Characteristics The sandwich type pressure compensators series SPC are typically used in combination with proportional directional control valves.The compensator keeps the pressure drop over the directional valve constant and thus provides load-independent flow to the actuator.
Features • 2-way or 3-way pressure compensators • Standard pressure differential 5 bar • Adjustable differential (2...5 bar) and 10 bar selectable by model code • Sizes: NG06 / CETOP 3 SPC01 NG10 / CETOP 5 SPC02 NG16 / CETOP 7 upon request NG25 / CETOP 8 upon request
SPC*11 (2-way)
SPC*01 (3-way)
SPC*11 (2-way)
7
Technical data General Design Size Mounting interface Mounting position Ambient temperature Weight 2-way pressure compensator 3-way pressure compensator Hydraulic Max. operating pressure drain port L connected without drain port Nominal flow Fluid Fluid temperature Viscosity permitted Viscosity recommended Filtration
Direct operated pressure compensator 06 DIN 24340 A10 ISO 4401 NFPA D05 CETOP 03 unrestricted [°C] -20...+50 [kg] 1.5 [kg] 1.6
10 DIN 24340 A16 ISO 4401 NFPA D07 CETOP 05
3.1 3.5
[bar] [bar] [l/min]
P, A, B: 350; T: 210; L: 10 P, A, B: 315; T: 210; L: 10 P, A, B: 350; T: 160; L: 160 P, A, B: 315; T: 210; L: 210 30 80 Hydraulic oil as per DIN 51524...525 [°C] -20...+80 [cSt]/[mm2/s] 10...650 [cSt]/[mm2/s] 30 ISO 4406 (1999) 18/16/13 (acc. NAS 1638: 7)
Direct operated 2 way pressure compensators series. R5A can be combined with any type of fixed or adjusta- ble flow resistor (throttle) to provide a load ...
NBR. 5. FPM. 3) Position control for D5S08/10 only. Spring 2 or 4. Spool A and sleeve 3. Options ... AC: up to 7200, DC: up to 16000 switchings/hour. Solenoid ...
5A at 250VAC; 1A at 50VDC; 0.2A at 250VDC. The electro-hydraulic pressure switch provides an electric signal when the sensed pressure goes above or below.
Max. switching frequency. [1/h] 16000 (DC), 7200 (AC) .... The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm. Surface finish. NBR. BK375. 4x M5x30.
Seat valves series D4S are designed for directional control functions. A large variety ... 2) Springs 2, 3, 4 and 6 only. Subplate mounting ... Ext. PD from cap. â. 6.
individual hydraulic solutions for nominal flow up-to 600 ... Pilot oil line in body .... Fluid. Hydraulic oil as per DIN 51524...525. Fluid temperature. [°C] -20...+80.
shock and vibrations. The electronics are protected from ... Tube clamp. ⢠Safe mounting with a rugged SCSD-S27 clamp ... Shockproof. Instrument Features ...
Settable final pressure. Characteristics. Reliable/safe. Pressure is captured by a measuring cell with long-term stability. Any functional error is monitored and can ...
NBR. 5. FPM. Code Solenoid voltage omit. Standard w/o vent function. G0R. 12V= G0Q ... AC: up to 7200, DC: up to 16000 switchings/hour. Coil insulation class.
ated or "at rest" condition. When downstream pressure exceeds the value set by the spring force, the control piston moves off its seat, closing off the flow path ...
Series PRDM are direct operated pressure reducing valves to regulate pressure in one area of a hydraulic circuit at a predetermined level below normal system.
piston type valves with low hysteresis. They can be used as a P-T relief, and a T-T controlled counter balance valve. 4 pressure stages with max. pressure ...
The valve bodies of the Parker Manapak valve series. PRM are made of steel. ... in the valve body. ⢠Piloting results in a ... The O-rings for sealing the connecting ...
Pump ordering code. 6.3. Motor ordering ...... passing them through a 40 psi (2.8 bar) check valve before plumbing to the reser- voir. ...... Philippines. Thailand.
Adjustment. Throttle valve. Seal. FPM. Design series. (not required for ordering). V. Code ... V. SK-FM2-V-20. Note: The O-ring plate (with. O-rings) for sealing the.
When the valve poppet is open, the large cross-section allows high flow rates at low differential pressure. ⢠Different control ratios can be chosen with the NG6.