ss-2007 install AWS

*SS-2007/LTLUL NOTES: For access control installations, power for the LT-1UL Timer must be supplied by a power source listed to UL294. When used for access control, this device shall be used as part of an access controlled egress door system. It is up to the local AHJ to allow use of this device in place of an automatic ...
132KB taille 8 téléchargements 337 vues
O

Safety Technology International, Inc.

Safety Technology International (Europe) Ltd.

2306 Airport Road • Waterford, Michigan 48327-1209 Phone: 248-673-9898 • Fax: 248-673-1246 Toll Free: 800-888-4784 • E-mail: [email protected] Web: www.sti-usa.com

Unit 49G Pipers Road • Park Farm Industrial Estate • Redditch Worcestershire • B98 0HU • England • Tel: 44 (0) 1527 520 999 Fax: 44 (0) 1527 501 999 • Freephone: 0800 085 1678 (UK only) E-mail: [email protected] • Web: www.sti-europe.com

+ BACKPLATE ASSEMBLY

#1

#2

#3

_

+

_

L

L

TO DEVICES

L

SINGLE DEVICE LIGHT MAINTAINED FOR LAMP VOLTAGE SEE CHART BELOW

L INSERT BUTTON ASSEMBLY INDEXING TABS INTO LAMP HOLDER SLOTS THEN TWIST CLOCKWISE AS SHOWN TO LOCK.

TO DEVICES

+ +

MULTIPLE DEVICES N/C LIGHT MAINTAINED SERIES WIRING

SWITCH ASSEMBLY SEE VIEW BELOW

BURNDY FORK TERMINAL #TP14-6F OR EQUIVALENT

NO NC

L L #2 O

L L #3 O

10271 STATION HOUSING RED, GREEN, WHITE, YELLOW AND BLUE 10272-S BACKPLATE ASSEMBLY (SMOKE COLOR ONLY)

SH PU

10A, 1/2 HP, 125/250 VAC 6A, 30 VDC MODELS WITH LT-1 TIMER: FORM C CONTACTS RATED 120 VAC, 3A 28 VDC, 3A

MULTIPLE DEVICES N/O LIGHT MAINTAINED PARALLEL WIRING

LAMP (SEE CHART) STANDARD #656 STATION LABEL

19001 SCREW #8-32 X 3/8 in. (1) PROVIDED

REMARQUES POUR *SS-2**7/LT1-UL: Pour les installations de contrôle d’accès, l’alimentation de la minuterie LT-1UL doit être fournie par une source homologuée UL294. Lorsque cet appareil est utilisé aux fins de contrôle d’accès, il doit faire partie d’un système de porte de sortie à accès contrôlé. Il incombe donc à l’AHJ local d’autoriser l’utilisation de cet appareil au lieu d’un capteur automatique. Pour les installations de sécurité plus renforcée, des délais inférieurs doivent être utilisés. Pour les modèles SS-2**7/LT1-UL, la minuterie intégrée doit être installée et utilisée suivant la fiche d’installation LT-1UL fournie. La cote maximale des modèles * SS-2**7/LT1-UL est de 30 VCC 3A.

TERMINAL BLOCK LEGEND SWITCH RATINGS CHART

NO

10277 SHELL WHITE

(-)

*SS-2007/LTLUL NOTES: For access control installations, power for the LT-1UL Timer must be supplied by a power source listed to UL294. When used for access S control, this device shall be used as part of an access controlled egress door system. It is up to the local AHJ to allow use of this device in place of an automatic sensor. For higher security installations, lower time limits should be used. For SS-2007/LTUL the enclosed timer is to be used and installed per the enclosed LT-1UL installation sheet. SS-2007/LTUL maximum rating 30 VDC 3A.

C - COMMON

C

(+)

BURNDY SPADE TERMINAL #NC14F2590 OR EQUIVALENT

NO

C

BUTTON ASSEMBLY 10111 (GREEN) 10110 (RED) LAMP HOLDER (PART OF SWITCH ASSEMBLY)

14-16 AWG

NO

C

19010 SCREWS #6-32 x 1 in. BACKPLATE TO ELECTRICAL BOX (2) PROVIDED

10112 SWITCH ASSEMBLY WITH SCREW TERMINALS SEE SWITCH RATINGS CHART

C

O

19021 GROUND LUG #10-32 x 3/8 in. (1) PROVIDED

RETAINING NUT

(+)

NC - NORMALLY CLOSED

_

L #1

VIEW SHOWING INSTALLATION OF LAMP HOLDER TO BUTTON ASSEMBLY

NO - NORMALLY OPEN

N/O

C

19015 ALLEN WRENCH 3/32 (1) PROVIDED

LAMP CHART TYPE

BASE

VOLTS

WATTS

AMPS

RADION PT. NO. OR EQUIVALENT

AVERAGE LIFE (Hrs.)

FILAMENT

T3-1/4 WEDGE

6.3

1.57

0.25

50N8079 / #555

3000

FILAMENT

T3-1/4 WEDGE

14

1.12

0.08

#658

15,000

FILAMENT

T3-1/4 WEDGE

28

1.68

0.06

50N8109 / #656

2500

Electronic warranty form at www.sti-usa.com/wc14

INSTALLATION OF SS-2007 SERIES STOPPER® STATION All specifications and information shown were current as of publication, and are subject to change without notice. 10278IS APRIL2011

TO DEVICES