TÜV RheinlandProduktund UmweltGmbH
ReportNo.30004467 concerning efficiencyInvestigations into the Air PurifierVIKTOR designedby StadlerFormAG with regardto changein air quality
I I I I I I I
A
www.tuv.com
D^ TUVRheinland@
I A
BusinessStreamProducts Analvsis Productand Environmental
)
I I I I I I I I
25.11.2009
TUV AssignmentNo.: 30004467
tüvnneintand@ Genau.Richtig.
Page 1 of 12
BERICHT concerning efficiencyInvestigations into the Air PurifierVIKTOR designedby StadlerFormAG with regardto changein air quality
t Fg'
E
r€ Fg r; FE rä F!
Client:
StadlerFormAktiengesellschaft Chamerstrasse 174 6300Zug
Assignment dated:
28.10.2009
No.: TÜVAssignment
30004467
MeasuremenVon-site meetingdate:
0 4 . 1 1- .1 0 . 1 1 . 2 0 0 9
Sampler:
BjörnKoch/And16Bohnstengel
Processor:
BjörnKoch(Tel.:02211806-1 302) tÜV nneinland Produkt undUmweltGmbH Protection Hazardous Substances and Industrial Group
Object:
Examination of the efficiency Air PurifierVIKTORdesignedby (0.3 StadlerFormAG withreference to the reduction of particles airandin theozoneemission. ;rmand0.5pm)in ambient
E €
3
E
fs lz
g
f*
F; g g
lä Ei
6 l
tE Fg .-r'?
!
!" oi
lB
i
I I
BusinessStreamProducts Productand Environmental Analysis
t I I
25.11.2009
TUVAssignment No.:30004467
tÜvnneinland@ Genau.Richtig.
Page2 of 12
TABLEOF CONTENTS PAGE
t I I
BRIEFSUMMARY
3
1
4
ASSIGNMENTOF TASKS
2 BASES 2.1 Ozonetest accordingto DIN EN 600335-2-65 2.2 P articlemeasurement
t T T, E
r€ Fg ö €
r* rä rä F!
t
ft
rä o g
ri l
;;
lH
3 3.1 3.2 3.3
IMPLEMENTATION Air PurifierVIKTOR Recordingof particlesizes0.3 pm and 0.5pm by meansof Model227 B Recordingof ozoneconcentration
4 4 4 5 5 6 7
4 RESULTS 4.1 Recordingof particleconcentration
I 10
5 ASSESSMENT OF THE RESULTS 5.1 Recordingof ozoneconcentration 5.2 Recordingof particleconcentration
12 12 12
I
t T T -
described the useof the Air PurifierVIKTORdesignedby StadlerForm Underthe conditions in air quality.Due to its efficiency AG led to an improvement the air purifieris suitablefor purifying air in respectof particlereduction, for officespacesfor example(approx.50 m")and requirements. canbe recommended underconsideration of statutory
I
I;
rE Ii
E
5 €
t; I:
g
_q IE IT 5 lI Eq
g
-€ Iä
I; ä
rg I;
'6 f
P
t=
I" t8
lr*
r-e
BRIEFSUMMARY
The resultsshowedthat due to the operationof the air purifier,air qualityin respectof particlesizes0.3 pm and 0.5 pm improves. The reduction of numberof particles 0.3 prmand pm particles stoodafterapprox.24 hoursat approx.90 % of the numberof from the 0.5 valueat the beginning of the measuring departure series.
I
rI 5i -a
Page3 of 12
Recording of particleconcentration
-
rIP
Genau.Richtig.
Therewasonlya low-grade 03 concentration in thetestspace.Measurements at the device's air outletconfirmthattheAir Purifierdesignedby StadlerFormAG produces hardlyozone.
I
-2
TUV AssignmentNo.: 30004467
tüvnneintand@
Recordingof ozoneconcentration
-
rE
25.11.2009
A
By orderof StadlerFormAG TUV RheinlandProduktund UmweltGmbH conductedon 04.11.- 10.11.2009 ambientair measurements in orderto examine the Air Purifier VIKTOR (0.3and 0.5 pm) in of particles designedby StadlerFormAG withreference to the reduction The intention wasto proveefficiency. theambientair andin theozoneemission.
-
Ig
BusinessStreamProducts Analysis Productand Environmental
I
I I
BusinessStreamProducts Analvsis Productand Environmental
A
tüvnrreinland@ Genau.Richtig.
25.11.2009
1
-
TÜVAssignment No.:30004467
Page4 of 12
ASSIGNMENT OF TASKS TÜV RheinlandProduktund UmweltGmbHwas assignedby StadlerFormAG on withambientair measurements in orderto examinethe Air PurifierVIKTOR 04.11.2009 of particles(0.3pm and designedby StadlerFormAG with reference to the reduction 0.5 pm) in the ambientair and in the ozoneemission.The intentionwas to prove efficiency.
-
-
Withinthe contextof a practicaltest 1 air purifierTypeVIKTORdesignedby Stadler FormAG wasto be operatedin an officespace(approx.50 m').
F -
F
BASES
F
In total 1 air purifiertype V|IKTORdesignedby StadlerFormAG was operatedall Levels(Level1-5).
F
2 . 1 Ozonetest accordingto DINEN 600335-2-65 generated mustnotbe excessive. Theozoneconcentration thoughionization
Fp
ti Fs
E E
o
ö
fE
F E3
rä Fi
rg l-i
!:
r* E; ä
te EE
;
llE E4 -'=
!
ll'
l$
of 2.5 m x 3.5 m x 3.0 m, Test:Thetestis carriedout in a sealedroomwithdimensions film. The air purification systemis the walls of which are coveredin polyethylene and tabletopdevicesare positionedin the switchedoff as per the user instructions centreof the roomabout750mm abovethefloor. at about 77"F and 50o/o The environmental conditionsin the room are maintained relativehumidity. The unitis operatedwitha ratedvoltagefor24hours,withorwithout filterdepending a removable on whatis mostinconvenient. in the air flow,50 mm fromthe unit'sair The ozonemeasuring cylinderis positioned outlet.The basicozoneconcentration determined beforethe test is deductedfromthe maximum concentration measured duringthe test. mustnotexceed5 x 10-8 (50 ppbor 100pg/m3). Theozoneconcentration
2.2 Particlemeasurement were also conductedon particleswith a size of 0.3 pm and 0.5 pm Measurements described in section 2.1. undertheconditions
I I I I I I I I I I I
BusinessStreamProducts Analvsis Productand Environmental
E E
e o
{IO
I:
FE !
o
-5
I6 I' r-9 E c l
rI I=
9,
I- zq fi I_9 -ö I> o o
s rJ6 -q)
IA
f,s
6 l
{:
I5 Iw d l F
-'= I@
'{B IS
r
IMPLEMENTATION
(i)ai,ro
{- rE II
- !
Page5 of 12
3.1 Air PurifierVIKTOR
FP,
FE
Genau.Richtig.
TUV AssignmentNo.:30004467
25.11.2009
3
Atüvnrreinland@
3
B'
I
t
BusinessStreamProducts Productand Environmental Analysis
I I
25.11.2009
TUV AssignmentNo.:30004467
tüvRtreintand@
A
Genau.Richtig.
Page6 of 12
3.2 Recordingof particlesizes0.3 pm and 0.5pmby meansof Model227 B
t
The Met One227 Handheld AirborneParticleCounterfeaturesthe sensitivity of larger instruments andeasyhandheld Weighingonlytwo pounds,the 227features operation. (2278)or a 0.5 micronsensitivity (227A),and usesreliablelaser a 0.3micronsensitivity diodetechnology.
t
tT
!T I
t l, t. o c
E
The Met One 227 countstwo sizesof particles;the secondsize is userselectable. Configuresampletimesfrom one secondup to 24 hours.To makethe most of its portability, the 227 featuresseveralcountingmodesfor quickanalysisof cleanroom conditions. mode:Givesa continuously Concentration updatedapproximation of the numberof particles perliteror cubicfoot.Theapproximation is basedon a user-selectable sample periodof oneto ten seconds. Auto mode:Automatically takesa specifiednumberof samplesand stops,allowing unattended operation. Averagemode: Calculatesthe average,minimum,and maximumcount after a numberof samples. specified Beepmode:Soundsa beepeachtimeit countsa specified numberof particles. To protectcleanrooms, the Met One 227 containsan exhaustfilter.The pumpand sensorare turnedoff when the batterychargedropsbelowa safe operatinglevel, powerto preserve maintaining datastoredin memory.
.E N C o
.9 o
o
E
o ! o
f, c o
E I
l
o c f
z i!
ti, ;o
o o o o a
i:
l F
T U l F
t
:]F
t
ö
@
Printresultsto a remoteprinteror downloaddatato a computeror facilitymonitoring system.Use PortAllVersion2 softwarewith the 227 to scheduleautomateddata collectionof particle counts. Track and identify trends to eliminate particle contamination sources.
I I
Atüvnrreintand@
BusinessStreamProducts Productand Environmental Analysis
Genau.Richtig.
t _=
25.11.2009
I
3.3
I i i I I i i
U'
TechnicalData:
I;
c
Gas:03 (ozone) principle. Measuring
electrochemical three-electrode sensor
Measuring range:
0 . . . 3 0 0p p b
Detection limit
20 ppb
Accuracy:
typically5o/oof final value undernominalconditions(for intermittentoperation)
Longtermaccuracy:
after12 monthsundernominalconditionstypically5o/oof final value(for intermittentoperation)
period: Exposure
untilspecification is reached,at least2 hours(at 200 ppb); prolonged period for a the devicewas in an ozone-free environment
Meas.interval:
p u m po n : S m i n pumpoff: 1Omin
Pumpflowrate:
500m|/min
Signaloutput:
0 ...2v,
E E
-I TE I!
-. r.g IE -€
'€o o o
r! Ib
-I ä 9
> 100kO loadresistance
I !
IE If, -2
in
Powersupply:
pump off :25 mA, typical pumpblocked: 180 mA, typical
o
s rq) I; Io a l
Overloadcapacity:
1 ppm
Expectedusefullife :
Sensor,typically24 months ( a t2 0 ' C ) pump,typically6000 hours
Nominalconditions:
2 0 " C , 3 0 %r . H . ,1 0 1 3m b a r ,
l F
-.? I@
-
E tB IS -
6 to 14V,stable
pumpon : 50 mA, typical Current consurhption:
-c
I-9 Iä I>
I! I; I> -U
Page 7 o'f12
Recording of ozone concentration
-
-I oö
TUV AssignmentNo.: 30004467
A
BusinessStreamProducts Analysis Productand Environmental
4
Genau.Richtig.
Page8 of 12
TUV AssignmentNo.:30004467
25.11.2009
tüvnneintand@
RESULTS Date:
Time Level
Recording of particlesizes
0,3
0,5
OzoneConcentration Ozon ppb
Ozon Safety ug/m' Value
Temp in oC
RHin o/o
ozoN
in oob
04.11.2009 1 1 : 3 5 Level 1 12:40 Level 1
13:45 Level '1 14:40 Level 1 1 5 : 3 0 Level 1 05.11.2009 07:50 Level 1 08:55 Level 1 1 1 : 3 5 Level 1 Reduction 24h
0 5 . 1 1 . 2 0 0 9 09:50 Level 2 1 0 : 5 0 Level2 1 1 : 5 0 Level2 12:55 Level2 14:10 Level2
1 5 : 1 0 Level2 Reduction
1 5 : 5 0 Level2 6h
06.11.2009 07:50 Level5 09:00 Level 5 09:50 Level 5 1 0 : 5 0 Level 5 1 1 : 5 0 Level 5 1 3 : 1 0 Level 5 Reduction
14:50 Level5 7h
123.193 15.324 11 0 . 3 0 0 1 3 . 6 3 6
0 0
59.890 26.738 58.271 3 1. 10 8 9.165 8.536
6.686
1 1
93,1 o/o
93,4o/o
123j93 7.824 7.548
15.324
6.300 5.800 5.763 4.865 96,1 o/o
3.041 5.747
2
3.570
4
1.376
4 4
1.010
0 0 2 2 4 8 8 6
50 50 50 50 50 50 50 50
969 942 808
2 2 2 2
722
4
8
50 50 50 50 50 50 50
6 6 6
12 12 12 12 12 12 12
50 50 50 50 50 50 50
1.062 1.012
4 2
8 4 4 4 4
4
23.5 23,6 23.6 23,6 23.6 23,7 23.7 23,7
48,1 48,1 48.6 48,5 48.7 47,O 47 47.1
23,7
47,2 47,O 47,1 47.5 46,9
23.7
23.6 23.7
23,7 23.7
47.2
23.7
47,0
23.7 23,8 23,9 23,9 23,9 23.9 24.0
46.8 46,8 46,8 46,8 46,8 47.2 46,6
95,3 %
123.193 15.324 27.116 3.081 19.318 8.668 7.661 9.465
2.187 781 721 1.525
92,3 o/o
90,0%
o
6 6 6
I I I I I I I I I I I I
Date:
Time
Level
Recording of particlesizes
0,3
0,5
tüvnneintand@ Genau.Richtig.
Page9 of 12
OzoneConcentration Ozon ppb
Ozon Safety pg/m' Value
Temp in oC
RHin %
23.1 23.1 23,2 23.2 23,2 23.2 23,2 23,2
45.7 45,6 45.6 46,4 45,8 45,9 46,0
23,0 23.0 23.1 23,1 23,1 23.1
46,8 46,5 46 46.8 46,7 46.8 46,9 46.8 46,9
ozoN in ppb
0 9 . 1 1 . 2 0 0 9 07:55 Level3 09:00 Level3 1 0 : 0 0 Level 3
Reduction
1 1 : 0 5 Level 3 1 2 : 1 0 Level3 1 3 : 0 0 Level 3 1 4 : 0 0 Level 3 1 5 : 0 0 Level3 1 6 : 0 0 Level3 8h
1 0 . 1 1 . 2 0 0 9 08:22 Level4 0 9 : 1 5 Level4 1 0 : 1 0 Level4 1 1 : 0 5 Level4
Reduction lppb=2pglm3
z
I
I I
I I
I I I
TUVAssignment No.:30004467
25.11.2009
I I I I
A
BusinessStreamProducts Analysis Productand Environmental
l
l
128.468 93.768 45.382
18.067 12.516
25.324
5.235 3.048
18.496 11.668 9.840 6.988
1.385 778 741 654
94,6 o/o
96,4 o/o
123.193 15.324 39.104 2.524 22.407 1 . 7 0 9 13.599
1.346
12:10 Level4 1 3 : 0 0 Level4
37.223 35.008
2.962
14:05 Level4 1 5 : 0 5 Level4 1 6 : 0 0 Level4 8h
42.797 21.687 12.245
7.163 5.674 5.140 1.896
90,1 o/o
87,6 o/o
6 6 6 6 6 6 6 6
12 12 12 12 12
12 12 12
0
0
6 4 4 6 6 6 6 6
12 8 8
12 12 12 12
12
50 50 50 50 50 50 50 50 50
50 50 50 50 50 50 50 50 50
1 23,1
23,2
46,2
I
a
BusinessStreamProducts Analysis Productand Environmental
Atüvnrreinland@ Richtig. Genau.
I
t t t
25.11.2009
4.1 Recordingof particleconcentration Reduction of Particle Concentration 0,3 Pm 140.000 120.000
a I
! roo.ooo G
5 8o.ooo o o
o
o o
60.000
E 4o.ooo
o.
20.000
t
0
I I
Reduction of Particle Goncentration 0'5 ;lm 20.000
l= ft E
ri rä ri
l!
Page 10 of 12
No.:30004467 TÜVAssignment
o it
ft
rä o o E
il
IE
FF
t: la
lB
18.000 16.000
'! ra.ooo to rz.ooo
--.-Le\el
G
(, E 1o.0oo o Sa)
8.000
E r
6.000 4.000 2.000 0
1
---r-Lewl Lewl
--x-Lerel 4 --x- Lerel 5
I )
A
A
BusinessStrearnProducts ProductandEnvironmental Ana{ysis
TUVRheinland@ Genau.Richtig.
)
I I I I
t I I
25.11.204s
TÜV Assignment No.: 30004467
1 +Le\el +Level 2 r Lercl 3 -+FLelel 4 +Le\,el 5 -+SabtyValue
Page 11 olf12
EN
,
I T T T
T T
T I
t
25.11.2009
TUVAssignment No.:30004467
tüvnrreinland@ Genau.Richtig.
Page 12 of 12
OF THERESULTS 5 ASSESSMENT 5.1 Recordingof ozoneconcentration in the test space.Measurements at the Therewas onlya low-grade 03 concentration Air Purifier VIKTOR designed by Stadler Form AG air outlet confirm that the device's produces hardlyozone.
5.2 Recordingof particleconcentration The resultsshowedthatdue to the operation of the air purifier,air qualityin respectof particlesizes0.3 pm and0.5 pm improves. The reduction of numberof particles 0.3 pm and 0.5 pm stoodafterapprox.24 hoursat approx.90 % of the numberof particles valueat the beginning of the measuring series. fromthe departure
the useof the Air PurifierVIKTORdesignedby StadlerForm described Underthe conditions in air quality.Due to its efficiency the air purifieris suitablefor AG led to an improvement purifying for officespacesfor example(approx.50 m2)and air in respectof particlereduction, requirements. underconsideration of statutory canbe recommended
I
The Expert
BjörnKoch
I
A
BusinessStreamProducts Analysis Productand Environmental
ö
Professional ly responsible