6 December 2000

Dec 6, 2000 - ADHERENCF. HYDRAULIC + SLOTTED TAPE. /. WARNING! The statement of the levels, distance DO-Dl has a value. 1,4 times lower than the.
676KB taille 14 téléchargements 205 vues
6 December 2000

This manual is deemed correct on going to press.

The informa,tion contained has been scrupulously checked. However AUTINOR declines al1 responsibility for error or omission.

Should you notice any discrepancy or unclear description, or if you have any suggestions, we would appreciate your written comments (by mail or fax) to: Société AUTINOR - Service Documentation Z.A. Les Marlières 59710 AVELIN

n S

[33103-20-62-56-00 [33] 03-20-62-56-41

IXI

[email protected]

This manual is the property of AUTINOR, from whom it may be bought (at the above address). It may however by freely copied in order to communicate information to those who might need it. We can only authorise a complete copy, without neither addition nor removal of information Where quotations are taken, the following at least must be noted:

-

The Company name of AUTINOR,

-

The number and date of the original edition.

O Copyright 2000 AUTINOR Al1 rights reserved.

.&Documentation Dpt

page 5

LlFT AT SPEED SUPERIOR HAS 2,5 mls CONCERNING THE SOFTWARE:

For a 32 series, use traditional software for BG15 board SLOTTED TAPE SELECTOR SLOTTED TAPE ADHERENCF

l

HYDRAULIC + SLOTTED TAPE /

WARNING!

The statement of the levels, distance DO-Dl has a value 1,4 times lower than the real distance from the magnet.

For a 191 series, use traditional software for N I 0 board

1

SLOTTED TAPE SELECTOR

~ WARNING!

The statement of the levels, distance DO-Dl has a value 1,4 times lower than the real distance from the magnet.

For a frequency drive, use ARBVOG software for VECOl board WARNING!

Distance DV2 is used to position the magnet ED. To program the segment 3 address OOE (currently called MLI)

@ Documentation Dpt

FIXING THE SLOTTED-TAPE AND BRACKETS

page 6

.@' Documentation Dpt

page 7

POSlTlONlNG THE EM MAGNET ON THE SLOTTED TAPE .......

I

............

.................

- --

ZONARM UP STOPPING ZONE

ZDEVER UP DOOR UNLOCKING ZONE

------------------------------------..-.-. -.-. . .

UP SLOW SPEED ZONE

003-2

ZONE PV Tape-head DOWN SLOW SPEED ZONE

DOWN SLOW SPEED ZONE

FLOOR F-1

...........................................................

.............................

-

............................

UP SLOW SPEED ZONE

DOWN SLOW SPEED ZONE

BOTTOM FLOOR O

UP SLOW SPEED ZO

,& Documentation Dpt CONNECTING OF TAPE HEAD 003-2