

EN 60335-2-34 with Annex AA

178

D

205

E C

A B

location/I.D. mm

C 8.2 ±0.09

Process connector

location/I.D. mm

D 6.2 ±0.09

6.2 ±0.09

Discharge connector

location/I.D. mm

E 6.2 ±0.09

5.0 +0.12/+0.20

pcs.

254

80

8248

51°

72

166

Compressors on a pallet

6.2 ±0.09

102.5

Suction connector

113

August 2001

94

CG.43.O2.02

CK.40.B7.02

75.5

191

27°

47°

54 78

B

15°

197

25°

105G6805

A

93.5

105G6803 mm

35°

Height

60.5

Dimensions

119 127

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C NLE9F

-35 82

-30 112

-25 154

watt -23.3 171

-20 207

-15 271

-10 346 g

Capacity (ASHRAE) Comp.\°C NLE9F

-35 101

watt

-30 138

-25 190

-23.3 210

-20 255

-15 334

-10 427

-25 150

-23.3 159

-20 177

-15 206

-10 237

-25 1.09

-23.3 1.15

-20 1.27

-15 1.48

-10 1.73

Power consumption Comp.\°C NLE9F

-35 102

-30 125

-35 0.85

-30 0.95

-35 0.80

-35 0.99

d Main winding a1 Start winding N

W/W

-30 0.90

-25 1.03

-23.3 1.08

-20 1.17

-15 1.31

-10 1.46

-30 1.11

-25 1.27

-23.3 1.32

-20 1.44

-15 1.62

-10 1.80

COP (ASHRAE) Comp.\°C NLE9F

a1

A

COP (EN 12900/CECOMAF) Comp.\°C NLE9F

8217

watt

Current consumption Comp.\°C NLE9F

b

N

L

C

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Static cooling, 220V 50Hz, PTC consumption incl.

EN 12900/CECOMAF 55°C 32°C 55°C

Winding protector

(pos.1)

ASHRAE 55°C 32°C 32°C

g

e

b 8223

Accessories Devices

Fig.

NLE9F

a1

PTC star ting device

6.3 mm spades a1 4.8 mm spades (pos.1)

103N0011 103N0018

PTC star ting device

6.3 mm spades a1 4.8 mm spades (pos.2)

103N0016 103N0021

Cover

b

103N2010

Cord relief

d

103N1010

Run capacitor 4 µF (optional) 6.3 mm spades 4.8 mm spades

e

117-7117 117-7119

Protection screen for PTC

g

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

d e Main winding

N

N

a1 Start winding

S

C

L

103N0476 118-1917 118-1918 118-1919

Winding protector

(pos.2)

CG.43.O2.02

CK.40.B7.02

August 2001

95

TLY4F High Energy-optimized Compressor R134a 220-240V 50Hz Data Sheet (Replaces CD.42M7.02) General TLY4F

Code number

102G4441

Application

R134a SUCTION CONNECTOR

Blue stripe

Application

102G

TLY4F

4441

Approvals

Application

LBP

Evaporating temperature range Voltage range

°C

-35 to -10

V/Hz

Barcode on white background

8278

Compressor

DANFOSS COMPRESSORS

Yellow background

198 - 254 /50

Motor type

RSCR/RSIR

Max. ambient temperature Comp. cooling at ambient temp.

°C

43

32°C

S

38°C

S

43°C

S

Displacement

cm3

3.86

Oil quantity

cm 3

180

g

400

3

1790

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

Design

Maximum refrigerant charge Free gas vol. in compressor

cm

Weight without electrical equipment

kg

7.6 ø16

Motor size LRA (rated after 4 sec. UL984) LST

watt

80

A

2.9

Cut-in current LST

A

7.6

Resistance, main and start winding (25°C)



25.7/15.7

Approvals

170 178 186 204

C

C

6.2 ±0.09

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

5.0 +0.12/+0.20

pcs.

A B

105 107

location/I.D. mm

Process connector

E 30°

173 169

° 31.5 28°

A B

D

222 176

105

mm

Suction connector

Compressors on a pallet

ø9

EN 60335-2-34 with Annex AA

Dimensions Height

35 70 100

Motor

125

102

August 2003

96

CD.42.M8.02

CK.40.B7.02

71

29

51 20° °

45°

157 60.5 66

8244

96 117

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C TLY4F

-35 34.6

-30 51.5

-25 72.0

watt -23.3 79.9

-20 96.8

-15 126

-10 162 g

Capacity (ASHRAE) Comp.\°C TLY4F

-35 42.6

watt

-30 63.5

-25 88.9

-23.3 98.6

-20 119

-15 156

-25 73.0

-23.3 76.5

-20 83.6

-15 95.2

-10 108

-25 0.36

-23.3 0.37

-20 0.41

-15 0.46

-10 0.52

Power consumption Comp.\°C TLY4F

-35 54.4

-30 63.4

-10 200

-35 0.27

-30 0.31

-35 0.63

-35 0.78

d Main winding a1 Start winding N

W/W

-30 0.81

-25 0.99

-23.3 1.04

-20 1.16

-15 1.33

-30 1.00

-25 1.22

-23.3 1.29

-20 1.43

-15 1.64

COP (ASHRAE) Comp.\°C TLY4F

a1

A

COP (EN 12900/CECOMAF) Comp.\°C TLY4F

8217

watt

Current consumption Comp.\°C TLY4F

b

-10 1.49

N

W/W -10 1.85

Winding protector

(pos.1)

Test conditions EN 12900/CECOMAF ASHRAE Condensing temperature 55°C 55°C Ambient and suction gas temp. 32°C 32°C Liquid temperature 55°C 32°C Static cooling, with RC 4 µF, 220V 50Hz, PTC consumption included (two watt power consumption to be subtracted, when ePTC is used; this is also affecting the COP)

g

Accessories Fig. 6.3 mm spades a1 4.8 mm spades (pos.1)

ePTC star ting device 4.8 mm spades PTC star ting device

a1

6.3 mm spades (pos.2) 4.8 mm spades

8223

TLY4F 103N0011 103N0018

103N2010

Cord relief

d

103N1010

Run capacitor 4 µF (optional) 6.3 mm spades 4.8 mm spades

e

117-7117 117-7119

Protection screen for PTC

g

August 2003

d e

103N0016 103N0021

b

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

a1

103N0050

Cover

2

e

b

Devices PTC star ting device

L

C

Main winding

N

N

a1 Start winding

S

C

L

103N0476 118-1917 118-1918 118-1919

(pos.2)

CD.42.M8.02

CK.40.B7.02

Winding protector

August 2003

97

TLY5FK High Energy-optimized Compressor R134a 220-240V 50Hz Data Sheet (Replaces CG.42.I3.02) General TLY5FK

Code number

102G4547

Application

R134a SUCTION CONNECTOR

Blue stripe

Application

102G

TLY5FK

4547

Approvals

Application

LBP

Evaporating temperature range Voltage range

°C

-35 to -10

V/Hz

Barcode on white background

8278-2

Compressor

DANFOSS COMPRESSORS

Yellow background

198 - 254 /50

Motor type

RSCR/RSIR

Max. ambient temperature

°C

Comp. cooling at ambient temp.

43*

32°C

S O F1

S

38°C

S

43°C

S

F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

* run capacitor 4 µF compulsory in 43°C ambient temperature

Design Displacement

cm3

5.08

Oil quantity

cm 3

180

g

400

3

1790

Maximum refrigerant charge Free gas vol. in compressor

cm

Weight without electrical equipment

kg

7.6 ø16

Motor size

watt

105

LRA (rated after 4 sec. UL984) LST

A

4.0

Cut-in current LST

A

8.5

Resistance, main and start winding (25°C)



18.9/15.3

Approvals

170 178 186 204

C

C

6.2 ±0.09

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

5.0 +0.12/+0.20

pcs.

A B

105 107

location/I.D. mm

Process connector

E 30°

173 169

° 31.5 28°

A B

D

222 176

105

mm

Suction connector

Compressors on a pallet

ø9

EN 60335-2-34 with Annex AA

Dimensions Height

35 70 100

Motor

125

102

August 2003

98

CG.42.I4.02

CK.40.B7.02

71

29

51 20° °

45°

157 60.5 66

8244

96 117

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C TLY5FK

-35 49.9

-30 71.5

-25 98.0

watt -23.3 108

-20 130

-15 169

-10 216 g

Capacity (ASHRAE) Comp.\°C TLY5FK

-35 61.5

watt

-30 88.1

-25 121

-23.3 134

-20 161

-15 209

-10 267

-25 97.0

-23.3 102

-20 112

-15 128

-10 146

-25 0.55

-23.3 0.57

-20 0.62

-15 0.68

-10 0.76

Power consumption Comp.\°C TLY5FK

-35 71.4

-30 83.6

-35 0.43

-30 0.49

-35 0.70

-35 0.86

d Main winding a1 Start winding N

W/W

-30 0.85

-25 1.01

-23.3 1.06

-20 1.17

-15 1.32

-30 1.05

-25 1.25

-23.3 1.31

-20 1.44

-15 1.64

COP (ASHRAE) Comp.\°C TLY5FK

a1

A

COP (EN 12900/CECOMAF) Comp.\°C TLY5FK

8217

watt

Current consumption Comp.\°C TLY5FK

b

-10 1.48

N

W/W -10 1.83

Winding protector

(pos.1)

Test conditions EN 12900/CECOMAF ASHRAE Condensing temperature 55°C 55°C Ambient and suction gas temp. 32°C 32°C Liquid temperature 55°C 32°C Static cooling, with RC 4 µF, 220V 50Hz, PTC consumption included (two watt power consumption to be subtracted, when ePTC is used; this is also affecting the COP)

g

8223

Devices

Fig. 6.3 mm spades a1 4.8 mm spades (pos.1)

ePTC star ting device 4.8 mm spades PTC star ting device

e

b

Accessories PTC star ting device

L

C

a1

6.3 mm spades (pos.2) 4.8 mm spades

TLY5FK 103N0011 103N0018 d

103N0050* e

103N0016* 103N0021*

Cover

b

103N2010

Cord relief

d

103N1010

Run capacitor 4 µF (optional) 6.3 mm spades 4.8 mm spades

e

117-7117* 117-7119*

Protection screen for PTC

g

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

a1

Main winding

N

N

a1 Start winding

S

C

L

103N0476 118-1917 118-1918 118-1919

(pos.2)

Winding protector

* run capacitor 4 µF compulsory in 43°C ambient temperature

2

August 2003

CG.42.I4.02

CK.40.B7.02

August 2003

99

TLX6FK High Energy-optimized Compressor R134a 220-240V 50Hz Data Sheet (Replaces CG.42.U1.02) General TLX6FK

Code number

102G4656

Application

102G

TLX6FK R134a SUCTION CONNECTOR

Blue stripe

Application

4656

Approvals

Application

LBP

Evaporating temperature range Voltage range

°C

-35 to -10

V/Hz

Barcode on white background

RSCR* °C

Comp. cooling at ambient temp.

DANFOSS COMPRESSORS

Yellow background

198 - 254 /50

Motor type Max. ambient temperature

8421

Compressor

S O F1

38

32°C

S

38°C

S

F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

* run capacitor 4 µF compulsory

Design Displacement

cm3

5.70

Oil quantity

cm 3

180

g

400

3

1790

Maximum refrigerant charge Free gas vol. in compressor

cm

Weight without electrical equipment

kg

8.2 ø16

Motor watt

117

LRA (rated after 4 sec. UL984) LST

A

3.6

Cut-in current LST

A

8.4

Resistance, main and start winding (25°C)



Approvals

35 70 100

Motor size

19.0/13.0

ø9

EN 60335-2-34 with Annex AA

170 178 186 204

Dimensions A

173

B

169

Suction connector

location/I.D. mm

C

6.2 ±0.09

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

5.0 +0.12/+0.20

C

D

222 176

E ° 31.5 28°

mm

30°

Height

Compressors on a pallet

pcs.

105

105 107

A B

125

102

August 2003

100

CG.42.U3.02

CK.40.B7.02

71

29

51 20° °

45°

157 60.5 66

8244

96 117

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C TLX6FK

-35 59.5

-30 84.9

-25 115

watt -23.3 126

-20 151

-15 193

-10 243

Capacity (ASHRAE) Comp.\°C TLX6FK

-35 73.4

g

watt

-30 105

-25 142

-23.3 156

-20 186

-15 238

e

-10 300 b 8223

Power consumption Comp.\°C TLX6FK

-35 71.9

watt

-30 87.1

-25 103

-23.3 108

-20 119

-15 136

a1

-10 156 d

Current consumption Comp.\°C TLX6FK

-35 0.35

-30 0.42

-23.3 0.51

-20 0.57

-15 0.65

COP (EN 12900/CECOMAF) Comp.\°C TLX6FK

-35 0.83

-10 0.75

-35 1.02

Main winding

N

a1 Start winding

S

W/W

-30 0.97

-25 1.12

-23.3 1.17

-20 1.27

-15 1.41

-10 1.56

-30 1.20

-25 1.38

-23.3 1.45

-20 1.57

-15 1.75

-10 1.93

COP (ASHRAE) Comp.\°C TLX6FK

e

A -25 0.49

N

C

L

W/W Winding protector

Test conditions EN 12900/CECOMAF ASHRAE Condensing temperature 55°C 55°C Ambient and suction gas temp. 32°C 32°C Liquid temperature 55°C 32°C Static cooling, with RC 4 µF, 220V 50Hz, PTC consumption included (two watt power consumption to be subtracted, when ePTC is used; this is also affecting the COP)

Accessories Devices

Fig.

ePTC star ting device

4.8 mm spades

PTC star ting device

6.3 mm spades 4.8 mm spades

TLX6FK 103N0050

a1

103N0016 103N0021

Cover

b

103N2010

Cord relief

d

103N1010

Run capacitor 4 µF (compulsory) 6.3 mm spades 4.8 mm spades

e

117-7117 117-7119

Protection screen for PTC

g

103N0476

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

118-1917 118-1918 118-1919

CG.42.U3.02

CK.40.B7.02

August 2003

101

NLY5.5FK High Energy-optimized Compressor R134a 220-240V 50Hz Data Sheet (Replaces CG.43.R4.02) General NLY5.5FK

Code number

105G6631

Application

R134a SUCTION CONNECTOR

Blue stripe

Application

105G

NLY5.5FK

6631

Approvals

Application

LBP

Evaporating temperature range Voltage range

°C

-35 to -10

V/Hz

Barcode on white background

DANFOSS COMPRESSORS

8280-4

Compressor

Yellow background

198 - 254 /50

Motor type

RSCR*

Max. ambient temperature Comp. cooling at ambient temp.

°C

43

32°C

S

38°C

S

43°C

S

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

* run capacitor 4 µF compulsory

Design Displacement

cm3

6.13

Oil quantity

cm 3

290

g

400

3

2310

kg

10.8

watt

135

Maximum refrigerant charge Free gas vol. in compressor

cm

Weight without electrical equipment

204 170

Motor size LRA (rated after 4 sec. UL984) LST

A

4.3

Cut-in current LST

A

8.3

Resistance, main and start winding (25°C)



16.0/15.1

Approvals

EN 60335-2-34 with Annex AA

100 70

Motor

ø16 178

D

205

E C

location/I.D. mm

C

6.2 ±0.09

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

5.0 +0.12/+0.20

Compressors on a pallet

pcs.

102.5

Suction connector

A B

75.5

203 197

15°

A B

93.5

mm

35°

Height

25°

Dimensions

254

80

113

August 2003

102

CG.43.R5.02

CK.40.B7.02

27°

47°

54 78

51°

72

166

60.5

8250

119 127

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C NLY5.5FK

-35 57.8

-30 87.3

-25 123

watt

-23.3 137

-20 166

-15 218

-10 280 g

Capacity (ASHRAE) Comp.\°C NLY5.5FK

-35 71.2

e

watt

-30 108

-25 152

-23.3 169

-20 205

-15 269

-10 346 b 8223

Power consumption Comp.\°C NLY5.5FK

-35 72.9

-30 87.7

watt -25 104

-23.3 110

-20 121

-15 140

a1

-10 160 d

Current consumption Comp.\°C NLY5.5FK

-35 0.33

-30 0.41

-23.3 0.51

-20 0.56

-15 0.65

-10 0.73

COP (EN 12900/CECOMAF) Comp.\°C NLY5.5FK

-35 0.79

-35 0.98

Main winding

N

a1 Start winding

S

W/W

-30 0.99

-25 1.18

-23.3 1.25

-20 1.37

-15 1.56

-10 1.75

-30 1.23

-25 1.46

-23.3 1.54

-20 1.69

-15 1.92

-10 2.16

COP (ASHRAE) Comp.\°C NLY5.5FK

e

A -25 0.48

N

C

L

W/W Winding protector

Test conditions EN 12900/CECOMAF ASHRAE Condensing temperature 55°C 55°C Ambient and suction gas temp. 32°C 32°C Liquid temperature 55°C 32°C Static cooling, with RC 4 µF, 220V 50Hz, PTC consumption included (two watt power consumption to be subtracted, when ePTC is used; this is also affecting the COP)

Accessories Devices

Fig.

ePTC star ting device 4.8 mm spades PTC star ting device

6.3 mm spades 4.8 mm spades

NLY5.5FK 103N0050

a1

103N0016 103N0021

Cover

b

103N2010

Cord relief

d

103N1010

Run capacitor 4 µF (compulsory) 6.3 mm spades 4.8 mm spades

e

117-7117 117-7119

Protection screen for PTC

g

103N0476

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

118-1917 118-1918 118-1919

CG.43.R5.02

CK.40.B7.02

August 2003

103

NLY6F High Energy-optimized Compressor R134a 220-240V 50Hz Data Sheet (Replaces CD.43.H6.02) General NLY6F

Code number

105G6630

Application

R134a SUCTION CONNECTOR

Blue stripe

Application

105G

NLY6F

6630

Approvals

Application

LBP

Evaporating temperature range Voltage range

°C

-35 to -10

V/Hz

Barcode on white background

DANFOSS COMPRESSORS

8280

Compressor

Yellow background

198 - 254 /50

Motor type

RSCR*

Max. ambient temperature Comp. cooling at ambient temp.

°C

43

32°C

S

38°C

S

43°C

S

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

* run capacitor 4 µF compulsory

Design Displacement

cm3

6.70

Oil quantity

cm 3

290

g

400

3

2310

kg

10.8

watt

135

Maximum refrigerant charge Free gas vol. in compressor

cm

Weight without electrical equipment

204 170

Motor size LRA (rated after 4 sec. UL984) LST

A

4.3

Cut-in current LST

A

8.3

Resistance, main and start winding (25°C)



16.0/15.1

Approvals

EN 60335-2-34 with Annex AA

100 70

Motor

ø16 178

D

205

E C

location/I.D. mm

C

6.2 ±0.09

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

5.0 +0.12/+0.20

Compressors on a pallet

pcs.

102.5

Suction connector

A B

75.5

203 197

15°

A B

93.5

mm

35°

Height

25°

Dimensions

254

80

113

August 2003

104

CD.43.H7.02

CK.40.B7.02

27°

47°

54 78

51°

72

166

60.5

8250

119 127

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C NLY6F

-35 80

-30 104

-25 138

watt

-23.3 152

-20 182

-15 235

-10 299 g

Capacity (ASHRAE) Comp.\°C NLY6F

-35 98

e

watt

-30 128

-25 170

-23.3 187

-20 224

-15 290

-10 369 b 8223

Power consumption Comp.\°C NLY6F

-35 81

-30 99

watt -25 118

-23.3 125

-20 138

-15 159

a1

-10 181 d

Current consumption Comp.\°C NLY6F

-35 0.38

-30 0.47

-23.3 0.57

-20 0.63

-15 0.72

-10 0.81

COP (EN 12900/CECOMAF) Comp.\°C NLY6F

-35 0.99

-35 1.21

Main winding

N

a1 Start winding

S

W/W

-30 1.05

-25 1.17

-23.3 1.22

-20 1.32

-15 1.48

-10 1.65

-30 1.30

-25 1.44

-23.3 1.50

-20 1.62

-15 1.82

-10 2.04

COP (ASHRAE) Comp.\°C NLY6F

e

A -25 0.54

N

C

L

W/W Winding protector

Test conditions EN 12900/CECOMAF ASHRAE Condensing temperature 55°C 55°C Ambient and suction gas temp. 32°C 32°C Liquid temperature 55°C 32°C Static cooling, with RC 4 µF, 220V 50Hz, PTC consumption included (two watt power consumption to be subtracted, when ePTC is used; this is also affecting the COP)

Accessories Devices

Fig.

ePTC star ting device 4.8 mm spades PTC star ting device

6.3 mm spades 4.8 mm spades

NLY6F 103N0050

a1

103N0016 103N0021

Cover

b

103N2010

Cord relief

d

103N1010

Run capacitor 4 µF (compulsory) 6.3 mm spades 4.8 mm spades

e

117-7117 117-7119

Protection screen for PTC

g

103N0476

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

118-1917 118-1918 118-1919

CD.43.H7.02

CK.40.B7.02

August 2003

105

NLY7F High Energy-optimized Compressor R134a 220-240V 50Hz Data Sheet (Replaces CG.43.P3.02) General NLY7F

Code number

105G6730

Application

R134a SUCTION CONNECTOR

Blue stripe

Application

105G

NLY7F

6730

Approvals

Application

LBP

Evaporating temperature range Voltage range

°C

-35 to -10

V/Hz

Barcode on white background

DANFOSS COMPRESSORS

8280-2

Compressor

Yellow background

198 - 254 /50

Motor type

RSCR*

Max. ambient temperature Comp. cooling at ambient temp.

°C

43

32°C

S

38°C

S

43°C

S

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

* run capacitor 4 µF compulsory

Design Displacement

cm3

7.27

Oil quantity

cm 3

290

g

400

3

2310

kg

10.8

watt

180

Maximum refrigerant charge Free gas vol. in compressor

cm

Weight without electrical equipment

204 170

Motor size LRA (rated after 4 sec. UL984) LST

A

5.7

Cut-in current LST

A

10.3

Resistance, main and start winding (25°C)



11.8/12.7

Approvals

EN 60335-2-34 with Annex AA

100 70

Motor

ø16 178

D

205

E C

location/I.D. mm

C

6.2 ±0.09

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

5.0 +0.12/+0.20

Compressors on a pallet

pcs.

102.5

Suction connector

A B

75.5

203 197

15°

A B

93.5

mm

35°

Height

25°

Dimensions

254

80

113

August 2003

106

CG.43.P4.02

CK.40.B7.02

27°

47°

54 78

51°

72

166

60.5

8250

119 127

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C NLY7F

-35 94

-30 121

-25 158

watt -23.3 173

-20 206

-15 265

-10 334 g

Capacity (ASHRAE) Comp.\°C NLY7F

-35 116

e

watt

-30 149

-25 195

-23.3 213

-20 254

-15 326

-10 412 b 8223

Power consumption Comp.\°C NLY7F

-35 103

-30 117

watt -25 134

-23.3 140

-20 153

-15 175

a1

-10 200 d

Current consumption Comp.\°C NLY7F

-35 0.47

-30 0.54

-23.3 0.65

-20 0.70

-15 0.80

COP (EN 12900/CECOMAF) Comp.\°C NLY7F

-35 0.91

-35 1.12

-10 0.90

Main winding

N

a1 Start winding

S

W/W

-30 1.03

-25 1.18

-23.3 1.24

-20 1.35

-15 1.51

-30 1.27

-25 1.45

-23.3 1.52

-20 1.66

-15 1.86

COP (ASHRAE) Comp.\°C NLY7F

e

A -25 0.62

-10 1.67

N

C

L

W/W -10 2.06

Winding protector

Test conditions EN 12900/CECOMAF ASHRAE Condensing temperature 55°C 55°C Ambient and suction gas temp. 32°C 32°C Liquid temperature 55°C 32°C Static cooling, with RC 4 µF, 220V 50Hz, PTC consumption included (two watt power consumption to be subtracted, when ePTC is used; this is also affecting the COP)

Accessories Devices

Fig.

ePTC star ting device 4.8 mm spades PTC star ting device

6.3 mm spades 4.8 mm spades

NLY7F 103N0050

a1

103N0016 103N0021

Cover

b

103N2010

Cord relief

d

103N1010

Run capacitor 4 µF (compulsory) 6.3 mm spades 4.8 mm spades

e

117-7117 117-7119

Protection screen for PTC

g

103N0476

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

118-1917 118-1918 118-1919

CG.43.P4.02

CK.40.B7.02

August 2003

107

NLY9FK High Energy-optimized Compressor R134a 220-240V 50Hz Data Sheet (Replaces CG.43.Q2.02) General NLY9FK

Code number

105G6830

Application

R134a SUCTION CONNECTOR

Blue stripe

Application

105G

NLY9FK

6830

Approvals

Application

LBP

Evaporating temperature range Voltage range

°C

-35 to -10

V/Hz

Barcode on white background

DANFOSS COMPRESSORS

8280-3

Compressor

Yellow background

198 - 254 /50

Motor type

RSCR*

Max. ambient temperature Comp. cooling at ambient temp.

°C

43

32°C

S

38°C

S

43°C

S

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

* run capacitor 4 µF compulsory

Design Displacement

cm3

8.35

Oil quantity

cm 3

290

g

400

3

2310

kg

10.8

watt

190

Maximum refrigerant charge Free gas vol. in compressor

cm

Weight without electrical equipment

204 170

Motor size LRA (rated after 4 sec. UL984) LST

A

6.1

Cut-in current LST

A

11.3

Resistance, main and start winding (25°C)



11.0/9.0

Approvals

EN 60335-2-34 with Annex AA

100 70

Motor

ø16 178

D

205

E C

location/I.D. mm

C

8.2 ±0.09

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

6.2 ±0.09

Compressors on a pallet

pcs.

102.5

Suction connector

A B

75.5

203 197

15°

A B

93.5

mm

35°

Height

25°

Dimensions

254

80

113

August 2003

108

CG.43.Q3.02

CK.40.B7.02

27°

47°

54 78

51°

72

166

60.5

8250

119 127

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C NLY9FK

-35 94

-30 130

-25 175

watt -23.3 192

-20 230

-15 297

-10 380 g

Capacity (ASHRAE) Comp.\°C NLY9FK

-35 116

e

watt

-30 161

-25 216

-23.3 237

-20 284

-15 367

-10 469 b 8223

Power consumption Comp.\°C NLY9FK

-35 108

-30 129

watt -25 151

-23.3 160

-20 176

-15 203

a1

-10 232 d

Current consumption Comp.\°C NLY9FK

-35 0.58

-30 0.68

-23.3 0.82

-20 0.90

-15 1.03

-10 1.16

COP (EN 12900/CECOMAF) Comp.\°C NLY9FK

-35 0.87

-35 1.08

Main winding

N

a1 Start winding

S

W/W

-30 1.01

-25 1.15

-23.3 1.20

-20 1.30

-15 1.46

-10 1.63

-30 1.25

-25 1.42

-23.3 1.49

-20 1.61

-15 1.81

-10 2.02

COP (ASHRAE) Comp.\°C NLY9FK

e

A -25 0.79

N

C

L

W/W Winding protector

Test conditions EN 12900/CECOMAF ASHRAE Condensing temperature 55°C 55°C Ambient and suction gas temp. 32°C 32°C Liquid temperature 55°C 32°C Static cooling, with RC 4 µF, 220V 50Hz, PTC consumption included (two watt power consumption to be subtracted, when ePTC is used; this is also affecting the COP)

Accessories Devices

Fig.

ePTC star ting device 4.8 mm spades PTC star ting device

6.3 mm spades 4.8 mm spades

NLY9FK 103N0050

a1

103N0016 103N0021

Cover

b

103N2010

Cord relief

d

103N1010

Run capacitor 4 µF (compulsory) 6.3 mm spades 4.8 mm spades

e

117-7117 117-7119

Protection screen for PTC

g

103N0476

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

118-1917 118-1918 118-1919

CG.43.Q3.02

CK.40.B7.02

August 2003

109

TLV5F Variable Speed Drive Compressor R134a 220-240V 50-60Hz Data Sheet (Replaces CG.42.K3.02) General TLV5F

Code number: Comp. without electronic unit

102G4585

Code number: Electronic unit

105N4001

Application

102G

TLV5F

Application

R134a SUCTION CONNECTOR

Blue stripe

4585

Approvals

LBP

Barcode on white background

-35 to -10

Yellow background

Application Evaporating temperature range Voltage range

°C V/Hz

HST

Comp. cooling at ambient temp.

DANFOSS COMPRESSORS

198 - 254 /50 - 60

Starting characteristics Max. ambient temperature

8396

Compressor

°C

43

32°C

S

38°C

S

43°C

S

S O F1

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

F2

Features Speed range

rpm

2000 - 4000

Control modes with

- mech. thermostat 220V ON/OFF

integrated speed control AEO*)

- 5V DC ON/OFF

External speed control

- 5V DC 200-400Hz

Protections

- current - speed

204 186 178 170

- temperature *)AEO - Adaptive Energy Optimizer

Design

Ø16

ø9 3

Displacement

cm

Oil quantity

cm3

180

g

400

Free gas vol. in compressor Weight: Compressor/Electronic unit

cm3

1790

kg

7.9/0.6

35 70 100

Maximum refrigerant charge

5.08

C

E

permanent magnet

6

Resistance, all 3 windings (25°C)



14.0

Approvals

electronic cut-off A B

105 107

A

105

A

Cut-in current HST

° 31.5 28°

LRA (rated after 4 sec. UL984) HST

30°

Motor type

D

230 176

Motor

EN 60335-2-34 with Annex AA

Dimensions Height

mm

A

173

B

169

C

6.2 ±0.09

D

6.2 ±0.09

location/I.D. mm

E

5.0 +0.12/+0.20

Compressors on a pallet (without el. unit) pcs. July 2001

110

125 CG.42.K4.02

CK.40.B7.02

102

29 71

location/I.D. mm

Discharge connector

51 20° °

Process connector

66

location/I.D. mm

45°

Suction connector

157 120

8394

96 117

1

August 2003

Capacity (EN 12900/CECOMAF) rpm \ °C 2,000 2,500 3,000 4,000

-35 38.3 46.8 53.3 62.6

-30 52.1 63.6 73.6 92.5

watt

-25 70.1 85.7 100 129

-23.3 77.3 95 110 142

-20 92.9 114 133 172

-15 121 149 174 224

-10 155 191 224 287

-25 86.5 106 123 159

-23.3 95 117 136 176

-20 115 141 164 212

-15 150 184 215 277

-10 192 236 276 354

-25 62.1 77.1 92.4 124

-23.3 65.7 81.5 98 131

-20 72.8 90.3 108 146

-15 84.1 104 125 169

-10 96 119 144 194

-25 1.21 1.23 1.24 1.22

-23.3 1.26 1.29 1.30 1.27

-20 1.37 1.40 1.41 1.38

-15 1.54 1.59 1.60 1.53

-10 1.72 1.78 1.80 1.68

Capacity (ASHRAE) rpm \ °C 2,000 2,500 3,000 4,000

-35 47.2 57.6 65.6 77.2

-30 64.2 78.4 90.8 114

watt

Power consumption rpm \ °C 2,000 2,500 3,000 4,000

-35 41.9 52.0 62.2 82.9

-30 51.8 64.4 77.2 103

-35 0.88 0.91 0.92 0.87

-30 1.04 1.06 1.07 1.05

6 10

7 8

-35 1.13 1.11 1.06 0.93

-30 1.01 0.99 0.95 0.89

-25 1.13 1.11 1.08 1.04

-23.3 1.18 1.16 1.13 1.09

-20 1.28 1.26 1.23 1.18

-15 1.44 1.43 1.39 1.33

-30 1.24 1.22 1.18 1.10

-25 1.39 1.37 1.33 1.28

-23.3 1.45 1.43 1.39 1.34

-20 1.57 1.56 1.52 1.46

-15 1.78 1.76 1.72 1.64

M

-10 1.62 1.60 1.56 1.48

R+ R-

2

3 4

f 5

EN 12900/CECOMAF 55°C 32°C 55°C

Legend

-10 2.00 1.98 1.92 1.82

ASHRAE 55°C 32°C 32°C

Accessories Devices Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

August 2003

L N N C C L N

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Static cooling, 220V 50Hz

2

13

1

W/W

COP (ASHRAE) rpm \ °C 2,000 2,500 3,000 4,000

13

8 7

11

-35 0.91 0.90 0.86 0.76

8385-2

14

A

COP (EN 12900/CECOMAF) rpm \ °C 2,000 2,500 3,000 4,000

9

6

watt

Current consumption rpm \ °C 2,000 2,500 3,000 4,000

12 13

TLV5F

Number

Description

1: 2: 3: 4: 5: 6: 7: 8: 9: 10: 11: 12: 13: 14:

Power supply Fan connection Thermostat connection Light connection Signal input Mounting recesses Cover Cord relief Electronic unit Earth connection Connector Compressor Screw 3.5 x 12 mm (3 pcs.) Screw 3.5 x 25 mm (2 pcs.)

(for further descriptions on connecting the electronic unit and the compressor, refer to instruction CI.42.D. "Electronic Unit Type 105N4001 - 198-254V for the TLV Compressor").

118-1917 118-1918 118-1919

CG.42.K4.02

CK.40.B7.02

July 2001

111

TLV6F Variable Speed Drive Compressor R134a 220-240V 50-60Hz Data Sheet (Replaces CG.42.L3.02) General TLV6F

Code number: Comp. without electronic unit

102G4685

Code number: Electronic unit

105N4001

Application

102G

TLV6F

Application

R134a SUCTION CONNECTOR

Blue stripe

4685

Approvals

LBP

Barcode on white background

-35 to -10

Yellow background

Application Evaporating temperature range Voltage range

°C V/Hz

HST

Comp. cooling at ambient temp.

DANFOSS COMPRESSORS

198 - 254 /50 - 60

Starting characteristics Max. ambient temperature

8396-2

Compressor

°C

43

32°C

S

38°C

S

43°C

S

S O F1

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

F2

Features Speed range

rpm

2000 - 4000

Control modes with

- mech. thermostat 220V ON/OFF

integrated speed control AEO*)

- 5V DC ON/OFF

External speed control

- 5V DC 200-400Hz

Protections

- current - speed

204 186 178 170

- temperature *)AEO - Adaptive Energy Optimizer

Design

Ø16

ø9 3

Displacement

cm

Oil quantity

cm3

180

g

400

Free gas vol. in compressor Weight: Compressor/Electronic unit

cm3

1790

kg

7.9/0.6

35 70 100

Maximum refrigerant charge

5.70

C

E

permanent magnet

6

Resistance, all 3 windings (25°C)



14.0

Approvals

electronic cut-off A B

105 107

A

105

A

Cut-in current HST

° 31.5 28°

LRA (rated after 4 sec. UL984) HST

30°

Motor type

D

230 176

Motor

EN 60335-2-34 with Annex AA

Dimensions Height

mm

A

173

B

169

C

6.2 ±0.09

D

6.2 ±0.09

location/I.D. mm

E

5.0 +0.12/+0.20

Compressors on a pallet (without el. unit) pcs. July 2001

112

125 CG.42.L4.02

CK.40.B7.02

102

29 71

location/I.D. mm

Discharge connector

51 20° °

Process connector

66

location/I.D. mm

45°

Suction connector

157 120

8394

96 117

1

August 2003

Capacity (EN 12900/CECOMAF) rpm \ °C 2,000 2,500 3,000 4,000

-35 36.7 44.2 50.9 61.7

-30 53.4 64.8 75.1 92.9

watt

-25 74.5 90.4 105 132

-23.3 82.7 100 117 147

-20 100 122 142 179

-15 132 160 187 237

-25 91.8 111 130 162

-23.3 102 124 144 181

-20 124 150 175 221

-15 163 198 231 292

-10 210 254 297 378

-25 65.5 80.0 94.9 126

-23.3 69.7 85.0 101 134

-20 78.0 95.0 113 150

-15 91.5 111 132 175

-10 106 129 152 203

-25 1.28 1.28 1.27 1.24

-23.3 1.35 1.35 1.34 1.30

-20 1.47 1.48 1.47 1.41

-15 1.67 1.68 1.67 1.57

-10 1.86 1.89 1.88 1.73

Capacity (ASHRAE) rpm \ °C 2,000 2,500 3,000 4,000

-35 45.2 54.5 62.7 76.0

-30 65.9 79.9 92.6 115

-35 43.9 53.0 62.4 82.0

-30 54.1 66.0 78.2 104

-35 0.91 0.91 0.91 0.91

-30 1.09 1.09 1.09 1.07

6 10

7 8

-35 1.03 1.03 1.01 0.93

-30 0.99 0.98 0.96 0.90

-25 1.14 1.13 1.11 1.04

-23.3 1.19 1.18 1.16 1.09

-20 1.29 1.28 1.26 1.20

-15 1.44 1.44 1.42 1.35

-30 1.22 1.21 1.19 1.10

-25 1.40 1.39 1.37 1.29

-23.3 1.46 1.46 1.43 1.35

-20 1.59 1.58 1.56 1.48

-15 1.78 1.78 1.75 1.67

M

-10 1.61 1.60 1.58 1.50

R+ R-

2

3 4

f 5

EN 12900/CECOMAF 55°C 32°C 55°C

Legend

-10 1.99 1.98 1.95 1.86

ASHRAE 55°C 32°C 32°C

Accessories Devices Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

August 2003

L N N C C L N

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Static cooling, 220V 50Hz

2

13

1

W/W

COP (ASHRAE) rpm \ °C 2,000 2,500 3,000 4,000

13

8 7

11

-35 0.84 0.83 0.82 0.75

8385-2

14

A

COP (EN 12900/CECOMAF) rpm \ °C 2,000 2,500 3,000 4,000

9

6

watt

Current consumption rpm \ °C 2,000 2,500 3,000 4,000

12 13

watt

Power consumption rpm \ °C 2,000 2,500 3,000 4,000

-10 170 206 240 306

TLV6F

Number

Description

1: 2: 3: 4: 5: 6: 7: 8: 9: 10: 11: 12: 13: 14:

Power supply Fan connection Thermostat connection Light connection Signal input Mounting recesses Cover Cord relief Electronic unit Earth connection Connector Compressor Screw 3.5 x 12 mm (3 pcs.) Screw 3.5 x 25 mm (2 pcs.)

(for further descriptions on connecting the electronic unit and the compressor, refer to instruction CI.42.D. "Electronic Unit Type 105N4001 - 198-254V for the TLV Compressor").

118-1917 118-1918 118-1919

CG.42.L4.02

CK.40.B7.02

July 2001

113

TLV7F Variable Speed Drive Compressor R134a 220-240V 50-60Hz Data Sheet (Replaces CG.42.M3.02) General TLV7F

Code number: Comp. without electronic unit

102G4785

Code number: Electronic unit

105N4001

Application

102G

TLV7F

Application

R134a SUCTION CONNECTOR

Blue stripe

4785

Approvals

LBP

Barcode on white background

-35 to -10

Yellow background

Application Evaporating temperature range Voltage range

°C V/Hz

HST

Comp. cooling at ambient temp.

DANFOSS COMPRESSORS

198 - 254 /50 - 60

Starting characteristics Max. ambient temperature

8396-3

Compressor

°C

43

32°C

S

38°C

S

43°C

S

S O F1

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

F2

Features Speed range

rpm

2000 - 4000

Control modes with

- mech. thermostat 220V ON/OFF

integrated speed control AEO*)

- 5V DC ON/OFF

External speed control

- 5V DC 200-400Hz

Protections

- current - speed

204 186 178 170

- temperature *)AEO - Adaptive Energy Optimizer

Design

Ø16

ø9 3

Displacement

cm

Oil quantity

cm3

180

g

400

Free gas vol. in compressor Weight: Compressor/Electronic unit

cm3

1790

kg

7.9/0.6

35 70 100

Maximum refrigerant charge

6.49

C

E

permanent magnet

6

Resistance, all 3 windings (25°C)



14.0

Approvals

electronic cut-off A B

105 107

A

105

A

Cut-in current HST

° 31.5 28°

LRA (rated after 4 sec. UL984) HST

30°

Motor type

D

230 176

Motor

EN 60335-2-34 with Annex AA

Dimensions Height

mm

A

173

B

169

C

6.2 ±0.09

D

6.2 ±0.09

location/I.D. mm

E

5.0 +0.12/+0.20

Compressors on a pallet (without el. unit) pcs. July 2001

114

125 CG.42.M4.02

CK.40.B7.02

102

29 71

location/I.D. mm

Discharge connector

51 20° °

Process connector

66

location/I.D. mm

45°

Suction connector

157 120

8394

96 117

1

August 2003

Capacity (EN 12900/CECOMAF) rpm \ °C 2,000 2,500 3,000 4,000

-35 47.5 56.3 64.2 78.3

-30 66.2 80.7 92.8 111

watt

-25 90.0 111 128 153

-23.3 99.3 122 141 170

-20 120 147 171 205

-15 156 192 222 269

-25 111 137 158 189

-23.3 123 151 175 210

-20 148 182 211 253

-15 192 237 274 332

-10 246 302 350 427

-25 78.3 97.6 115 146

-23.3 83.3 104 123 155

-20 93.1 116 137 174

-15 109 136 161 203

-10 125 156 185 235

-25 1.46 1.48 1.47 1.38

-23.3 1.53 1.55 1.55 1.45

-20 1.68 1.70 1.69 1.57

-15 1.91 1.93 1.92 1.73

-10 2.14 2.17 2.15 1.88

Capacity (ASHRAE) rpm \ °C 2,000 2,500 3,000 4,000

-35 58.6 69.3 79.1 96.6

-30 81.7 99.5 114 137

-35 51.8 63.0 74.2 96.2

-30 64.6 79.8 94.2 120

-35 1.05 1.05 1.05 0.97

-30 1.25 1.26 1.26 1.18

6 10

7 8

-35 1.13 1.10 1.07 1.00

-30 1.03 1.01 0.99 0.93

-25 1.15 1.13 1.11 1.05

-23.3 1.19 1.18 1.15 1.09

-20 1.28 1.27 1.24 1.18

-15 1.43 1.41 1.38 1.32

-30 1.27 1.25 1.22 1.14

-25 1.42 1.40 1.37 1.29

-23.3 1.47 1.45 1.42 1.35

-20 1.59 1.56 1.53 1.46

-15 1.77 1.74 1.71 1.63

M

-10 1.59 1.57 1.53 1.47

R+ R-

2

3 4

f 5

EN 12900/CECOMAF 55°C 32°C 55°C

Legend

-10 1.97 1.94 1.90 1.81

ASHRAE 55°C 32°C 32°C

Accessories Devices Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

August 2003

L N N C C L N

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Static cooling, 220V 50Hz

2

13

1

W/W

COP (ASHRAE) rpm \ °C 2,000 2,500 3,000 4,000

13

8 7

11

-35 0.92 0.89 0.87 0.81

8385-2

14

A

COP (EN 12900/CECOMAF) rpm \ °C 2,000 2,500 3,000 4,000

9

6

watt

Current consumption rpm \ °C 2,000 2,500 3,000 4,000

12 13

watt

Power consumption rpm \ °C 2,000 2,500 3,000 4,000

-10 199 245 284 345

TLV7F

Number

Description

1: 2: 3: 4: 5: 6: 7: 8: 9: 10: 11: 12: 13: 14:

Power supply Fan connection Thermostat connection Light connection Signal input Mounting recesses Cover Cord relief Electronic unit Earth connection Connector Compressor Screw 3.5 x 12 mm (3 pcs.) Screw 3.5 x 25 mm (2 pcs.)

(for further descriptions on connecting the electronic unit and the compressor, refer to instruction CI.42.D. "Electronic Unit Type 105N4001 - 198-254V for the TLV Compressor").

118-1917 118-1918 118-1919

CG.42.M4.02

CK.40.B7.02

July 2001

115

TLS3FT Tropical Compressor R134a 220-240V 50Hz Data Sheet (Replaces CD.42.N5.02) General TLS3FT

Code number

102G4324

Application

R134a SUCTION CONNECTOR

Blue stripe

Application

102G

TLS3FT

4324

Approvals

Application

LBP

Evaporating temperature range

°C

Voltage range

-35 to -10

V/Hz

Barcode on white background

8281

Compressor

DANFOSS COMPRESSORS

Yellow background

187 - 254 /50 RSIR*)

Motor type Max. ambient temperature Comp. cooling at ambient temp.

°C

43

32°C

S

38°C

S

43°C

S

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

*) In capillary tube systems where non-equalized pressures may occur at compressor start, or in areas with short power supply drop-outs, a starting capacitor can be used for ensuring a successful start (CSIR).

Design Displacement

cm3

3.13

Oil quantity

cm3

180

Maximum refrigerant charge Free gas vol. in compressor

400

cm3

1790

kg

7.5

ø16

35 70 100

Weight without electrical equipment

g

Motor Motor size

watt

75

LRA (rated after 4 sec. UL984) LST

A

2.6

Cut-in current LST

A

6.9

Resistance, main and start winding (25°C) Ω

ø9 170 178 186 204

27.5/15.1

Approvals

EN 60335-2-34

C

D

222 176

E Dimensions

6.2 ±0.09

Suction connector

location/I.D. mm

C

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

5.0 +0.12/+0.20

Compressors on a pallet

pcs.

A B

105 107

173 169

30°

A B

105

mm

° 31.5 28°

Height

125

102

June 2001

116

CD.42.N6.02

CK.40.B7.02

71

29

51 20° °

45°

157 60.5 66

8244

96 117

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C TLS3FT

-35 21

-30 34

-25 50

watt -23.3 56

-20 69

-15 92

-10 120

HST c

Capacity (ASHRAE) Comp.\°C TLS3FT

-35 26

watt

-30 42

-25 61

-23.3 69

-20 85

-15 114

-10 149 b

Power consumption Comp.\°C TLS3FT

-35 45

watt

-30 53

-25 62

-23.3 65

-20 71

-15 81

8219

-10 92

a2 d

Current consumption Comp.\°C TLS3FT

-35 0.39

-30 0.42

A -25 0.45

-23.3 0.46

-20 0.48

-15 0.52

-10 0.56

c 11

10

COP (EN 12900/CECOMAF) Comp.\°C TLS3FT

-35 0.46

W/W

-30 0.63

-25 0.80

-23.3 0.86

-20 0.97

-15 1.14

-10 1.30

-30 0.78

-25 0.99

-23.3 1.06

-20 1.20

-15 1.41

-10 1.61

COP (ASHRAE) Comp.\°C TLS3FT

-35 0.57

12

13 14

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Static cooling, 220V 50Hz, PTC consumption incl.

EN 12900/CECOMAF 55°C 32°C 55°C

Main winding

ASHRAE 55°C 32°C 32°C

Winding protector Start winding

LST g

b 8217

a1

Accessories Devices

d

Fig.

TLS3FT

a1

103N0011 103N0018

Starting relay

a2

117U6007

Cover

b

103N2010

Starting capacitor 60 µF

c

117U5014

Cord relief

d

103N1010

Protection screen for PTC

g

103N0476

PTC starting device

6.3 mm spades 4.8 mm spades

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

Main winding a1 Start winding N

N

118-1917 118-1918 118-1919

C

L

Winding protector

CD.42.N6.02

CK.40.B7.02

June 2001

117

TLS4FT Tropical Compressor R134a 220-240V 50Hz Data Sheet (Replaces CD.42.X1.02) General TLS4FT

Code number

102G4424

Application

R134a SUCTION CONNECTOR

Blue stripe

Application

102G

TLS4FT

4424

Approvals

Application

LBP

Evaporating temperature range

°C

Voltage range

-35 to -10

V/Hz

Barcode on white background

8281-2

Compressor

DANFOSS COMPRESSORS

Yellow background

187 - 254 /50 RSIR*)

Motor type Max. ambient temperature Comp. cooling at ambient temp.

°C

43

32°C

S

38°C

S

43°C

S

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

*) In capillary tube systems where non-equalized pressures may occur at compressor start, or in areas with short power supply drop-outs, a starting capacitor can be used for ensuring a successful start (CSIR).

Design Displacement

cm3

Oil quantity

cm3

180

g

400

cm3

1790

kg

7.5

Maximum refrigerant charge Free gas vol. in compressor

ø16

35 70 100

Weight without electrical equipment

3.86

Motor Motor size

watt

125

LRA (rated after 4 sec. UL984) LST/HST

A

4.9/5.8

Cut-in current LST/HST

A

8.7/5.8

Resistance, main and start winding (25°C)



ø9 170 178 186 204

16.0/17.0

Approvals

EN 60335-2-34

C

D

222 176

E

Dimensions 169

C

6.2 ±0.09

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

5.0 +0.12/+0.20

Compressors on a pallet

pcs.

30°

173

B

A B

105 107

location/I.D. mm

A

105

Suction connector

mm

° 31.5 28°

Height

125

102

June 2001

118

CD.42.X2.02

CK.40.B7.02

71

29

51 20° °

45°

157 60.5 66

8244

96 117

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C TLS4FT

-35 27

-30 43

-25 63

watt -23.3 71

-20 88

-15 117

-10 152

HST c

Capacity (ASHRAE) Comp.\°C TLS4FT

-35 34

watt

-30 53

-25 78

-23.3 88

-20 108

-15 144

-10 188 b

Power consumption Comp.\°C TLS4FT

-35 68

watt

-30 77

-25 87

-23.3 91

-20 99

-15 110

8219

-10 123

a2 d

Current consumption Comp.\°C TLS4FT

-35 0.78

-30 0.79

A -25 0.82

-23.3 0.82

-20 0.84

-15 0.87

-10 0.91

c 11

10

COP (EN 12900/CECOMAF) Comp.\°C TLS4FT

-35 0.40

W/W

-30 0.56

-25 0.72

-23.3 0.78

-20 0.89

-15 1.06

-10 1.24

-30 0.69

-25 0.89

-23.3 0.96

-20 1.10

-15 1.31

-10 1.53

COP (ASHRAE) Comp.\°C TLS4FT

-35 0.49

12

13 14

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Static cooling, 220V 50Hz, PTC consumption incl.

EN 12900/CECOMAF 55°C 32°C 55°C

Main winding

ASHRAE 55°C 32°C 32°C

Winding protector Start winding

LST g

b 8217

a1

Accessories Devices

d

Fig.

TLS4FT

a1

103N0011 103N0018

Starting relay

a2

117U6004

Cover

b

103N2010

Starting capacitor 60 µF

c

117U5014

Cord relief

d

103N1010

Protection screen for PTC

g

103N0476

PTC starting device

6.3 mm spades 4.8 mm spades

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

Main winding a1 Start winding N

N

118-1917 118-1918 118-1919

C

L

Winding protector

CD.42.X2.02

CK.40.B7.02

June 2001

119

TLS5FT Tropical Compressor R134a 220-240V 50Hz Data Sheet (Replaces CD.42.Y1.02) General TLS5FT

Code number

102G4524

Code number

102G4527

Application

102G

TLS5FT R134a SUCTION CONNECTOR

Blue stripe

4524

Approvals

Application Application

Barcode on white background

LBP

Evaporating temperature range

°C

Voltage range

187 - 254 /50 RSIR*)

Motor type

Comp. cooling at ambient temp.

DANFOSS COMPRESSORS

Yellow background

-35 to -10

V/Hz

Max. ambient temperature

8281-3

Compressor

°C

43

32°C

S

38°C

S

43°C

S

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

*) In capillary tube systems where non-equalized pressures may occur at compressor start, or in areas with short power supply drop-outs, a starting capacitor can be used for ensuring a successful start (CSIR).

Design Displacement

cm3

Oil quantity

cm3

180

g

400

cm3

1790

kg

7.5

Maximum refrigerant charge Free gas vol. in compressor

ø16

35 70 100

Weight without electrical equipment

5.08

Motor Motor size

watt

LRA (rated after 4 sec. UL984) LST/HST

ø9

140

A

170 178 186 204

5.4/5.7

Cut-in current LST/HST

A

9.7/5.7

Resistance, main and start winding (25°C)



14.5/14.8

E 30°

102G4527

A

173

B

169

A B

105 107

102G4524 mm

D

222 176

° 31.5 28°

Dimensions Height

C

EN 60335-2-34

105

Approvals

Suction connector

location/I.D. mm

C 6.2 ±0.09

Process connector

location/I.D. mm

D 6.2 ±0.09

6.5 ±0.09 6.5 ±0.09

Discharge connector

location/I.D. mm

E 5.0 +0.12/+0.20

5.0 +0.12/+0.20

May 2001

120

CD.42.Y2.02

CK.40.B7.02

71

45°

102

29

125

51 20° °

pcs.

157 60.5 66

8244

Compressors on a pallet

96 117

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C TLS5FT

-35 47.8

-30 70.7

-25 98.0

watt -23.3 109

-20 131

-15 170

-10 216

HST c

Capacity (ASHRAE) Comp.\°C TLS5FT

-35 58.9

watt

-30 87.2

-25 121

-23.3 134

-20 161

-15 209

-10 267 b

Power consumption Comp.\°C TLS5FT

-35 84.5

watt

-30 99.2

-25 114

-23.3 120

-20 131

-15 147

8219

-10 165

a2 d

Current consumption Comp.\°C TLS5FT

-35 0.96

-30 0.98

A -25 1.01

-23.3 1.02

-20 1.05

-15 1.10

-10 1.15

c 11

10

COP (EN 12900/CECOMAF) Comp.\°C TLS5FT

-35 0.57

W/W

-30 0.71

-25 0.86

-23.3 0.91

-20 1.00

-15 1.15

-30 0.88

-25 1.06

-23.3 1.12

-20 1.24

-15 1.42

COP (ASHRAE) Comp.\°C TLS5FT

-35 0.70

-10 1.30

12

13 14

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Static cooling, 220V 50Hz, PTC consumption incl.

EN 12900/CECOMAF 55°C 32°C 55°C

-10 1.61

Main winding

ASHRAE 55°C 32°C 32°C

Winding protector Start winding

LST g

b 8217

a1

Accessories Devices

d

Fig.

TLS5FT

a1

103N0011 103N0018

Starting relay

a2

117U6000

PTC starting device

6.3 mm spades 4.8 mm spades

Cover

b

103N2010

Starting capacitor 60 µF

c

117U5014

Cord relief

d

103N1010

Protection screen for PTC

g

103N0476

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

Main winding a1 Start winding N

N

118-1917 118-1918 118-1919

C

L

Winding protector

CD.42.Y2.02

CK.40.B7.02

May 2001

121

TFS4FT Tropical Compressor R134a 220V 50Hz Data Sheet (Replaces CD.42.U4.22) General TFS4FT

Connector-material

Sealing

Copper-plated steel

Aluminium caps

Copper-plated steel

Rubber plugs

Copper

Rubber plugs

Application

102G

TFS4FT

Code number

R134a SUCTION CONNECTOR

Blue stripe

102G4430

4430

Barcode on white background

DANFOSS COMPRESSORS

8321

Compressor

Yellow background

Application Application

LBP

Evaporating temperature range

°F (°C)

Voltage range

-31 to 23 (-35 to -5)

V/Hz

176 - 242 /50

Motor type

RSIR

Max. ambient temperature

°F (°C)

110 (43)

Comp. cooling at

S O F1 F2

max. ambient temperature

110°F (43°C)

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

S

Design Displacement

cu.in. (cm3)

Oil quantity

fl.oz. (cm3)

6.1 (180)

oz. (g)

14.0 (400)

14.9 (6.8)

4.02"(102)

Motor A

7.4

Cut-in current LST

A

7.4

Resistance, main and start winding (77°F) Ω

A B

-

(29)

D E

19.3/38.1

Approvals

8246

8.90"(226) 6.93"(176)

4.13"(105) 4.21"(107)

LRA (rated after 4 sec.UL984) LST

C

30°

90

° 31.5 28°

watt

4.13"(105)

Motor size

3.78"(96) 4.61"(117)

1.14"

51 20° °

6.18"(157)

57.3 (1690)

lbs. (kg)

2.80"(71)

Weight without electrical equipment

45°

Free gas vol. in compressor housing fl.oz. (cm3)

2.34"(59.5) 2.60" (66)

Maximum refrigerant charge

0.23 (3.86)

Dimensions B

6.65 (169)

Suction connector

location/I.D. in. (mm) C 0.252-0.259 (6.5±0.09)

Process connector

location/I.D. in. (mm) D 0.252-0.259 (6.5±0.09)

Discharge connector

location/I.D. in. (mm) E 0.202-0.205 (5.0+0.12/0.20)

Compressors on a pallet

pcs.

ø0.75"(19)

6.50"(165)

ø0.63"(16)

ø0.14"(3.6) 5.35"(136)

6.81 (173)

2.76"(70)

in. (mm) A

4.00"(101.6)

Height

125 6.70"(170) 7.01"(178) 8.03"(204)

August 2003

122

CD.42.U5.22

CK.40.B7.02

1

August 2003

Capacity (ASHRAE) Comp.\°F Comp.\°C TFS4FT

-30 -34.4 154

Btu/h

-20 -28.9 234

-13 -25 303

-10 -23.3 335

0 -17.8 461

10 -12.2 615

14 -10 685

20 -6.7 800 a2

Capacity (EN 12900/CECOMAF) Comp.\°C Comp.\°F TFS4FT

-34.4 -30 37

-28.9 -20 56

watt

-25 -13 72

-23.3 -10 80

-17.8 0 110

-12.2 10 147

-10 14 164

-13 -25 84

-10 -23.3 87

0 -17.8 100

10 -12.2 114

14 -10 120

-6.7 20 191

Power consumption Comp.\°F Comp.\°C TFS4FT

-30 -34.4 68

-30 -34.4 0.68

-20 -28.9 0.70

8230

d

watt

-20 -28.9 77

20 -6.7 130

Current consumption Comp.\°F Comp.\°C TFS4FT

b

a2

A -13 -25 0.72

-10 -23.3 0.73

0 -17.8 0.76

10 -12.2 0.81

14 -10 0.82

20 -6.7 0.85

10 12

Comp.\°F Comp.\°C TFS4FT

14

Btu/Wh

-30 -34.4 2.27

-20 -28.9 3.06

-13 -25 3.62

-10 -23.3 3.85

0 -17.8 4.63

10 -12.2 5.39

14 -10 5.69

20 -6.7 6.16

M

(pos.1)

COP (EN 12900/CECOMAF) Comp.\°C Comp.\°F TFS4FT

Start winding Thermostat

Main winding

EER (ASHRAE)

11 13

-34.4 -30 0.54

-28.9 -20 0.73

-25 -13 0.87

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Static cooling, 220V 50Hz

Motor protector

W/W -23.3 -10 0.92

-17.8 0 1.11

-12.2 10 1.29

-10 14 1.36

ASHRAE 130°F (54.4°C) 90°F (32°C) 90°F (32°C)

EN 12900/CECOMAF 55°C (131°F) 32°C (90°F) 55°C (131°F)

Fig.

TFS4FT

-6.7 20 1.47

a2

8231

Accessories

b

Devices Star ting relay (Klixon incl.) Protector 3/4"

Texas Instruments

a2

117U4109 a2

MRP209HL-6

7

1

Cover (standard) Cord relief

Cover (alternative) Mounting accessories Bolt joint for one compressor Bolt joint for one compressor Snap-on for one compressor

2

August 2003

b d (pos.1)

117U1023 117U0349

b (pos.2)

117U1022

Ø in. (mm) 5 /8 (16) 3 /4 (19) 5 /8 (16)

L 2

8

3

N

Main winding

11

10 4

13

12

Start winding

5 14

M 6

118-1946 118-1949 118-1947

Motor protector

(pos.2)

CD.42.U5.22

CK.40.B7.02

August 2003

123

TFS4.5FT Tropical Compressor R134a 220V 50Hz Data Sheet (Replaces CG.42.W1.22) General TFS4.5FT

Connector-material

Sealing

Copper-plated steel

Aluminium caps

Copper-plated steel

Rubber plugs

Copper

Rubber plugs

Application

102G

TFS4.5FT

Code number

R134a SUCTION CONNECTOR

Blue stripe

102G4431

4431

Barcode on white background

8431

Compressor

DANFOSS COMPRESSORS

Yellow background

Application

R

LBP

Evaporating temperature range

°F (°C)

Voltage range

TFS4.5FT 220V-50Hz 1PH

-31 to 23 (-35 to -5)

V/Hz

176 - 242 /50

Motor type

RSIR

Max. ambient temperature

°F (°C)

110 (43)

Comp. cooling at max. ambient temperature

110°F (43°C)

S O F1

S F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temp. equal to ambient temperature) = Fan cooling 3.0 m/s necessary

THERMALLY PROTECTED

8431-2

Application

Approval mark

Design cu.in. (cm3)

14.9 (6.8)

4.02"(102)

Motor 9.4

A

9.4

Resistance, main and start winding (77°F) Ω Approvals

UL984/CSA-C22.2

Dimensions in. (mm) A

6.81 (173)

B

6.65 (169)

Suction connector

location/I.D. in. (mm) C 0.252-0.259 (6.5±0.09)

Process connector

location/I.D. in. (mm) D 0.252-0.259 (6.5±0.09)

Discharge connector

location/I.D. in. (mm) E 0.202-0.205 (5.0+0.12/0.20)

Compressors on a pallet

124

A B

ø0.75"(19)

Height

August 2003

pcs.

125

CG.42.W2.22

CK.40.B7.02

(29)

E

13.5/34.3 EN 60335-2-34 with Annex AA

D

4.13"(105) 4.21"(107)

A

Cut-in current LST

8246

8.90"(226) 6.93"(176)

6.50"(165)

ø0.63"(16)

ø0.14"(3.6) 2.76"(70)

LRA (rated after 4 sec.UL984) LST

C

30°

120

° 31.5 28°

watt

4.13"(105)

Motor size

3.78"(96) 4.61"(117)

1.14"

57.3 (1690)

lbs. (kg)

5.35"(136)

Weight without electrical equipment

45°

Free gas vol. in compressor housing fl.oz. (cm3)

2.80"(71)

14.0 (400)

4.00"(101.6)

6.1 (180)

oz. (g)

Maximum refrigerant charge

51 20° °

0.29 (4.63)

fl.oz. (cm3)

6.18"(157)

Oil quantity

2.34"(59.5) 2.60" (66)

Displacement

6.70"(170) 7.01"(178) 8.03"(204)

1

August 2003

Capacity (ASHRAE) Comp.\°F Comp.\°C TFS4.5FT

-30 -34.4 199

-20 -28.9 296

Btu/h -13 -25 379

-10 -23.3 418

0 -17.8 569

10 -12.2 754

14 -10 839

20 -6.7 977 a2

Capacity (EN 12900/CECOMAF) Comp.\°C Comp.\°F TFS4.5FT

-34.4 -30 48

-28.9 -20 71

watt

-25 -13 91

-23.3 -10 100

-17.8 0 136

-12.2 10 180

-10 14 200

-13 -25 107

-10 -23.3 111

0 -17.8 125

10 -12.2 140

14 -10 146

-6.7 20 233

Power consumption Comp.\°F Comp.\°C TFS4.5FT

-30 -34.4 88

-20 -28.9 99

-30 -34.4 0.95

-20 -28.9 0.97

8230

d

watt 20 -6.7 156

Current consumption Comp.\°F Comp.\°C TFS4.5FT

b

a2

A -13 -25 0.99

-10 -23.3 1.00

0 -17.8 1.03

10 -12.2 1.07

14 -10 1.09

20 -6.7 1.12

10 12

Comp.\°F Comp.\°C TFS4.5FT

-30 -34.4 2.27

-13 -25 3.52

-10 -23.3 3.75

0 -17.8 4.55

10 -12.2 5.38

14 -10 5.73

20 -6.7 6.27

M

(pos.1)

-34.4 -30 0.54

14

Btu/Wh -20 -28.9 2.99

COP (EN 12900/CECOMAF) Comp.\°C Comp.\°F TFS4.5FT

Start winding Thermostat

Main winding

EER (ASHRAE)

11 13

-28.9 -20 0.72

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Static cooling, 220V 50Hz

-25 -13 0.84

Motor protector

W/W -23.3 -10 0.90

ASHRAE 130°F (54.4°C) 90°F (32°C) 90°F (32°C)

-17.8 0 1.09

-12.2 10 1.29

-10 14 1.37

-6.7 20 1.50

a2

EN 12900/CECOMAF 55°C (131°F) 32°C (90°F) 55°C (131°F)

8231

Accessories

b

Devices

Fig.

Star ting relay (Klixon incl.) Protector 3/4"

Texas Instruments

a2

TFS4.5FT 117U4103 a2

MRP77HL-6

7

1

Cover (standard) Cord relief

Cover (alternative) Mounting accessories Bolt joint for one compressor Bolt joint for one compressor Snap-on for one compressor

2

August 2003

b d (pos.1)

117U1021 117U0349

b (pos.2)

117U1024

Ø in. (mm) 5 /8 (16) 3 /4 (19) 5 /8 (16)

L 2

8

3

N

Main winding

11

10 4

13

12

Start winding

5 14

M 6

118-1946 118-1949 118-1947

Motor protector

(pos.2)

CG.42.W2.22

CK.40.B7.02

August 2003

125

NL6FT Tropical Compressor R134a 220-240V 50/60Hz Data Sheet (Replaces CD.43.M7.02) General NL6FT

Code number

105G6628

Application Application

LBP

Evaporating temperature range Voltage range

°C

-35 to -10

V/Hz

105G

NL6FT Application

R134a

Blue stripe Approvals

6628

Barcode on white background

DANFOSS COMPRESSORS

Yellow background

8282-4

Compressor

187 - 254 /50 198 - 254 /60 RSIR*)

Motor type Max. ambient temperature Comp. cooling at ambient temp.

43

32°C

S

38°C

S

43°C

S

S O F1 F2

Displacement

cm 3

Oil quantity

cm 3

320

g

400

cm3

2360

kg

10.0

Maximum refrigerant charge Free gas vol. in compressor

6.13

204 170

100 70

Weight without electrical equipment

Motor Motor size

watt

LRA (rated after 4 sec. UL984) LST/HST

155

A A

10.3/7.4

Resistance, main and start winding (25°C)



12.6/12.4

178

D

205

C

EN 60335-2-34, CCIB

191

Suction connector

location/I.D. mm

C

6.2 ±0.09

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

5.0 +0.12/+0.20

254 8248

72

51°

113

126

CD.43.M8.02

CK.40.B7.02

27°

47°

54 78

80 166

pcs.

102.5

B

75.5

197

93.5

A

15°

A B

mm

35°

Dimensions

August 2003

E

25°

Approvals

Compressors on a pallet

ø16

5.9/7.4

Cut-in current LST/HST

Height

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

*) In capillary tube systems where non-equalized pressures may occur at compressor start, or in areas with short power supply drop-outs, a starting capacitor can be used for ensuring a successful start (CSIR).

60.5

Design

°C

119 127

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C NL6FT

-35 60

-30 84

-25 115

watt -23.3 127

-20 152

-15 198

-10 253

HST c

Capacity (ASHRAE) Comp.\°C NL6FT

-35 74

watt

-30 104

-25 141

-23.3 156

-20 188

-15 244

-10 311 b

Power consumption Comp.\°C NL6FT

-35 93

watt

-30 107

-25 123

-23.3 130

-20 142

-15 163

8219

-10 184

a2 d

Current consumption Comp.\°C NL6FT

-35 0.77

-30 0.80

A -25 0.84

-23.3 0.85

-20 0.89

-15 0.96

-10 1.04

c 11

10

COP (EN 12900/CECOMAF) Comp.\°C NL6FT

-35 0.65

W/W

-30 0.79

-25 0.93

-23.3 0.98

-20 1.07

-15 1.22

-30 0.97

-25 1.15

-23.3 1.21

-20 1.32

-15 1.50

COP (ASHRAE) Comp.\°C NL6FT

-35 0.80

-10 1.37

12

13 14

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Static cooling, 220V 50Hz, PTC consumption incl.

EN 12900/CECOMAF 55°C 32°C 55°C

-10 1.69

Main winding

ASHRAE 55°C 32°C 32°C

Winding protector Start winding

LST g

b 8217

a1

Accessories

d

Devices

Fig.

NL6FT

a1

103N0011 103N0018

Starting relay

a2

117U6000 103N2010

PTC starting device

6.3 mm spades 4.8 mm spades

Cover

b

Starting capacitor 80 µF

c

117U5015

Cord relief

d

103N1010

Protection screen for PTC

g

103N0476

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

Main winding a1 Start winding N

N

118-1917 118-1918 118-1919

C

L

Winding protector

CD.43.M8.02

CK.40.B7.02

August 2003

127

NL6.1FT Tropical Compressor R134a 220-240V 50Hz Data Sheet General NL6.1FT

Code number

105G6620

Application Evaporating temperature range Voltage range

°C V/Hz

LBP

Barcode on white background

-35 to -10

Yellow background

6620

DANFOSS COMPRESSORS

187 - 254 /50 RSIR*)

Motor type Max. ambient temperature Comp. cooling at ambient temp.

°C

43

32°C

S

38°C

S

43°C

S

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

*) In capillary tube systems where non-equalized pressures may occur at compressor start, or in areas with short power supply drop-outs, a starting capacitor can be used for ensuring a successful start (CSIR).

Displacement Oil quantity

cm3

6.13

3

320

cm

Maximum refrigerant charge Free gas vol. in compressor

g

400

cm3

2270

kg

9.3

204 170

100 70

Weight without electrical equipment

Motor Motor size

watt

131

LRA (rated after 4 sec. UL984) LST/HST

A

5.4/7.4

Cut-in current LST/HST

A

10.2/7.4

Resistance, main and start winding (25°C) Ω

15.2/12.3

ø16 178

D

205

E

EN 60335-2-34

B

181

Suction connector

location/I.D. mm

C

6.2 ±0.09

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

5.0 +0.12/+0.20

25°

A B

102.5

188

75.5

A

15°

mm

35°

Dimensions

C

93.5

Approvals

Height

R134a

Blue stripe Approvals

Application

Design

105G

NL6.1FT Application

8282-8

Compressor

254 8248

72

51°

113

August 2003

128

CJ.43.B1.02

CK.40.B7.02

27°

47°

54 78

80 60.5

pcs.

166

Compressors on a pallet

119 127

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C NL6.1FT

-35 60

-30 84

-25 115

watt -23.3 127

-20 152

-15 198

-10 253

HST c

Capacity (ASHRAE) Comp.\°C NL6.1FT

-35 74

-30 104

watt -25 141

-23.3 156

-20 188

-15 244

-10 311 b

Power consumption Comp.\°C NL6.1FT

-35

-30

watt -25 123

-23.3 130

-20

-15

8219

-10

a2 d

Current consumption Comp.\°C NL6.1FT

-35

-30

A -25 0.84

-23.3 0.85

-20

-15

-10 c 11

10

COP (EN 12900/CECOMAF) Comp.\°C NL6.1FT

-35

-30

W/W

-25 0.93

-23.3 0.98

-20

-25 1.15

-23.3 1.21

-20

-15

-35

12

13 14

COP (ASHRAE) Comp.\°C NL6.1FT

-10

W/W -30

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Static cooling, 220V 50Hz, PTC consumption incl. preliminary data

EN 12900/CECOMAF 55°C 32°C 55°C

-15

-10

Main winding

ASHRAE 55°C 32°C 32°C

Winding protector Start winding

LST g

b 8217

a1

Accessories Devices

Fig.

NL6.1FT

a1

103N0011 103N0018

Star ting relay

a2

117U6017 103N2010

PTC star ting device 6.3 mm spades 4.8 mm spades

Cover

b

Star ting capacitor 80 µF

c

117U5015

Cord relief

d

103N1010

Protection screen for PTC

g

103N0476

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

d Main winding a1 Start winding N

N

118-1917 118-1918 118-1919

C

L

Winding protector

CJ.43.B1.02

CK.40.B7.02

August 2003

129

NL7FT Tropical Compressor R134a 220-240V 50Hz Data Sheet (Replaces CG.43.L1.02) General NL7FT

Code number

105G6728

Code number compressor with oil cooler

105G6738

105G

NL7FT Application

R134a

Blue stripe Approvals

Application

LBP

Evaporating temperature range Voltage range

°C

187 - 254 /50 RSIR*)

Max. ambient temperature Comp. cooling at ambient temp.

°C

43

32°C

S

38°C

S

43°C

O/F1

S O F1 F2

cm3

Oil quantity

cm3

320

g

400

cm3

2360

kg

10.0

Maximum refrigerant charge Free gas vol. in compressor

7.27 204 170

100 70

Weight without electrical equipment

Motor Motor size

watt

LRA (rated after 4 sec. UL984) LST/HST

175

A

ø16

6.8/8.1

Cut-in current LST/HST

A

11.4/8.1

Resistance, main and start winding (25°C)



10.7/13.0

178 205

D

EN 60335-2-34, CCIB

location/I.D. mm

C

6.2 ±0.09

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

5.0 +0.12/+0.20

Oil cooler

location/I.D. mm

F

5.0 +0.12/+0.20 80

40 102.5 75.5

93.5

51°

113

130

CG.43.L2.02

CK.40.B7.02

F 8249

72

pcs.

254

27°

47°

40 54 78

Suction connector

60.5

197 191

166

A B

15°

mm

35°

A B

Dimensions

August 2001

E C

25°

Approvals

Compressors on a pallet

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

*) In capillary tube systems where non-equalized pressures may occur at compressor start, or in areas with short power supply drop-outs, a starting capacitor can be used for ensuring a successful start (CSIR).

Displacement

Height

DANFOSS COMPRESSORS

Yellow background

-35 to -10

V/Hz

Motor type

Design

6728

Barcode on white background

Application

8282-2

Compressor

119 127

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C NL7FT

-35 71

-30 100

-25 136

watt -23.3 150

-20 181

-15 235

-10 299

HST c

Capacity (ASHRAE) Comp.\°C NL7FT

-35 87

watt

-30 123

-25 168

-23.3 185

-20 222

-15 289

-10 369 b

Power consumption Comp.\°C NL7FT

-35 108

watt

-30 124

-25 145

-23.3 152

-20 168

-15 194

8219

-10 220

a2 d

Current consumption Comp.\°C NL7FT

-35 0.86

-30 0.88

A -25 0.94

-23.3 0.96

-20 1.01

-15 1.11

-10 1.21

c 11

10

COP (EN 12900/CECOMAF) Comp.\°C NL7FT

-35 0.66

W/W

-30 0.81

-25 0.94

-23.3 0.99

-20 1.07

-15 1.21

-30 0.99

-25 1.16

-23.3 1.21

-20 1.32

-15 1.49

COP (ASHRAE) Comp.\°C NL7FT

-35 0.81

-10 1.36

12

13 14

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Static cooling, 220V 50Hz, PTC consumption incl.

EN 12900/CECOMAF 55°C 32°C 55°C

-10 1.68

Main winding

ASHRAE 55°C 32°C 32°C

Winding protector Start winding

LST g

b 8217

a1

Accessories

d

Devices

Fig.

NL7FT

a1

103N0011 103N0018

Starting relay

a2

117U6001 103N2010

PTC starting device

6.3 mm spades 4.8 mm spades

Cover

b

Starting capacitor 80 µF

c

117U5015

Cord relief

d

103N1010

Protection screen for PTC

g

103N0476

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

Main winding a1 Start winding N

N

118-1917 118-1918 118-1919

C

L

Winding protector

CG.43.L2.02

CK.40.B7.02

August 2001

131

NL9FT Tropical Compressor R134a 220-240V 50Hz Data Sheet (Replaces CD.43.N3.02) General NL9FT

Code number

105G6828

Code number compressor with oil cooler

105G6838

105G

NL9FT Application

R134a

Blue stripe Approvals

Application Application

LBP

Evaporating temperature range Voltage range

°C

6828

Barcode on white background

DANFOSS COMPRESSORS

Yellow background

8282

Compressor

-35 to -10

V/Hz

187 - 254 /50 RSIR*)

Motor type Max. ambient temperature

°C

Comp. cooling at ambient temp.

S O F1

43

32°C

S

38°C

O/F1

43°C

O/F1

F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

*) In capillary tube systems where non-equalized pressures may occur at compressor start, or in areas with short power supply drop-outs, a starting capacitor can be used for ensuring a successful start (CSIR).

Design Displacement

cm 3

Oil quantity

cm 3

320

g

400

cm3

2360

kg

10.0

Maximum refrigerant charge Free gas vol. in compressor

204 170

100 70

Weight without electrical equipment

8.35

Motor Motor size

watt

215

LRA (rated after 4 sec. UL984) LST/HST

A

Cut-in current LST/HST

A

12.8/8.2

Resistance, main and start winding (25°C) Ω

8.9/12.0

D

C

C

6.2 ±0.09

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

5.0 +0.12/+0.20

Oil cooler

location/I.D. mm

F

5.0 +0.12/+0.20 80

40 102.5 75.5

93.5

51°

113

132

CD.43.N4.02

CK.40.B7.02

F 8249

72

pcs.

254

27°

47°

40 54 78

location/I.D. mm

60.5

197 191

166

A B

15°

mm

35°

A B

Suction connector

August 2003

E

EN 60335-2-34, CCIB

Dimensions

Compressors on a pallet

178 205

25°

Approvals

Height

ø16

8.1/8.2

119 127

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C NL9FT

-35 87

-30 120

-25 162

watt -23.3 178

-20 213

-15 275

-10 350

HST c

Capacity (ASHRAE) Comp.\°C NL9FT

-35 107

watt

-30 148

-25 199

-23.3 219

-20 262

-15 339

-10 432 b

Power consumption Comp.\°C NL9FT

-35 127

watt

-30 146

-25 169

-23.3 178

-20 195

-15 223

8219

-10 252

a2 d

Current consumption Comp.\°C NL9FT

-35 1.18

-30 1.22

A -25 1.28

-23.3 1.30

-20 1.36

-15 1.45

-10 1.55

c 11

10

COP (EN 12900/CECOMAF) Comp.\°C NL9FT

-35 0.69

W/W

-30 0.82

-25 0.95

-23.3 1.00

-20 1.09

-15 1.24

-30 1.01

-25 1.17

-23.3 1.23

-20 1.34

-15 1.52

COP (ASHRAE) Comp.\°C NL9FT

-35 0.84

-10 1.39

12

13 14

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Static cooling, 220V 50Hz, PTC consumption incl.

EN 12900/CECOMAF 55°C 32°C 55°C

-10 1.72

Main winding

ASHRAE 55°C 32°C 32°C

Winding protector Start winding

LST g

b 8217

a1

Accessories

d

Devices

Fig.

NL9FT

a1

103N0011 103N0018

Starting relay

a2

117U6015 103N2010

PTC starting device

6.3 mm spades 4.8 mm spades

Cover

b

Starting capacitor 80 µF

c

117U5015

Cord relief

d

103N1010

Protection screen for PTC

g

103N0476

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

Main winding a1 Start winding N

N

118-1917 118-1918 118-1919

C

L

Winding protector

CD.43.N4.02

CK.40.B7.02

August 2003

133

NL10FT Tropical Compressor R134a 220-240V 50Hz Data Sheet (Replaces CG.43.I1.02) General NL10FT

Code number

105G6829

Code number

105G6837*

Code number compressor with oil cooler

105G6839 * Performance data established on 8.2 mm suction line. Restrictions due to 6.2 mm suction line can affect system performance.

105G

NL10FT Application

R134a

Blue stripe Approvals

6829

Barcode on white background

DANFOSS COMPRESSORS

Yellow background

8282-3

Compressor

Application Application

LBP

Evaporating temperature range Voltage range

°C

-35 to -10

V/Hz

RSIR*)

Motor type Max. ambient temperature Comp. cooling at ambient temp.

°C

43

32°C

S

38°C

O/F1

43°C

O/F1

F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

*) In capillary tube systems where non-equalized pressures may occur at compressor start, or in areas with short power supply drop-outs, a starting capacitor can be used for ensuring a successful start (CSIR).

cm3

10.10

Oil quantity

cm3

320

Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment

g

400

cm3

2360

kg

10.5

204 170

100 70

Displacement

ø16

Motor 235

A

13.6/10.4

Resistance, main and start winding (25°C)



8.2/14.7 EN 60335-2-34, CCIB

105G6829/39 mm

105G6837

A

203

B

197

254

Suction connector

location/I.D. mm

C 8.2 ±0.09

Process connector

location/I.D. mm

D 6.2 ±0.09

6.2 ±0.09

Discharge connector

location/I.D. mm

E 6.2 ±0.09

5.0 +0.12/+0.20

Oil cooler

location/I.D. mm

F 6.2 ±0.09

Compressors on a pallet

pcs.

80

8249

51°

113

August 2001

134

F

6.2 ±0.09

60.5

Height

A B

15°

Dimensions

C 35°

Approvals

E

40 102.5 75.5

Cut-in current LST/HST

D

25°

9.2/10.4

93.5

A

166

watt

LRA (rated after 4 sec. UL984) LST/HST

72

Motor size

178 205

CG.43.I2.02

CK.40.B7.02

27°

47°

40 54 78

Design

S O F1

187 - 254 /50

119 127

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C NL10FT

-35 113

-30 158

-25 213

watt -23.3 235

-20 281

-15 361

-10 455

HST c

Capacity (ASHRAE) Comp.\°C NL10FT

-35 138

watt

-30 194

-25 262

-23.3 289

-20 345

-15 445

-10 561 b

Power consumption Comp.\°C NL10FT

-35 159

watt

-30 184

-25 217

-23.3 229

-20 254

-15 292

8219

-10 327

a2 d

Current consumption Comp.\°C NL10FT

-35 1.33

-30 1.39

A -25 1.48

-23.3 1.52

-20 1.60

-15 1.74

-10 1.88

c 11

10

COP (EN 12900/CECOMAF) Comp.\°C NL10FT

-35 0.71

W/W

-30 0.85

-25 0.98

-23.3 1.02

-20 1.10

-15 1.24

-30 1.05

-25 1.21

-23.3 1.26

-20 1.36

-15 1.52

COP (ASHRAE) Comp.\°C NL10FT

-35 0.87

-10 1.39

12

13 14

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Static cooling, 220V 50Hz, PTC consumption incl.

EN 12900/CECOMAF 55°C 32°C 55°C

-10 1.71

Main winding

ASHRAE 55°C 32°C 32°C

Winding protector Start winding

LST g

b 8217

a1

Accessories

d

Devices

Fig.

NL10FT

a1

103N0011 103N0018

Starting relay

a2

117U6002 103N2010

PTC starting device

6.3 mm spades 4.8 mm spades

Cover

b

Starting capacitor 80 µF

c

117U5015

Cord relief

d

103N1010

Protection screen for PTC

g

103N0476

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

Main winding a1 Start winding N

N

118-1917 118-1918 118-1919

C

L

Winding protector

CG.43.I2.02

CK.40.B7.02

August 2001

135

SC12FT Tropical Compressor R134a 220-240V 50/60Hz Data Sheet (Replaces CG.44.C2.02) General SC12FT

Code number

104G8205

Code number compressor with oil cooler

104G8215

104G

SC12FT Application

R134a

Blue stripe Approvals

8205

Barcode on white background

Application Application

LBP

Evaporating temperature range

°C

Voltage range

LBP: 187 - 254 /50 LBP: 198 - 254 /60

Motor type

S O F1

RSIR/CSIR °C

Comp. cooling at ambient temp.

DANFOSS COMPRESSORS

Yellow background

-35 to -5

V/Hz

Max. ambient temperature

8418

Compressor

43

32°C

LBP: O/F1

38°C

LBP: O/F1

43°C

LBP: F2*)

F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

*) O/F 1 possible at 220V nominal (187-242V)

Design Displacement

cm3

Oil quantity

cm3 550 (500 on comp. with oil cooler)

Maximum refrigerant charge Free gas vol. in compressor

g

1300

cm3

1510

kg

12.6

204 178 170

ø16

ø19 ø9.7

Motor Motor size

watt

70 150

127 101.6 35

Weight without electrical equipment

12.87

315

LRA (rated after 4 sec. UL984) LST/HST

A

12.4/12.6

Cut-in current LST/HST

A

17.2/12.6

Resistance, main and start winding (25°C)



6.7/11.8

Approvals

127 165 186 218

D

C

EN 60335-2-34

E

Dimensions

B1

183

B2

100

location/I.D. mm

C

8.2 ±0.09

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

6.2 ±0.09

Oil cooler

location/I.D. mm

F

6.2 ±0.09

Suction connector

Compressors on a pallet

pcs.

30

136

B2

255

F

37°

37°

80 107

August 2003

15 53

203

63

B

B A

B1

55 63

209

3

A

55

mm

151

Height

CG.44.C3.02

CK.40.B7.02

107 115

8264

1

August 2003

Capacity (EN 12900/CECOMAF) Evap. temp in °C SC12FT, 50Hz SC12FT, 60Hz

-35 103 125

-30 163 192

-25 233 272

watt -23.3 259 302

-20 314 366

-15 408 477

-10 517 608

-5 645 761

Capacity (ASHRAE) Evap. temp in °C SC12FT, 50Hz SC12FT, 60Hz

-35 126 153

HST c

watt -30 201 237

-25 287 336

-23.3 320 373

-20 387 452

-15 503 589

-10 639 751

-5 798 942

b 8222

Power consumption Evap. temp in °C SC12FT, 50Hz SC12FT, 60Hz

-35 184 193

watt -30 226 245

-25 265 298

-23.3 278 316

-20 303 351

-15 341 405

-10 380 458

-5 422 511

Current consumption Evap. temp in °C SC12FT, 50Hz SC12FT, 60Hz

-35 1.84 1.58

a2 d

A -30 1.93 1.75

-25 2.04 1.92

-23.3 2.08 1.98

-20 2.17 2.10

-15 2.30 2.30

-10 2.45 2.50

-5 2.61 2.71

c 11

10

COP (EN 12900/CECOMAF) Evap. temp in °C SC12FT, 50Hz SC12FT, 60Hz

W/W

-35 0.56 0.64

-30 0.72 0.78

-25 0.88 0.91

-23.3 0.93 0.96

-20 1.03 1.04

-15 1.20 1.18

-10 1.36 1.33

-35 0.69 0.79

-30 0.89 0.97

-25 1.08 1.13

-23.3 1.15 1.18

-20 1.28 1.29

-15 1.48 1.46

-10 1.68 1.64

-5 1.53 1.49

COP (ASHRAE) Evap. temp in °C SC12FT, 50Hz SC12FT, 60Hz

12

13 14

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature 50Hz: Fan cooling F2, 220V 60Hz: Fan cooling F2, 220V

EN 12900/CECOMAF 55°C 32°C 55°C

-5 1.89 1.84

ASHRAE 55°C 32°C 32°C

Start winding Main winding Winding protector

LST

b 8221

a1 d

Accessories

Main winding

Devices PTC starting device

Fig. 6.3 mm spades

SC12FT

a1

103N0002

Starting relay

a2

117U6003

Cover

b

103N2009

Starting capacitor 80 µF

c

117U5017

Cord relief

d

103N1004

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

118-1917 118-1918 118-1919

CG.44.C3.02

CK.40.B7.02

a1

Start winding

N

N

C

L

Winding protector

August 2003

137

SC15FT Tropical Compressor R134a 220-240V 50/60Hz Data Sheet (Replaces CD.44.D1.02) General SC15FT

Code number

104G8505

Code number compressor with oil cooler

104G8515

104G

SC15FT Application

R134a

Blue stripe Approvals

8505

Barcode on white background

Application Application

LBP

Evaporating temperature range

°C

Voltage range

LBP: 187 - 254 /50 LBP: 198 - 254 /60

Motor type

S O F1

RSIR/CSIR °C

Comp. cooling at ambient temp.

DANFOSS COMPRESSORS

Yellow background

-35 to -5

V/Hz

Max. ambient temperature

8418-2

Compressor

43

32°C

LBP: O/F1

38°C

LBP: O/F1

43°C

LBP: F2*)

F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

*) O/F 1 possible at 220V nominal (187-242V)

Design Displacement

cm 3

Oil quantity

cm 3 550 (500 on comp. with oil cooler)

Maximum refrigerant charge Free gas vol. in compressor

g

1300

cm3

1410

kg

13.1

204 178 170

ø16

ø19 ø9.7

Motor Motor size

watt

70 150

127 101.6 35

Weight without electrical equipment

15.28

385

LRA (rated after 4 sec. UL984) LST/HST

A

15.5/14.8

Cut-in current LST/HST

A

19.9/14.8

Resistance, main and start winding (25°C)



5.0/13.7

Approvals

127 165 186 218

D

C

EN 60335-2-34

E

Dimensions

B1

183

B2

100

location/I.D. mm

C

10.2 ±0.09

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

6.2 ±0.09

Oil cooler

location/I.D. mm

F

6.2 ±0.09

Suction connector

Compressors on a pallet

pcs.

30

138

B2

255

F

37°

37°

80 107

August 2003

15 53

203

63

B

B A

B1

55 63

209

3

A

55

mm

151

Height

CG.44.D2.02

CK.40.B7.02

107 115

8264

1

August 2003

Capacity (EN 12900/CECOMAF) Evap. temp in °C SC15FT, 50Hz SC15FT, 60Hz

-35 126 154

-30 197 235

-25 280 330

watt -23.3 311 365

-20 376 441

-15 489 571

-10 620 724

-5 772 904

Capacity (ASHRAE) Evap. temp in °C SC15FT, 50Hz SC15FT, 60Hz

-35 155 189

HST c

watt -30 243 290

-25 345 407

-23.3 384 451

-20 465 544

-15 604 705

-10 766 895

-5 955 1118

b 8222

Power consumption Evap. temp in °C SC15FT, 50Hz SC15FT, 60Hz

-35 223 231

watt -30 267 294

-25 311 356

-23.3 326 377

-20 356 418

-15 403 478

-10 451 537

-5 500 596

Current consumption Evap. temp in °C SC15FT, 50Hz SC15FT, 60Hz

-35 2.22 1.87

a2 d

A -30 2.31 2.07

-25 2.42 2.27

-23.3 2.46 2.34

-20 2.54 2.48

-15 2.69 2.70

-10 2.86 2.93

-5 3.05 3.16

c 11

10

COP (EN 12900/CECOMAF) Evap. temp in °C SC15FT, 50Hz SC15FT, 60Hz

W/W

-35 0.56 0.66

-30 0.74 0.80

-25 0.90 0.92

-23.3 0.95 0.97

-20 1.06 1.05

-15 1.21 1.19

-10 1.38 1.35

-35 0.70 0.82

-30 0.91 0.98

-25 1.11 1.14

-23.3 1.18 1.19

-20 1.30 1.30

-15 1.50 1.48

-10 1.70 1.67

-5 1.54 1.52

COP (ASHRAE) Evap. temp in °C SC15FT, 50Hz SC15FT, 60Hz

12

13 14

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature 50Hz: Fan cooling F2, 220V 60Hz: Fan cooling F2, 220V

EN 12900/CECOMAF 55°C 32°C 55°C

-5 1.91 1.88

ASHRAE 55°C 32°C 32°C

Start winding Main winding Winding protector

LST

b 8221

a1 d

Accessories

Main winding

Devices

Fig.

a1

Start winding

SC15FT N

PTC starting device

a1

103N0002

Starting relay

6.3 mm spades

a2

117U6005

Cover

b

103N2009

Starting capacitor 80 µF

c

117U5017

Cord relief

d

103N1004

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

118-1917 118-1918 118-1919

CG.44.D2.02

CK.40.B7.02

N

C

L

Winding protector

August 2003

139

SC18FTX Tropical Compressor R134a 220-240V 50/60Hz Data Sheet (Replaces CG.44.E1.02) General SC18FTX

Code number

104G8805

104G

SC18FTX Application

R134a

Blue stripe Approvals

Application Application Evaporating temperature range Voltage range

°C V/Hz

LBP

Barcode on white background

-35 to -5

Yellow background

8805

8418-3

Compressor

DANFOSS COMPRESSORS

LBP: 187 - 254 /50 LBP: 198 - 254 /60

Motor type

CSIR

Max. ambient temperature

°C

Comp. cooling at ambient temp.

S O F1

43

32°C

LBP: F2

38°C

LBP: F2

43°C

LBP: F2

cm3

17.69

F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

Design 550

g

1300

cm3

1460

kg

13.7

cm

Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment

Motor Motor size

watt

495

LRA (rated after 4 sec. UL984) HST

A

18.6

Cut-in current HST

A

18.6

Resistance, main and start winding (25°C)



3.7/14.1

Approvals

204 178 170

ø16

ø19 ø9.7

70 150

Oil quantity

3

127 101.6 35

Displacement

127 165 186 218

D

EN 60335-2-34

C E

Dimensions

B1

193

B2

110

Suction connector

location/I.D. mm

C

10.2 ±0.09

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

6.2 ±0.09

pcs.

80

B2

255

55

Compressors on a pallet

B A

B1

63

219 213

37°

37°

107

August 2003

140

CG.44.E2.02

CK.40.B7.02

107 115

55 63

A B

3

mm

151

Height

8257

1

August 2003

Capacity (EN 12900/CECOMAF) Evap. temp in °C SC18FTX, 50Hz SC18FTX, 60Hz

-35 144 187

-30 229 280

-25 325 390

watt -23.3 361 432

-20 437 520

-15 567 675

-10 719 857

-5 896 1071

Capacity (ASHRAE) Evap. temp in °C SC18FTX, 50Hz SC18FTX, 60Hz

-35 178 230

c

watt -30 282 345

-25 401 481

-23.3 445 532

-20 539 642

-15 700 834

-10 889 1060

-5 1108 1326

b 8222

Power consumption Evap. temp in °C SC18FTX, 50Hz SC18FTX, 60Hz

-35 257 274

watt -30 313 348

-25 365 420

-23.3 383 444

-20 416 489

-15 466 557

-10 517 622

-5 571 686

Current consumption Evap. temp in °C SC18FTX, 50Hz SC18FTX, 60Hz

-35 2.52 2.05

a2 d

A -30 2.69 2.36

-25 2.87 2.66

-23.3 2.94 2.77

-20 3.07 2.97

-15 3.27 3.28

-10 3.49 3.59

-5 3.72 3.90

c 11

10

COP (EN 12900/CECOMAF) Evap. temp in °C SC18FTX, 50Hz SC18FTX, 60Hz

W/W

-35 0.56 0.68

-30 0.73 0.80

-25 0.89 0.93

-23.3 0.94 0.97

-20 1.05 1.06

-15 1.22 1.21

-10 1.39 1.38

-35 0.69 0.84

-30 0.90 0.99

-25 1.10 1.15

-23.3 1.16 1.20

-20 1.30 1.31

-15 1.50 1.50

-10 1.72 1.70

-5 1.57 1.56

COP (ASHRAE) Evap. temp in °C SC18FTX, 50Hz SC18FTX, 60Hz

12

13 14

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature 50Hz: Fan cooling F2, 220V 60Hz: Fan cooling F2, 220V

EN 12900/CECOMAF 55°C 32°C 55°C

-5 1.94 1.93

Start winding Main winding Winding protector

ASHRAE 55°C 32°C 32°C

Accessories Devices

Fig.

SC18FTX

Starting relay

a2

117U6019

Cover

b

103N2009

Starting capacitor 80 µF

c

117U5017

Cord relief

d

103N1004

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

118-1917 118-1918 118-1919

CG.44.E2.02

CK.40.B7.02

August 2003

141

SC21FTX Tropical Compressor R134a 220-240V 50Hz Data Sheet (Replaces CG.44.F1.02) General SC21FTX

Code number

104G8105

104G

SC21FTX Application

R134a

Blue stripe Approvals

Application Application Evaporating temperature range Voltage range

°C V/Hz

LBP

Barcode on white background

-35 to -5

Yellow background

8105

8418-4

Compressor

DANFOSS COMPRESSORS

187 - 254 /50

Motor type

CSIR

Max. ambient temperature

°C

43

32°C

F2

38°C

F2

43°C

F2

Displacement

cm3

20.95

Oil quantity

cm3

Comp. cooling at ambient temp.

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

Design

Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment

550

g

1300

cm3

1460

kg

13.5

204 178 170

ø16

ø19 ø9.7

watt

495

LRA (rated after 4 sec. UL984) HST

A

18.6

Cut-in current HST

A

70 150

Motor size

127 101.6 35

Motor

18.6

Resistance, main and start winding (25°C) Ω

3.7/14.1

Approvals

EN 60335-2-34

127 165 186 218

D

C

Dimensions

E A

219

B

213

B1

193

B2

110

Suction connector

location/I.D. mm

C

10.2 ±0.09

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

6.2 ±0.09

pcs.

B2

255

80 55

63

151

Compressors on a pallet

B A

B1

37°

37°

107

August 2002

142

CG.44.F2.02

CK.40.B7.02

107 115

55 63

mm

3

Height

8258

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C SC21FTX

-35 192

-30 296

-25 415

watt -23.3 460

-20 553

-15 713

-10 901

-5 1119 c

Capacity (ASHRAE) Comp.\°C SC21FTX

-35 237

-30 365

watt -25 512

-23.3 567

-20 682

-15 881

-10 1114

-5 1385 b 8222

Power consumption Comp.\°C SC21FTX

-35 296

-30 364

watt -25 428

-23.3 449

-20 490

-15 551

-10 613

-5 679

a2 d

Current consumption Comp.\°C SC21FTX

-35 2.66

-30 2.88

A -25 3.12

-23.3 3.20

-20 3.37

-15 3.64

-10 3.92

-5 4.22

c 11

10

COP (EN 12900/CECOMAF) Comp.\°C SC21FTX

-35 0.65

W/W

-30 0.81

-25 0.97

-23.3 1.02

-20 1.13

-15 1.30

-10 1.47

-30 1.00

-25 1.20

-23.3 1.26

-20 1.39

-15 1.60

-10 1.82

COP (ASHRAE) Comp.\°C SC21FTX

-35 0.80

-5 1.65

12

13 14

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Fan cooling F2, 220V 50Hz

EN 12900/CECOMAF 55°C 32°C 55°C

-5 2.04

Start winding Main winding Winding protector

ASHRAE 55°C 32°C 32°C

Accessories Devices

Fig.

SC21FTX

Starting relay

a2

117U6019

Cover

b

103N2009

Starting capacitor 80 µF

c

117U5017

Cord relief

d

103N1004

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

118-1917 118-1918 118-1919

CG.44.F2.02

CK.40.B7.02

August 2002

143

SC21FTX Tropical Compressor R134a 208-230V 60Hz Data Sheet General SC21FTX

Code number

104G8106

104G

SC21FTX Application

R134a

Blue stripe Approvals

Application Application Evaporating temperature range Voltage range

°C V/Hz

LBP

Barcode on white background

-35 to -5

Yellow background

8106

8418-5

Compressor

DANFOSS COMPRESSORS

187 - 254 /60

Motor type

CSR

Max. ambient temperature

°C

43

32°C

F2

38°C

F2

43°C

F2

Displacement

cm3

20.95

Oil quantity

cm3

Comp. cooling at ambient temp.

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

Design

Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment

550

g

1300

cm3

1460

kg

14.0

204 178 170

ø16

ø19 ø9.7

watt

590

LRA (rated after 4 sec. UL984) HST

A

23.4

Cut-in current HST

A

70 150

Motor size

127 101.6 35

Motor

23.4

Resistance, main and start winding (25°C) Ω

3.4/14.4

Approvals

EN 60335-2-34

127 165 186 218

D

C

Dimensions

E A

219

B

213

B1

193

B2

110

Suction connector

location/I.D. mm

C

10.2 ±0.09

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

6.2 ±0.09

pcs.

B2

255

80 55

63

151

Compressors on a pallet

B A

B1

37°

37°

107

August 2003

144

CG.44.K1.02

CK.40.B7.02

107 115

55 63

mm

3

Height

8258

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C SC21FTX

-35 240

-30 345

-25 470

watt -23.3 518

-20 620

-15 800

-10 1012

Capacity (ASHRAE) Comp.\°C SC21FTX

-35 296

-30 425

-5 1262

a3 a2

watt -25 580

-23.3 639

-20 766

-15 988

-10 1251

e

-5 156 1

c 8227

Power consumption Comp.\°C SC21FTX

-35 342

-30 409

watt -25 475

-23.3 499

-20 545

-15 62 1

-10 707

-5 805

-25 2.25

-23.3 2.36

-20 2.58

-15 2.93

-10 3.30

-5 3.69

Current consumption Comp.\°C SC21FTX

-35 1.66

-30 1.95

COP (EN 12900/CECOMAF) Comp.\°C SC21FTX

-35 0.70

-30 0.84

W/W

-25 0.99

-23.3 1.04

-20 1.14

-15 1.29

-10 1.43

COP (ASHRAE) Comp.\°C SC21FTX

-35 0.87

d

A

-5 1.57

b e

Start winding 5

2

4

1

a2

Main winding Winding protector 1

1

2 N L

2 N L

Bleeder resistance

c

a3

W/W -30 1.04

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Fan cooling F2, 220V 60Hz

-25 1.22

-23.3 1.28

-20 1.40

EN 12900/CECOMAF 55°C 32°C 55°C

-15 1.59

-10 1.77

-5 1.94

M

Thermostat

Fan

ASHRAE 55°C 32°C 32°C

Accessories Devices

Fig.

SC21FTX

a3

117-7038 (470 mm cable length) 117-7039 (550 mm cable length) 117-7043 (1000 mm cable length) 103N2008

Star ting device

Cover

b

Star ting relay

a2

Star ting capacitor

c

Run capacitor

e

Cord relief

d

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

Components of star ting device 103N1004 118-1917 118-1918 118-1919

CG.44.K1.02

CK.40.B7.02

August 2003

145

NLE9FT Energy-optimized Tropical Compressor R134a 220-240V 50Hz Data Sheet General NLE9FT

Code number

105G6816

105G

NLE9FT Application

R134a

Blue stripe Approvals

Application Application Evaporating temperature range Voltage range

°C V/Hz

LBP

Barcode on white background

-35 to -10

Yellow background

6816

DANFOSS COMPRESSORS

8430-2

Compressor

187 - 254 /50

Motor type

RSIR

Max. ambient temperature Comp. cooling at ambient temp.

°C

43

32°C

S

38°C

S

43°C

S

Displacement

cm3

8.35

Oil quantity

cm3

320

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

Design

Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment

g

400

cm3

2360

kg

10.0

watt

234

204 170

Motor size LRA (rated after 4 sec. UL984) LST

A

8.4

Cut-in current LST

A

13.1

Resistance, main and start winding (25°C) Ω

9.0/12.0

205

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

5.0 +0.12/+0.20

102.5

6.2 ±0.09 254

8248

CH.43.T1.02

CK.40.B7.02

27°

47°

54 78

51°

72

166

60.5

80

113

146

75.5

C

pcs.

203 93.5

197

location/I.D. mm

15°

B Suction connector

35°

A

July 2001

E C

A B

mm

Compressors on a pallet

D

EN 60335-2-34 pending

Dimensions Height

ø16 178

25°

Approvals

100 70

Motor

119 127

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C NLE9FT

-35

-30

-25 180

watt -23.3 197

-20

-15

-10

g

Capacity (ASHRAE) Comp.\°C NLE9FT

-35

watt

-30

-25 224

-23.3 245

-20

-15

-25 163

-23.3 173

-20

-25 1.20

-23.3 1.25

-20

-15

-10

8217

Power consumption Comp.\°C NLE9FT

-35

watt

-30

-15

-35

-30

d

-35

-35

-10

N

W/W

-30

-25 1.10

-23.3 1.14

-20

-15

-30

-25 1.37

-23.3 1.42

-20

-15

COP (ASHRAE) Comp.\°C NLE9FT

Main winding a1 Start winding

A

COP (EN 12900/CECOMAF) Comp.\°C NLE9FT

a1

-10

Current consumption Comp.\°C NLE9FT

b

-10

N

C

L

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Static cooling, 220V 50Hz, PTC consumption incl., preliminary data

EN 12900/CECOMAF 55°C 32°C 55°C

-10

Winding protector

ASHRAE 55°C 32°C 32°C

Accessories Devices PTC starting device

6.3 mm spades 4.8 mm spades

Fig.

NLE9FT

a1

103N0011 103N0018

Cover

b

103N2010

Cord relief

d

103N1010

Protection screen for PTC

g

103N0476

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

118-1917 118-1918 118-1919

CH.43.T1.02

CK.40.B7.02

July 2001

147

PL35G Universal Compressor R134a 220-240V 50Hz Data Sheet (Replaces CD.41.C8.02) General PL35G

PL35G

Code number

101G0250

Code number (UL-recognized)

101G0251

101G

Application

R134a

Blue stripe

0250

Approvals

Application

DANFOSS COMPRESSORS

Barcode on white background

Application

MBP/HBP

Voltage range

°C

Yellow background

R

-25 to 15

V/Hz

MBP: 198 - 254 /50

PL35G 230V-60Hz 1PH

MBP: 198 - 254 /60 HBP: 198 - 254 /50 Motor type

RSIR/CSIR

Max. ambient temperature Comp. cooling at ambient temp.

THERMALLY PROTECTED

°C

38

32°C

F2

38°C

F2

S O F1

cm3

2.00

F2

Approval mark

Design Displacement Oil quantity

3

150

g

300

cm3

850

kg

4.3

cm

Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

204 170

Motor watt

A

6.6/4.2

Resistance, main and start winding (25°C) Ω

38.0/14.0

Approvals (101G0250)

EN 60335-2-34

Approvals (101G0251)

UL984/CSA-C22.2, EN 60335-2-34

Dimensions

101G0250 mm

A

C

D

ø9

E

B1 B A

137

B

135

B1

128

B2

73

B2 206 8241

location/I.D. mm

C 6.2 ±0.09

Process connector

location/I.D. mm

D 6.2 ±0.09

6.5 ±0.09

Discharge connector

location/I.D. mm

E 5.0 +0.12/+0.20

5.0 +0.12/+0.20

pcs.

ø16

101G0251

Suction connector

Compressors on a pallet

100

Cut-in current LST/HST

54 2.1/4.2 35 70

A

6.5 ±0.09 46 59 130

LRA (rated after 4 sec. UL984) LST/HST

50 60.5

Motor size

Height

8283-3

Evaporating temperature range

8283

Compressor

150 127

February 2003

148

CD.41.C9.02

CK.40.B7.02

1

August 2003

Capacity (EN 12900/CECOMAF) Evap. temp in °C -25 PL35G, 50Hz 28.0 PL35G, 60Hz 34.0

-23.3 31.6 38.5

-20 39.3 47.9

watt -15 53.0 63.8

-10 69.4 82.3

-5 89.0 104

0 112 129

5 140

7.2 153

10 172

HST c

Capacity (ASHRAE) Evap. temp in °C -25 PL35G, 50Hz 34.5 PL35G, 60Hz 42.0

15 209

watt -23.3 39.0 47.5

-20 48.5 59.1

-15 65.4 78.8

-10 85.8 102

-5 110 128

0 139 159

5 173

7.2 190

10 213

15 260

b 8225

Power consumption Evap. temp in °C -25 PL35G, 50Hz 48.0 PL35G, 60Hz 51.5

watt -23.3 49.6 54.8

-20 53.2 61.0

-15 59.5 70.2

-10 66.6 79.1

-5 74.3 87.8

0 82.2 96.4

5 90.0

7.2 93.4

10 97.5

15 104

-20 0.48 0.44

-15 0.50 0.45

-10 0.52 0.47

-5 0.54 0.49

0 0.57 0.51

5 0.59

7.2 0.61

10 0.63

15 0.66

Current consumption Evap. temp in °C -25 PL35G, 50Hz 0.46 PL35G, 60Hz 0.43

a2 d

A

-23.3 0.47 0.43

c 11

10

12

COP (EN 12900/CECOMAF) Evap. temp in °C -25 PL35G, 50Hz 0.58 PL35G, 60Hz 0.66

-23.3 0.64 0.70

W/W -20 0.74 0.78

-15 0.89 0.91

-10 1.04 1.04

-5 1.20 1.18

0 1.37 1.33

5 1.55

7.2 1.64

10 1.76

15 2.00 Main winding

COP (ASHRAE) Evap. temp in °C -25 PL35G, 50Hz 0.72 PL35G, 60Hz 0.82

Winding protector

W/W -23.3 0.79 0.87

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature 50Hz: Fan cooling F2, 220V 60Hz: Fan cooling F2, 220V

-20 0.91 0.97

-15 1.10 1.12

-10 1.29 1.29

EN 12900/CECOMAF 55°C 32°C 55°C

-5 1.48 1.46

0 1.69 1.65

13 14

5 1.93

7.2 2.04

10 2.19

Start winding

15 2.49

LST

ASHRAE 55°C 32°C 32°C

g

b 8224

a1

Accessories Devices

Fig.

PL35G

a1

103N0011 103N0018

Starting relay

a2

117U6021

Cover

b

103N0491

Starting capacitor 60 µF

c

117U5014

Cord relief

d

103N1010

Protection screen for PTC

g

103N0476

PTC starting device

6.3 mm spades 4.8 mm spades

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

118-1917 118-1918 118-1919

CD.41.C9.02

CK.40.B7.02

d Main winding a1 Start winding N

N

C

L

Winding protector

February 2003

149

TL2.5G Universal Compressor R134a 220-240V 50/60Hz Data Sheet (Replaces CG.42.X1.22) General Connector-material

102G

TL2.5G

TL2.5G Sealing

Application

Baseplate

Code number

Copper-plated steel Alumin. caps

small

102G4251

Copper-plated steel Alumin. caps

small

102G4252

Blue stripe Approvals

Copper-plated steel Rubber plugs

large

102G4250

Barcode on white background

R134a

4250

DANFOSS COMPRESSORS

Yellow background

8284-6

Compressor

Application Application

LBP/HBP

Evaporating temperature range

°F (°C)

Voltage range

-31 to 59 (-35 to 15)

V/Hz

S O F1

LBP: 187 - 254 /50 HBP: 198 - 254 /50

F2

LBP: 198 - 254 /60

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

HBP: 207 - 254 /60

LBP: S

C or D

Design

A B

3

Free gas vol. in compressor housing fl.oz. (cm ) Weight without electrical equipment

54.3 (1600)

lbs. (kg)

14.7 (6.7)

Motor ø0.75"(19)

watt

A

7.5/4.5

Resistance, main and start winding (77°F) Ω Approvals

31.5/15.0 EN 60335-2-34 with Annex AA

Dimensions

102G4250/52

Height

in. (mm) A B

102G4251

6.42 (163)

0.252-0.259 (6.5±0.09)

0.242-0.249 (6.2±0.09)

Process connector

location/I.D. in. (mm) D

0.252-0.259 (6.5±0.09)

0.242-0.249 (6.2±0.09)

Discharge connector

location/I.D. in. (mm) E 0.189-0.193 (4.9+0.10/-0) 0.202-0.205 (5.0+0.12/0.20)

August 2003

(29)

6.70"(170) 7.01"(178) 8.03"(204)

6.30 (159)

location/I.D. in. (mm) C

pcs.

1.14"

ø0.14"(3.6)

Suction connector

Compressors on a pallet

150

2.76"(70)

Cut-in current LST

ø0.63"(16)

2.8/4.5 (35)

A

6.50"(165)

ø0.35"(9) 1.38"

LRA (rated after 4 sec.UL984) LST

75

2.76"(70)

Motor size

3.94"(100)

14.0 (400)

E

5.35"(136)

oz. (g)

Maximum refrigerant charge

D C

4.21"(107)

9.5 (280)

4.13"(105)

0.16 (2.61)

fl.oz. (cm3)

or

8.74"(222) 6.93"(176)

30°

cu.in. (cm3)

8402

3.78"(96) 4.61"(117)

° 31.5 2 8°

Displacement Oil quantity

20°

4.02"(102)

HBP: F2

2.80"(71)

LBP/HBP: S

4.00"(101.6)

100°F (38°C) 110°F (43°C)

4.13"(105)

max. ambient temperature

45°

Comp. cooling at

°

110 (43)

51

°F (°C)

6.18"(157)

RSIR/CSIR

Max. ambient temperature

2.38"(60.5) 2.60" (66)

Motor type

125

CG.42.X2.22

CK.40.B7.02

1

August 2003

Capacity at LBP conditions (ASHRAE) Evap. temp. in °F Evap. temp. in °C TL2.5G, 50Hz TL2.5G, 60Hz

-30 -34.4 53.7 65.5

-20 -28.9 108 128

Btu/h

-13 -25 152 179

-10 -23.3 172 202

0 -17.8 249 291

10 -12.2 342 398

20 -6.7 453 526

30 -1.1 586 680

40 4.4 863 745

41 5 866 762

45 7.2 931 834

50 10 1019 932

59 15 1304 1127

-28.9 -20 25.2 29.9

-25 -13 35.5 41.9

-23.3 -10 40.4 47.5

-17.8 0 58.6 68.4

-12.2 10 80.4 93.7

-6.7 20 107 124

-1.1 30 138 160

4.4 40 175 203

5 41 179 208

7.2 45 196 227

10 50 219 253

15 59 264 306

-20 -28.9 54.4 61.3

-13 -25 59.5 67.4

-10 -23.3 61.9 70.2

0 -17.8 70.4 80.3

10 -12.2 79.7 91.4

20 -6.7 89.8 103

30 -1.1 101 116

40 4.4 112 129

41 5 113 132

45 7.2 117 138

50 10 123 146

59 15 134 155

-20 -28.9 0.49 0.47

-13 -25 0.50 0.48

-10 -23.3 0.50 0.49

0 -17.8 0.52 0.50

10 -12.2 0.54 0.52

20 -6.7 0.57 0.55

30 -1.1 0.59 0.57

40 4.4 0.63 0.60

41 5 0.63 0.61

45 7.2 0.64 0.62

50 10 0.66 0.64

59 15 0.69 0.67

-13 -25 2.55 2.65

-10 -23.3 2.78 2.88

0 -17.8 3.54 3.62

10 -12.2 4.28 4.35

20 -6.7 5.04 5.09

30 -1.1 5.83 5.86

40 4.4 6.67 6.67

41 5 6.76 6.58

45 7.2 7.11 6.73

50 10 7.57 6.96

59 15 8.44 8.39

-25 -13 0.60 0.62

-23.3 -10 0.65 0.67

-17.8 0 0.83 0.85

-12.2 10 1.01 1.02

-6.7 20 1.18 1.20

-1.1 30 1.37 1.37

4.4 40 1.56 1.56

5 41 1.58 1.58

7.2 45 1.66 1.66

10 50 1.77 1.77

15 59 1.97 1.97

Capacity (EN 12900/CECOMAF) Evap. temp. in °C Evap. temp. in °F TL2.5G, 50Hz TL2.5G, 60Hz

-34.4 -30 12.2 14.9

watt

Power consumption Evap. temp. in °F Evap. temp. in °C TL2.5G, 50Hz TL2.5G, 60Hz

-30 -34.4 48.1 53.8

watt

Current consumption Evap. temp. in °F Evap. temp. in °C TL2.5G, 50Hz TL2.5G, 60Hz

-30 -34.4 0.48 0.46

A

EER at LBP conditions (ASHRAE) Evap. temp. in °F Evap. temp. in °C TL2.5G, 50Hz TL2.5G, 60Hz

-30 -34.4 1.12 1.22

-20 -28.9 1.99 2.09

Btu/Wh

COP (EN 12900/CECOMAF) Evap. temp. in °C Evap. temp. in °F TL2.5G, 50Hz TL2.5G, 60Hz

-34.4 -30 0.25 0.28

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature 50Hz: Static cooling, 220V 60Hz: Static cooling, 220V

-28.9 -20 0.46 0.49

W/W

ASHRAE 130°F (54,4°C) 90°F (32°C) 90°F (32°C)

EN 12900/CECOMAF 55°C (131°F) 32°C (90°F) 55°C (131°F)

Accessories Devices

Fig.

TL2.5G

PTC star ting device 1 /4 in. (6.3 mm) spades 3 /16 in. (4.8 mm) spades

a1

103N0011 103N0018

Star ting relay

a2

117U6007

Cover

b

103N2010

Star ting capacitor 60 µF

c

117U5014

Cord relief

d

103N1010

LST

HST c

b 8217-2

b

Mounting accessories (102G4251/52) Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

Ø in. (mm) 5 /8 (16) 118-1917 5 /8 (16) 118-1918 5 /8 (16) 118-1919

Mounting accessories (102G4250) Bolt joint for one compressor Bolt joint for one compressor Snap-on for one compressor

Ø in. (mm) 5 /8 (16) 118-1946 3 /4 (19) 118-1949 5 /8 (16) 118-1947

2

August 2003

8219

a1 a2 d d Main winding a1 Start winding N

c 11

10

N

Winding protector

CG.42.X2.22

CK.40.B7.02

C

12

L

13 14

Main winding

Winding protector Start winding

August 2003

151

TL3G Universal Compressor R134a 220-240V 50Hz Data Sheet (Replaces CD.42.J6.02) General TL3G

102G

TL3G

Code number (CU-plated steel connectors)

102G4350

Code number (CU connectors, UL-recognized)

102G4352

Application

R134a

Blue stripe Approvals

Application

4350

Barcode on white background

Application

LBP/HBP °C

DANFOSS COMPRESSORS

Yellow background

-30 to 15

V/Hz

R

LBP: 187 - 254 /50

TL3G 230V-60Hz 1PH

LBP: 198 - 254 /60 HBP: 198 - 254 /50 Motor type

RSIR/CSIR

Max. ambient temperature

°C

Comp. cooling at ambient temp.

THERMALLY PROTECTED

43

32°C

Approval mark

LBP: S S O F1

HBP: F2 38°C

LBP: S HBP: F2

43°C

8284-4

Evaporating temperature range Voltage range

8284

Compressor

F2

LBP: S

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

HBP: F2

Design

ø16

Displacement

cm3

Oil quantity

cm3

280

g

400

cm3

1500

kg

6.8

35 70 100

ø9 170 178 186 204

Motor 3.5/4.9

Cut-in current LST/HST

A

8.0/4.9

E

Approvals (102G4352)

UL984/CSA-C22.2, EN 60335-2-34

Height

102G4350 mm

102G4352

A

163

B

159

8263

location/I.D. mm

C 6.2 ±0.09

Process connector

location/I.D. mm

D 6.2 ±0.09

6.5 ±0.09

Discharge connector

location/I.D. mm

E 5.0 +0.12/+0.20

5.0 +0.12/+0.20

August 2002

pcs.

6.5 ±0.09

125

CD.42.J7.02

CK.40.B7.02

45°

Suction connector

Compressors on a pallet

A B 105

EN 60335-2-34

30°

24.3/15.5

Approvals (102G4350)

Dimensions

D C

or

222 176

° 31.5 28°

Resistance, main and start winding (25°C) Ω

152

C or D

95

A

105 107

watt

LRA (rated after 4 sec. UL984) LST/HST

157 60.5 66

Motor size

102

71

Weight without electrical equipment

29

Free gas vol. in compressor

51 20° °

Maximum refrigerant charge

3.13

96 117

1

August 2003

Capacity (EN 12900/CECOMAF) Evap. temp in °C -30 TL3G, 50Hz 25.3 TL3G, 60Hz 29.5

watt

-25 40.9 47.4

-23.3 46.7 54.3

-20 59.1 68.9

-15 80.5 94.6

-10 106 125

-5 136

0 170

5 211

7.2 231

10 258

-25 50.4 58.4

-23.3 57.7 66.9

-20 72.9 85.0

-15 99.4 117

-10 131 155

-5 168

0 211

5 262

7.2 287

10 321

Capacity (ASHRAE) Evap. temp in °C -30 TL3G, 50Hz 31.2 TL3G, 60Hz 36.3

15 312

HST c

watt 15 388

b 8219

a2

Power consumption Evap. temp in °C -30 TL3G, 50Hz 57.7 TL3G, 60Hz 60.0

watt -25 65.8 69.7

-23.3 68.8 73.5

-20 75.0 81.0

-15 85.2 95.0

-10 96.2 111

-5 108

0 120

5 133

7.2 139

10 146

c

Current consumption Evap. temp in °C -30 TL3G, 50Hz 0.68 TL3G, 60Hz 0.60

A -25 0.70 0.63

-23.3 0.70 0.64

-20 0.72 0.66

-15 0.74 0.70

-10 0.77 0.74

-5 0.80

0 0.84

5 0.88

7.2 0.89

10 0.92

COP (EN 12900/CECOMAF) Evap. temp in °C -30 TL3G, 50Hz 0.44 TL3G, 60Hz 0.49

11

10

15 0.97

12

13 14

W/W

-25 0.62 0.68

-23.3 0.68 0.74

-20 0.79 0.85

-15 0.95 0.99

-10 1.10 1.13

-5 1.26

0 1.42

5 1.59

7.2 1.67

10 1.77

-25 0.77 0.84

-23.3 0.84 0.91

-20 0.97 1.04

-15 1.17 1.23

-10 1.36 1.39

-5 1.56

0 1.76

5 1.97

7.2 2.07

10 2.20

COP (ASHRAE) Evap. temp in °C -30 TL3G, 50Hz 0.54 TL3G, 60Hz 0.61

d

15 159

15 1.96

Main winding

Winding protector Start winding

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature 50Hz: Static cooling, 220V 60Hz: Static cooling, 220V

EN 12900/CECOMAF 55°C 32°C 55°C

15 2.44

LST g

ASHRAE 55°C 32°C 32°C

b 8217

a1 d Main winding a1 Start winding N

Accessories Devices PTC starting device

6.3 mm spades 4.8 mm spades

Fig.

TL3G

a1

103N0011 103N0018

Starting relay

a2

117U6009

Cover (102G4350)

b

103N2010

Cover (102G4352)

b

103N2011

Starting capacitor 60 µF

c

117U5014

Cord relief

d

103N1010

Protection screen for PTC

g

103N0476

Mounting accessories (102G4350) Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

Ø (mm) (16) (16) (16)

118-1917 118-1918 118-1919

Mounting accessories (102G4352) Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

Ø (mm) (16) (19) (16)

118-1945 118-1948 118-1944

2

August 2003

CD.42.J7.02

CK.40.B7.02

N

C

L

Winding protector

August 2002

153

TL4G Universal Compressor R134a 220-240V 50Hz Data Sheet (Replaces CG.42.A2.02) General TL4G

102G

TL4G

Code number (small baseplate)

102G4452

Code number (large baseplate, UL-recognized)

102G4454

Application

R134a

Blue stripe Approvals

Application Application

LBP/HBP

Evaporating temperature range

°C

4452

Barcode on white background

DANFOSS COMPRESSORS

Yellow background

8284-2

Compressor

-30 to 15 R

V/Hz

LBP: 187 - 254 /50 LBP: 198 - 254 /60

TL4G 230V-60Hz 1PH

HBP: 198 - 254 /50 Motor type

RSIR/CSIR

Max. ambient temperature

°C

Comp. cooling at ambient temp.

43

32°C

THERMALLY PROTECTED

LBP: S

Approval mark

HBP: F2 38°C

S O F1

LBP: S HBP: F2

43°C

8284-4

Voltage range

LBP: S

F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

HBP: F2

Design 3.86

Oil quantity

cm3

280

Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment

g

400

cm3

1690

kg

7.5

ø3.6

ø16

101.6 136

cm3

35 70 100

Displacement

ø9

Motor

ø19

watt

170 178 186 204

110

LRA (rated after 4 sec. UL984) LST/HST

A

4.3/5.1

Cut-in current LST/HST

A

8.6/5.1

Resistance, main and start winding (25°C) Ω

C or D

18.2/15.1

UL984/CSA-C22.2, EN 60335-2-34

A

173

B

169

location/I.D. mm

C 6.2 ±0.09

6.5 ±0.09

Process connector

location/I.D. mm

D 6.2 ±0.09

6.5 ±0.09

Discharge connector

location/I.D. mm

E 5.0 +0.12/+0.20

Compressors on a pallet

pcs.

5.0 +0.12/+0.20

105

8428

45°

Suction connector

125 102

August 2003

154

CG.42.A3.02

CK.40.B7.02

51 20° °

mm

102G4454

157 60.5 66

Height

102G4452

105 107

A B

Dimensions

71

Approvals (102G4454)

E

29

EN 60335-2-34

° 31.5 28°

Approvals (102G4452)

D C

or

222 176

30°

Motor size

96 117

1

August 2003

Capacity (EN 12900/CECOMAF) Evap. temp in °C -30 TL4G, 50Hz 40.8 TL4G, 60Hz 48.4

watt

-25 58.3 69.5

-23.3 65.3 77.8

-20 80.3 95.7

-15 107 127

-10 140 166

-5 180

0 226

5 280

7.2 306

10 342

-25 71.9 85.8

-23.3 80.5 96.0

-20 99.2 118

-15 133 157

-10 173 205

-5 222

0 280

5 347

7.2 380

10 425

Capacity (ASHRAE) Evap. temp in °C -30 TL4G, 50Hz 50.3 TL4G, 60Hz 59.6

15 413

HST c

watt 15 515

b 8219

a2

Power consumption Evap. temp in °C -30 TL4G, 50Hz 71.7 TL4G, 60Hz 74.2

watt -25 82.7 86.8

-23.3 86.6 91.6

-20 94.2 101

-15 106 117

-10 118 135

-5 130

0 142

5 154

7.2 159

10 165

c

Current consumption Evap. temp in °C -30 TL4G, 50Hz 0.82 TL4G, 60Hz 0.70

A -25 0.84 0.74

-23.3 0.85 0.76

-20 0.87 0.79

-15 0.90 0.84

-10 0.93 0.90

-5 0.96

0 1.00

5 1.04

7.2 1.05

10 1.08

COP (EN 12900/CECOMAF) Evap. temp in °C -30 TL4G, 50Hz 0.57 TL4G, 60Hz 0.65

11

10

15 1.12

12

13 14

W/W

-25 0.70 0.80

-23.3 0.75 0.85

-20 0.85 0.94

-15 1.01 1.09

-10 1.19 1.23

-5 1.38

0 1.59

5 1.82

7.2 1.93

10 2.07

-25 0.87 0.99

-23.3 0.93 1.05

-20 1.05 1.17

-15 1.25 1.34

-10 1.47 1.52

-5 1.71

0 1.97

5 2.26

7.2 2.39

10 2.57

COP (ASHRAE) Evap. temp in °C -30 TL4G, 50Hz 0.70 TL4G, 60Hz 0.80

d

15 176

15 2.34

Main winding

Winding protector Start winding

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature 50Hz: Static cooling, 220V 60Hz: Static cooling, 220V

EN 12900/CECOMAF 55°C 32°C 55°C

15 2.92

LST g

ASHRAE 55°C 32°C 32°C

b 8217

a1 d Main winding a1 Start winding N

Accessories Devices

Fig.

TL4G

a1

103N0011 103N0018

Star ting relay

a2

117U6004

Cover (102G4452)

b

103N2010

PTC star ting device

6.3 mm spades 4.8 mm spades

Cover (102G4454)

b

103N2011

Star ting capacitor 60 µF

c

117U5014

Cord relief

d

103N1010

Protection screen for PTC

g

103N0476

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

N

C

L

Winding protector

118-1917 118-1918 118-1919

CG.42.A3.02

CK.40.B7.02

August 2003

155

TL5G Universal Compressor R134a 220-240V 50Hz Data Sheet (Replaces CG.42.C1.02) General TL5G

Code number

102G4550

102G

TL5G Application

R134a

Blue stripe Approvals

Application Application Evaporating temperature range Voltage range

°C V/Hz

LBP/HBP

Barcode on white background

-30 to 15

Yellow background

4550

8284-3

Compressor

DANFOSS COMPRESSORS

LBP: 187 - 254 /50 LBP: 198 - 254 /60 HBP: 198 - 254 /50

Motor type

RSIR/CSIR

Max. ambient temperature

°C

Comp. cooling at ambient temp.

43

32°C

LBP: S HBP: F2

38°C

S O F1

LBP: S HBP: F2

43°C

LBP: S F2

HBP: F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

Design cm3

5.08

Oil quantity

cm3

280

Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment

g

400

cm3

1690

kg

7.5

ø16

35 70 100

Displacement

ø9

Motor watt

170 178 186 204

140

LRA (rated after 4 sec. UL984) LST/HST

A

5.4/5.7

Cut-in current LST/HST

A

9.7/5.7

Resistance, main and start winding (25°C) Ω

C or D

E

14.5/14.8 30°

EN 60335-2-34

° 31.5 28°

105

A B

169

Suction connector

location/I.D. mm

C

6.2 ±0.09

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

5.0 +0.12/+0.20

pcs.

125

8263

45°

Compressors on a pallet

173

102

May 2001

156

CG.42.C2.02

CK.40.B7.02

51 20° °

mm

157 60.5 66

Height

105 107

A B

Dimensions

71

Approvals

D C

or

222 176

29

Motor size

96 117

1

August 2003

Capacity (EN 12900/CECOMAF) Evap. temp in °C -30 TL5G, 50Hz 55.6 TL5G, 60Hz 64.7

watt

-25 79.0 91.5

-23.3 87.9 102

-20 107 123

-15 139 162

-10 178 207

-5 224

0 278

5 341

7.2 372

10 414

-25 97.5 113

-23.3 108 125

-20 132 152

-15 172 200

-10 220 256

-5 277

0 345

5 423

7.2 461

10 514

Capacity (ASHRAE) Evap. temp in °C -30 TL5G, 50Hz 68.6 TL5G, 60Hz 79.8

15 497

HST c

watt 15 619

b 8219

a2

Power consumption

watt

Evap. temp in °C -30 -25 -23.3 TL5G, 50Hz 84.8 100 105 TL5G, 60Hz 88.7 105.7 112.1

-20 116 125

-15 132 147

-10 149 170

-5 167

0 186

5 205

7.2 213

10 224

c

Current consumption Evap. temp in °C -30 TL5G, 50Hz 0.95 TL5G, 60Hz 0.83

A -25 0.98 0.88

-23.3 0.99 0.90

-20 1.01 0.94

-15 1.05 1.01

-10 1.09 1.08

-5 1.15

0 1.21

5 1.28

7.2 1.32

10 1.36

COP (EN 12900/CECOMAF) Evap. temp in °C -30 TL5G, 50Hz 0.66 TL5G, 60Hz 0.73

11

10

15 1.45

12

13 14

W/W

-25 0.79 0.87

-23.3 0.83 0.91

-20 0.92 0.99

-15 1.05 1.10

-10 1.19 1.22

-5 1.34

0 1.50

5 1.67

7.2 1.74

10 1.84

-25 0.97 1.07

-23.3 1.03 1.12

-20 1.14 1.22

-15 1.30 1.36

-10 1.47 1.51

-5 1.66

0 1.86

5 2.07

7.2 2.16

10 2.29

COP (ASHRAE) Evap. temp in °C -30 TL5G, 50Hz 0.81 TL5G, 60Hz 0.90

d

15 245

15 2.03

Main winding

Winding protector Start winding

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature 50Hz: Static cooling, 220V 60Hz: Static cooling, 220V

EN 12900/CECOMAF 55°C 32°C 55°C

15 2.53

LST g

ASHRAE 55°C 32°C 32°C

b 8217

a1 d Main winding a1 Start winding N

Accessories Devices

Fig.

TL5G

a1

103N0011 103N0018

Starting relay

a2

117U6000

Cover

b

103N2010

Starting capacitor 60 µF

c

117U5014

Cord relief

d

103N1010

Protection screen for PTC

g

103N0476

PTC starting device

6.3 mm spades 4.8 mm spades

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

N

C

L

Winding protector

118-1917 118-1918 118-1919

CG.42.C2.02

CK.40.B7.02

May 2001

157

FR6G Universal Compressor R134a 220-240V 50Hz Data Sheet (Replaces CD.43.I5.02) General FR6G

Code number

103G6660

103G

FR6G Application

R134a

Blue stripe Approvals

Application Application Evaporating temperature range Voltage range

°C V/Hz

LBP/HBP

Barcode on white background

-30 to 10

Yellow background

6660

8285-3

Compressor

DANFOSS COMPRESSORS

LBP: 187 - 254 /50 LBP: 198 - 254 /60 HBP: 198 - 254 /50

Motor type

S O F1

RSIR/CSIR

Max. ambient temperature

°C

Comp. cooling at ambient temp.

43

32°C

LBP: S

F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

HBP: F2 38°C

LBP: S HBP: F2

43°C

LBP: S HBP: F2

Design

204 178

ø16

Displacement

cm3

Oil quantity

cm3

450

g

900

cm3

1350

kg

10.6

Free gas vol. in compressor Weight without electrical equipment

35 127 150

101.6 70 60.5

Maximum refrigerant charge

ø9.7

127 165 170 186 200

Motor watt

150

A

D

5.8/7.5

A

10.5/7.5

Resistance, main and start winding (25°C)



12.6/12.4 A B

127

EN 60335-2-34

25°

Approvals

30°

Cut-in current LST/HST

C E

102 130

LRA (rated after 4 sec. UL984) LST/HST

30°

Motor size

ø19

6.23

Dimensions

location/I.D. mm

C

8.2 ±0.09

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

6.2 ±0.09

Compressors on a pallet

pcs.

158

24°

80 122.5

May 2001

8253

32 55

Suction connector

243

40°

196 191

40°

A B

156

mm

55

Height

CD.43.I6.02

CK.40.B7.02

124.5 127.5

1

August 2003

Capacity (EN 12900/CECOMAF) Evap. temp in °C -30 FR6G, 50Hz 47.7 FR6G, 60Hz 50.6

watt

-25 83.3 92.5

-23.3 96.5 108

-20 124 141

-15 171 199

-10 226 266

-5 290

0 365

5 452

7.2 494

-25 103 114

-23.3 119 134

-20 153 175

-15 211 246

-10 279 329

-5 359

0 452

5 561

7.2 614

Capacity (ASHRAE) Evap. temp in °C -30 FR6G, 50Hz 58.9 FR6G, 60Hz 62.4

c

10 687

b 8219

a2

watt -25 109 119

-23.3 115 127

-20 129 144

-15 149 170

-10 172 197

-5 194

0 218

5 241

7.2 251

10 264

-25 0.85 0.77

-23.3 0.87 0.80

-20 0.91 0.86

-15 0.98 0.97

-10 1.06 1.09

-5 1.14

0 1.23

5 1.33

7.2 1.37

10 1.43

Current consumption Evap. temp in °C -30 FR6G, 50Hz 0.79 FR6G, 60Hz 0.69

HST

watt

Power consumption Evap. temp in °C -30 FR6G, 50Hz 91.3 FR6G, 60Hz 94.8

10 552

d

A

c 11

10

12

13 14

COP (EN 12900/CECOMAF) Evap. temp in °C -30 FR6G, 50Hz 0.52 FR6G, 60Hz 0.53

W/W

-25 0.76 0.78

-23.3 0.84 0.85

-20 0.96 0.98

-15 1.14 1.17

-10 1.32 1.35

-5 1.49

0 1.68

5 1.88

7.2 1.97

-25 0.94 0.96

-23.3 1.03 1.05

-20 1.19 1.21

-15 1.41 1.44

-10 1.63 1.67

-5 1.85

0 2.08

5 2.33

7.2 2.44

COP (ASHRAE) Evap. temp in °C -30 FR6G, 50Hz 0.64 FR6G, 60Hz 0.66

10 2.09

Main winding

Winding protector Start winding

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature 50Hz: Fan cooling F2, 220V 60Hz: Fan cooling F2, 220V

EN 12900/CECOMAF 55°C 32°C 55°C

10 2.60

LST g

ASHRAE 55°C 32°C 32°C

b 8217

a1 d Main winding a1 Start winding

Accessories Devices

Fig.

FR6G

a1

103N0011 103N0018

Starting relay

a2

117U6000 103N2010

PTC starting device

6.3 mm spades 4.8 mm spades

Cover

b

Starting capacitor 80 µF

c

117U5015

Cord relief

d

103N1010

Protection screen for PTC

g

103N0476

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

N

N

C

L

Winding protector

118-1917 118-1918 118-1919

CD.43.I6.02

CK.40.B7.02

May 2001

159

FR7.5G Universal Compressor R134a 220-240V 50Hz Data Sheet (Replaces CG.43.F1.02) General FR7.5G

Code number

103G6680

Code number compressor with oil cooler

103G6690

103G

FR7.5G Application

R134a

Blue stripe Approvals

Application

6680

Barcode on white background

Application

LBP/HBP

Evaporating temperature range Voltage range

°C

LBP: 187 - 254 /50 LBP: 198 - 254 /60

S O F1

HBP: 198 - 254 /50 Motor type

RSIR/CSIR °C

Comp. cooling at ambient temp.

DANFOSS COMPRESSORS

Yellow background

-30 to 10

V/Hz

Max. ambient temperature

8285

Compressor

43

32°C

F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

LBP: S HBP: F2

38°C

LBP: S HBP: F2

43°C

LBP: O/F1 HBP: F2 204 178

ø16

Design Displacement

cm3

Oil quantity

cm3

450

g

900

cm3

1350

kg

10.6

watt

175

Free gas vol. in compressor Weight without electrical equipment

6.93 35 127 150

101.6 70 60.5

Maximum refrigerant charge

ø9.7

127 165 170 186 200

Motor

11.4/8.1

Resistance, main and start winding (25°C)



10.7/13.0

A B

EN 60335-2-34, CCIB

34

127

Approvals

102 130

6.8/8.1

A

25°

A

Cut-in current LST/HST

C E 30°

LRA (rated after 4 sec. UL984) LST/HST

D

30°

Motor size

ø19

Dimensions

6.2 ±0.09

Discharge connector

location/I.D. mm

E

6.2 ±0.09

Oil cooler

location/I.D. mm

F

6.2 ±0.09

May 2001

pcs.

80

CG.43.F2.02

CK.40.B7.02

40

8.2 ±0.09

D

122.5

24°

32 55

C

location/I.D. mm

F 8266

40°

location/I.D. mm

Process connector

243 264

40°

196 191

156

A B

Suction connector

Compressors on a pallet

160

mm

55

Height

124.5 127.5

1

August 2003

Capacity (EN 12900/CECOMAF) Evap. temp in °C -30 FR7.5G, 50Hz 61.7 FR7.5G, 60Hz 66.5

watt

-25 99.0 112

-23.3 113 130

-20 142 166

-15 193 228

-10 254 300

-5 325

0 408

5 505

7.2 553

-25 122 139

-23.3 139 160

-20 176 204

-15 239 281

-10 314 371

-5 402

0 506

5 627

7.2 687

Capacity (ASHRAE) Evap. temp in °C -30 FR7.5G, 50Hz 76.1 FR7.5G, 60Hz 82.0

-30 108 110

c

10 768

b 8219

a2

watt -25 126 138

-23.3 133 148

-20 147 167

-15 170 198

-10 194 229

-5 220

0 246

5 272

7.2 284

10 298

-25 -23.3 0.90 0.93 0.81 0.85

-20 0.99 0.94

-15 1.09 1.07

-10 1.19 1.19

-5 1.30

0 1.41

5 1.52

7.2 1.58

10 1.64

Current consumption Evap. temp in °C -30 FR7.5G, 50Hz 0.81 FR7.5G, 60Hz 0.67

HST

watt

Power consumption Evap. temp in °C FR7.5G, 50Hz FR7.5G, 60Hz

10 618

d

A

c 11

10

12

13 14

COP (EN 12900/CECOMAF) Evap. temp in °C -30 FR7.5G, 50Hz 0.57 FR7.5G, 60Hz 0.60

W/W

-25 -23.3 0.79 0.85 0.81 0.88

-20 0.97 0.99

-15 1.14 1.15

-10 1.30 1.31

-5 1.48

0 1.66

5 1.86

7.2 1.95

-25 0.97 1.00

-20 1.20 1.22

-15 1.41 1.42

-10 1.61 1.62

-5 1.83

0 2.05

5 2.30

7.2 2.42

COP (ASHRAE) Evap. temp in °C -30 FR7.5G, 50Hz 0.71 FR7.5G, 60Hz 0.74

10 2.07

Main winding

Winding protector Start winding

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature 50Hz: Fan cooling F2, 220V 60Hz: Fan cooling F2, 220V

-23.3 1.05 1.08

EN 12900/CECOMAF 55°C 32°C 55°C

10 2.58

LST g

ASHRAE 55°C 32°C 32°C

b 8217

a1 d Main winding a1 Start winding

Accessories Devices

Fig.

FR7.5G

a1

103N0011 103N0018

Starting relay

a2

117U6001 103N2010

PTC starting device

6.3 mm spades 4.8 mm spades

Cover

b

Starting capacitor 80 µF

c

117U5015

Cord relief

d

103N1010

Protection screen for PTC

g

103N0476

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

N

N

C

L

Winding protector

118-1917 118-1918 118-1919

CG.43.F2.02

CK.40.B7.02

May 2001

161

FR8.5G Universal Compressor R134a 220-240V 50Hz Data Sheet (CG.43.H1.02) General FR8.5G

Code number

103G6780

Code number compressor with oil cooler

103G6790

103G

FR8.5G Application

R134a

Blue stripe Approvals

Application

6780

Barcode on white background

Application

LBP/HBP

Evaporating temperature range Voltage range

°C

LBP: 187 - 254 /50 LBP: 198 - 254 /60

S O F1

HBP: 198 - 254 /50 Motor type

RSIR/CSIR °C

Comp. cooling at ambient temp.

DANFOSS COMPRESSORS

Yellow background

-30 to 10

V/Hz

Max. ambient temperature

8285-4

Compressor

43

32°C

F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

LBP: S HBP: F2

38°C

LBP: O/F1

43°C

LBP: O/F1

HBP: F2 HBP: F2 204 178

ø16

Design Displacement

cm3

Oil quantity

cm3

450

g

900

cm3

1350

kg

10.6

Free gas vol. in compressor Weight without electrical equipment

7.95 35 127 150

101.6 70 60.5

Maximum refrigerant charge

ø9.7

127 165 170 186 200

Motor 215

Cut-in current LST/HST

A

12.8/8.2

Resistance, main and start winding (25°C)



8.9/12.0

C E

A B

EN 60335-2-34, CCIB

34

127

Approvals

D

25°

8.1/8.2

30°

A

102 130

watt

LRA (rated after 4 sec. UL984) LST/HST

30°

Motor size

ø19

Dimensions

6.2 ±0.09

Discharge connector

location/I.D. mm

E

6.2 ±0.09

Oil cooler

location/I.D. mm

F

6.2 ±0.09

May 2001

pcs.

80

CG.43.H2.02

CK.40.B7.02

40

8.2 ±0.09

D

122.5

24°

32 55

C

location/I.D. mm

F 8266

40°

location/I.D. mm

Process connector

243 264

40°

196 191

156

A B

Suction connector

Compressors on a pallet

162

mm

55

Height

124.5 127.5

1

August 2003

Capacity (EN 12900/CECOMAF) Evap. temp in °C -30 FR8.5G, 50Hz 84.9 FR8.5G, 60Hz 92.3

watt

-25 123 138

-23.3 138 156

-20 171 195

-15 228 263

-10 298 345

-5 381

0 478

5 592

7.2 647

-25 152 171

-23.3 171 193

-20 211 241

-15 282 325

-10 368 426

-5 471

0 592

5 734

7.2 803

Capacity (ASHRAE) Evap. temp in °C FR8.5G, 50Hz FR8.5G, 60Hz

-30 105 114

-30 127 134

c

10 898

b 8219

a2

watt -25 151 164

-23.3 159 174

-20 176 197

-15 203 233

-10 231 273

-5 261

0 291

5 321

7.2 335

10 352

-25 1.22 1.12

-23.3 1.25 1.16

-20 1.30 1.24

-15 1.38 1.37

-10 1.47 1.53

-5 1.56

0 1.67

5 1.78

7.2 1.83

10 1.90

Current consumption Evap. temp in °C -30 FR8.5G, 50Hz 1.16 FR8.5G, 60Hz 1.02

HST

watt

Power consumption Evap. temp in °C FR8.5G, 50Hz FR8.5G, 60Hz

10 722

d

A

c 11

10

12

13 14

COP (EN 12900/CECOMAF) Evap. temp in °C -30 FR8.5G, 50Hz 0.67 FR8.5G, 60Hz 0.69

-25 0.82 0.85

W/W

-23.3 0.87 0.90

-20 0.97 0.99

-15 1.12 1.13

-10 1.29 1.26

-5 1.46

0 1.65

5 1.84

7.2 1.93

-25 -23.3 1.01 1.07 1.04 1.11

-20 1.19 1.22

-15 1.39 1.39

-10 1.59 1.56

-5 1.81

0 2.04

5 2.29

7.2 2.40

COP (ASHRAE) Evap. temp in °C -30 FR8.5G, 50Hz 0.83 FR8.5G, 60Hz 0.85

10 2.05

Main winding

Winding protector Start winding

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature 50Hz: Fan cooling F2, 220V 60Hz: Fan cooling F2, 220V

EN 12900/CECOMAF 55°C 32°C 55°C

10 2.55

LST g

ASHRAE 55°C 32°C 32°C

b 8217

a1 d Main winding a1 Start winding

Accessories Devices

Fig.

FR8.5G

a1

103N0011 103N0018

Starting relay

a2

117U6015 103N2010

PTC starting device

6.3 mm spades 4.8 mm spades

Cover

b

Starting capacitor 80 µF

c

117U5015

Cord relief

d

103N1010

Protection screen for PTC

g

103N0476

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

N

N

C

L

Winding protector

118-1917 118-1918 118-1919

CG.43.H2.02

CK.40.B7.02

May 2001

163

FR10G Universal Compressor R134a 220-240V 50Hz Data Sheet (Replaces CD.43.O5.02) General FR10G

Code number

103G6880

Code number compressor with oil cooler

103G6890

103G

FR10G Application

R134a

Blue stripe Approvals

Application

6880

Barcode on white background

Application

LBP/HBP

Evaporating temperature range Voltage range

°C

LBP: 187 - 254 /50 LBP: 198 - 254 /60

S O F1

HBP: 198 - 254 /50 Motor type

RSIR/CSIR °C

Comp. cooling at ambient temp.

DANFOSS COMPRESSORS

Yellow background

-30 to 10

V/Hz

Max. ambient temperature

8285-2

Compressor

43

32°C

F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

LBP: S HBP: F2

38°C

LBP: O/F1

43°C

LBP: O/F1

HBP: F2 HBP: F2 204 178

ø16

Design Displacement

cm3

Oil quantity

cm3

450

g

900

cm3

1350

kg

10.6

watt

275

Motor Motor size

10.3/10.0

A

15.0/10.0

Resistance, main and start winding (25°C)



7.3/12.0

35 127 150

C E

A B

EN 60335-2-34, CCIB

34

127

Approvals

D

25°

A

Cut-in current LST/HST

127 165 170 186 200

30°

LRA (rated after 4 sec. UL984) LST/HST

ø9.7

102 130

Weight without electrical equipment

30°

Free gas vol. in compressor

9.05 101.6 70 60.5

Maximum refrigerant charge

ø19

Dimensions

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

6.2 ±0.09

Oil cooler

location/I.D. mm

F

6.2 ±0.09

May 2001

pcs.

80

CD.43.O6.02

CK.40.B7.02

40

C

location/I.D. mm

F 8266

122.5

24°

32 55

8.2 ±0.09

location/I.D. mm

Process connector

243 264

40°

191

40°

196

B

156

A

Suction connector

Compressors on a pallet

164

mm

55

Height

124.5 127.5

1

August 2003

Capacity (EN 12900/CECOMAF) Evap. temp in °C -30 FR10G, 50Hz 91.9 FR10G, 60Hz 98.8

watt

-25 136 153

-23.3 152 173

-20 188 217

-15 250 292

-10 324 381

-5 412

0 516

5 638

7.2 697

-25 167 188

-23.3 188 214

-20 232 267

-15 308 361

-10 400 471

-5 510

0 639

5 791

7.2 866

Capacity (ASHRAE) Evap. temp in °C FR10G, 50Hz FR10G, 60Hz

-30 113 122

-30 155 163

c

10 968

b 8219

a2

watt -25 179 194

-23.3 188 206

-20 205 230

-15 234 270

-10 265 314

-5 296

0 329

5 362

7.2 376

10 394

-25 1.58 1.44

-23.3 1.61 1.48

-20 1.66 1.57

-15 1.75 1.73

-10 1.84 1.90

-5 1.94

0 2.05

5 2.16

7.2 2.21

10 2.28

Current consumption Evap. temp in °C -30 FR10G, 50Hz 1.51 FR10G, 60Hz 1.32

HST

watt

Power consumption Evap. temp in °C FR10G, 50Hz FR10G, 60Hz

10 779

d

A

c 11

10

12

13 14

COP (EN 12900/CECOMAF) Evap. temp in °C -30 FR10G, 50Hz 0.59 FR10G, 60Hz 0.61

W/W

-25 0.76 0.79

-23.3 0.81 0.84

-20 0.91 0.94

-15 1.07 1.08

-10 1.22 1.21

-5 1.39

0 1.57

5 1.76

7.2 1.85

-25 0.93 0.97

-23.3 1.00 1.04

-20 1.13 1.16

-15 1.32 1.34

-10 1.51 1.50

-5 1.72

0 1.94

5 2.19

7.2 2.30

COP (ASHRAE) Evap. temp in °C -30 FR10G, 50Hz 0.73 FR10G, 60Hz 0.75

10 1.98

Main winding

Winding protector Start winding

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature 50Hz: Fan cooling F2, 220V 60Hz: Fan cooling F2, 220V

EN 12900/CECOMAF 55°C 32°C 55°C

10 2.46

LST g

ASHRAE 55°C 32°C 32°C

b 8217

a1 d Main winding a1 Start winding

Accessories Devices

Fig.

FR10G

a1

103N0011 103N0018

Starting relay

a2

117U6010 103N2010

PTC starting device

6.3 mm spades 4.8 mm spades

Cover

b

Starting capacitor 80 µF

c

117U5015

Cord relief

d

103N1010

Protection screen for PTC

g

103N0476

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

N

N

C

L

Winding protector

118-1917 118-1918 118-1919

CD.43.O6.02

CK.40.B7.02

May 2001

165

FR11G Universal Compressor R134a 220-240V 50Hz Data Sheet (Replaces CG.43.E1.02) General FR11G

Code number

103G6980

103G

FR11G Application

R134a

Blue stripe Approvals

Application Application Evaporating temperature range Voltage range

°C V/Hz

LBP/HBP

Barcode on white background

-30 to 5

Yellow background

6980

8285-5

Compressor

DANFOSS COMPRESSORS

LBP: 187 - 254 /50 HBP: 198 - 254 /50

Motor type

RSIR/CSIR

Max. ambient temperature

°C

Comp. cooling at ambient temp.

S O F1

43

32°C

LBP: F2 HBP: F2

38°C

F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

LBP: F2 HBP: F2

43°C

LBP: F2 HBP: F2

Design cm3

11.15

3

cm

Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment

450

g

900

cm3

1350

kg

10.6

watt

275

Motor

ø9.7

Motor size LRA (rated after 4 sec. UL984) LST/HST

A

10.3/10.0

Cut-in current LST/HST

A

15.0/10.0

Resistance, main and start winding (25°C)



ø19

35 127 150

Oil quantity

204 178

ø16

101.6 70 60.5

Displacement

127 165 170 186 200

D

C E

7.3/12.0 30°

EN 60335-2-34, CCIB

30°

Approvals

25°

location/I.D. mm

C

8.2 ±0.09

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

6.2 ±0.09

pcs.

80

55

Compressors on a pallet

243

122.5

May 2001

166

CG.43.E2.02

CK.40.B7.02

8253

24°

40°

191

Suction connector

32 55

196

B

40°

A

127

mm

156

Height

102 130

A B

Dimensions

124.5 127.5

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C FR11G

-30 115

-25 170

-23.3 191

watt -20 233

-15 307

-10 395

-5 501

0 628

5 780

HST c

Capacity (ASHRAE) Comp.\°C FR11G

-30 141

-25 209

watt -23.3 235

-20 287

-15 378

-10 487

-5 619

0 777

5 966 b

Power consumption Comp.\°C FR11G

-30 165

-25 202

watt -23.3 215

-20 240

-15 278

-10 317

-5 357

0 400

8219

5 445

a2 d

Current consumption Comp.\°C FR11G

-30 1.52

-25 1.59

A -23.3 1.63

-20 1.69

-15 1.81

-10 1.95

-5 2.10

0 2.26

5 2.42

c 11

10

COP (EN 12900/CECOMAF) Comp.\°C FR11G

-30 0.70

W/W

-25 0.84

-23.3 0.89

-20 0.97

-15 1.11

-10 1.25

-5 1.40

0 1.57

-25 1.04

-23.3 1.09

-20 1.20

-15 1.36

-10 1.54

-5 1.73

0 1.94

COP (ASHRAE) Comp.\°C FR11G

-30 0.86

5 1.75

12

13 14

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Fan cooling F2, 220V 50Hz

EN 12900/CECOMAF 55°C 32°C 55°C

5 2.17

ASHRAE 55°C 32°C 32°C

Main winding

Winding protector Start winding

LST g

b 8217

a1

Accessories Devices

Fig.

FR11G

a1

103N0011 103N0018

Starting relay

a2

117U6010 103N2010

PTC starting device

6.3 mm spades 4.8 mm spades

d Main winding a1 Start winding N

Cover

b

Starting capacitor 80 µF

c

117U5015

Cord relief

d

103N1010

Protection screen for PTC

g

103N0476

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

118-1917 118-1918 118-1919

CG.43.E2.02

CK.40.B7.02

N

C

L

Winding protector

May 2001

167

SC10G Universal Compressor R134a 220-240V 50Hz Data Sheet (Replaces CD.44.C5.02) General SC10G

Code number

104G8000

Application Application

LBP/HBP

Evaporating temperature range Voltage range

°C

-35 to 15

V/Hz

104G

SC10G Application

R134a

Blue stripe Approvals

8000

Barcode on white background

DANFOSS COMPRESSORS

Yellow background

8286

Compressor

LBP: 187 - 254 /50 LBP: 198 - 254 /60 HBP: 198 - 254 /50

Motor type

S O F1

RSIR/CSIR

Max. ambient temperature

°C

Comp. cooling at ambient temp.

43

32°C

LBP: F1

F2

HBP: F2 38°C

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

LBP: F1 HBP: F2

43°C

LBP: F1 HBP: F2

Design cm3 cm

Free gas vol. in compressor Weight without electrical equipment

550 (500 on comp. with oil cooler)

g

1300

cm3

1510

kg

12.1

watt

250

Motor Motor size LRA (rated after 4 sec. UL984) LST/HST

A

10.2/11.1

Cut-in current LST/HST

A

14.6/11.1

Resistance, main and start winding (25°C)



8.5/14.1

Approvals

ø19 ø9.7

70 150

Oil quantity Maximum refrigerant charge

3

204 178 170

ø16

10.29

127 101.6 35

Displacement

127 165 186 218

D

C E

EN 60335-2-34 B A

B1

Dimensions

B2

mm

A

199

B

193

B1

173

B2

90

3

Height

6.2 ±0.09

Discharge connector

location/I.D. mm

E

6.2 ±0.09

Compressors on a pallet

August 2003

168

pcs.

80

CD.44.C6.02

CK.40.B7.02

63

8.2 ±0.09

D

37°

37°

107

107 115

55 63

C

location/I.D. mm

55

location/I.D. mm

Process connector

151

Suction connector

255

8258

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C SC10G

-35 23

-30 60

-25 113

-23.3 135

watt -20 183

-15 268

-10 369

-5 486

0 618

5 764

7.2 833

10 925

15 1100

HST c

Capacity (ASHRAE) Comp.\°C SC10G

-35 29

-30 74

watt -25 139

-23.3 166

-20 225

-15 331

-10 456

-5 600

0 764

5 946

7.2 10 15 1032 1147 1367

b 8222

a2

Power consumption Comp.\°C SC10G

-35 93

-30 139

watt -25 -23.3 181 195

-20 220

-15 256

-10 290

-5 322

0 353

5 383

7.2 396

10 412

d

15 441

c

Current consumption Comp.\°C SC10G

-35 1.29

-30 1.34

A -25 -23.3 -20 1.41 1.44 1.50

-15 1.61

-10 1.72

-5 1.85

0 1.98

5 2.12

7.2 2.18

10 2.26

COP (EN 12900/CECOMAF) Comp.\°C SC10G

-35 0.25

-35 0.31

15 2.40

12

13 14

W/W

-30 0.43

-25 -23.3 -20 0.63 0.69 0.83

-15 1.05

-10 1.27

-5 1.51

0 1.75

5 2.00

7.2 2.11

10 2.25

-30 0.53

-25 -23.3 -20 0.77 0.85 1.02

-15 1.29

-10 1.57

-5 1.86

0 2.16

5 2.47

7.2 2.61

10 2.78

COP (ASHRAE) Comp.\°C SC10G

11

10

15 2.49

Start winding Main winding Winding protector

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Fan cooling, 220V 50Hz

EN 12900/CECOMAF 55°C 32°C 55°C

ASHRAE 55°C 32°C 32°C

15 3.10

LST

b 8221

a1 d Main winding

a1

Start winding

N

Accessories Devices PTC starting device

6.3 mm spades

Fig.

SC10G

a1

103N0002

Starting relay

a2

117U6002

Cover

b

103N2009

Starting capacitor 80 µF

c

117U5017

Cord relief

d

103N1004

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

N

C

L

Winding protector

118-1917 118-1918 118-1919

CD.44.C6.02

CK.40.B7.02

August 2003

169

SC12G Universal Compressor R134a 220-240V 50Hz Data Sheet (Replaces CD.44.P3.02) General SC12G

Code number

104G8240

Code number

104G8243

Code number compressor with oil cooler

104G8250

104G

SC12G Application

R134a

Blue stripe Approvals

8240

Barcode on white background

Application Application Evaporating temperature range Voltage range

°C

-35 to 15

V/Hz

LBP: 187 - 254 /50 LBP: 198 - 254 /60

S O F1

HBP: 198 - 254 /50 Motor type

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

RSIR/CSIR

Max. ambient temperature

°C

Comp. cooling at ambient temp.

DANFOSS COMPRESSORS

Yellow background

LBP/HBP

8286-6

Compressor

43

F2

32°C

LBP: O/F1

38°C

LBP: O/F1

43°C

LBP: O/F1

HBP: F2 HBP: F2 HBP: F2

204 178 170

ø16

Design Displacement

cm 3

Oil quantity

cm 3 550 (500 on comp. with oil cooler)

kg

12.6

Motor watt A

12.4/12.6

Cut-in current LST/HST

A

17.2/12.6

Resistance, main and start winding (25°C)



E

EN 60335-2-34

A

209

B

203

B1

183

F

100

location/I.D. mm

C 8.2 ±0.09

8.2 ±0.09

10.2 ±0.09

Process connector

location/I.D. mm

D 6.2 ±0.09

6.2 ±0.09

6.5 ±0.09

6.2 ±0.09

6.5 ±0.09

Discharge connector

location/I.D. mm

E 6.2 ±0.09

Oil cooler

location/I.D. mm

F

August 2003

pcs.

B2

255

Suction connector

Compressors on a pallet

15

6.2 ±0.09

63

B2

30

104G8240 104G8243

53

104G8250

B A

B1

3

Dimensions mm

C

6.7/11.8

Approvals

170

D

315

LRA (rated after 4 sec. UL984) LST/HST

Height

127 165 186 218

37°

37°

107

80 CD.44.P4.02

CK.40.B7.02

107 115

55 63

Motor size

70 150

1300 1510

55

Weight without electrical equipment

g cm3

127 101.6 35

Free gas vol. in compressor

12.87

151

Maximum refrigerant charge

ø19 ø9.7

8264

1

August 2003

Capacity (EN 12900/CECOMAF) Evap. temp in °C -35 SC12G, 50Hz 64.6 SC12G, 60Hz 74.2

watt

-30 113 131

-25 -23.3 -20 175 199 252 203 232 294

-15 348 406

-10 464 542

-5 603 704

0 768

5 7.2 10 15 960 1054 1182 1437

-30 140 162

-25 -23.3 -20 216 246 312 251 286 363

-15 430 501

-10 574 670

-5 746 872

0 5 7.2 10 15 951 1191 1308 1469 1790

c

Capacity (ASHRAE) Evap. temp in °C -35 SC12G, 50Hz 79.6 SC12G, 60Hz 91.5

HST

watt b 8222

a2

Power consumption Evap. temp in °C -35 SC12G, 50Hz 148 SC12G, 60Hz 172

watt -30 187 218

-25 -23.3 -20 227 241 268 265 281 313

-15 311 363

-10 355 415

-5 400 468

0 446

5 493

7.2 514

10 541

d

15 589

c

Current consumption

A

Evap. temp in °C -35 -30 -25 -23.3 -20 -15 -10 -5 0 5 7.2 10 15 SC12G, 50Hz 1.63 1.72 1.83 1.87 1.95 2.09 2.24 2.40 2.57 2.76 2.85 2.96 3.17 SC12G, 60Hz 1.79 1.89 2.01 2.06 2.15 2.30 2.46 2.64

COP (EN 12900/CECOMAF)

12

13 14

W/W

Evap. temp in °C -35 -30 -25 -23.3 -20 -15 SC12G, 50Hz 0.44 0.61 0.77 0.83 0.94 1.12 SC12G, 60Hz 0.43 0.60 0.77 0.83 0.94 1.12

-10 -5 0 5 7.2 10 15 1.31 1.51 1.72 1.95 2.05 2.19 2.44 1.31 1.51

COP (ASHRAE)

Start winding Main winding Winding protector

W/W

Evap. temp in °C -35 -30 -25 -23.3 -20 -15 -10 -5 0 5 7.2 10 15 SC12G, 50Hz 0.54 0.75 0.95 1.02 1.16 1.38 1.62 1.87 2.13 2.42 2.55 2.72 3.04 SC12G, 60Hz 0.53 0.74 0.95 1.02 1.16 1.38 1.61 1.86 Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature 50Hz: Fan cooling F 2, 220V 60Hz: Fan cooling F 2, 220V

11

10

EN 12900/CECOMAF 55°C 32°C 55°C

ASHRAE 55°C 32°C 32°C

LST

b 8221

a1 d Main winding

a1

Start winding

N

Accessories Devices

Fig.

SC12G

a1

103N0002

Starting relay

a2

117U6003

Cover

b

103N2009

Starting capacitor 80 µF

c

117U5017

Cord relief

d

103N1004

PTC starting device

6.3 mm spades

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

N

C

L

Winding protector

118-1917 118-1918 118-1919

CD.44.P4.02

CK.40.B7.02

August 2003

171

SC15G Universal Compressor R134a 220-240V 50Hz Data Sheet (Replaces CD.44.K5.02) General SC15G

Code number

104G8520

Code number

104G8525

Code number compressor with oil cooler

104G8530

104G

SC15G Application

R134a

Blue stripe Approvals

8520

Barcode on white background

Application Application Evaporating temperature range Voltage range

°C

-25 to 15

V/Hz

LBP: 187 - 254 /50 LBP: 198 - 254 /60

S O F1

HBP: 198 - 254 /50 Motor type

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

CSIR

Max. ambient temperature

°C

Comp. cooling at ambient temp.

DANFOSS COMPRESSORS

Yellow background

LBP/HBP

8286-2

Compressor

43

F2

32°C

LBP: O/F1

38°C

LBP: O/F1

43°C

LBP: O/F1

HBP: F2 HBP: F2 HBP: F2

204 178 170

ø16

Design Displacement

cm3

Oil quantity

cm3 550 (500 on comp. with oil cooler)

kg

13.1

Motor watt

385

LRA (rated after 4 sec. UL984) HST

A

14.8

Cut-in current HST

A

14.8

Resistance, main and start winding (25°C)



209 203

B1

183

F

100 10.2 ±0.09

10.2 ±0.09

Process connector

location/I.D. mm

D 6.2 ±0.09

6.2 ±0.09

6.5 ±0.09

6.2 ±0.09

6.5 ±0.09

Discharge connector

location/I.D. mm

E 6.2 ±0.09

Oil cooler

location/I.D. mm

F

6.2 ±0.09

63

C 10.2 ±0.09

August 2003

B2

255

location/I.D. mm

pcs.

15 53

A

Suction connector

Compressors on a pallet

30

104G8520 104G8525

B

B2

B A

B1

3

104G8530 mm

C E

EN 60335-2-34

Dimensions

172

D

5.0/13.7

Approvals

Height

127 165 186 218

37°

37°

107

80 CD.44.K6.02

CK.40.B7.02

107 115

55 63

Motor size

70 150

1300 1410

55

Weight without electrical equipment

g cm3

127 101.6 35

Free gas vol. in compressor

15.28

151

Maximum refrigerant charge

ø19 ø9.7

8264

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C SC15G

-25 164

-23.3 206

-20 290

-15 424

watt -10 568

-5 728

0 908

5 7.2 10 15 1110 1207 1340 1600 c

Capacity (ASHRAE) Comp.\°C SC15G

-25 203

-23.3 255

watt -20 358

-15 523

-10 703

-5 901

0 5 7.2 10 15 1124 1377 1499 1665 1993 b 8222

Power consumption Comp.\°C SC15G

-25 233

-23.3 259

watt -20 307

-15 376

-10 440

-5 497

0 549

5 595

7.2 613

10 634

15 667

a2 d

Current consumption Comp.\°C SC15G

A

-25 -23.3 -20 2.21 2.28 2.40

-15 2.59

-10 2.78

-5 2.99

0 3.20

5 3.42

7.2 3.52

10 3.64

15 3.88

c 11

10

COP (EN 12900/CECOMAF) Comp.\°C SC15G

-25 -23.3 -20 0.71 0.80 0.95

W/W -15 1.13

-10 1.29

-5 1.46

0 1.65

5 1.87

7.2 1.97

10 2.11

-15 1.39

-10 1.60

-5 0 1.81 2.05

5 2.31

7.2 2.44

10 2.62

COP (ASHRAE) Comp.\°C SC15G

-25 -23.3 -20 0.87 0.99 1.17

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Fan cooling F2, 220V 50Hz

15 2.40

12

13 14

W/W

EN 12900/CECOMAF 55°C 32°C 55°C

15 2.99

Start winding Main winding Winding protector

ASHRAE 55°C 32°C 32°C

Accessories Devices

Fig.

SC15G

Starting relay

a2

117U6005

Cover

b

103N2009

Starting capacitor 80 µF

c

117U5017

Cord relief

d

103N1004

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

118-1917 118-1918 118-1919

CD.44.K6.02

CK.40.B7.02

August 2003

173

SC18G Universal Compressor R134a 220-240V 50Hz Data Sheet (Replaces CD.44.V2.02) General SC18G

Code number

104G8820

Code number

104G8822

Code number compressor with oil cooler

104G8830

104G

SC18G Application

R134a

Blue stripe Approvals

8820

Barcode on white background

Application Application Evaporating temperature range Voltage range

°C

-35 to 15

V/Hz

LBP: 187 - 254 /50 LBP: 198 - 254 /60

S O F1

HBP: 198 - 254 /50 Motor type

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

CSIR

Max. ambient temperature

°C

Comp. cooling at ambient temp.

DANFOSS COMPRESSORS

Yellow background

LBP/HBP

8286-8

Compressor

43

F2

32°C

LBP: O/F1

38°C

LBP: O/F1

43°C

LBP: O/F1

HBP: F2 HBP: F2 HBP: F2

204 178 170

ø16

Design Displacement

cm 3

Oil quantity

cm 3 550 (500 on comp. with oil cooler)

kg

13.7

Motor watt

495

LRA (rated after 4 sec. UL984) HST

A

18.6

Cut-in current HST

A

18.6

Resistance, main and start winding (25°C)



219 213

B1

193

F

110 8.2 ±0.09

10.2 ±0.09

Process connector

location/I.D. mm

D 6.2 ±0.09

6.2 ±0.09

6.5 ±0.09

6.2 ±0.09

6.5 ±0.09

Discharge connector

location/I.D. mm

E 6.2 ±0.09

Oil cooler

location/I.D. mm

F

6.2 ±0.09

63

C 8.2 ±0.09

August 2003

B2

255

location/I.D. mm

pcs.

15

53

A

Suction connector

Compressors on a pallet

30

104G8820 104G8822

B

B2

B A

B1

3

104G8830 mm

C E

EN 60335-2-34, CCIB

Dimensions

174

D

3.7/14.1

Approvals

Height

127 165 186 218

37°

37°

107

80 CD.44.V3.02

CK.40.B7.02

107 115

55 63

Motor size

70 150

1300 1460

55

Weight without electrical equipment

g cm3

127 101.6 35

Free gas vol. in compressor

17.69

151

Maximum refrigerant charge

ø19 ø9.7

8264

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C SC18G

-25 283

-23.3 318

-20 394

-15 526

watt -10 684

-5 870

0 5 7.2 10 15 1087 1337 1459 1624 1950 c

Capacity (ASHRAE) Comp.\°C SC18G

-25 348

-23.3 392

watt -20 485

-15 649

-10 844

-5 0 5 7.2 10 15 1074 1343 1655 1807 2014 2423 b 8222

Power consumption Comp.\°C SC18G

-25 331

-23.3 351

watt -20 389

-15 448

-10 507

-5 568

0 630

5 695

7.2 725

10 763

15 835

a2 d

Current consumption Comp.\°C SC18G

A

-25 -23.3 -20 2.56 2.62 2.72

-15 2.88

-10 3.05

-5 3.24

0 3.46

5 3.71

7.2 3.84

10 4.00

15 4.34

c 11

10

COP (EN 12900/CECOMAF) Comp.\°C SC18G

-25 -23.3 0.86 0.91

W/W

-20 1.01

-15 1.18

-10 1.35

-5 1.53

0 1.72

5 1.92

7.2 2.01

10 2.13

-25 -23.3 -20 1.05 1.12 1.25

-15 1.45

-10 1.67

-5 1.89

0 2.13

5 2.38

7.2 2.49

10 2.64

COP (ASHRAE) Comp.\°C SC18G

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Fan cooling, 220V 50Hz

15 2.34

12

13 14

W/W

EN 12900/CECOMAF 55°C 32°C 55°C

15 2.90

Start winding Main winding Winding protector

ASHRAE 55°C 32°C 32°C

Accessories Devices

Fig.

SC18G

Starting relay

a2

117U6019

Cover

b

103N2009

Starting capacitor 80 µF

c

117U5017

Cord relief

d

103N1004

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

118-1917 118-1918 118-1919

CD.44.V3.02

CK.40.B7.02

August 2003

175

SC21G Universal Compressor R134a 220-240V 50Hz Data Sheet (Replaces CD.44.L6.02) General SC21G 104G8140

Code number

104G8124

Code number (UL-recognized)

104G8143

Application

R134a

Blue stripe Approvals

8140

Barcode on white background

Application Application

LBP/HBP °C

R

-35 to 15

V/Hz

LBP: 187 - 254 /50

SC21G 230V-60Hz 1PH

LBP: 198 - 254 /60 HBP: 198 - 254 /50 Motor type

CSR

Max. ambient temperature

°C

Comp. cooling at ambient temp.

THERMALLY PROTECTED

43

32°C

Approval mark

LBP: F2 S O F1

HBP: F2 38°C

LBP: F2 HBP: F2

43°C

F2

LBP: F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

HBP: F2

cm 3

Free gas vol. in compressor Weight without electrical equipment

550

g

1300

cm3

1460

kg

13.5

Motor Motor size

watt

550

LRA (rated after 4 sec. UL984) HST

A

21.8

Cut-in current HST

A

21.8

Resistance, main and start winding (25°C) Ω

176

B A

B1

UL984/CSA-C22.2

219

B

213

B1

193

B2

110

Suction connector

location/I.D. mm

C 10.2 ±0.09

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

6.2 ±0.09

pcs.

104G8124

255

10.2 ±0.09

63

A

3

104G8140/43 mm

B2

151

Dimensions

August 2003

C E

EN 60335-2-34

Approvals (104G8143)

Compressors on a pallet

127 165 186 218

D

3.5/12.1

Approvals (104G8140/24)

Height

ø19 ø9.7

70 150

Maximum refrigerant charge

55

Displacement Oil quantity

204 178 170

ø16

*) Not applicable below -25°C evaporating temperature in 43°C ambient temperature above 240V. cm 3 20.95

127 101.6 35

Design

8286-9

)

DANFOSS COMPRESSORS

Yellow background

37°

37°

55 63

Evaporating temperature range Voltage range*

104G

SC21G

Code number

8286-3

Compressor

6.5 ±0.09 6.5 ±0.09 80 CD.44.L7.02

CK.40.B7.02

107

107 115

8257

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C SC21G

-25 333

-23.3 370

-20 453

-15 606

watt -10 792

-5 0 5 7.2 10 15 1012 1268 1560 1700 1889 2256

Capacity (ASHRAE) Comp.\°C SC21G

-25 410

-23.3 456

a3 a2

watt -20 558

-15 746

-10 977

e

-5 0 5 7.2 10 15 1250 1568 1931 2106 2343 2803

c 8227

Power consumption Comp.\°C SC21G

-25 382

-23.3 404

watt -20 445

-15 509

-10 575

-5 643

0 714

5 789

7.2 823

10 868

15 953

-25 -23.3 -20 2.28 2.34 2.48

-15 2.71

-10 2.96

-5 3.24

0 3.54

5 3.87

7.2 4.02

10 4.22

15 4.60

Current consumption Comp.\°C SC21G

COP (EN 12900/CECOMAF) Comp.\°C SC21G

-25 -23.3 -20 0.87 0.92 1.02

W/W -15 1.19

-10 1.38

-5 1.58

0 1.78

5 1.98

7.2 2.07

10 2.18

COP (ASHRAE) Comp.\°C SC21G

-25 -23.3 -20 1.07 1.13 1.25

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Fan cooling, 220V 50Hz

d

A

15 2.37

b e

Start winding 5

2

4

1

a2

Main winding Winding protector 1

1

2 N L

2 N L

Bleeder resistance

c

a3

W/W -15 1.47

-10 1.70

-5 1.95

EN 12900/CECOMAF 55°C 32°C 55°C

0 2.20

5 2.45

7.2 2.56

10 2.70

15 2.94

M

Thermostat

Fan

ASHRAE 55°C 32°C 32°C

Accessories Devices

Fig.

SC21G

a3

117-7028 (470 mm cable length) 117-7029 (550 mm cable length) 117-7032 (650 mm cable length)

a3

117-7038 (470 mm cable length) 117-7039 (550 mm cable length) 117-7043 (1000 mm cable length)

Starting device (104G8140/24)

Starting device (104G8143)

Cover (104G8140/24)

b

103N2009

Cover (104G8143)

b

103N2008

Starting relay

a2

Starting capacitor

c

Run capacitor

e

Cord relief

d

Components of starting device 103N1004

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

118-1917 118-1918 118-1919

2

CD.44.L7.02

August 2003

CK.40.B7.02

August 2003

177

SC12/12G Universal Twin Compressor R134a 220-240V 50Hz Data Sheet (Replaces CD.44.F6.02) General SC12/12G

Code number

104G8280

Application Application

LBP/HBP

Evaporating temperature range Voltage range

°C

-35 to 15

V/Hz

104G

SC12/12G Application

R134a

Blue stripe Approvals

8280

Barcode on white background

8288

Compressor

DANFOSS COMPRESSORS

Yellow background

198 - 254 /50

Motor type

CSIR

Max. ambient temperature

°C

Comp. cooling at ambient temp.

43

32°C

S O F1

LBP: F2 HBP: F2

38°C

LBP: F2

F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

HBP: F2 43°C

LBP: F2

127

HBP: F2

Displacement

cm3

2 x 12.87

Oil quantity

cm3

1120

Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment

g

2200

cm3

3020

kg

28

100

Design

127 ø16

175

D

302

C

Motor Motor size

watt

2 x 315

LRA (rated after 4 sec. UL984) HST*

A

Cut-in current HST*

A

12.6 12.6

Resistance, main and start winding (25°C)



6.7/11.8

Approvals

A

B

B1

EN 60335-2-34 B2

* Operational current for the second compressor time-delayed.

Dimensions Height

mm

A

249

B

244

B1

183

B2

100

12

1"-14 UNF

8260

E

Service valve

location/I.D. mm

C

Solder connector

location/I.D. mm

C

12

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

6.2 ±0.09

Compressors on a pallet

pcs.

320

Suction connector

18 326

August 2003

178

CD.44.F7.02

CK.40.B7.02

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C SC12/12G

-35 129

watt

-30 226

-25 350

-23.3 399

-20 505

-15 696

-10 928

-5 1206

0 1535

5 1920

7.2 2108

10 2364

15 2875

-30 279

-25 432

-23.3 492

-20 623

-15 860

-10 1147

-5 1493

0 1902

5 2382

7.2 2617

10 2939

15 3580

-30 373

-25 454

-23.3 481

-20 537

-15 622

-10 710

-5 800

0 892

5 986

7.2 1028

10 1081

15 1177

-30 3.44

-25 3.66

-23.3 3.74

-20 3.90

-15 4.17

-10 4.47

-5 4.79

0 5.14

5 5.52

7.2 5.69

10 5.92

15 6.35

-30 0.61

-25 0.77

-23.3 0.83

-20 0.94

-15 1.12

-10 1.31

-5 1.51

0 1.72

5 1.95

7.2 2.05

10 2.19

15 2.44

-30 0.75

-25 0.95

-23.3 1.02

-20 1.16

-15 1.38

-10 1.62

-5 1.87

0 2.13

5 2.42

7.2 2.55

10 2.72

15 3.04

Capacity (ASHRAE) Comp.\°C SC12/12G

-35 159

watt

Power consumption Comp.\°C SC12/12G

-35 296

watt

Current consumption Comp.\°C SC12/12G

-35 3.25

A

COP (EN 12900/CECOMAF) Comp.\°C SC12/12G

-35 0.44

W/W

COP (ASHRAE) -35 0.54

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Fan cooling F2, 220V 50Hz

EN 12900/CECOMAF 55°C 32°C 55°C

ASHRAE 55°C 32°C 32°C

Starting relay Starting capacitor 10 11 12

10 11 13

Main winding 14

1 2 N L

Accessories Devices

pcs.

SC12/12G

Starting relay

2

117U6003

Starting capacitor 80 µF

2

117U5017

1 2 N L

1 2 N L

2 1

Cover

2

103N2009

Cord relief

2

103N1004

Time-delay relay Check valve (to be used with time-delay relay)

1 2

117N0001 020-1014

Service valve

1

118-7350 (12 mm)

Solder connector (alternative)

1

104B0584 (12 mm)

Start winding Winding protector

Thermostat

12

13

14

1933

Comp.\°C SC12/12G

1 2 N L

Blue Black Brown

3

M

Time delay relay Thermostat 2

Fan

Safety pressure control Remove wire L-1 if time delay is used

Remove wire 1-2 if thermostat 2 is used

service valve seal ring

seal ring

Seal ring for service valve and solder connector

1

118-3638 8214

Mounting accessories Bolt joint for one compressor Bolt joint in quantities

2

August 2003

2

solder connector

118-1917 118-1918

CD.44.F7.02

CK.40.B7.02

August 2003

179

SC15/15G Universal Twin Compressor R134a 220-240V 50Hz Data Sheet (Replaces CD.44.R3.02) General SC15/15G

Code number

104G8580

Application Application

LBP/HBP

Evaporating temperature range Voltage range

°C

-25 to 15

V/Hz

104G

SC15/15G Application

R134a

Blue stripe Approvals

8580

Barcode on white background

8288-3

Compressor

DANFOSS COMPRESSORS

Yellow background

198 - 254 /50

Motor type

CSIR

Max. ambient temperature

°C

Comp. cooling at ambient temp.

43

32°C

S O F1

LBP: F2 HBP: F2

38°C

LBP: F2

F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

HBP: F2 43°C

LBP: F2

127

HBP: F2

Displacement

cm3

2 x 15.28

Oil quantity

cm3

1120

Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment

g

2200

cm3

2820

kg

28

100

Design

127 ø16

175

D

302

C

Motor Motor size

watt

2 x 385

LRA (rated after 4 sec. UL984) HST*

A

Cut-in current HST*

A

14.8 14.8

Resistance, main and start winding (25°C)



5.0/13.7

Approvals

A

B

B1

EN 60335-2-34 B2

* Operational current for the second compressor time-delayed.

Dimensions Height

mm

A

249

B

244

B1

183

B2

100

12

1"-14 UNF

8260

E

Service valve

location/I.D. mm

C

Solder connector

location/I.D. mm

C

12

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

6.2 ±0.09

Compressors on a pallet

pcs.

320

Suction connector

18 326

August 2003

180

CD.44.R4.02

CK.40.B7.02

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C SC15/15G

-25 328

watt

-23.3 413

-20 581

-15 847

-10 1137

-5 1457

0 1815

5 2220

7.2 2415

10 2679

15 3201

-23.3 510

-20 717

-15 1047

-10 1405

-5 1803

0 2249

5 2754

7.2 2998

10 3330

15 3986

-23.3 517

-20 614

-15 752

-10 879

-5 995

0 1099

5 1190

7.2 1226

10 1269

15 1335

-23.3 4.55

-20 4.79

-15 5.17

-10 5.57

-5 5.98

0 6.40

5 6.84

7.2 7.03

10 7.29

15 7.75

Capacity (ASHRAE) Comp.\°C SC15/15G

-25 405

watt

Power consumption Comp.\°C SC15/15G

-25 465

watt

Current consumption Comp.\°C SC15/15G

-25 4.43

A

COP (EN 12900/CECOMAF) Comp.\°C SC15/15G

W/W

-25 0.71

-23.3 0.80

-20 0.95

-15 1.13

-10 1.29

-5 1.46

0 1.65

5 1.87

7.2 1.97

10 2.11

15 2.40

-25 0.87

-23.3 0.99

-20 1.17

-15 1.39

-10 1.60

-5 1.81

0 2.05

5 2.31

7.2 2.44

10 2.62

15 2.99

COP (ASHRAE)

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Fan cooling F2, 220V 50Hz

EN 12900/CECOMAF 55°C 32°C 55°C

ASHRAE 55°C 32°C 32°C

Starting relay Starting capacitor 10 11 12

10 11 13

Main winding 14

1 2 N L

Accessories Devices

pcs.

SC15/15G

Starting relay

2

117U6005

Starting capacitor 80 µF

2

117U5017

1 2 N L

1 2 N L

2 1

Cover

2

103N2009

Cord relief

2

103N1004

Time-delay relay Check valve (to be used with time-delay relay)

1 2

117N0001 020-1014

Service valve

1

118-7350 (12 mm)

Solder connector (alternative)

1

104B0584 (12 mm)

Start winding Winding protector

Thermostat

12

13

14

1933

Comp.\°C SC15/15G

1 2 N L

Blue Black Brown

3

M

Time delay relay Thermostat 2

Fan

Safety pressure control Remove wire L-1 if time delay is used

Remove wire 1-2 if thermostat 2 is used

service valve seal ring

seal ring

Seal ring for service valve and solder connector

1

118-3638 8214

Mounting accessories Bolt joint for one compressor Bolt joint in quantities

2

August 2003

2

solder connector

118-1917 118-1918

CD.44.R4.02

CK.40.B7.02

August 2003

181

SC18/18G Universal Twin Compressor R134a 220-240V 50Hz Data Sheet (Replaces CD.44.U2.02) General SC18/18G

Code number

104G8880

Application Application Evaporating temperature range Voltage range

°C V/Hz

R134a

LBP/HBP

Blue stripe Approvals

-35 to 15

Barcode on white background

198 - 254 /50

Motor type

104G

SC18/18G Application

8880

8288-4

Compressor

DANFOSS COMPRESSORS

Yellow background

CSIR

Max. ambient temperature

°C

Comp. cooling at ambient temp.

43

32°C

S O F1

LBP: F2 HBP: F2

38°C

LBP: F2

F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

HBP: F2 43°C

LBP: F2

127

HBP: F2

Displacement

cm 3

2 x 17.69

Oil quantity

cm 3

1120

Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment

g

2200

cm3

2920

kg

28

100

Design

127 ø16

175

D

302

C

Motor Motor size

watt

2 x 495

LRA (rated after 4 sec. UL984) HST*

A

Cut-in current HST*

A

18.6 18.6

Resistance, main and start winding (25°C)



3.7/14.1

Approvals

A

B

B1

EN 60335-2-34, CCIB B2

* Operational current for the second compressor time-delayed.

Dimensions Height

mm

A

259

B

254

B1

193

B2

110

1"-14 UNF

8260

E

Service valve

location/I.D. mm

C

16

Solder connector

location/I.D. mm

C

16

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

6.2 ±0.09

Compressors on a pallet

pcs.

320

Suction connector

18 326

August 2003

182

CD.44.U3.02

CK.40.B7.02

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C SC18/18G

-25 566

watt

-23.3 636

-20 788

-15 1052

-10 1368

-5 1740

0 2174

5 2674

7.2 2918

10 3248

15 3900

-23.3 784

-20 970

-15 1298

-10 1688

-5 2148

0 2686

5 3310

7.2 3614

10 4028

15 4846

-23.3 702

-20 778

-15 896

-10 1014

-5 1136

0 1260

5 1390

7.2 1450

10 1526

15 1670

-23.3 5.24

-20 5.44

-15 5.76

-10 6.10

-5 6.48

0 6.92

5 7.42

7.2 7.68

10 8.00

15 8.68

Capacity (ASHRAE) Comp.\°C SC18/18G

-25 696

watt

Power consumption Comp.\°C SC18/18G

-25 662

watt

Current consumption Comp.\°C SC18/18G

-25 5.12

A

COP (EN 12900/CECOMAF) Comp.\°C SC18/18G

W/W

-25 0.86

-23.3 0.91

-20 1.01

-15 1.18

-10 1.35

-5 1.53

0 1.72

5 1.92

7.2 2.01

10 2.13

15 2.34

-25 1.05

-23.3 1.12

-20 1.25

-15 1.45

-10 1.67

-5 1.89

0 2.13

5 2.38

7.2 2.49

10 2.64

15 2.90

COP (ASHRAE)

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Fan cooling, 220V 50Hz

EN 12900/CECOMAF 55°C 32°C 55°C

ASHRAE 55°C 32°C 32°C

Starting relay Starting capacitor 10 11 12

10 11 13

Main winding 14

1 2 N L

Accessories Devices

pcs.

SC18/18G

Star ting relay

2

117U6019

Star ting capacitor 80 µF

2

117U5017

Start winding Winding protector

1 2 N L

1 2 N L

2 1

Thermostat

12

13

14

1933

Comp.\°C SC18/18G

1 2 N L

Blue Black Brown

3

M

Time delay relay Thermostat 2

Fan

Safety pressure control

Cover

2

103N2009

Cord relief

2

103N1004

Time-delay relay Check valve (to be used with time-delay relay)

1 2

117N0001 020-1014

Service valve

1

118-7351 (16 mm)

Solder connector (alternative)

1

118-7405 (16 mm)

Remove wire L-1 if time delay is used

Remove wire 1-2 if thermostat 2 is used

service valve seal ring

seal ring

Seal ring for service valve and solder connector

1

118-3638 8214

Mounting accessories Bolt joint for one compressor Bolt joint in quantities

2

August 2003

2

solder connector

118-1917 118-1918

CD.44.U3.02

CK.40.B7.02

August 2003

183

SC21/21G Universal Twin Compressor R134a 220-240V 50Hz Data Sheet (Replaces CD.44.J4.02) General SC21/21G

Code number

104G8180

R134a

Blue stripe Approvals

Application Application Evaporating temperature range Voltage range*)

°C V/Hz

8180

LBP/HBP

Barcode on white background

-35 to 15

Yellow background

DANFOSS COMPRESSORS

198 - 254 /50

Motor type

CSR

Max. ambient temperature Comp. cooling at ambient temp.

°C

43

32°C

F2

38°C

F2

43°C

F2

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

Displacement

cm3

2 x 20.95

Oil quantity

cm3

1120

g

2200

3

2920

Maximum refrigerant charge Free gas vol. in compressor

cm

Weight without electrical equipment

kg

127

*) Not applicable below -25°C evaporating temperature in 43°C ambient temperature above 240V.

28

100

Design

104G

SC21/21G Application

8288-2

Compressor

127

Motor

ø16

Motor size

watt

LRA (rated after 4 sec. UL984) HST*

A

175

D

2 x 550

302

C

21.8

Cut-in current HST*

A

21.8

Resistance, main and start winding (25°C)



3.5/12.1

Approvals

EN 60335-2-34 * Operational current for the second compressor time-delayed.

Dimensions Height

A

B

B1 B2

mm

A

259

B

254

B1

193

B2

110

16

1"-14 UNF

8265

E

Service valve

location/I.D. mm

C

Solder connector

location/I.D. mm

C

16

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

6.2 ±0.09

Compressors on a pallet

pcs.

320

Suction connector

18

326

August 2003

184

CD.44.J5.02

CK.40.B7.02

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C SC21/21G

-25 667

watt

-23.3 741

-20 907

-15 1212

-10 1584

-5 2025

0 2536

5 3120

7.2 3400

10 3778

15 4511

-23.3 912

-20 1116

-15 1493

-10 1953

-5 2500

0 3135

5 3862

7.2 4212

10 4684

15 5605

-23.3 815

-20 899

-15 1026

-10 1156

-5 1289

0 1430

5 1581

7.2 1651

10 1744

15 1921

-23.3 4.68

-20 4.96

-15 5.42

-10 5.92

-5 6.48

0 7.08

5 7.74

7.2 8.04

10 8.44

15 9.20

Capacity (ASHRAE) Comp.\°C SC21/21G

-25 820

watt

Power consumption Comp.\°C SC21/21G

-25 771

watt

Current consumption Comp.\°C SC21/21G

-25 4.56

A

COP (EN 12900/CECOMAF) Comp.\°C SC21/21G

W/W

-25 0.87

-23.3 0.92

-20 1.02

-15 1.19

-10 1.38

-5 1.58

0 1.78

5 1.98

7.2 2.07

10 2.18

15 2.37

-25 1.07

-23.3 1.13

-20 1.25

-15 1.47

-10 1.70

-5 1.95

0 2.20

5 2.45

7.2 2.56

10 2.70

15 2.94

COP (ASHRAE)

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Fan cooling, 220V 50Hz

EN 12900/CECOMAF 55°C 32°C 55°C

ASHRAE 55°C 32°C 32°C

Winding protector Starting capacitor Main winding Starting relay Run capacitor Start winding Bleeder resistance

1 2 N L

Accessories Devices

pcs.

SC21/21G

2

117-7028 (470 mm cable length) 117-7029 (550 mm cable length) 117-7032 (650 mm cable length)

Star ting device

Cover

2

103N2009

Cord relief

2

103N1004

Time-delay relay Check valve (to be used with time-delay relay)

1 2

117N0001 020-1014

5

2

5

2

4

1

4

1

1 2 N L

1 2 N L

2 1

Thermostat

1932

Comp.\°C SC21/21G

1 2 N L

Blue Black Brown

3

M

Time delay relay Safety pressure control

Remove wire L-1 if time delay is used

Fan

Thermostat 2

Remove wire 1-2 if thermostat 2 is used

service valve seal ring

Service valve

1

118-7351 (16 mm)

Solder connector (alternative)

1

118-7405 (16 mm)

Seal ring for service valve and solder connector

1

118-3638

seal ring

8214

Mounting accessories Bolt joint for one compressor Bolt joint in quantities

2

August 2003

2

solder connector

118-1917 118-1918

CD.44.J5.02

CK.40.B7.02

August 2003

185

TL4GH Heat Pump Compressor R134a 220-240V 50/60Hz Data Sheet (Replaces CD.42.P4.02) General TL4GH

Code number

102G4455

102G

TL4GH Application

R134a

Blue stripe Approvals

Application Application Evaporating temperature range Voltage range

°C V/Hz

HBP

Barcode on white background

-15 to 15

Yellow background

4455

8289

Compressor

DANFOSS COMPRESSORS

198 - 254 /50

R

198 - 254 /60

TL4GH 230V-60Hz 1PH

CSIR

Max. ambient temperature Comp. cooling at ambient temp.

°C

43

32°C

F2

38°C

F2

43°C

F2

THERMALLY PROTECTED

Approval mark S O F1

Design Displacement Oil quantity

cm3

3.86

3

280

cm

Maximum refrigerant charge Free gas vol. in compressor

600 1690

kg

7.5

F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

ø16

35 70 100

Weight without electrical equipment

g cm3

8289-2

Motor type

Motor Motor size

watt

140

LRA (rated after 4 sec. UL984) HST

A

5.7

Cut-in current HST

A

5.7

Resistance, main and start winding (25°C)



14.5/14.8

Approvals

EN 60335-2-34, UL984/CSA-C22.2

ø9 170 178 186 204

C or D

E

Dimensions 173 169

C

6.2 ±0.09

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

5.0 +0.12/+0.20

Compressors on a pallet

pcs.

A B

105 107

B location/I.D. mm

30°

A

105

Suction connector

mm

° 31.5 28°

Height

D C

or

222 176

125

102

May 2001

186

CD.42.P5.02

CK.40.B7.02

71

29

51 20° °

45°

157 60.5 66

8263

96 117

1

August 2003

Capacity (EN 12900/CECOMAF) Evap. temp in °C TL4GH, 50Hz TL4GH, 60Hz

-15 104 118

watt

-10 140 160

-5 182 208

0 230 264

5 287 328

7.2 315 360

10 353 403

-10 173 198

-5 225 257

0 285 327

5 356 408

7.2 391 447

10 439 501

Capacity (ASHRAE) Evap. temp in °C TL4GH, 50Hz TL4GH, 60Hz

-15 129 146

-15 109 123

c

watt

Power consumption Evap. temp in °C TL4GH, 50Hz TL4GH, 60Hz

15 429 489

15 535 609

b

watt -10 121 139

-5 134 156

0 146 174

5 159 193

7.2 164 202

10 171 213

8219

15 181 232

a2 d

Current consumption Evap. temp in °C TL4GH, 50Hz TL4GH, 60Hz

-15 0.97 0.89

A -10 1.01 0.95

-5 1.05 1.02

0 1.09 1.09

5 1.12 1.16

7.2 1.14 1.19

10 1.16 1.23

15 1.20 1.31

c 11

10

COP (EN 12900/CECOMAF) Evap. temp in °C TL4GH, 50Hz TL4GH, 60Hz

W/W

-15 0.96 0.96

-10 1.16 1.15

-5 1.36 1.33

0 1.57 1.51

5 1.81 1.70

7.2 1.92 1.78

10 2.07 1.90

-15 1.18 1.19

-10 1.43 1.43

-5 1.68 1.65

0 1.95 1.88

5 2.24 2.11

7.2 2.38 2.22

10 2.57 2.36

COP (ASHRAE) Evap. temp in °C TL4GH, 50Hz TL4GH, 60Hz

15 2.37 2.11

12

13 14

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature 50Hz: Fan cooling F2, 220V 60Hz: Fan cooling F2, 220V

EN 12900/CECOMAF 55°C 32°C 55°C

15 2.95 2.63

Main winding

Winding protector Start winding

ASHRAE 55°C 32°C 32°C

Accessories Devices

Fig.

TL4GH

Starting relay

a2

117U6000

Cover

b

103N2011

Starting capacitor 60 µF

c

117U5014

Cord relief

d

103N1010

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

118-1917 118-1918 118-1919

CD.42.P5.02

CK.40.B7.02

May 2001

187

FR7GH Heat Pump Compressor R134a 220-240V 50/60Hz Data Sheet (Replaces CD.43.L4.02) General FR7GH

Code number

103G6683

Code number compressor with oil cooler

103G6692

103G

FR7GH Application

R134a

Blue stripe Approvals

6692

Barcode on white background

Application Application

HBP °C

DANFOSS COMPRESSORS

Yellow background

-15 to 15

V/Hz

R

198 - 254 /50

FR7GH 230V-60Hz 1PH

198 - 254 /60 Motor type

CSIR

Max. ambient temperature

°C

Comp. cooling at ambient temp.

43

32°C

O/F1

38°C

O/F1

THERMALLY PROTECTED

Approval mark

43°C

O/F1

S O F1

cm3

6.93

F2

Design Displacement Oil quantity

3

450

g

900

3

cm

1350

kg

10.6

watt

235

A

9.1

cm

Maximum refrigerant charge Free gas vol. in compressor

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

204 178

ø16

ø19

35 127 150

101.6 70 60.5

Weight without electrical equipment

8290-2

Evaporating temperature range Voltage range

8290

Compressor

Motor Motor size LRA (rated after 4 sec. UL984) HST Cut-in current HST

A

9.1

Resistance, main and start winding (25°C)



8.80/12.0

127 165 170 186 200

D

C E

EN 60335-2-34, UL984/CSA-C22.2

30°

30°

Approvals

ø9.7

location/I.D. mm

C

8.2 ±0.09

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

8.2 ±0.09

Oil cooler

location/I.D. mm

F

8.2 ±0.09

pcs.

80

102 130

243 264

122.5

May 2001

188

CD.43.L5.02

CK.40.B7.02

F 8266

55

Compressors on a pallet

34

Suction connector

40

191

24°

32 55

B

A B

40°

196

40°

A

127

mm

156

Height

25°

Dimensions

124.5 127.5

1

August 2003

Capacity (EN 12900/CECOMAF) Evap. temp in °C FR7GH, 50Hz FR7GH, 60Hz

-15 199 225

watt

-10 255 294

-5 327 379

0 417 482

5 525 607

7.2 580 668

10 655 753

-10 316 363

-5 405 469

0 516 598

5 652 753

7.2 720 830

10 814 936

15 807 924

Capacity (ASHRAE) Evap. temp in °C FR7GH, 50Hz FR7GH, 60Hz

-15 246 278

watt 15 1005 1151

Power consumption Evap. temp in °C FR7GH, 50Hz FR7GH, 60Hz

-15 165 184

c

b

watt -10 192 217

-5 217 251

0 239 284

5 258 317

7.2 266 331

10 274 350

8219

15 288 383

a2 d

Current consumption Evap. temp in °C FR7GH, 50Hz FR7GH, 60Hz

-15 1.38 1.31

A -10 1.47 1.41

-5 1.55 1.53

0 1.63 1.65

5 1.70 1.79

7.2 1.72 1.86

10 1.76 1.94

15 1.81 2.10

c 11

10

COP (EN 12900/CECOMAF) Evap. temp in °C FR7GH, 50Hz FR7GH, 60Hz

W/W

-15 1.21 1.22

-10 1.33 1.35

-5 1.51 1.51

0 1.74 1.70

5 2.04 1.91

7.2 2.18 2.02

10 2.39 2.15

-15 1.49 1.51

-10 1.64 1.67

-5 1.86 1.87

0 2.16 2.11

5 2.52 2.37

7.2 2.71 2.50

10 2.97 2.68

COP (ASHRAE) Evap. temp in °C FR7GH, 50Hz FR7GH, 60Hz

15 2.80 2.42

12

13 14

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature 50Hz: Oil or Fan cooling, 220V 60Hz: Oil or Fan cooling, 220V

EN 12900/CECOMAF 55°C 32°C 55°C

15 3.49 3.01

Main winding

Winding protector Start winding

ASHRAE 55°C 32°C 32°C

Accessories Devices

Fig.

FR7GH

Starting relay

a2

117U6016

Cover

b

103N2011

Starting capacitor 80 µF

c

117U5015

Cord relief

d

103N1010

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

118-1917 118-1918 118-1919

CD.43.L5.02

CK.40.B7.02

May 2001

189

SC10GH Heat Pump Compressor R134a 220-240V 50Hz Data Sheet (Replaces CD.44.D4.02) General SC10GH

Code number

104G8040

104G

SC10GH Application

R134a

Blue stripe Approvals

Application Application Evaporating temperature range Voltage range

°C V/Hz

HBP

Barcode on white background

-15 to 15

Yellow background

8040

DANFOSS COMPRESSORS

8291

Compressor

198 - 254 /50

Motor type

CSIR

Max. ambient temperature

°C

43

32°C

F1

38°C

F1

43°C

F1

Displacement

cm3

10.29

Oil quantity

cm3

500

g

1300

cm3

1510

kg

12.2

Comp. cooling at ambient temp.

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

Design

Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment

204 178 170

ø16

ø19 ø9.7

LRA (rated after 4 sec. UL984) HST

watt

250

A

10.8

Cut-in current HST

A

10.8

Resistance, main and start winding (25°C)



8.5/14.1

Approvals

EN 60335-2-34

70 150

Motor size

127 101.6 35

Motor

127 165 186 218

D

C

Dimensions

E A

199

B

193

B1

173

B2

90 10.2 ±0.09

Suction connector

location/I.D. mm

C

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

8.2 ±0.09

pcs.

B2

255

80 55

63

151

Compressors on a pallet

B A

B1

37°

37°

107

May 2001

190

CD.44.D5.02

CK.40.B7.02

107 115

55 63

mm

3

Height

8258

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C SC10GH

-15 259

-10 352

-5 467

watt 0 604

5 762

10 942

15 1144 c

Capacity (ASHRAE) Comp.\°C SC10GH

-15 319

-10 434

watt -5 577

0 746

5 943

10 1168

15 1421 b 8222

Power consumption Comp.\°C SC10GH

-15 245

-10 284

watt -5 323

0 359

5 392

10 421

15 443

a2 d

Current consumption Comp.\°C SC10GH

-15 1.65

-10 1.80

A -5 1.94

0 2.08

5 2.20

10 2.31

15 2.41

c 11

10

COP (EN 12900/CECOMAF) Comp.\°C SC10GH

-15 1.06

W/W

-10 1.24

-5 1.45

0 1.68

5 1.94

10 2.24

-10 1.53

-5 1.79

0 2.08

5 2.40

10 2.78

COP (ASHRAE) Comp.\°C SC10GH

-15 1.30

15 2.58

12

13 14

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Fan cooling, 220V 50Hz

EN 12900/CECOMAF 55°C 32°C 55°C

Start winding

15 3.21

Main winding Winding protector

ASHRAE 55°C 32°C 32°C

Accessories Devices

Fig.

SC10GH

Starting Relay

a2

117U6002

Cover

b

103N2009

Starting capacitor 80 µF

c

117U5017

Cord relief

d

103N1004

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

118-1917 118-1918 118-1919

CD.44.D5.02

CK.40.B7.02

May 2001

191

SC12GH Heat Pump Compressor R134a 220-240V 50Hz Data Sheet (Replaces CD.44.Q1.02) General SC12GH

Code number

104G8260

104G

SC12GH Application

R134a

Blue stripe Approvals

Application Application Evaporating temperature range Voltage range

°C V/Hz

HBP

Barcode on white background

-15 to 15

Yellow background

8260

8291-3

Compressor

DANFOSS COMPRESSORS

198 - 254 /50

Motor type

CSIR

Max. ambient temperature

°C

43

32°C

F1

38°C

F1

43°C

F1

Displacement

cm3

12.87

Oil quantity

cm3

500

g

1300

cm3

1510

kg

12.6

Comp. cooling at ambient temp.

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

Design

Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment

204 178 170

ø16

ø19 ø9.7

LRA (rated after 4 sec. UL984) HST

watt

315

A

12.6

Cut-in current HST

A

12.6

Resistance, main and start winding (25°C)



6.7/11.8

Approvals

EN 60335-2-34

70 150

Motor size

127 101.6 35

Motor

127 165 186 218

D

C

Dimensions

E A

209

B

203

B1

183

B2

100 10.2 ±0.09

Suction connector

location/I.D. mm

C

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

8.2 ±0.09

pcs.

B2

255

80 55

63

151

Compressors on a pallet

B A

B1

37°

37°

107

May 2001

192

CD.44.Q2.02

CK.40.B7.02

107 115

55 63

mm

3

Height

8258

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C SC12GH

-15 300

-10 415

-5 556

watt 0 723

5 915

10 1134

15 1378 c

Capacity (ASHRAE) Comp.\°C SC12GH

-15 370

-10 512

watt -5 686

0 893

5 1133

10 1406

15 1712 b 8222

Power consumption Comp.\°C SC12GH

-15 257

-10 316

watt -5 369

0 415

5 454

10 487

15 512

a2 d

Current consumption Comp.\°C SC12GH

-15 1.94

-10 2.15

A -5 2.33

0 2.50

5 2.65

10 2.78

15 2.89

c 11

10

COP (EN 12900/CECOMAF) Comp.\°C SC12GH

-15 1.17

W/W

-10 1.31

-5 1.51

0 1.74

5 2.02

10 2.33

-10 1.62

-5 1.86

0 2.15

5 2.49

10 2.89

COP (ASHRAE) Comp.\°C SC12GH

-15 1.44

15 2.69

12

13 14

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Fan cooling, 220V 50Hz

EN 12900/CECOMAF 55°C 32°C 55°C

Start winding

15 3.34

Main winding Winding protector

ASHRAE 55°C 32°C 32°C

Accessories Devices

Fig.

SC12GH

Starting Relay

a2

117U6003

Cover

b

103N2009

Starting capacitor 80 µF

c

117U5017

Cord relief

d

103N1004

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

118-1917 118-1918 118-1919

CD.44.Q2.02

CK.40.B7.02

May 2001

193

SC15GH Heat Pump Compressor R134a 220-240V 50Hz Data Sheet (Replaces CD.44.I4.02) General SC15GH

Code number

104G8560

Application Application

HBP

Evaporating temperature range Voltage range

°C

-15 to 15

V/Hz

104G

SC15GH Application

R134a

Blue stripe Approvals

8560

Barcode on white background

8291-4

Compressor

DANFOSS COMPRESSORS

Yellow background

198 - 254 /50

Motor type

CSIR

Max. ambient temperature Comp. cooling at ambient temp.

°C

43

32°C

F1

38°C

F1

43°C

F1

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

Design Displacement

cm3

Oil quantity

cm3

500

g

1300

cm3

1410

kg

13.5

Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment

15.28

204 178 170

ø16

ø19 ø9.7

LRA (rated after 4 sec. UL984) HST

watt

385

A

14.8

Cut-in current HST

A

14.8

Resistance, main and start winding (25°C)



5.0/13.7

Approvals

EN 60335-2-34

70 150

Motor size

127 101.6 35

Motor

127 165 186 218

D

C

Dimensions

E A

209

B

203

B1

183

B2

100 10.2 ±0.09

Suction connector

location/I.D. mm

C

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

8.2 ±0.09

pcs.

B2

255

80 55

63

151

Compressors on a pallet

B A

B1

37°

37°

107

May 2001

194

CD.44.I5.02

CK.40.B7.02

107 115

55 63

mm

3

Height

8258

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C SC15GH

-15 435

-10 573

-5 731

watt 0 916

5 1139

10 1407

15 1731 c

Capacity (ASHRAE) Comp.\°C SC15GH

-15 536

-10 707

watt -5 902

0 1133

5 1410

10 1745

15 2150 b 8222

Power consumption Comp.\°C SC15GH

-15 360

-10 424

watt -5 482

0 535

5 586

10 638

15 692

a2 d

Current consumption Comp.\°C SC15GH

-15 2.47

-10 2.64

A -5 2.83

0 3.04

5 3.26

10 3.48

15 3.70

c 11

10

COP (EN 12900/CECOMAF) Comp.\°C SC15GH

-15 1.21

W/W

-10 1.35

-5 1.52

0 1.71

5 1.94

10 2.21

-10 1.67

-5 1.87

0 2.12

5 2.41

10 2.74

COP (ASHRAE) Comp.\°C SC15GH

-15 1.49

15 2.50

12

13 14

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Fan cooling, 220V 50Hz

EN 12900/CECOMAF 55°C 32°C 55°C

Start winding

15 3.11

Main winding Winding protector

ASHRAE 55°C 32°C 32°C

Accessories Devices

Fig.

SC15GH

Starting relay

a2

117U6005

Cover

b

103N2009

Starting capacitor 80 µF

c

117U5017

Cord relief

d

103N1004

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

118-1917 118-1918 118-1919

CD.44.I5.02

CK.40.B7.02

May 2001

195

SC18GH Heat Pump Compressor R134a 220-240V 50Hz Data Sheet (Replaces CD.44.W1.02) General SC18GH

Code number

104G8860

104G

SC18GH Application

R134a

Blue stripe Approvals

Application Application Evaporating temperature range Voltage range

°C V/Hz

HBP

Barcode on white background

-15 to 15

Yellow background

8860

8291-2

Compressor

DANFOSS COMPRESSORS

198 - 254 /50

Motor type

CSIR

Max. ambient temperature

°C

43

32°C

F2

38°C

F2

43°C

F2

Displacement

cm3

17.69

Oil quantity

cm3

500

g

1300

cm3

1460

kg

13.7

Comp. cooling at ambient temp.

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

Design

Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment

204 178 170

ø16

ø19 ø9.7

LRA (rated after 4 sec. UL984) HST

watt

495

A

18.6

Cut-in current HST

A

18.6

Resistance, main and start winding (25°C)



3.7/14.1

Approvals

EN 60335-2-34

70 150

Motor size

127 101.6 35

Motor

127 165 186 218

D

C

Dimensions

E A

219

B

213

B1

193

B2

110 10.2 ±0.09

Suction connector

location/I.D. mm

C

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

8.2 ±0.09

pcs.

B2

255

80 55

63

151

Compressors on a pallet

B A

B1

37°

37°

107

May 2001

196

CD.44.W2.02

CK.40.B7.02

107 115

55 63

mm

3

Height

8258

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C SC18GH

-15 539

-10 676

-5 855

watt 0 1077

5 1340

10 1645

15 1990 c

Capacity (ASHRAE) Comp.\°C SC18GH

-15 664

-10 833

watt -5 1056

0 1331

5 1659

10 2039

15 2472 b 8222

Power consumption Comp.\°C SC18GH

-15 425

-10 498

watt -5 567

0 633

5 697

10 758

15 817

a2 d

Current consumption Comp.\°C SC18GH

-15 2.90

-10 3.13

A -5 3.36

0 3.60

5 3.85

10 4.11

15 4.38

c 11

10

COP (EN 12900/CECOMAF) Comp.\°C SC18GH

-15 1.27

W/W

-10 1.36

-5 1.51

0 1.70

5 1.92

10 2.17

-10 1.67

-5 1.86

0 2.10

5 2.38

10 2.69

COP (ASHRAE) Comp.\°C SC18GH

-15 1.56

15 2.44

12

13 14

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Fan cooling, 220V 50Hz

EN 12900/CECOMAF 55°C 32°C 55°C

Start winding

15 3.03

Main winding Winding protector

ASHRAE 55°C 32°C 32°C

Accessories Devices

Fig.

SC18GH

Starting relay

a2

117U6019

Cover

b

103N2009

Starting capacitor 80 µF

c

117U5017

Cord relief

d

103N1004

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

118-1917 118-1918 118-1919

CD.44.W2.02

CK.40.B7.02

May 2001

197

SC10GHH Heat Pump Compressor R134a 220-240V 50Hz Data Sheet (Replaces CD.44.E5.02) General SC10GHH

Code number compressor with oil cooler

104G8071

104G

SC10GHH Application

R134a

Blue stripe Approvals

Application Application Evaporating temperature range Voltage range

°C V/Hz

HBP

Barcode on white background

-15 to 15

Yellow background

8071

8293

Compressor

DANFOSS COMPRESSORS

198 - 254 /50

Motor type

CSR

Max. ambient temperature Comp. cooling at ambient temp.

°C

43

32°C

O

38°C

O

43°C

O

Displacement

cm3

10.29

Oil quantity

cm3

450

g

1300

cm3

1640

kg

13.3

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

Design

Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment

204 178 170

ø16

ø19 ø9.7

watt

240

LRA (rated after 4 sec. UL984) HST

A

8.9

Cut-in current HST

A

8.9

Resistance, main and start winding (25°C)



10.9/37.3

Approvals

EN 60335-2-34

70 150

Motor size

127 101.6 35

Motor

127 165 186 218

D

C

Dimensions

E 209

183

B2

100 10.2 ±0.09

Suction connector

location/I.D. mm

C

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

8.2 ±0.09

Oil cooler

location/I.D. mm

F

8.2 ±0.09

pcs.

80

30

198

CD.44.E6.02

CK.40.B7.02

B2

F

37°

37°

107

May 2001

15

255

55

Compressors on a pallet

B A

B1

53

203

B1

63

B

107 115

55 63

A

3

mm

151

Height

8259

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C SC10GHH

-15 259

-10 352

-5 467

watt 0 604

5 762

10 942

Capacity (ASHRAE) Comp.\°C SC10GHH

-15 319

-10 434

15 1144

a3 a2

watt -5 577

0 746

5 943

10 1168

e

15 1421

c 8227

Power consumption Comp.\°C SC10GHH

-15 230

-10 260

watt -5 290

0 318

5 345

10 371

15 395

-5 1.28

0 1.40

5 1.53

10 1.66

15 1.77

Current consumption Comp.\°C SC10GHH

-15 1.03

-10 1.15

COP (EN 12900/CECOMAF) Comp.\°C SC10GHH

-15 1.13

-10 1.35

-15 1.39

b

-5 1.61

0 1.90

5 2.21

10 2.54

e

Start winding 5

2

4

1

a2

Main winding

W/W

COP (ASHRAE) Comp.\°C SC10GHH

d

A

15 2.90

Winding protector 1

1

2 N L

2 N L

Bleeder resistance

c

a3

W/W -10 1.67

-5 1.99

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Fan cooling, 220V 50Hz

0 2.35

5 2.73

10 3.15

EN 12900/CECOMAF 55°C 32°C 55°C

15 3.60

M

Thermostat

Fan

ASHRAE 55°C 32°C 32°C

Accessories Devices Starting device

Fig.

SC10GHH

a3

117-7011 (470 mm cable length) 117-7014 (1000 mm cable length) 103N2009

Cover

b

Starting relay

a2

Starting capacitor

c

Run capacitor

e

Cord relief

d

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

Components of starting device 103N1004 118-1917 118-1918 118-1919

CD.44.E6.02

CK.40.B7.02

May 2001

199

SC15GHH Heat Pump Compressor R134a 220-240V 50Hz Data Sheet (CD.44.T1.02) General SC15GHH

Code number compressor with oil cooler

104G8571

104G

SC15GHH Application

R134a

Blue stripe Approvals

Application Application Evaporating temperature range Voltage range

°C V/Hz

HBP

Barcode on white background

-15 to 15

Yellow background

8571

8293-2

Compressor

DANFOSS COMPRESSORS

198 - 254 /50

Motor type

CSR

Max. ambient temperature Comp. cooling at ambient temp.

°C

43

32°C

O

38°C

O

43°C

O

Displacement

cm3

15.28

Oil quantity

cm3

450

g

1300

cm3

1540

kg

13.4

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

Design

Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment

204 178 170

ø16

ø19 ø9.7

LRA (rated after 4 sec. UL984) HST

watt

385

A

14.8

Cut-in current HST

A

14.8

Resistance, main and start winding (25°C)



5.0/13.7

Approvals

EN 60335-2-34

70 150

Motor size

127 101.6 35

Motor

127 165 186 218

D

C

Dimensions

E 209

183

B2

100 10.2 ±0.09

Suction connector

location/I.D. mm

C

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

8.2 ±0.09

Oil cooler

location/I.D. mm

F

8.2 ±0.09

pcs.

80

30

200

CD.44.T2.02

CK.40.B7.02

B2

F

37°

37°

107

May 2001

15

255

55

Compressors on a pallet

B A

B1

53

203

B1

63

B

107 115

55 63

A

3

mm

151

Height

8259

1

August 2003

Capacity (EN 12900/CECOMAF) Comp.\°C SC15GHH

-15 435

-10 570

-5 726

watt 0 911

5 1135

10 1405

Capacity (ASHRAE) Comp.\°C SC15GHH

-15 536

-10 703

15 1731

a3 a2

watt -5 896

0 1127

5 1405

10 1742

e

15 2150

c 8227

Power consumption Comp.\°C SC15GHH

-15 345

-10 377

watt -5 417

0 461

5 505

10 543

15 573

-5 2.01

0 2.20

5 2.39

10 2.56

15 2.70

Current consumption Comp.\°C SC15GHH

-15 1.71

-10 1.84

COP (EN 12900/CECOMAF) Comp.\°C SC15GHH

-15 1.26

-10 1.51

-5 1.74

-15 1.55

b

0 1.98

5 2.25

10 2.59

e

Start winding 5

2

4

1

a2

Main winding

W/W

COP (ASHRAE) Comp.\°C SC15GHH

d

A

15 3.02

Winding protector 1

1

2 N L

2 N L

Bleeder resistance

c

a3

W/W -10 1.87

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature Fan cooling, 220V 50Hz

-5 2.15

0 2.44

5 2.78

EN 12900/CECOMAF 55°C 32°C 55°C

10 3.21

15 3.75

M

Thermostat

Fan

ASHRAE 55°C 32°C 32°C

Accessories Devices

Fig.

SC15GHH

Starting device

a3

117-7012 (470 mm cable length) 103N2009

Cover

b

Starting relay

a2

Starting capacitor

c

Run capacitor

e

Cord relief

d

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

Components of starting device 103N1004 118-1917 118-1918 118-1919

CD.44.T2.02

CK.40.B7.02

May 2001

201

SC10GH Heat Pump Compressor R134a 220-240V 50/60Hz Data Sheet (Replaces CD.44.G6.02) General SC10GH

Code number

104G8041

104G

SC10GH Application

R134a

Blue stripe Approvals

Application Application Evaporating temperature range

°C

HBP

Barcode on white background

50Hz: -15 to 20

Yellow background

8041

DANFOSS COMPRESSORS

R

60Hz: -15 to 15 °C

50Hz: 70

SC10GH 230V-60Hz 1PH

60Hz: 60 / 70 short-term Voltage range

V/Hz

198 - 254 /50 198 - 254 /60

Motor type

THERMALLY PROTECTED

CSIR

Max. ambient temperature

°C

Comp. cooling at ambient temp.

Approval mark

43

32°C

F2

38°C

F2

43°C

F2

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

Design 10.29

Oil quantity

cm3

500

Maximum refrigerant charge

g

1300

cm3

1410

kg

12.2

watt

385

LRA (rated after 4 sec. UL984) HST

A

14.8

Cut-in current HST

A

Free gas vol. in compressor Weight without electrical equipment

204 178 170

ø16

Motor Motor size

127 165 186 218

D

C

14.8

Resistance, main and start winding (25°C) Ω Approvals

ø19 ø9.7

70 150

cm3

127 101.6 35

Displacement

8292-5

Condensing temperature max.

E

5.0/13.7 EN 60335-2-34, UL984/CSA-C22.2

B A

B1 B2

B2

90

location/I.D. mm

C

10.2 ±0.09

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

8.2 ±0.09

August 2002

pcs.

80

CD.44.G7.02

CK.40.B7.02

255

63

173

37°

37°

107

107 115

55 63

B1

55

199 193

151

A B

Suction connector

Compressors on a pallet

202

mm

3

Dimensions Height

8292

Compressor

8258

1

August 2003

Capacity (EN 12900/CECOMAF) Evap. temp in °C SC10GH, 50Hz SC10GH, 60Hz

-15 233 318

-10 352 421

-5 478 541

watt 0 613 683

5 762 849

7.2 832 930

10 927 1042

15 1113 1265

Capacity (ASHRAE) Evap. temp in °C SC10GH, 50Hz SC10GH, 60Hz

-15 288 393

20 1323 c

watt -10 435 520

-5 591 670

0 759 846

5 945 1053

7.2 1033 1155

10 1152 1295

15 1386 1575

20 1652 b 8222

Power consumption Evap. temp in °C SC10GH, 50Hz SC10GH, 60Hz

-15 235 287

watt -10 281 340

-5 323 392

0 361 444

5 395 496

7.2 409 518

10 426 545

15 453 593

20 476 d

Current consumption Evap. temp in °C SC10GH, 50Hz SC10GH, 60Hz

-15 2.34 2.13

a2

A -10 2.57 2.37

-5 2.80 2.63

0 3.03 2.90

5 3.26 3.18

7.2 3.36 3.30

10 3.48 3.46

15 3.70 3.76

20 3.92

c 11

10

COP (EN 12900/CECOMAF) Evap. temp in °C SC10GH, 50Hz SC10GH, 60Hz

W/W

-15 0.99 1.11

-10 1.25 1.24

-5 1.48 1.38

0 1.70 1.54

5 1.93 1.71

7.2 2.03 1.80

10 2.18 1.91

15 2.46 2.13

-15 1.22 1.37

-10 1.55 1.53

-5 1.83 1.71

0 2.11 1.90

5 2.39 2.13

7.2 2.53 2.23

10 2.71 2.37

15 3.06 2.66

COP (ASHRAE) Evap. temp in °C SC10GH, 50Hz SC10GH, 60Hz

20 2.78

12

13 14

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature 50Hz: Fan cooling F2, 220V 60Hz: Fan cooling F2, 220V

EN 12900/CECOMAF 55°C 32°C 55°C

20 3.47

Start winding Main winding Winding protector

ASHRAE 55°C 32°C 32°C

Accessories Devices

Fig.

SC10GH

Starting Relay

a2

117U6005 103N2008

Cover

b

Starting capacitor 80 µF

c

117U5019

Cord relief

d

103N1004

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

118-1917 118-1918 118-1919

CD.44.G7.02

CK.40.B7.02

August 2002

203

SC12GH Heat Pump Compressor R134a 220-240V 50/60Hz Data Sheet (Replaces CD.44.Z3.02) General SC12GH

Code number

104G8261

104G

SC12GH Application

R134a

Blue stripe Approvals

Application Application Evaporating temperature range

°C

HBP

Barcode on white background

50Hz: -10 to 20

Yellow background

8261

DANFOSS COMPRESSORS

R

60Hz: -15 to 15 °C

50Hz: 70

SC12GH 230V-60Hz 1PH

60Hz: 60 / 70 short-term Voltage range

V/Hz

198 - 254 /50 198 - 254 /60

Motor type

THERMALLY PROTECTED

CSIR

Max. ambient temperature

°C

Comp. cooling at ambient temp.

Approval mark

43

32°C

F2

38°C

F2

43°C

F2

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

Design 12.87

Oil quantity

cm3

500

Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment

g

1300

cm3

1510

kg

12.95

watt

470

A

19.7

204 178 170

ø16

Motor Motor size LRA (rated after 4 sec. UL984) HST Cut-in current HST

A

19.7

Resistance, main and start winding (25°C)



4.3/15.3

Approvals

ø19 ø9.7

70 150

cm3

127 101.6 35

Displacement

8292-6

Condensing temperature max.

127 165 186 218

D

C E

EN 60335-2-34, UL984/CSA-C22.2

B A

B1 B2

B2

100

location/I.D. mm

C

10.2 ±0.09

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

8.2 ±0.09

August 2002

pcs.

80

CD.44.Z4.02

CK.40.B7.02

255

63

183

37°

37°

107

107 115

55 63

B1

55

209 203

151

A B

Suction connector

Compressors on a pallet

204

mm

3

Dimensions Height

8292-3

Compressor

8258

1

August 2003

Capacity (EN 12900/CECOMAF) Evap. temp in °C SC12GH, 50Hz SC12GH, 60Hz

-15 371

-10 429 511

-5 577 680

watt 0 752 880

5 957 1116

7.2 1058 1233

10 1196 1393

15 1471 1714

Capacity (ASHRAE) Evap. temp in °C SC12GH, 50Hz SC12GH, 60Hz

-15 458

20 1787 c

watt -10 530 632

-5 715 841

0 932 1090

5 1188 1385

7.2 1313 1531

10 1486 1731

15 1832 2135

20 2231 b 8222

Power consumption Evap. temp in °C SC12GH, 50Hz SC12GH, 60Hz

-15 332

watt -10 356 389

-5 401 445

0 445 501

5 487 556

7.2 505 579

10 526 608

15 561 658

20 590 d

Current consumption Evap. temp in °C SC12GH, 50Hz SC12GH, 60Hz

-15 2.37

a2

A -10 3.08 2.61

-5 3.21 2.84

0 3.34 3.06

5 3.47 3.28

7.2 3.53 3.37

10 3.60 3.49

15 3.73 3.68

20 3.86

c 11

10

COP (EN 12900/CECOMAF) Evap. temp in °C SC12GH, 50Hz SC12GH, 60Hz

-15 1.12

W/W

-10 1.20 1.31

-5 1.44 1.53

0 1.69 1.76

5 1.97 2.01

7.2 2.10 2.13

10 2.27 2.29

15 2.62 2.60

-10 1.49 1.62

-5 1.78 1.89

0 2.09 2.17

5 2.44 2.49

7.2 2.60 2.64

10 2.82 2.85

15 3.27 3.24

COP (ASHRAE) Evap. temp in °C SC12GH, 50Hz SC12GH, 60Hz

20 3.03

12

13 14

W/W -15 1.38

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature 50Hz: Fan cooling F2, 220V 60Hz: Fan cooling F2, 220V

EN 12900/CECOMAF 55°C 32°C 55°C

20 3.78

Start winding Main winding Winding protector

ASHRAE 55°C 32°C 32°C

Accessories Devices

Fig.

SC12GH

Starting Relay

a2

117U6011 103N2008

Cover

b

Starting capacitor 80 µF

c

117U5019

Cord relief

d

103N1004

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

118-1917 118-1918 118-1919

CD.44.Z4.02

CK.40.B7.02

August 2002

205

SC15GH Heat Pump Compressor R134a 220-240V 50/60Hz Data Sheet (Replaces CD.44.S3.02) General SC15GH

Code number

104G8561

104G

SC15GH Application

R134a

Blue stripe Approvals

Application Application Evaporating temperature range

°C

HBP

Barcode on white background

50Hz: -10 to 20

Yellow background

8561

DANFOSS COMPRESSORS

R

60Hz: -15 to 15 °C

50Hz: 70

SC15GH 230V-60Hz 1PH

60Hz: 60 / 70 short-term Voltage range

V/Hz

198 - 254 /50 198 - 254 /60

Motor type

THERMALLY PROTECTED

CSIR

Max. ambient temperature

°C

Comp. cooling at ambient temp.

Approval mark

43

32°C

F2

38°C

F2

43°C

F2

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

Design 15.28

Oil quantity

cm3

500

Maximum refrigerant charge Free gas vol. in compressor Weight without electrical equipment

g

1300

cm3

1410

kg

13.5

watt

470

A

19.7

204 178 170

ø16

Motor Motor size LRA (rated after 4 sec. UL984) HST Cut-in current HST

A

19.7

Resistance, main and start winding (25°C)



4.3/15.3

Approvals

ø19 ø9.7

70 150

cm3

127 101.6 35

Displacement

8292-7

Condensing temperature max.

127 165 186 218

D

C E

EN 60335-2-34, UL984/CSA-C22.2

B A

B1 B2

B2

100

location/I.D. mm

C

10.2 ±0.09

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

8.2 ±0.09

August 2002

pcs.

80

CD.44.S4.02

CK.40.B7.02

255

63

183

37°

37°

107

107 115

55 63

B1

55

209 203

151

A B

Suction connector

Compressors on a pallet

206

mm

3

Dimensions Height

8292-2

Compressor

8258

1

August 2003

Capacity (EN 12900/CECOMAF) Evap. temp in °C SC15GH, 50Hz SC15GH, 60Hz

-15 425

-10 559 582

-5 723 776

watt 0 915 1012

5 1139 1295

7.2 1249 1436

10 1398 1629

15 1698 2019

Capacity (ASHRAE) Evap. temp in °C SC15GH, 50Hz SC15GH, 60Hz

-15 524

20 2041 c

watt -10 691 719

-5 895 960

0 1134 1254

5 1413 1607

7.2 1550 1782

10 1738 2025

15 2114 2515

20 2548 b 8222

Power consumption Evap. temp in °C SC15GH, 50Hz SC15GH, 60Hz

-15 355

watt -10 424 424

-5 479 494

0 526 566

5 565 639

7.2 580 671

10 596 711

15 618 782

20 632 d

Current consumption Evap. temp in °C SC15GH, 50Hz SC15GH, 60Hz

-15 2.37

a2

A -10 3.33 2.67

-5 3.46 2.97

0 3.59 3.24

5 3.73 3.50

7.2 3.79 3.61

10 3.87 3.74

15 4.01 3.97

20 4.16

c 11

10

COP (EN 12900/CECOMAF) Evap. temp in °C SC15GH, 50Hz SC15GH, 60Hz

-15 1.20

W/W

-10 1.32 1.37

-5 1.51 1.57

0 1.74 1.79

5 2.02 2.03

7.2 2.15 2.14

10 2.35 2.29

15 2.75 2.58

-10 1.63 1.70

-5 1.87 1.94

0 2.16 2.21

5 2.50 2.51

7.2 2.67 2.66

10 2.92 2.85

15 3.42 3.22

COP (ASHRAE) Evap. temp in °C SC15GH, 50Hz SC15GH, 60Hz

20 3.23

12

13 14

W/W -15 1.48

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature 50Hz: Fan cooling F2, 220V 60Hz: Fan cooling F2, 220V

EN 12900/CECOMAF 55°C 32°C 55°C

20 4.03

Start winding Main winding Winding protector

ASHRAE 55°C 32°C 32°C

Accessories Devices

Fig.

SC15GH

Starting Relay

a2

117U6011 103N2008

Cover

b

Starting capacitor 80 µF

c

117U5019

Cord relief

d

103N1004

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

2

August 2003

118-1917 118-1918 118-1919

CD.44.S4.02

CK.40.B7.02

August 2002

207

SC18GH Heat Pump Compressor R134a 220-240V 50/60Hz Data Sheet (CG.44.G1.02) General SC18GH

Code number

104G8861

104G

SC18GH Application

R134a

Blue stripe Approvals

Application Application Evaporating temperature range

°C

HBP

Barcode on white background

50Hz: -15 to 20

Yellow background

8861

DANFOSS COMPRESSORS

R

60Hz: -15 to 15 °C

50Hz: 70

SC18GH 230V-60Hz 1PH

60Hz: 60 / 70 short-term Voltage range

V/Hz

198 - 254 /50 198 - 254 /60

Motor type

THERMALLY PROTECTED

CSIR

Max. ambient temperature

°C

Comp. cooling at ambient temp.

Approval mark

43

32°C

F2

38°C

F2

43°C

F2

8292-8

Condensing temperature max.

8292-4

Compressor

S O F1 F2

= Static cooling normally sufficient = Oil cooling = Fan cooling 1.5 m/s (compressor compartment temperature equal to ambient temperature) = Fan cooling 3.0 m/s necessary

Design cm3 cm

Maximum refrigerant charge

500

g

1300

cm3

1460

kg

13.7

watt

550

LRA (rated after 4 sec. UL984) HST

A

21.8

Cut-in current HST

A

Free gas vol. in compressor Weight without electrical equipment

204 178 170

ø16

Motor Motor size

127 165 186 218

D

C

21.8

Resistance, main and start winding (25°C) Ω Approvals

ø19 ø9.7

70 150

Oil quantity

17.69

3

127 101.6 35

Displacement

E

3.5/12.1 EN 60335-2-34, UL984/CSA-C22.2

B A

B1 B2

193

B2

110

location/I.D. mm

C

10.2 ±0.09

Process connector

location/I.D. mm

D

6.2 ±0.09

Discharge connector

location/I.D. mm

E

8.2 ±0.09

August 2002

pcs.

80

CG.44.G2.02

CK.40.B7.02

255

63

B1

37°

37°

107

107 115

55 63

219 213

55

A B

Suction connector

Compressors on a pallet

208

mm

151

Height

3

Dimensions

8258

1

August 2003

Capacity (EN 12900/CECOMAF) Evap. temp in °C SC18GH, 50Hz SC18GH, 60Hz

-15 485 573

-10 639 745

-5 825 955

watt 0 1047 1207

5 1310 1506

7.2 1440 1654

10 1618 1858

15 1976 2268

Capacity (ASHRAE) Evap. temp in °C SC18GH, 50Hz SC18GH, 60Hz

-15 600 707

20 2389

a3 a2

watt -10 790 921

-5 1021 1181

0 1298 1495

5 1626 1869

7.2 1788 2054

10 2011 2310

15 2461 2825

e

20 2982

c 8227

Power consumption Evap. temp in °C SC18GH, 50Hz SC18GH, 60Hz

-15 404 449

watt -10 452 511

-5 503 577

0 554 643

5 605 708

7.2 626 736

10 651 770

15 692 826

20 724

-10 2.66 2.45

-5 2.86 2.75

0 3.06 3.05

5 3.26 3.35

7.2 3.34 3.48

10 3.45 3.65

15 3.63 3.94

20 3.80

Current consumption Evap. temp in °C SC18GH, 50Hz SC18GH, 60Hz

-15 2.44 2.14

COP (EN 12900/CECOMAF) Evap. temp in °C SC18GH, 50Hz SC18GH, 60Hz

W/W

-15 1.20 1.27

-10 1.42 1.46

-5 1.64 1.66

0 1.89 1.88

5 2.17 2.13

7.2 2.30 2.25

10 2.49 2.41

15 2.86 2.75

-15 1.48 1.57

-10 1.75 1.80

-5 2.03 2.05

0 2.34 2.33

5 2.69 2.64

7.2 2.86 2.79

10 3.09 3.00

15 3.56 3.42

COP (ASHRAE) Evap. temp in °C SC18GH, 50Hz SC18GH, 60Hz

d

A

20 3.30

b e

Start winding 5

2

4

1

a2

Main winding Winding protector 1

1

2 N L

2 N L

Bleeder resistance

c

a3

W/W

Test conditions Condensing temperature Ambient and suction gas temp. Liquid temperature 50Hz: Fan cooling F2, 220V 60Hz: Fan cooling F2, 220V

EN 12900/CECOMAF 55°C 32°C 55°C

20 4.12

M

Thermostat

Fan

ASHRAE 55°C 32°C 32°C

Accessories Devices Star ting device

Fig.

SC18GH

a3

117-7038 (470 mm cable length) 117-7039 (550 mm cable length)

Cover

b

Star ting relay

a2

Star ting capacitor

c

Run capacitor

e

Cord relief

d

103N2008 Components of star ting device 103N1004

Mounting accessories Bolt joint for one compressor Bolt joint in quantities Snap-on in quantities

118-1917 118-1918 118-1919

2

CG.44.G2.02

August 2003

CK.40.B7.02

August 2002

209

210

CK.40.B7.02

August 2003

August 2003

CK.40.B7.02

211

The Danfoss product programme for the refrigeration industry contains:

Compressors for Refrigeration and Air Conditioning A wide range of hermetic reciprocating compressors and scroll compressors as well as aircooled condensing units. The product range is applied in air conditioning units, water chillers and commercial refrigeration systems.

Compressors for Refrigerators and Freezers Hermetic compressors and fan-cooled condensing units for household refrigeration units such as refrigerators and freezers, and for commercial installations such as sales counters and bottle coolers. Compressors for heating pump systems. 12 and 24 V compressors for refrigerators and freezers in commercial vehicles, buses, and boats.

Appliance Controls For the regulation of refrigeration appliances and freezers Danfoss supply a CFC-free product range of electromechanical thermostats for refrigerators and electromechanical thermostats for refrigerators and freezers produced according to customer specification; Hermetic valves for refrigerator/freezer combinations and for energy saving applications; Service thermostats – for all refrigerating and freezing appliances.

Refrigeration and Air Conditioning Controls With our full product range we cover all the requirements for mechanical and electronically controlled refrigeration systems. The functions cover: control, safety, system protection and monitoring. Our products are applied for all commercial- and industrial refrigeration applications as well as for air conditioning.

www.danfoss.com/compressors

CK.40.B7.02

Produced by Danfoss 03.08