Ground cable Positive line Cover for positive terminal Bracket Nut
G1
Battery
P54.10-2052-06
Vehicles with code P98 Black Series 1 2 4 5 6
Ground cable Positive line Bracket Nut Venting hose
G1
Battery
P54.10-2815-01
Remove/install Danger!
Risk of explosion caused by escaping oxyhydrogen gas. Risk of injury caused by caustic burns to eyes, skin and mucous membranes from battery electrolyte (contains diluted sulfuric acid) or metal spatter due to short circuit. Risk of burn injuries caused by short circuit. Risk of poisoning caused by swallowing battery electrolyte (contains diluted sulfuric acid) or absorption of lead over the skin or orifices Notes on battery
No fire, sparks, open flames or smoking. Wear acid-resistant gloves and clothing and safety glasses with side guards. Do not place any conductive objects on the battery and avoid any short circuit from battery positive to ground. Only fill liquid battery electrolyte (diluted sulfuric acid) into suitable and appropriately marked containers.
AH54.10-P-0001-01A
Notes on AGM battery 1
Detach ground line (1) from battery (G1)
2 3
Remove positive terminal cover (3) Detach positive line (2) from battery (G1)
4 5 6 7
Detach vent hose (6) from battery (G1) Unscrew nuts (5). Take out bracket (4) Lift out battery (G1)
8
Install in the reverse order
AH54.10-P-0002-01A Model 203 Model 209 Vehicles without code P98 Black Series
AR54.10-P-0003P AR54.10-P-0003Q
Installation: Ensure that the positive line (2) is firmly seated, otherwise the positive terminal may be damaged. Vehicles with code P98 Black Series
If battery is defective (G1): Dispose of battery.