AXYS T-2212 data sheet rev 1.1 / GvB / Dec. 15th 1995
T-2212 Architectural and engineering specifications The loudspeaker unit shall be of the two-way active type with integrated electronics, two 12” low/mid speakers and one 2” ferrofluid cooled driver with carbon-fiber diaphragm. Specially developed horns made of fiberglass reinforced epoxy and coated in order to dampen resonance’s shall be mounted on each transducer. The horns shall have an exponential area increase and a constant directivity over a wide frequency range. Arrayability shall be guaranteed by a well defined frequency independent horizontal opening angle in exact correspondence with the shape of the cabinet. The complete electronics shall be mounted on a chassis which is placed in a separated part at the backside of the enclosure. Electronics shall consist of active filters to implement crossovers and equalization, protection circuitry and three power amplifiers coupled to two independent power supplies. The filter section shall include a ‘cluster configuration’ switch which enables the user to compensate for coupling effects in the low-mid frequency range when using multiple unit clusters. Protection shall consist of two Dynamic Level Control (DLC) circuits that limit the dissipated mean power of the transducers to a safe value, DC protection on each of the amplifier outputs, high chassis temperature and high voltage on the mains supply. A LED on the front and rear side shall display the status of all protection circuits. The balanced signal input connector shall be a 3p female XLR type (p2 = +, p3 = -, p1 = gnd), the full-range signal output link connector shall be a 3p male XLR type (p2 = +, p3 and p1 = gnd). A hard-wired bypass relay guarantees the signal transfer to the link output in any condition. A mains voltage switch (115/230 V) shall be implemented on the outside of the unit and the mains connector shall be a male DO-3 type. All connectors shall be grouped together at the lower side of the chassis. The enclosure shall be constructed of laminated birch plywood reinforced with bracing and two internal aluminum frames to which eight rigging frame attachment tracks are connected (four on top and four on the bottom). It shall contain six recessed handles and shall be trapezoidal shaped to facilitate the construction of clusters. A passive convection system shall ensure an efficient transfer of the heat generated by the transducers and the electronics. The front of the enclosure shall be covered with open cell foam mounted on a protective perforated steel grill. The enclosure shall be finished with a polyurethane coating. The complete loudspeaker unit shall meet the following performance criteria: Frequency range of 130 - 18k Hz on axis (+/- 3 dB), max. SPL at 1m of 136 dBSPL continuous and 139 dBSPL peak, - 6 dB coverage angle of 35o horizontal by 32o vertical averaged 1k to 15k Hz. Dimensions are 56.7” (1440 mm) H x 21.3” (540 mm) W x 26.4” (670 mm) D, trapezoidal shaped. Weight 203 lbs. (92 kg). The loudspeaker unit shall be the AXYS model T-2212.
1
AXYS T-2212 data sheet rev 1.1 / GvB / Dec. 15th 1995
Specifications1 2
Acoustical : Frequency range Max SPL (1m)
3
Coverage angle
: 130 - 18k Hz (+/-3 dB) - Continuous - Peak
: 136 dB : 139 dB
4
o
o
: 35 H x 32 V
Self generated noise SPL (A-weighed, 1m)
: 34 dB
Electrical: Input
- Sensitivity (120 dBSPL/1m) - Impedance (balanced) - Connector (XLR female type)
: -15 dBu : 20k Ω : p2=+, p3=-, p1=gnd
Link
- Impedance - Connector (XLR male type)
: 300 ### : p2=+, p3 and p1=gnd
Cross-over
- Type - Frequency (-6 dB) - Control switch
: 24 dB/Oct HF, 18 dB/Oct MF : 80 Hz LF-MF, 1k7 Hz MF-HF : 3 step ‘cluster configuration’
3
Power amplifiers
: 3 x 220 Wrms (8 ###)
Protection
: multi band o : Theatsink> 80 C : over / under voltage
Mains
- DLC - Thermal - Mains voltage guard - DC per amplifier - Hard-wired bypass 5
- Voltage (+5/-10 %) - Connector type - Fuses (slow type) - Power consumption
: on link output : 115/230 V switchable : DO-3 male : 2 x 6.3 A and 2 x 100 mA : 40 Widle / 600 Wfull load
General: o
Temperature range (ambient)
: 0 - 40 C
Transducers
: 2 x 12” / 1 x 2” all horn loaded
Dimensions (H x W x D)
: 1440 x 540 x 670 mm
Weight
: 92 kg
Notes: 1 Specifications are valid for 1 unit with ‘cluster configuration’ switch at position 1. 2 Measured under anechoic ‘full-space’ conditions unless stated otherwise. 3 Measured with gated sine waves. 4 -6 dB, average value 1k - 15k Hz. 5 Other voltages available upon request
2
AXYS T-2212 data sheet rev 1.1 / GvB / Dec. 15th 1995
Acoustical data table
Frequency1 (Hz)
125 250 500 1k 2k 4k 8k
DI2 (dB)
Hor. coverage - 6 dB (deg) 3.6 6.1 10.3 14.6 14.1 15.9 16.8
220 180 105 60 53 41 35
Vert. coverage - 6 dB (deg) 165 115 55 32 27 44 37
1. All frequencies octave band centered, all values measured with ‘cluster configuration’ switch at position 1. 2. Directivity Index calculated from horizontal and vertical polar data. 3. Peak values measured with gated sine waves under anechoic conditions, scaled to 1m ETC time zero.
Directivity Index
T -2212 D irectivity Index 20 15 dB 10 5 0 100
1000
10000
Hz
3
Max. SPL at 1m3 (dBSPL) 128 135 137 139 138 135 129
AXYS T-2212 data sheet rev 1.1 / GvB / Dec. 15th 1995
SPL response
T -2212 100 95 90 85 80 dB
75 70 65 60 55 50 10
100
1000 Hz
T-2212
Full space on axis SPL, 1/3 octave averaged Distance 4m, ‘cluster configuration’ at position 1
4
10000
100000
AXYS T-2212 data sheet rev 1.1 / GvB / Dec. 15th 1995
125 Hz
250 Hz
0 20
10
0 -10
-20
30
20 -30
40
10
-10
-20
30 -40
50
-30
40 -50 -60
60 70
-40
50
-50 -60
60
-70
70
-70
80
-80
80
90
-90
90
-90
100
-100
100
-100
110
-110
120
-80
110
-120 -130
130 140 150
160
170
-170
-160
-110
120
-120 -130
130
-140 -150
140 150
160
170 180
500 Hz
1 kHz
0 20
-170
180
10
-160
-140 -150
0 -10
-20
30
20 -30 -40
40
10
-10
-20
30
50
-30 -40
40 -50
60
50
-60
70
-50
60
-70
-60
70
-70
80
-80
80
90
-90
90
-90
100
-100
100
-100
-110
110 120
120
-130
140 150
160
170
-170
-160
-110
110
-120
130
-80
-120
130
-140 -150
-130
140 150
160
170 180
2 kHz
4 kHz
0 20
-170
180
0 -10
10
-160
-140 -150
-20
20 -30
30 40
-10
10
-20 -30
30 -40
50
40 -50 -60
60 70
-40
50
-50 -60
60
-70
70
-70
80
-80
80
90
-90
90
-90
100
-100
100
-100
-110
110 120
120
-130
140 150
160
170
-170
-160
-110
110
-120
130
-80
-120
130
-140 -150
-130
140 150
160
170 180
8 kHz
16 kHz
0 20
-170
180
0 -10
10
-160
-140 -150
-20
30
20 -30
40
-40
50
-10
10
-20
30
-30
40 -50
60
-60
-50
60
-70
70
-40
50
-60 -70
70
80
-80
80
90
-90
90
-90
100
-100
100
-100
110
-110 -120
120 130
110
150
160
170
-170
-160
130
-140 -150
-130
140 150
180
T-2212
-110 -120
120
-130
140
-80
160
170
-170
-160
-140 -150
180
Horizontal polar data 1/1 octave averaged Angular resolution 10 deg, scale 6 dB/div, positive angles = right side
5
AXYS T-2212 data sheet rev 1.1 / GvB / Dec. 15th 1995
125 Hz
250 Hz
0 20
10
0 -10
-20
30
20 -30
40
10
-10
-20
30 -40
50
-30
40 -50 -60
60 70
-40
50
-50 -60
60
-70
70
-70
80
-80
80
90
-90
90
-90
100
-100
100
-100
110
-110
120
-80
110
-120 -130
130 140 150
160
170
-170
-160
-110
120
-120 -130
130
-140 -150
140 150
160
170 180
500 Hz
1 kHz
0 20
-170
180
10
-160
-140 -150
0 -10
-20
30
20 -30 -40
40
10
-10
-20
30
50
-30 -40
40 -50
60
50
-60
70
-50
60
-70
-60
70
-70
80
-80
80
90
-90
90
-90
100
-100
100
-100
-110
110 120
120
-130
140 150
160
170
-170
-160
-110
110
-120
130
-80
-120
130
-140 -150
-130
140 150
160
170 180
2 kHz
4 kHz
0 20
-170
180
0 -10
10
-160
-140 -150
-20
20 -30
30 40
-10
10
-20 -30
30 -40
50
40 -50 -60
60 70
-40
50
-50 -60
60
-70
70
-70
80
-80
80
90
-90
90
-90
100
-100
100
-100
-110
110 120
120
-130
140 150
160
170
-170
-160
-110
110
-120
130
-80
-120
130
-140 -150
-130
140 150
160
170 180
8 kHz
16 kHz
0 20
-170
180
0 -10
10
-160
-140 -150
-20
30
20 -30
40
-40
50
-10
10
-20
30
-30
40 -50
60
-60
-50
60
-70
70
-40
50
-60 -70
70
80
-80
80
90
-90
90
-90
100
-100
100
-100
110
-110 -120
120 130
110
150
160
170
-170
-160
-110 -120
120
-130
140
-80
130
-140 -150
-130
140 150
160
170
180
T-2212
-170
-160
-140 -150
180
Vertical polar data 1/1 octave averaged Angular resolution 10 deg, scale 6 dB/div, positive angles = top side
6
AXYS T-2212 data sheet rev 1.1 / GvB / Dec. 15th 1995
T-2212 horizontal isobaric curves -90 -80 -70 -60 -50 -40 -30 -20 -10 0 deg 10 20 30 40 50 60 70 80
127
225
399
707
1253
2219
3932
6965
12340
90 21860
Hz
T-2212 vertical isobaric curves -90 -80 -70 -60 -50 -40 -30 -20 -10 0 deg 10 20 30 40 50 60 70 80
127
225
399
707
1253
2219
3932
6965
12340
90 21860
Hz
T-2212
Isobaric curves 1/1 octave averaged -6, -12 and -18 dB
7
AXYS T-2212 data sheet rev 1.1 / GvB / Dec. 15th 1995
T -2212 horiz ontal 3-D graph
127 169 225 300 399 531 707 941 1253 1667 Hz 2219 2954 3932 5233 6965 9271 12340 16424 21861
0
-6
-12 dB -18
-24
-30 90 60 30
T-2212
0 -30 -60 -90 deg
Horizontal 3-D graph 1/6 octave averaged
8
AXYS T-2212 data sheet rev 1.1 / GvB / Dec. 15th 1995
T -2212 vertical 3-D graph
127 169 225 300 399 531 707 941 1253 1667 Hz 2219 2954 3932 5233 6965 9271 12340 16424 21861
0
-6
-12 dB -18
-24
-30 90 60 30
T-2212
0 -30 -60 -90 deg
Vertical 3-D graph 1/6 octave averaged
9