Dive forward 0° to 30° Keeping course A. Cascade occurs. No. A. Classification of a paraglider's behaviour in the symmetric front collapse test accelerated. Entry.
TEST REPORT MANUFACTORY AXISPARA Procédure Poids max HARNAIS SUP AIR
AVENNE Patrick MODEL Weight in fkight TYPE
Date VEGA 110 kg abs
13-déc-06 SIZE VENTRAL
M 46 cm
Measurements and possible ranges 1 Rising behaviour Smooth, easy and constant rising A 2 Special take off technique No
A
Measurements and possible ranges in the landing test Special landing technique required No Measurements and possible ranges in the speeds in straight flight test Measurement and ranges 1 Trim speed more than 30 km/h Yes 2 Speed range using the controls larger than 10 km/h Yes 3 Minimum Less than 25 km/h Classification of a paraglider's behaviour in the control movement test Max weight in up to 80 kg Max weight in
A
A A A
80 to 100 kg
Max weight in greater than 100 kg flight croissant supérieur à 65 cm Classification of a paraglider's behaviour in the pitch stability exiting accelerated flight test 1 Dive forward angle on exit Dive forward less than 30° 2 Collapse occurs No Classification of a paraglider's behaviour in the pitch stability operating controls during accelerated flight test Collapse occurs No Classification of a paraglider's behaviour in the roll stability and damping test Oscillations Reducing Classification of a paraglider's behaviour in the stability in gentle spirals test Tendency to return to straight flight Spontaneous exit Classification of a paraglider's behaviour in the behaviour in a steeply banked turn test Sink rate after two turns up to 12 m/s Classification of a paraglider's behaviour in the symmetric front collapse test Entry Rocking back less than 45° Recovery Spontaneous in 3 s to 5 s Dive forward angle on exit Dive forward 0° to 30° Keeping course Cascade occurs No Classification of a paraglider's behaviour in the symmetric front collapse test accelerated
A
A A
A
A
A
A
A B A A
Entry Rocking back less than 45°
A
Recovery Spontaneous in less than 3 s A Dive forward angle on exit Dive forward 30° to 60° Entering a turn of less than 90° B Cascade occurs No A Classification of a paraglider's behaviour in the exiting deep stall (parachutal stall) test 1 Deep stall achieved No A 2 Recovery Spontaneous in less than 3 s A 3 Dive forward angle on exit Dive forward 0° to 30° A 4 Change of course Changing course less than 45° A 5 Cascade No A Classification of a paraglider's behaviour in the high angle of attack recovery test 1 Recovery Spontaneous in less than A 2 Cascade No A Classification of a paraglider's behaviour in the full stall test 1 Dive forward angle on exit Dive forward 30 et 60° B 2 Collapse No collapse A 3 Cascade occurs (other than collapses) No A 4 Rocking back Less than 45° A 5 Line tension Most lines tight A Classification of a paraglider's behaviour in the asymmetric collapse test to 50% Change of course until re-inflation Less then 90° Dive or roll angle 0° to 15° A Re-inflation behaviour Spontaneous re-inflation A Total change of course Less than 360° A Collapse on the opposite side occurs No A Twist occurs No A Cascade occurs No A Classification of a paraglider's behaviour in the asymmetric collapse test to 50% full speed Change of course until re-inflation Less then 90° Dive or roll angle 15° to 45° A Re-inflation behaviour Spontaneous re-inflation A Total change of course Less than 360° A Collapse on the opposite side occurs
No
A
No
A
Twist occurs Cascade occurs No A Classification of a paraglider's behaviour in the asymmetric collapse test 75% Change of course until re-inflation Less then 90° Dive or roll angle 45° to 60° B Re-inflation behaviour Spontaneous re-inflation A Total change of course Less than 360° A Collapse on the opposite side occurs No A Twist occurs No A Cascade occurs No A Classification of a paraglider's behaviour in the asymmetric collapse test 75% full speed Change of course until re-inflation 90° to 180° Dive or roll angle 15° to 45° B Re-inflation behaviour Spontaneous re-inflation A Total change of course Less than 360° A Collapse on the opposite side occurs No A Twist occurs No A Cascade occurs No A Measurements and possible ranges in the directional control with a maintained 1 Able to keep course Yes A 2 180° turn away from the collapsed side possible in 10 s Yes A 3 Amount of control range between turn and stall or spin More than 50 % of the symmetric control travel A Measurements and possible ranges in the trim speed spin tendency test Spin occurs No A Measurements and possible ranges in the low speed spin tendency test Spin occurs No Classification of a paraglider's behaviour in the recovery from a developed spin test 1 Spin rotation angle after release Stops spinning in less than 90° 2 Cascade No Classification of a paraglider's behaviour in the B-line stall test 1 Change of course before release Changing course less than 45° 2 Behaviour before release Remains stable with straight span 3 Recovery
A
A A
A A
Spontaneous in less than 3 s
A
4 Dive forward angle on exit Dive forward 0° to 30°
A
5 Cascade occurs No Classification of a paraglider's behaviour in the big ears test 1 Entry procedure
A
Dedicated controls
A
2 Behaviour during big ears Stable flight
A
3 Recovery Spontaneous in less than 3 s
A
4 Dive forward angle on exit Dive forward 0° to 30° Classification of a paraglider's behaviour in the big ears in accelerated flight test 1 Entry procedure Dedicated controls 2 Behaviour during big ears Stable flight 3 Recovery Spontaneous in less than 3 s 4 Dive forward angle on exit Dive forward 0° to 30° 5 Behaviour immediately after releasing the accelerator while maintaining big ears Stable flight Classification of a paraglider's behaviour in the behaviour exiting a steep spiral test 1 Tendency to return to straight flight Spontaneous exit 2 Turn angle to recover normal flight Less than 720°, spontaneous recovery Classification of a paraglider's behaviour in the alternative means of directional control test 1 180° turn achievable in 20 s Yes 2 Stall or spin occurs No Classification of a paraglider's behaviour when testing any other flight procedure and/or 1 Procedure works as described 2 Procedure suitable for novice pilots 3 Cascade
No. A. Dive forward less than 30°. A. Collapse occurs. No. A. Classification of a paraglider's behaviour in the pitch stability operating controls during accelerated.
1. COMET. PILOT'S MANUAL. Thank you for taking the time to read this booklet. ... If after reading this manual you have any ..... 4968 5184 5400 5616 5940. B1.
For a normal, into-wind landing evenly pull the brakes all the way down when you are about one ... Opening may be accelerated by slightly pumping the brakes.
Your sink rate will increase while your forward speed will reduce to practically zero. .... careless packing, unnecessary exposure to UV light, exposure to chemicals, heat and moisture. ... lines, canopy and risers with fresh water and dry it away fr
Rocking back less than 45° A. Recovery. Dive forward angle on exit. Dive forward 0° to 30° Keeping course A. Cascade occurs. Sink rate after two turns up to 12 ...
If you have any further questions after reading this booklet, please do not hesitate to ... When you have become familiar with your new BRIGHT III we would welcome any ..... No matter what category of canopy you fly or what level of certification it
Angaben, Beschreibungen und Abbildungen sind freibleibendund unverbindlich. VEGA/F. Rullo indipendente dalle slitte. Roller is separated from side-skids.
The TXUP5000LD belongs to the High Power UHF products family of. Television Transmitters fully in solid state technology. ... Power Control. Amplifier Control.
5.2.1. Big Ears. 5.2.2. B-line Stall. 5.2.3. Spiral Dive. 5.3. SIV manoeuvres ... The Avax XC3 is a high-performance wing, a top 'Serial Class' competition glider, ... This manual provides information which will help you fly safely and keep your wing
GRADIENT dealer and we will gladly answer all your questions. We would ..... No matter what category of canopy you fly or what level of certification it has, in turbulence or .... GRADIENT wishes you many fabulous flights and happy landings.
CERTIFICATION. The Avax XC2 have in all sizes a new European certification EN. ..... unnecessary strain on the attachment tabs during inflation. Snagging lines ...
Classification of a paraglider's behaviour in the recovery from a developed spin test. Spin rotation angle after release. 2. 3. 4. 5 Cascade occurs. Recovery.
Amplificacion clase AB ... Disponibilidad de telecontrol al amplificador final ... Frequency. 50-60Hz, ± 5%. Temperature operating range. 0 to 45°C. Altitude.
Power Control ... Thanks to the amplitude and phase pre-correction circuit, it is ... The amplifiers employ solid state LDMOS technology in order to obtain wide ...