Wind farm Information Sheet: Penquer 1 | Wind Turbine Identification # of WEC's Country Hub height TOC date
6 turbine(s) of 2 MW each France 78 01/01/2011
Total Power Wind turbine Type Wind farm availability Target Location number reference
Windmill Park
Penquer
Legal entity
Park Location Gurunhuel
Unique Id 0083 0084 0079 0080 0081 0082
Moustéru
Windmill Number 5 6 1 2 3 4
Windmill Name 5_Penquer 6_Penquer 1_Penquer 2_Penquer 3_Penquer 4_Penquer
12,0 MW E82 E1 97% Loc_3708 Elicio Bretagne SAS 30, Boulevard Richard Lenoir 75011 Paris 509111617 Serial Number 822169 822170 822165 822166 822167 822168
2 | Substation and Off-Taker
Grid operator
ERDF (Enedis)
Notes Tel.: 0033 298 36 48 03 situee: Penquer 22200 Mousteru n° siret: 509 111 613 00014 poste de livraison: Penquer 1 départ: Penquer 1 direction: guingamp n° poste: 22156P8000 Penquer n° GDO: 22156P8000 Chargé d'Exploitation du Réseau Public de Distribution
[email protected] and 0033 298 21 27 48 Chargé de Conduite du Réseau Public de Distribution
[email protected] and 0033 298 36 48 03 Serveur d'information sur l'avancement du dépannage du Réseau Public de distribution: 0033 811 88 22 02
ACR : 02 98 36 48 03 Enercon
Off-Taker
EDF
Production control
Enedis (ERDF) – mail to
[email protected] Monthly data
[email protected] à day 3 10'data via ERDF - mailMail from
[email protected] à +/-day 6 in the evening
Confidential
Responsibility
3 | Access Site
Enercon Service Ouest +33 (2) 28 09 49 34
CARDI: 145330 Compteur Capfile: 607
[email protected] Sylvie RALU (
[email protected]) Email :
[email protected] n° de téléphone (n° AZUR) : 0033 9 69 32 18 00
Wind farm Information Sheet: Penquer
Wind farm Information Sheet: Penquer Notes Local content Snow removal
Green maintenance
Turbine Service provider Key(s) turbine(s) Key(s) substation
Romain Ledunois Not applicable
ESATCO Pen Duo - Plouisy
+33 776 06 25 76 ESATCO SITE DU PAYS DE GUINGAMP (ESAT) >> PEN DUO 22200 Plouisy 02 96 40 11 70 02 96 44 01 82 accueil.guingamparobase.pngesatco.fr
Enercon Service Ouest +33 (2) 28 09 49 34 Enercon 16128HS_3HE3 C RC/OUE 113
Confidential
ADSL - internet: Orange business services: 0800 018 028 n° compte internet: 121303048 n° client: 80 40 19 048
Orange
Serial Number
lignes analogue: Orange Pro: +33 9 69 36 39 01 adsl: 02 96 11 10 74 ligne non attribué: 02 96 11 10 09 soutirage: 02 96 11 10 73 (responsibility enedis) DEIE: 02 96 11 10 08 (responsibility enedis) n° client: 01 57 18 85 43 espace client: adresse mail:
[email protected] mot de passe: 2dtzuhx tester la ligne: https://tester-depanner-vos-services.orange.fr ou suivi-des-incidents.orange.fr contact email:
[email protected] Access address
Site & contacts
822165
Moustéru D20
Haspot Théophile, Route de la rivière du sant - 81110 Massaguel (E3) HASPOT Nicole, Saint Croix - 48 rue Penquer - 22200 GUINGAMP (E3) Not applicable Carre Yvon, Penquer - 22200 MOUSTERU (poste de livraison, loyer fermage)
822166
Moustéru D20
(vide)
Not applicable
822167
Moustéru D20
(vide)
Not applicable
822168
Moustéru D54
822169
Gurunhuel D20/D54
822170
Gurunhuel D20/D54
Access codes and notes
Carre Yvon, Penquer - 22200 Not applicable MOUSTERU Morvan Guy, Guern Ar Oualc'h Not applicable 22390 Gurunhuel le Men Annick, Lan Guébiou - 22390 Not applicable Gurunhuel
GPS coordinates
N 48°32'38,010" W 3°15'36,245"
N 48°32'28,436" W 3°15'38,659" N 48°32'17,431" W 3°15'43,029" N 48°32'7,175" W 3°15'43,907" N 48°13'56,632" W 3°15'46,259" N 48°31'47,894" W3°15'48,336"
Wind farm Information Sheet: Penquer 4 | HSE Serial Number
822165
Confidential
822166
Actual noise reductions 22h-7h 0° - 180° 7,5 m/s < wind speed < 9 m/s mode IV 9 m/s < wind speed < 10,5 m/s 600 kW 180° - 360° 7,5 m/s < wind speed < 10,5 m/s 400 kW 0° - 360° 10,5 m/s < wind speed < 13 m/s 600 kW
22h-7h 0° - 360° 7,5 m/s < wind speed < 13 m/s 830 kW
Shadow activation
no
no
822167
22h-7h0° - 360°7,5 m/s < wind speed < 13 m/s 830 kW yes
822168
22h-7h0° - 360°7,5 m/s < wind speed < 13 m/s 830 kW no
822169
22h-7h 0° - 360° 7,5 m/s < wind speed < 9 m/s 400 kW 9 m/s < wind speed < 10,5 m/s 800 kW 10,5 m/s < wind speed < 13 m/s 1000 kW 10,5 m/s < wind speed < 13 m/s mode IV
no
822170
22h-7h 0° - 360° 7,5 m/s < wind speed < 13 m/s mode IV
no
Ice sensors_ Settings_Preventive measures
Aviation and beaconing AVIATION LIGHT AIP : E2213 48°32'23 N Labko: NO 003°15'40 W Wind speed tollerance: Standard Red flash on the nacelle: 2 x 2000cd Special settings/procedures: NO White flash on nacelle: 2x 20000cd ICE Warning sign: No red flash on tower: 0 red band on the blade: 0 red band on the tower: 0 AVIATION LIGHT AIP : E2213 48°32'23 N 003°15'40 W Red flash on the nacelle: 2 x 2000cd Labko: NOWind speed tollerance: StandardSpecial settings/procedures: NOICE Warning sign: White flash on nacelle: 2x 20000cd red flash on tower: 0 red band on the blade: 0 red band on the tower: 0 AVIATION LIGHT AIP : E2213 48°32'23 N 003°15'40 W Red flash on the nacelle: 2 x 2000cd Labko: NOWind speed tollerance: StandardSpecial settings/procedures: NOICE Warning sign: White flash on nacelle: 2x 20000cd red flash on tower: 0 red band on the blade: 0 red band on the tower: 0 AVIATION LIGHT AIP : E2213 48°32'23 N 003°15'40 W Red flash on the nacelle: 2 x 2000cd Labko: NOWind speed tollerance: StandardSpecial settings/procedures: NOICE Warning sign: White flash on nacelle: 2x 20000cd red flash on tower: 0 red band on the blade: 0 red band on the tower: 0 AVIATION LIGHT AIP : E2213 48°32'23 N 003°15'40 W Red flash on the nacelle: 2 x 2000cd Labko: NOWind speed tollerance: StandardSpecial settings/procedures: NOICE Warning sign: White flash on nacelle: 2x 20000cd red flash on tower: 0 red band on the blade: 0 red band on the tower: 0 AVIATION LIGHT AIP : E2213 48°32'23 N 003°15'40 W Red flash on the nacelle: 2 x 2000cd Labko: NOWind speed tollerance: StandardSpecial settings/procedures: NOICE Warning sign: White flash on nacelle: 2x 20000cd red flash on tower: 0 red band on the blade: 0 red band on the tower: 0
No
No
No
No
No