Modular Indirect Recessed 4-Lamp, TT, T5, T5HO, T8, Indirect Distribution Project Information Project Name
Type
Catalog No.
Date
Construction Recessed 9" deep housing is formed of code gauge steel and welded in a one-piece assembly for installation in a 4' × 4' ceiling system. Exposed chamfered “skirt” assembly shields electrical system with concealed lamp source. “Skirt” assembly is of one-piece welded steel construction and held in place by positive drawn heavy duty torsion springs on type “F” version.
Features • Recessed indirect coffer light provides the appearance of a handcrafted cove at a fraction of the cost • Customized appearance available with optional trim colors • Aesthetic variety provided by wood or painted steel trim • Available for type G lay-in ceilings, type F plaster ceilings, or sheet rocked ceilings
Finish Finish of interior coffer is a textured baked enamel surface. Color is a neutral cream that efficiently reflects fluorescent source output and provides a warm ambient illumination for most room color schemes. Standard finish of exposed “skirt” is baked, powder coat, matte white enamel. A variety of applied trim options to integrate with interior furnishings and designs are available upon request. For custom colors and trims, consult your Alera representative.
Ceiling Compatibility Fixture is designed to fit NEMA type G (lay-in) and type F (overlapping flange) ceiling systems. Luminaires for type F ceilings are provided with necessary adjustable wing hangers for leveling and support of unit. Labels and Electrical All fixtures bear UL recessed fixture label. Fixtures are designed for use with four lamps. Dimming systems are subject to ballast compatibility and must be quoted. CSA approval available. Use suffix “CSA”. Name: Test #: Efficiency: LER:
MIR44-439-EP 13446 49.8% 34
Installation Modular Indirect Recessed units are designed for quick installation in 4' × 4' ceiling systems. Final wiring and inspection will ordinarily require access from an adjacent ceiling module or through internal electrical wireway.
Ordering Information
MIR Model MIR Modular Indirect Recessed
Example: MIR44-4T5-G-EU-MW-CZIG-GLR
— 4 Size 22 2' × 2' (36W TT only) 33 3' × 3' 44 4' × 4' 55 5' × 5'
no. of Lamps 4 Four
— Ceiling Compatibility G Grid Trim (For 1" inverted T-Bar) F Overlap Flange Trim1 (For hard ceilings) G cannot be converted to F and F cannot be converted to G.
Lamp Type TT Twin Tube Compact Fluorescent (2' × 2' only) T5 T5 T5HO T5HO T8 T8
1
— U 120 277 347
Voltage 120V-277V 120V 277V 347V
Ballast E Electronic, Instant Start, (Std. for T8) EP Electronic, Programmed Start (Std. for T5 & T5HO, optional for T8) ED Electronic, Dimming (Must specify) ETT Electronic Twin Tube Unless specified, Alera will use fewest ballasts possible.
MW Skirt Color MW Matte White (Std.) See MTX-1 for other color selections.
—
—
Custom Trim (Optional) Blank Solid Trim (Std.) CZIG Classical Ziggurat PERF Perforated Skirt WOOD Hardwood (Specify oak, walnut or cherry)
Options EFH Extended Flange Hanger (Minimum 2½", maximum 4" depth adjustment) GLR Fast Blow Fuse GMF Slow Blow Fuse CSA UL listed or CSA certified for Canada DL Damp Label (Available on most models)
Not available in 2' x 2'
Page 1/2 Rev. 07/25/12 © 2012 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Tech Support 864.678.1580 / Website www.aleralighting.com
Recessed / MIR
Modular Indirect Recessed 4-Lamp, TT, T5, T5HO, T8, Indirect Distribution Ceiling Compatibility
Cross section
Type G
Type G 14½", 26½", 38½", or 50½"
Flange Detail
NEMA Type G luminaire for lay-in installation in inverted exposed grid tee ceilings. Maximum tee width is 1".
9"
3¾"
1
473/4" O.A. Trim 48" C.C. Tees
24", 36", 48" or 60" Type F
Type F 26½", 38½", or 50½"
NEMA Type F luminaire has exposed flanges which finish edges of ceiling opening. Concealed suspension by adjustable wing hangers.
9"
3¾"
The flanged MIR is installed by drawing the upper housing (1) into the ceiling by vertically adjustable wing hangers. The lower decorative skirt assembly (2) is then attached and drawn tight against the finished ceiling without the use of tools. Relamping may be done by reaching over the skirt assembly.
1/2" Min. 21/2" Max. (std.)
481/8" R.O. 483/4" O.A. Trim
37⁵⁄₁₆", 49⁵⁄₁₆", or 61⁵⁄₁₆" O.A. Trim
2
Photometric Data
Ballast Ballast Factor Lamp Lumens per Lamp Watts Shielding Angle Spacing Criterion Luminous Opening in Feet
MIR44-4T8G-OCT MIR Architectural Recessed 4' × 4' 4-LAMP INDIRECT LIGHTING MODULE WITH 731-L-TC-P 1.00 FO25/31K 2150 116 0º = 0 90º = 0 0º = 1.30 90º = 1.29 Length: 3.71 Width: 3.71 Height: 0.00
Avg. Luminance (Candela/Sq. M.) Coefficients of Utilization (%) 0 30 40 45 50 55 60 65 70 75 80 85
0.0 22.5 45.0 67.5 90.0
790 790 790 790 791 774 768 774 815 797 792 798 826 813 812 815 848 831 837 837 884 866 864 871 937 918 904 926 1023 997 973 1010 1143 1109 1068 1130 1257 1230 1148 1257 1315 1207 1117 1266 215 395 359 359
790 787 814 831 853 890 946 1033 1159 1272 1329 287
Zonal Lumen Summary Zone
0-30 0-40 0-60 0-90 0-180
Lumens % Lamp % Fixt. 776 1292 2436 3490 3490
9.0 15.0 28.3 40.3 40.6
22.2 37.0 69.8 100.0 100.0
RCR
Luminaire
Angle
Luminaire Data Test 8447
RC RW 1 2 3 4 5 6 7 8 9 10
70 43 39 35 32 29 27 25 23 22 20
80 50 30 41 39 35 32 30 27 27 23 24 20 21 17 19 15 17 14 16 12 15 11
10 37 29 24 20 17 15 13 11 10 9
70 42 38 34 31 28 26 24 23 21 20
70 50 30 40 38 34 32 30 26 26 23 23 20 21 17 19 15 17 14 16 12 14 11
10 37 29 24 20 17 14 13 11 10 9
50 39 33 29 25 22 20 18 17 15 14
50 30 37 30 26 22 19 17 15 13 12 11
10 36 28 23 19 17 14 13 11 10 9
Indoor Candela Plot 0 0 33 26 21 18 15 13 11 10 9 8
RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
90
75
550 60
1100 0
15 0.0
30 Horiz 0-180 45.0
45 90.0
Energy Data Total Luminaire Efficiency Luminaire Efficacy Rating (LER) ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens
40.6% N/A Noncompliant $N/A based on 3000 hrs. and $0.08 per KWH
Test Date 10/24/07
Photometric Data
Ballast Ballast Factor Lamp Lumens per Lamp Watts Shielding Angle Spacing Criterion Luminous Opening in Feet
MIR44-4T12G-LE MIR Architectural Recessed 4' × 4' 4-Lamp Indirect Lighting Module RM-2SP30 1.00 F30T12/WW/RS 2360 162 0º = 0 90º = 0 0º = 1.29 90º = 1.29 Length: 3.71 Width: 3.71 Height: 0.00
Avg. Luminance (Candela/Sq. M.) Coefficients of Utilization (%) 0 30 40 45 50 55 60 65 70 75 80 85
0.0 22.5 45.0 67.5 90.0
810 809 832 843 860 894 948 1033 1159 1269 1324 233
810 810 810 810 791 787 795 807 815 810 818 833 831 827 833 847 848 853 852 867 879 878 885 904 932 917 940 959 1007 983 1023 1044 1118 1077 1141 1166 1236 1160 1260 1269 1202 1121 1270 1320 395 368 359 314
Zonal Lumen Summary Zone
0-30 0-40 0-60 0-90 0-180
Lumens % Lamp % Fixt. 795 1323 2489 3551 3551
8.4 14.0 26.4 37.6 37.6
22.4 37.3 70.1 100.0 100.0
RCR
Luminaire
Angle
Luminaire Data Test 8448
RC RW 1 2 3 4 5 6 7 8 9 10
70 40 36 33 30 27 25 23 22 20 19
80 50 30 38 36 33 30 28 25 25 21 22 18 20 16 18 14 16 13 15 12 14 11
10 35 27 22 18 16 14 12 10 9 8
70 39 35 32 29 26 24 23 21 20 18
70 50 30 37 36 32 29 28 25 24 21 22 18 19 16 17 14 16 13 15 11 13 10
10 34 27 22 18 16 13 12 10 9 8
50 36 31 27 23 21 19 17 15 14 13
50 30 34 28 24 20 18 16 14 12 11 10
10 33 26 22 18 15 13 12 10 9 8
Indoor Candela Plot 0 0 30 24 20 17 14 12 11 9 8 8
RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
90
75
550 60
1100 0
15 0.0
30 Horiz 0-180 45.0
45 90.0
Energy Data Total Luminaire Efficiency Luminaire Efficacy Rating (LER) ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens
37.6% N/A Noncompliant $N/A based on 3000 hrs. and $0.08 per KWH
Test Date 10/24/07 Page 2/2 Rev. 07/25/12 © 2012 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Tech Support 864.678.1580 / Website www.aleralighting.com
Recessed / MIR