Sensors
Transmitters
Transmitters
Sensors
Pressure • Temperature • Humidity • Velocity and Airflow
p.
04
Monostats Temperature Humidity Pressure
Class 50
p.
05
Temperature Humidity Pressure
p.
06
Class 100 Temperature Temperature - Humidity Pressure
Class 200
Transmitters
p.
Case
ABS - Aluminium
Display
LCD - Alphanumeric - Graphic
Configuration
Switch - Keyboard - Software - Remote control
Exits
Analogical - Digital
08
Temperature - Humidity Pressure - Speed - Flow Speed
Outline of the range Designed and manufactured in France, the KIMO range of transmitters is perfectly suited to any industry, process, building services, indoor climate, OEM... Many models : from the simplest to the most complete, they can be used in any application, due to their easy configuration and calculation functions. Innovating range : the interchangeable measuring elements enables easy maintenance and on-site calibration.
p.
10
Class 300 Temperature - Humidity Pressure Speed - Flow
Technology : Analog and digital measure and output (Modbus communication system) of the KIMO range, can be adapted
Billposters
on any existing or new installations.
p.
14
Temperature - Humidity Pressure Speed - Flow
Relay reverser Protocol MODBUS Exchangeable elements of measure Functions of calculation
p.
15
Akivision
Power plant Of acquisition
02
p.
16
Probes
Of temperature
p.
17
Useful info
Sensors and Supplies
p.
18
Innovations
Of the range
03
Monostats
Applications Air conditioning
Cold
Applications
Class 50
Refrigeration
OEM/Manufacturer
Case ABS
1 relay reverser 3A / 230Vca
Case ABS
Analogical exits and
Display LCD
Supply 24Vca / Vcc
Simple and fast installation
Supply 24 Vca / Vcc Except TM50)
Configuration by switch or software
Configuration by switch or software
IP65
Thermostats
Indoor climate
TST
Temperature Ranges
Range
from 0 to +50°C (TST-M) from -50 to +400°C (TST-B) from -20 to +80°C (TST-E) Selection of the units °C or °F
TST-E seal
Output Selection of units
TM50 from +10 to +40°C (TM50-A) from -50 to +400°C (TM50-B / TM50-E) Pt100 on terminal block °C or °F
IP65
IP30
IP30
IP65
TM50-A Ambient TST-M Ambient
TM50-B Entered Pt100 on bornier Optional probe
IP65
TM50-E Seal
TST-B Optional deported probe
IP30
Hygrostats Selection of the units Range
IP65
Humidity
HST %HR, °C or °F from 0 to 100 %HR and from -20 to +80 °C (HST-A / HST-D) or from 0 to +50 °C (HST-M)
IP30
Range Sensor Selection of units Output
HM50 from 0 to 100 %HR ambient %HR 4-20 mA or 0-10 V
IP65
HST-D Deported probe
HST-M Sensor of atmosphere Openwork case
HST-A Back probe
IP65
Manostats Selection of the units
04
IP65
PST Pa, mmH2O, mbar, InWg, KPa et PSI
Pressure References
Ranges
PST-1
0-1000 Pa
PST-2
0-10 000 mmH2O
PST-3
0-500 mbar
PST-4
0-2000 mbar
Range Selection of units Outputs
CP50 from 0 to 10 000 Pa (configurable range) Pa, mmH2O, mbar, InWg, mmHg 4-20 mA and 0-10 V
05
Applications
Class 100
Refrigeration
Air-conditioning Industries
With or without billposter LCD
OEM
OUTPUTS
Temperature
Precision of the measure Case ABS Simple and fast installation
configurable
Ranges
Configuration by switch or software
Selection of units Output
Pressure
TG100
CP100
from -20 to +80°C (Back probe) -50 to +400°C (Sonde auf bornier) °C or °F 4-20 mA ou 0-10 V
IP65
IP65 TG100 Sound PT100 on bornier (Optional probe)
References
IP65
TG100 Back probe
Ranges
CP101
0-1000 Pa
CP102
0-10 000 Pa
CP103
0-500 mbar
CP104
0-2000 mbar
Ranges Connection Selection of units Output
TM100 Ranges
configurables barbed or compression fittings Pa, mmH2O, mbar, InWg, mmHg, KPa et PSI 4-20 mA or 0-10 V
Selection of units Output
from -20 to +80°C (tight probe) et de 0 à +50°C (ambient probe) °C or °F 4-20 mA ou 0-10 V
IP30
TM100 Ambient probe (Openwork case)
Air velocity Ranges Polycarbonate probe Selection of units Output
TM100 Tight probe
IP65
CTV100 from 0 to 30 m/s and from 0 to +100°C duct mount or remote m/s, fpm, °C et °F 4-20 mA or 0-10 V
IP65
Temperature Humidity Ranges Selection of units Output
CTV100 Remote probe
TH100
from 0 to 100 %HR and from -20 to +80°C %HR, °C or °F 4-20 mA or 0-10 V
IP65 IP65
IP65 CTV100 Duct mount
TH100 Back probe
IP65
TH100 Standard probe
TH100 Deported probe
06
07
Class 200
Applications Industries
Laboratories
Liaison
Visual alarm
With or without billposter
Graphic billposter
Offices of calculation
Configuration by keyboard or software
2 relays reversers
RS 232 SORTIES
Digital exit(release) RS 232 for external sensor Case ABS seals IP65 Simple and fast fixation
Analogical exits Configurable
Standard range
100
0
20
(%HR • °C • Pa...)
New range
TH200
form 0 to 100 %HR and -40 to +180°C Standard or deported (cf. Picture of probes) %HR, g/Kg, KJ/Kg, °C and °F 2 x 4-20 mA ou 2 x 0-10 V
Ranges Probe Slection of units Output
IP65
configurables
Functions :
Standard range or configure your own : the outputs are automatically adjusted to the new range.
0
Temperature / Humidity
80
• Temperature • Relative humidity • Enthalpy
• Relative humidity • Absolute humidity • Dew point calculation
100
Stainless steel or PC probes 0V 4mA
10V 20mA
CP200
• Stainless steel perforated head • PTFE sintered tip
L’EHK 500 is a portable device standard for the fitting in hygrometry and connection RS232. + d’infos p.18
0-1000 Pa
CP202
0-10 000 Pa
CP203
0-500 mbar
CP204
0-2000 mbar
Connection Selection of units Outputs
barbed or compression fittings Pa, mmH2O, mbar, InWg, mmHg, KPa and PSI 2 x 4-20 mA or 2 x 0-10 V
IP65
• • • •
Manuel auto-zero Measuring integration Measuring correction factor Temperature compensation
Change of the element of simple and fast measure. Recognition automatic.
TH200/CTV210/CP200
• Remove • Clip • Measure!
}
Made of Stainless steel Polycarbonate
Functions : Pressure Air velocity Airflow with Pitot, Debimo...
Interchangeable probes Smart-PRO System
+ d’infos p.19
+
Ranges
CP201
• • •
10V 20mA
On-site calibration
Pressure References
0V 4mA
• Embout Inox fritté • Protective plastic head
Ranges -40 to +180°C (SS) -20 to +120°C (PC)
Probes Standard Remote
Lengths 100 mm 150 mm 300 mm
IP65
Accessories for airflow • DEBIMO measuring • Tubes of Pitot with probe of integrated temperature
Air velocity/Airflow SQR/2 function
CTV210
(optional)
Calculation of the speed of air and the flow in girdle according to the differential pressure.
Ranges Probe Selection of units Outputs
from 0 to 30 m/s and from 0 to +50°C stainless steel hotwire (lg. 150mm or 300mm and of cable de 2m) m/s, fpm, °C, °F, m3/h, m3/s, L/s, cfm 2 x 4-20 mA or 2 x 0-10 V
+ d’info p.19
Functions : • Correction factor • Air velocity / airflow • Measuring
08
09
Class 300
Applications Industries
Laboratories IP65
Connection
Visual alarm
MODBUS
Configurable
Temperature / Humidity
RS 232
Digital display Software or keypad configuration
Protocole
Digital entry For external sensor
2 relays contacts / RCR
Case Alu or ABS seals IP65 Simple and fast fixation
Digital communication
Smart-Pro
With or without billposter Functions of calculation
Ranges Probe Selection of units Outputs Wavelength
0 to 100 %HR and -20 to +120°C 0 to 100 %HR and -40 to +180°C standard or remote %HR, g/Kg, KJ/Kg, °C and °F 2 x 4-20 mA or 2 x 0-10 V 100mm / 150mm / 300mm
(Polycarbonate) (Inox)
Functions :
Interchangeable probes
• Temperature • Wet buld temperature • Enthalpie
Demonstrate - Clip - Measure!
System
EXITS
TH300
Change of the element of simple and fast measure. Recognition automatic.
• Relative humidity • Absolute humidity • Dew point calculation
+ d’infos p.19
Modbus network
Configurable analog outputs
Class 300 transmitters can be linked in one network, on a RS 485 home bus. They can also be integrated into an existing network.
Standard range or configure your own : the outputs are automatically adjusted to the new range.
0
Standard range
IP63
THA300
100
(%HR • °C • Pa...)
Ranges RS232
0V 4mA
10V 20mA
Probe Selection of units Output Wavelength
RS485
0
0-10 V RS485
20
New range
80
100
0 to 100 %HR and -20 to +120°C 0 to 100 %HR and -40 to +180°C standard or remote %HR, g/Kg, KJ/Kg, °C and °F 2 x 4-20 mA or 2 x 0-10 V 100mm / 150mm / 300mm
(Polycarbonate) (Inox)
4-20 mA
0V 4mA
10V 20mA
Functions : • Relative humidity • Absolute humidity • Dew point calculation
• Wet buld temperature • Temperature • Enthalpie
IP65
Air velocity/Airflow Ranges Probe Selection on units Outputs
CTV310
Functions : • Coefficient of correction of the measure • Air veliocity • Airflow
10
On-site calibration
from 0 to 30 m/s and 0 à +50°C fil chaud inox (lg. 150mm or 300mm and câble de 2m) m/s, fpm, °C, °F, m3/h, m3/s, L/s, cfm 2 x 4-20 mA ou 2 x 0-10 V
TH300/THA300
THE EHK 500 is a portable device standard for the fitting in hygrometry via a simple connection RS232. + d’infos p.18
Stainless steel or PC probes • Sintered Stainless tip • Protective plastic head
TH300/THA300
+
• Stainless steel perforated head • PTFE sintered tip
11
IP63
Pressure
CP300
Connection Selection of units Outputs
References
CPA300
barded Pa, mmH2O, mbar, InWg 2 x 4-20 mA or 2 x 0-10 V and RS 232
Ranges
CP301
0-100 Pa
CP302
0-500 Pa
CP303
0-1000 Pa
CP304
0-10 000 Pa
IP65
Connection Selection of units Outputs
barded Pa, mmH2O, mbar, InWg 2 x 4-20 mA or 2 x 0-10 V and RS 232
Functions : • • • •
Pressure and air velocity Airflow with Pitot, Debimo Airflow with other coefficients Integration of measure
• • •
Self-calibration Measuring correction factor Temperature compensation : manual or automatic (thermocouple Kinput)
Functions :
References
• • • • • • •
CPA301
Pressure Air velocity Airflow with Pitot, Debimo... Manual or automatic Integration of the measure Coefficient of correction of the measure Compensation of the temperature
Ranges 0-100 Pa
CPA302
0-500 Pa
CPA303
0-1000 Pa
CPA304
0-10 000 Pa
CPE300 References Installation Connection Selection of units Outputs
fluls-mount ou wall-mount barbed Pa, mmH2O, mbar, InWg 4-20 mA or 0-10 V and RS 232
Functions : • • • •
Air velocity Airflow Coefficient of correction of the measure Regulation by infrared remote control
IP65
CPE300 Brushed stainless steel
CPE301
0-100 Pa
CPE302
0-500 Pa
CPE303
0-1000 Pa
CPA ZC Ranges Outputs Relais Display
Alternated display
-100 to +100 Pa and -1000 to +1000 mmH2O 4-20 mA or 0-10 V 2 in 4 relays reversers 6A / 230 Vac to LED with a graduation of color and digital billposter of the measure
IP63
Alternated
Thanks to its connection RS 232, the CPE300 can read and post in alternation, besides the pressure, measures of temperature and humidity of a TH200 for example.
Calibration opposite before
Ranges
+
%HR
Pa
°C D I S P L AY
Functions : • • • • •
Pressure Air velocity Airflow with Pitot, Debimo... Manual or automatic Intégration de la mesure
• •
Coefficient of correction of the measure Compensation of the temperature
Without dismantling of the sensor nor the modification of the initial connecting. + of info p.18
Accessories for airflow
Function SQR (optional)
• DEBIMO measuring blades
Calculation of the speed of air velocity and the airflow according to the pressure
• Tubes of Pitot with probe of integrated temperature
+ of info p.19
CPE300 Inox laqué blanc
12
13
Display
Applications Refrigeration
Air-conditioning
Connection
Easy and fast installation Digital communication
RS485
...
Centrale d’acquisition
MODBUS
Applications
RS 232
Configuration by infared remote control 0-10 V
Industries
Building services, indoor climate
Parfaitement appropriée à la surveillance de process et au contrôle des paramètres suivants : température, humidité, pression, vitesse d’air, débit d’air, la centrale d’acquisition AKIVISION convient à toutes les applications de l’agroalimentaire, du tertiaire et de l’industrie.
System
4-20 mA
Akivision Permet de configurer, d'enregistrer, de visualiser en temps réel, et d'exploiter toutes les mesures provenant de votre installation de capteurs et sondes KIMO.
Logiciels compatibles avec la gamme précédente
RS232
Our range of sensors offers you the possibility of establishing you sensors’ network working on a bus of ground RS485 (Modbus) or to integrate our sensors into your existing network.
• Pressure • Airflow • Air velocity
Akivision CFR
RS232
Large display
IP65
SALLE 1
de -9 999 à 99 999 5 matrices (H. 53 mm) 4 digits / 14 segments (H. 12,7 mm) digital for external transmitter 3 x 4-20 mA ou 3 x 0-10 V and numerique input for external transmitter
Compatibility of entries current / tension Accept all the entries of current or tension resulting from any sensor-transmitter : pressure, humidity, temperature, airflow, air velocity ...
Multi-channel
flush-mount display
ATE300
Present the advantage to post 3 parameters in alternation (ex. humidity, temperature and pressure).
RS485 0-10 V
Akivision A La version A du logiciel AKIVISION vous permettra de configurer l'ensemble des capteurs et modules de votre installation, d'enregistrer et de visualiser en temps réel les mesures.
Configuration de l’acquisition Visualisation de l’acquisition
Akivision E Grâce à la version E du logiciel AKIVISION vous pourrez très simplement exploiter, consulter, analyser et imprimer toutes les valeurs mesurées.
Alternated %HR
Pa
Exploitation des données et exportation
°C D I S P L AY
14
4-20 mA
Gestion des utilisateurs
de -999 à 9 999 4 digits / 7 segments (H. 14,22 mm) 4 digits / 14 segments (H. 12,7 mm) digital for external transmitter 3 x 4-20 mA ou 3 x 0-10 V and numerique input for external transmitter
Alternated display
SALLE 2
USB
Configuration des appareils et des modules
Editing integrated into partition or into projection. Display Display of the measure Display of units Input Analog inputs
RS485
RS485
ATT300
Display Display of the measure Display of units Input Analog inputs
Le logiciel AKIVISION CFR est l’outil indispensable pour les utilisateurs dont la traçabilité est soumise aux normes strictes de la 21 CFR part 11. La sécurité et l’intégrité de vos données sont protégées contre toute manipulation ou falsification.
• Temperature • Hygrometry • ...
NOUVEAU
Preprogrammed units of measure:
MODBUS system
IP65
Journal des alarmes Consultation & visualisation à distance de vos enregistrements
15
Sondes de température
Informations utiles
Sondes standards ou sur mesure Votre besoin : votre sonde
Sondes Thermocouple K, J, T, N
Parce que votre application est spécifique, nous réalisons votre sonde sur mesure.
Sondes Pt100 / Pt1000 Sondes CTN
CONTACTEZ-NOUS !
Capteurs d’hygrométrie Principe : la constante diélectrique du capteur d’hygrométrie varie en fonction du taux d’humidité ambiant. L’information, traduite sous forme de fréquence,
Signal transmis vers le capteur sous forme de fréquence
est transmise vers le capteur qui va, à son tour, la transformer en valeur
Sondes à tête
numérique. Le signal de mesure est indépendant de la pression ambiante.
Sonde d’hygrométrie numérique
Tête alliage Alu / Noryl® / Inox Plongeur inox, acier réfractaire, Inconel®, revêtement Alard... Montage simple ou duplex
Principe : la constante diélectrique du capteur d’hygrométrie
Couche polymère
Système Signal transmis vers le capteur sous forme de valeur numérique
traduite sous forme de fréquence, est transformée par transmise au capteur.
Références
élément de mesure capacitif
varie en fonction du taux d’humidité ambiant. L’information, le micro-contrôleur de la sonde en valeur numérique puis
Capteur
Pour contact tuyauterie
Capteurs de température
Avec élément interchangeable
TPTT-50
Micro-contrôleur
Fréquence
Smart-Pro
élément de mesure capacitif
Spécificités
TBCT TBEIK
Substrat en verre
Capteur
Sonde d’hygrométrie capacitive
Capteurs de pression
Pour application aggressive
TBARK
Avec acier réfractaire
...
Pression
Pt100
Principe
Principe : une Pt100 est une résistance
Un capteur de pression (de type
à coefficient de température positif
piézorésistif) génère une tension
variant en fonction de la température.
proportionelle à la pression
Plus la température est élevée, plus la
appliquée au capteur.
+ + + + + +
Générateur de tension
V
valeur de la résistance augmente : Pour 0°C ≈ 100 Ω
Sondes filaires
Pour 100°C ≈ 138,5 Ω
Câble PVC / Silicone / Teflon® / Soie de verre Flexible inox Sortie 2, 3, 4 fils (montage simple ou duplex)
Calcul du débit
Thermocouple K Principe : la mise en contact de deux métaux de
Principe
matière différente génère une tension aux bornes
Le débit permet de quantifier un volume s’écoulant d’une
des deux fils. Cette tension est proportionnelle à la température mesurée.
Références SF-50 SFR-50 SFKI ...
Spécificités
Obtenir une mesure de débit à partir d’une vitesse : Fil métallique
Sortie sur connecteur DIN
Soudure Fil métallique
à raccord
bouche ou d’une gaine à une vitesse prédéfinie.
Débit = Vitesse x Section Obtenir une mesure de vitesse à partir d’une pression :
Vitesse = Coef x
Avec plongeur
Pression
Alimentations Capteur à boucle passive Principe : le capteur est alimenté par une tension continue : on mesure alors le courant
élément sensible
consommé par le capteur. Ce courant varie entre 4 et 20 mA proportionnellement au
Convertisseurs Brides de fixation Doigts de gant Raccords coulissants étanches
16
paramètre de mesure (pression, température ou hygrométrie).
Capteur actif Principe : le capteur génère un courant (4-20 mA) ou une tension (0-10 V). Il peut