2 Way Seated Type Directional Control Valve Series D1SE
2. Characteristics. The directional valve type D1SE is equipped with a wet pin armature solenoid, drain free tapered poppet valve and compatible with the ...
3/2 Way Seated Type Directional Control Valve Series D1SE
Catalogue HY11-3500/UK
Characteristics The directional valve type D1SE is equipped with a wet pin armature solenoid, drain free tapered poppet valve and compatible with the standards DIN NG06, CETOP 03, and NFPA D03. Due to the 3/2 way design, port A is either connected with P or discharged in the tank. The neutral position (solenoid not activated) is taken automatically by a return spring. This position remains until the solenoid is energized. The valve poppet including activation lever and armature of the solenoid are located in the pressurized oil chamber of connection T. The valve poppet is designed such that there can be no differential area in its axial operational direction (opening, closing). Thus it is statically pressurebalanced so that the valve can be switched in both flow directions even under pressure. The unit has an all-steel design, the important functional inner parts are hardened, the poppet and seat are grinded.
2
Technical data General Design Actuation Size Mounting interface Mounting position Ambient temperature [°C] Weight [kg] Hydraulic Max. operating pressure P, A and T [bar] Fluid Fluid temperature [°C] Viscosity permitted [cSt] / [mm²/s] Viscosity recommended [cSt] / [mm²/s] Filtration Flow max. [l/min] Static / Dynamic Step response [ms] [ms] Electrical characteristics Duty ratio Max. switching frequency [1/h] Protection class Code Supply voltage [V] Tolerance supply voltage [%] Current consumption [A] Power consumption [W] Solenoid connection Wiring min. [mm²] Wiring length max. [m]
Directional poppet valve Solenoid DIN NG6 / CETOP 03 / NFPA D03 DIN 24340 A6 / ISO 4401 / CETOP RP 121-H / NFPA D03 Unrestricted -25...+50, observe permissible duty cycle 1.5 350 Hydraulic oil in accordance with DIN 51524 / 51525 -25 ... +70 10...500 30...80 ISO 4406 (1999); 18/16/13 (meet NAS 1638: 7) 20 Energized: approx. 50 De-energized: approx. 60 See diagram 2000 IP65 in accordance with EN 60529 (plugged and mounted) K J U 12 V = 24 V = 98 V = ±10 ±10 ±10 1.95 1.1 0.25 23.4 26.4 24.3 Connector as per EN 175301-803 3 x 1.5 recommended 50 recommended
G 205 V = ±10 0.13 26.6
With electrical connections the protective conductor (PE W) must be connected according to the relevant regulations.
3/2 Way Seated Type Directional Control Valve Series D1SE
Performance curve ∆p-Q
Duty cycle versus ambient temperature
Catalogue HY11-3500/UK
2
Dimensions
Surface finish
NBR BK375
4x M5x30 DIN 912 12.9
7.6 Nm ±15%
NBR: SK-D1SE-70 FPM: DK-D1SE-V70
Subplates and manifolds see chapter 12.
The space necessary to remove the plug per EN 175301-803, design type AF is at least 15 mm. The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm. D1SE_UK.INDD CM
Max. switching frequency. [1/h] 16000 (DC), 7200 (AC) .... The torque for the screw M3 of the plug has to be 0.5 to 0.6 Nm. Surface finish. NBR. BK375. 4x M5x30.
INDD CM. Catalogue HY11-3500/UK ... 2 way flow control valves series 2F1C provide pressure and viscosity ... Minimum pressure difference curves. 2F1C02.
Hydraulic Controls Division. Kaarst, Germany. 2 Way Flow Control Valve. Series GFG2. 5. Characteristics. 2 way flow control valves are used to provide pressure.
NBR. 5. FPM. 3) Position control for D5S08/10 only. Spring 2 or 4. Spool A and sleeve 3. Options ... AC: up to 7200, DC: up to 16000 switchings/hour. Solenoid ...
Seat valves series D4S are designed for directional control functions. A large variety ... 2) Springs 2, 3, 4 and 6 only. Subplate mounting ... Ext. PD from cap. â. 6.
individual hydraulic solutions for nominal flow up-to 600 ... Pilot oil line in body .... Fluid. Hydraulic oil as per DIN 51524...525. Fluid temperature. [°C] -20...+80.
Catalogue HY11-3500/UK. Parker Hannifin GmbH ... 3/2 Way Seated Type Directional Control Valve ...... The minimum pilot pressure must be ensured for all op-.
Catalogue HY11-3500/UK. Parker Hannifin GmbH ... The minimum pilot pressure must be ensured for all op- erating conditions of the ... 1. Directional control valve. Style. Pilot. NG 06. Spool type. Series. 3 position spools. Code. Spool type a. 0.
NFPA D03. NFPA D05. NFPA D07. NFPA D08 .... 14. 15. 2 position spools. Code. Spool type a b. 20. 30. 1) Only available for D4L. 2) Consider specific spool.
Nov 19, 2002 - If only the Throttle Position (TP) actuator -V60- is without power, the throttle valve also assumes a mechanical closed throttle position (limp- ...
See Fig. 1 for typical piping and Fig. 2 for space. 1-1/2 (38). 1. MIN. ... Fig. 1. Typical piping. H. MINIMUM FOR. REMOVAL OF VALVE. VALVE. SIZE ... COMMON.
bar. PSI. 250. 3600. Max intermittent peak pres- sure Work port A/B bar. PSI. 320 ..... 211 â 320. (3000 â 4600). 11.11.1 Port relief valve. Type. OA. Flow rate bar.
Mar 2, 2018 - Software and its engineering~Functional languages ..... chrome: https://www.cnet.com/news/google ... berlin.de/lehre/WS03/alpi/lambda.pdf.