Installation and Wiring Manual Manuel pour l'Installation et le Câblage
Item #: 403260 Rev Date: 2015-05-12
EDF1
Ventilation Control System Système de contrôle de ventilation Selectable operation modes An electronic wall control timer that is compatible with all Fantech HRV/ERV models (except SH/VH 704). This control activates the system on 3 possible modes of operation: • Low Continuous Speed Operation (Green) • 20 minutes ON, 40 minutes OFF Intermittent (Yellow) • High Continuous Speed or Boost (Red)
Introduction du EDF1 Un dispositif de commande mural à trois fonctions qui est compatible avec tous les modèles de VRC de Fantech (sauf SH/VH 704). Cette commande active le système à trois modes de fonctionnement possible. • basse (LOW) vitesse continue (vert) • 20 minutes en marche et 40 minutes en arrêt (20MIN ON/40MIN OFF) cycle répétitif (jaune) • haute (HIGH) vitesse continue (rouge)
Wiring of the EDF1 Connect the wires to the EDF1 wall control. Insert the stripped end of the wires into the electrical connection. Insert the wire into the + and – of the EDF terminal connections or the "W" position of the terminal connection bloc located on the outside of the HRV/ERV system, near the power cord. Tighten screws using slot head screwdriver.
Wiring of the EDF1 Insérez les fils au contrôle mural EDF1. Insérez les bouts rayés des fils dans les connecteurs électriques. Insérez les fils dans le + et – des connecteurs du terminal ou des les position "W" des connecteurs du terminal situés sur le panneau extérieur du VRH/VRE, à proximité du cordon d'alimentation. Serrez les vis à l’aide d’un stylotournevis.
EDF1
EDF1
W or/or
Jumper settings On the back of the EDF1 there is a jumper. By default, the jumper is in the OFF position (no connection between the two steel pins). This means the Continuous ventilation mode will operate at the lowest speed. When the jumper is ON (jumper closes circuit between the two steel pins) low speed continuous mode will operate the HVR/ERV system in the normal Medium speed.
OFF
Low speed
ON
Normal Medium speed
ouvert
Basse vitesse
fermé
Vitesse normale moyenne
Réglage du "Jumper" L’arrière du contrôle mural est muni d’un cavalier. Par défaut, le cavalier est en circuit ouvert (il ne touche qu'à une seule broche), et le système de ventilation fonctionne en mode continu à la vitesse la plus basse. Lorsque le cavalier est en opération (il ferme le circuit entre les bornes) le mode continu à basse vitesse fera fonctionner le VRH/VRE à la vitesse normale MOYENNE.
OFF/ OUVERT
ON/ FERMÉ
Installation of the EDF1 Screw the control mounting plate to the box then screw the cover over the mounting plate.
Insstallation du EDF1 Visser la plaque de montage à la boite électrique puis visser le couvert à la plaque de montage.
United States 10048 Industrial Blvd. • Lenexa, KS 66061 • 1.800.747.1762 • www.fantech.net Canada 50 Kanalflakt Way • Bouctouche, NB E4S 3M5 • 1.800.565.3548 • www.fantech.net Fantech, reserves the right to modify, at any time and without notice, any or all of its products’ features, designs, components and specifications to maintain their technological leadership position. Fantech se réserve le droit de modifier partiellement ou entièrement, en tout temps et sans préavis, les caractéristiques, la conception, les composantes et les spécifications de ces produits afin de conserver sa position de leader en matière de technologie.
United States 10048 Industrial Blvd. ⢠Lenexa, KS 66215 ⢠1.800.747.1762 ⢠www.fantech.net. Canada 50 Kanalfiakt Way ⢠Bouctouche, NB E4S 3M5 ⢠1.800.565.3548 ⢠www.fantech.net. Fantech, reserves the right to modify, at any time and witho
If your original motor had the pluggable motor switch (See Figures 2B and 2C), replace .... Switch connection #6 is the centrifugal switch normally open contact. 4. Switch connections #1 and #2 are the normally open heater contacts. 5. Switch ...
12 juin 2018 - BPM Fastening. Fixation du BPM. 1. Loosely fasten both brackets “B” to cabinet using screws in the pilot holes. Don't drive the screw all the way ...
Thermostat À Bulbe Électromécanique Et. Capillaire Thermostat : Modèles Fabriqués Avant Septembre 2003. 1. Retirer soigneusement le cadran, sans modifier ...
May 19, 2010 - Advisories associated with propellers in this manual are freely disposable at ... and it´s not to be regarded as binding on any propeller type or her section. ..... The front spinner support is used to have the balance weights install
10 nov. 2012 - CONCRETE FLOOR BOX – Installation Instructions ... concrete covers are intended to keep concrete residue from entering box during pour and ...
If your refrigerator without doors does not pass through the doorway, you may .... Firmly push the handle toward the door until the handle base is flush against ...
with the stacking bracket, using (6) 1/4-20 machine screws, lock washers ... F. Plug the cord set of each unit into a 115-Volt power supply outlet. ...... Réglez la première température de cuisson à l'aide du cadran. t Ap puye z su r la to uche prod
The Federal Signal Model 1ST is a single flash strobe housed in a. Type 4? enclosure. At 0 flashes per minute and 2 5 effective candela, the Commander® is the ...
INSTALLATION AND SERVICE INSTRUCTIONS. FOR ... Use a tool against wrench flats on conduit hub for final ... E. Tighten locking screw on lens to secure. F. Test light for ..... Phone: 1-877-289-3246 ⢠1-708-534-4756 ⢠Fax: 1-708-534-4887.
knowledge can use this appliance only if they are supervised or have been given instructions on safe use and understand the hazards involved. â¡ This ...
Write the model and serial numbers here: Model # ..... disappear as freezer continues to run. Popping or cracking ... Staple your receipt here. Proof of the original ...
Your refrigerator is heavy. When moving the refrigerator for cleaning or service, be sure to cover the floor with cardboard or hardboard to avoid floor damage.
OPERATION MANUAL ..... Optimal cool down will be achieved with the door open slightly. Opening .... When baking, weigh or measure the product in each pan.
REMARQUE : Tous les systèmes d'allumage électronique sont alimentés par la vanne de gaz. Par conséquent, l'appareil n'est pas fourni avec un régulateur de ...
Inhalation of airborne particles of glass wool/ceramic fibers is known to the state of California to cause cancer. Operation of this product could expose you to carbon monoxide .... Max 13.8" WC @ 70°F (21°C). NOTE: Data applies only to. North Amer
Disconnect light from the power supply before any installation or ... For AC units, connect the phase side of the line to the black wire, the neutral side of the.
STS. 35. 60. 64. 70. 80. 20. 7 x 12. 7 x 12. 8 6. 52. 6 8. 6MA. MOUNTING CLIPS. Material: Acetal resin (delrin) and galvanized steel. DINFIX. Dinfix permits the smooth mounting of metal rails on the mounting rail. G1, thus allowing the construction o
Stovetop fan. • Central vacuum system .... the season, minimizing energy use associated with ventilation .... No Power is being transmitted to the Control Board.