Proportional Pressure Reducing Valves Series PE*W (Parker), R4R (Denison)
Catalogue HY11-3500/UK
Characteristics / Technical Data
Subplate mounted proportional pressure reducing valves are available with both Parker (series PE*W) and Denison (series R4R) model codes. These valves have a proportional solenoid operated pilot stage and a cartridge main stage. The optimum performance can be achieved in combination with the digital amplifier module PCD00A-400. Features • Pilot operated with proportional solenoid • Continuous adjustment by proportional solenoid • Subplate mounting according to ISO 5781 • 4 pressure stages • Mechanical maximum pressure adjustment
4
Technical data General Nominal size Interface Mounting position Ambient temperature Weight Hydraulic Max. operating pressure Pressure stages Nominal flow Fluid Viscosity recommended permitted Fluid temperature Filtration Electrical Duty ratio Protection class Nominal voltage Max. current Coil resistance Solenoid connection Power amplifier, recommended
10 Subplate mounting acc. ISO 5781 as desired, horizontal mounting prefered [°C] -20...+80 [kg] 2.7
25
32
4.5
6.0
[bar] Ports A and X 350, ports B and Y depressurized [bar] 105, 250, 350 [l/min] 150 350 Hydraulic oil according to DIN 51524 ... 525 [cSt] / [mm²/s] 30 ... 50 [cSt] / [mm²/s] 20 ... 380 [°C] -20 ... +70 ISO 4406 (1999); 18/16/13
650
[%] 100 ED IP65 in accordance with EN 60529 (plugged and mounted) [V] 12 [A] 2.3 [Ohm] 4 at 20°C Connector as per EN 175301-803 PCD00A-400
Catalogue HY11-3500/UK. Parker Hannifin ... These valves are used to control the pressure in the sec- ondary part of .... PR32M 1). Minimum pressure curve. 1).
Nominal flow. [l/min]. 150 ... Technical data. C4V10 ... Nominal size. 5. Max. pressure. 350 bar. 3. Subplate mounting. The Denison model code is avail- able for ...
Cracking pressure. Direct operated check valve. Design series. Seals. Nominal size. Body sealing. Code. Body sealing. 1 sealing for port A. 2 1) sealing for port ...
Direct operated 2 way pressure compensators series. R5A can be combined with any type of fixed or adjusta- ble flow resistor (throttle) to provide a load ...
Racines fibreuses, cloisonnées, pâles et non ramifiées. Feuilles en rosette basilaire, minces et translucides, linéaires- lancéolées, de 1 à 6 cm de long et de 1 à ...
The fail-safe position of the directional valve during power ... With electrical connections the protective conductor (PE W) must be connected according to the ...
Catalogue HY11-3500/UK ... A manually adjusted pilot stage controls a seated type main stage. ... allows oil circulation from P to T at minimum pressure drop.
NBR. 5. FPM. 3) Position control for D5S08/10 only. Spring 2 or 4. Spool A and sleeve 3. Options ... AC: up to 7200, DC: up to 16000 switchings/hour. Solenoid ...