For the attention of service and sales personnel.



 

Documents supplied with the heat pump:  Installation instructions DHP-AQ

The change will be introduced in document production in 2012.

System solution DHP-AQ Mini

System solution DHP-AQ Midi

System solution DHP-AQ Maxi

System solution DHP-AQ Maxi with external heater with shunt. Two shunt groups. Accessories are cooling system and swimming pool.

Legend Pos Description

Pos

Description

5

Heat pump unit

80

Shut-off valve

10

Supply line

83

Non-return valve

11

Return line

85

Air bleeding valve

12

Cold water

87

Safety valve (9 bar, WW)

13

Hot water

91

Dirt strainer with shut-off valve

18

Hot water storage tank

96

Flexible hose

21

Volume tank

100

Security valve (1.5 bar)

33

Circulation pump (shunt additional heater)

101

Reversing valve pool

36

Circulation pump (system)

103

Pool heater exchanger

40

Control unit

107

Shunt valve (shuntgroup 1)

50

Outdoor sensor

108

Supply line sensor (shuntgroup 1)

51

System supply line sensor

109

Circulation pump (shuntgroup 1)

52

Return line sensor

112

Expansion vessel (hot gas)

53

Hot water starting sensor

114

Immersion heater

55

Hot water sensor top TWC

117

Additional heater

60

Sensor pool

120

Fan coil

62

Room sensor

133

Shunt valve (shunt group 2)

63

Shunt valve (additional heater)

134

Supply line sensor (shunt group 2)

64

Supply line sensor, mixing valve

135

Circulation pump (shunt group 2)

77

Diverting valve hot water

355

Connecting self-regulating heating cable for draining

79

Reversing valve cooling tank

Legend electrical connections Pos Description

Connect to

5

Heat pump unit

33

Circulation pump (shunt additional heater)

101.2 and N

36

Circulation pump (system)

101.1 and N

40

Control unit

50

Outdoor sensor

51

System supply line sensor

52

Return line sensor

53

Hot water starting sensor

55

Hot water sensor top TWC

60

Sensor pool

208.1 and Com

62

Room sensor

DC to 121.1

305 and Com

A to 121.3 Gnd to Gnd B to 121.5 63

Shunt valve (additional heater)

+102.3 -102.4 and N

64

Supply line sensor, mixing valve

118.2 and Com

79

Reversing valve cooling tank

M3.3 to L1:1 M3.6 to 101.6 M3.2 to N

101

Reversing valve pool

M3.3 to L1:1 M3.6 to 201.1 M3.2 to N

107

Shunt valve (shuntgroup 1)

+102.5 - 102.6 and N

108

Supply line sensor (shuntgroup 1)

118.3 and Com

109

Circulation pump (shuntgroup 1)

101.3 and N

114

Immersion heater

L1, L2 and N

117

Additional heater

101.4 and N 230Vac out / alt. pot free relay max in 250V 8A connect in 101.8 out 101.16

120

Fan coil

133

Shunt valve (shunt group 2)

+202.1 - 202.2 and N

134

Supply line sensor (shunt group 2)

208.3 and Com

135

Circulation pump (shunt group 2)

201.5 and N

355

Connecting self-regulating heating cable for draining

L1.1, PE and N

Updated table for Wiring diagrams 1

Heat pump

5

Het pump unit

36

Circulation Pump

40

Control unit

50

Outdoor sensor

51

Supply line sensor

52

Return line sensor

53

Hot-water sensor start

55

Hot-water top sensor

62

Room sensor

69

Shunt group

71

Flow guard

107

Shunt valve (shuntgroup1)

108

Supply line sensor shuntgroup1

109

Circulation Pump shuntgroup 1

114

Immersion heater

301

Compressor

302

Brine pump

303

Radiator pump

305

Fan

306

System Circulation Pump

310

Reversing valve

311

4 Way Valve

312

Bypass Valve

313

Electronic Expansion Valve

340

Temperature guard

341

Thermal overload relay

342

Circuit breaker

343

Line circuit breaker

344

Alarm relay

350

Soft start

351

Capacitor

353

Drip tray heater

354

Compressor Heater

355

Connection of electical drip tray cable to draining valve

362

Shunt valve control

363

Reversing valve hot-water

364

Shunt valve hot-water

367

System Shunt

369

Pool Heating Valve

370

2nd Distribution Circuit Pump

371

Auxiliary heating Oil/El

372

Auxiliary Top heating

373

Distribution Circuit Shunt 2

403

Operating pressure switch

405

Heating out sensor

407

HGW sensor

408

EVU

410

Hot-water

411

Heating return sensor

412

Brine out sensor

413

Brine in sensor

414

High pressure switch

415

Low pressure switch

416

Discharge pipe sensor

417

Defrost sensor

418

Refrigerant 1 sensor

419

Refrigerant 2 sensor

420

Pressure transmitter

421

Suction gas sensor

422

Dewpoint Sensor

423

Sensor pool

424

Sensor cooling

425

Sensor Buffer Tank

426

Sensor System Supply Line

428

Sensor Distribution Circuit 2

451

Control unit

452

I/O controller

453

Display

454

Electronic Expansion Valve controller

455

Indoor hub controller

456

Current Limiter

* Note 1

Strapt at delivery

* Note 2

blue

* Note 2

brown

* Note 2

grey

* Note 2

green

* Note 2

yellow

* Note 2

violet

* Note 2

pink

* Note 2

red

* Note 2

black

* Note 2

white

* Note 3

Note! Can be connected to 230V single phase if auxiliary heater is disconnected.

* Note 4

Note! When connected to 230V single phase straps to auxiliary heater shall be removed.

* Note 5

NOTE ! Remove jumper when using separate supply of control circuit

* Note 6

NOTE ! Remove jumper when using flowguard

* Note 7

Overload relay trip/triped out

* Note 8

Alarm

* Note 9

Speed control

* Note 10

Please make sure that all supply lines are disconnected

before attending any work to internal electrical parts! * Note 11

Fan Overload relay

* Note 12

To indoor unit

* Note 13

To slave unit

* Note 14

To Electronic Expansion Unit

* Note 15

Immersion heater or external auxiliary heater

* Note 16

Potential free contact

* Note 17

To Outdoor unit

* Note 18

To Expansion Unit

* Note 19

Communication

Sensors and electrical connections Connecting outdoor sensor (5)

Connect the outdoor to the control unit

Connecting supply and return pipe sensors

Connect supply line sensor

Connect return line sensor

Connecting supply line sensor shuntgroup1

Connecting sensors to external water heater

Connect hot water sensor top

Connect hot water sensor start

Connecting room sensor

Connecting system circulation pump

Connect the system circulation pump

Connecting circulation pump shuntgroup1

Connect circulation pump shuntgroup1

Connecting heating cable drip tray

Connect the electrical drip tray cable heat pump

Connect control signal to circulation pump with variable speed

Connecting shunt valve shuntgroup1

Connect circulation pump cable shuntgroup1 AC 230V

Connecting the communication cable UV-resistant twisted pair data /telephone cable for outdoor use Screened cable with the screened connection at the end of the earth terminal Maximum cable length is 30 meter

Heat pump

Control unit

Connection power supply (40)

Connect 400V 3-N

Connecting immersion heater cable

Connecting immersion heater cable

Connecting sensor swimming pool

Connect sensor swimming pool

Connecting sensor shuntgroup2

Connect sensor shountgroup 2

Alternative connect 230V 1-N