T-2212 - Edelmat

Dec 15, 1995 - transducers to a safe value, DC protection on each of the amplifier ... side shall display the status of all protection circuits. ... Cross-over - Type.
477KB taille 1 téléchargements 132 vues
AXYS T-2212 data sheet rev 1.1 / GvB / Dec. 15th 1995

T-2212 Architectural and engineering specifications The loudspeaker unit shall be of the two-way active type with integrated electronics, two 12” low/mid speakers and one 2” ferrofluid cooled driver with carbon-fiber diaphragm. Specially developed horns made of fiberglass reinforced epoxy and coated in order to dampen resonance’s shall be mounted on each transducer. The horns shall have an exponential area increase and a constant directivity over a wide frequency range. Arrayability shall be guaranteed by a well defined frequency independent horizontal opening angle in exact correspondence with the shape of the cabinet. The complete electronics shall be mounted on a chassis which is placed in a separated part at the backside of the enclosure. Electronics shall consist of active filters to implement crossovers and equalization, protection circuitry and three power amplifiers coupled to two independent power supplies. The filter section shall include a ‘cluster configuration’ switch which enables the user to compensate for coupling effects in the low-mid frequency range when using multiple unit clusters. Protection shall consist of two Dynamic Level Control (DLC) circuits that limit the dissipated mean power of the transducers to a safe value, DC protection on each of the amplifier outputs, high chassis temperature and high voltage on the mains supply. A LED on the front and rear side shall display the status of all protection circuits. The balanced signal input connector shall be a 3p female XLR type (p2 = +, p3 = -, p1 = gnd), the full-range signal output link connector shall be a 3p male XLR type (p2 = +, p3 and p1 = gnd). A hard-wired bypass relay guarantees the signal transfer to the link output in any condition. A mains voltage switch (115/230 V) shall be implemented on the outside of the unit and the mains connector shall be a male DO-3 type. All connectors shall be grouped together at the lower side of the chassis. The enclosure shall be constructed of laminated birch plywood reinforced with bracing and two internal aluminum frames to which eight rigging frame attachment tracks are connected (four on top and four on the bottom). It shall contain six recessed handles and shall be trapezoidal shaped to facilitate the construction of clusters. A passive convection system shall ensure an efficient transfer of the heat generated by the transducers and the electronics. The front of the enclosure shall be covered with open cell foam mounted on a protective perforated steel grill. The enclosure shall be finished with a polyurethane coating. The complete loudspeaker unit shall meet the following performance criteria: Frequency range of 130 - 18k Hz on axis (+/- 3 dB), max. SPL at 1m of 136 dBSPL continuous and 139 dBSPL peak, - 6 dB coverage angle of 35o horizontal by 32o vertical averaged 1k to 15k Hz. Dimensions are 56.7” (1440 mm) H x 21.3” (540 mm) W x 26.4” (670 mm) D, trapezoidal shaped. Weight 203 lbs. (92 kg). The loudspeaker unit shall be the AXYS model T-2212.

1

AXYS T-2212 data sheet rev 1.1 / GvB / Dec. 15th 1995

Specifications1 2

Acoustical : Frequency range Max SPL (1m)

3

Coverage angle

: 130 - 18k Hz (+/-3 dB) - Continuous - Peak

: 136 dB : 139 dB

4

o

o

: 35 H x 32 V

Self generated noise SPL (A-weighed, 1m)

: 34 dB

Electrical: Input

- Sensitivity (120 dBSPL/1m) - Impedance (balanced) - Connector (XLR female type)

: -15 dBu : 20k Ω : p2=+, p3=-, p1=gnd

Link

- Impedance - Connector (XLR male type)

: 300 ### : p2=+, p3 and p1=gnd

Cross-over

- Type - Frequency (-6 dB) - Control switch

: 24 dB/Oct HF, 18 dB/Oct MF : 80 Hz LF-MF, 1k7 Hz MF-HF : 3 step ‘cluster configuration’

3

Power amplifiers

: 3 x 220 Wrms (8 ###)

Protection

: multi band o : Theatsink> 80 C : over / under voltage

Mains

- DLC - Thermal - Mains voltage guard - DC per amplifier - Hard-wired bypass 5

- Voltage (+5/-10 %) - Connector type - Fuses (slow type) - Power consumption

: on link output : 115/230 V switchable : DO-3 male : 2 x 6.3 A and 2 x 100 mA : 40 Widle / 600 Wfull load

General: o

Temperature range (ambient)

: 0 - 40 C

Transducers

: 2 x 12” / 1 x 2” all horn loaded

Dimensions (H x W x D)

: 1440 x 540 x 670 mm

Weight

: 92 kg

Notes: 1 Specifications are valid for 1 unit with ‘cluster configuration’ switch at position 1. 2 Measured under anechoic ‘full-space’ conditions unless stated otherwise. 3 Measured with gated sine waves. 4 -6 dB, average value 1k - 15k Hz. 5 Other voltages available upon request

2

AXYS T-2212 data sheet rev 1.1 / GvB / Dec. 15th 1995

Acoustical data table

Frequency1 (Hz)

125 250 500 1k 2k 4k 8k

DI2 (dB)

Hor. coverage - 6 dB (deg) 3.6 6.1 10.3 14.6 14.1 15.9 16.8

220 180 105 60 53 41 35

Vert. coverage - 6 dB (deg) 165 115 55 32 27 44 37

1. All frequencies octave band centered, all values measured with ‘cluster configuration’ switch at position 1. 2. Directivity Index calculated from horizontal and vertical polar data. 3. Peak values measured with gated sine waves under anechoic conditions, scaled to 1m ETC time zero.

Directivity Index

T -2212 D irectivity Index 20 15 dB 10 5 0 100

1000

10000

Hz

3

Max. SPL at 1m3 (dBSPL) 128 135 137 139 138 135 129

AXYS T-2212 data sheet rev 1.1 / GvB / Dec. 15th 1995

SPL response

T -2212 100 95 90 85 80 dB

75 70 65 60 55 50 10

100

1000 Hz

T-2212

Full space on axis SPL, 1/3 octave averaged Distance 4m, ‘cluster configuration’ at position 1

4

10000

100000

AXYS T-2212 data sheet rev 1.1 / GvB / Dec. 15th 1995

125 Hz

250 Hz

0 20

10

0 -10

-20

30

20 -30

40

10

-10

-20

30 -40

50

-30

40 -50 -60

60 70

-40

50

-50 -60

60

-70

70

-70

80

-80

80

90

-90

90

-90

100

-100

100

-100

110

-110

120

-80

110

-120 -130

130 140 150

160

170

-170

-160

-110

120

-120 -130

130

-140 -150

140 150

160

170 180

500 Hz

1 kHz

0 20

-170

180

10

-160

-140 -150

0 -10

-20

30

20 -30 -40

40

10

-10

-20

30

50

-30 -40

40 -50

60

50

-60

70

-50

60

-70

-60

70

-70

80

-80

80

90

-90

90

-90

100

-100

100

-100

-110

110 120

120

-130

140 150

160

170

-170

-160

-110

110

-120

130

-80

-120

130

-140 -150

-130

140 150

160

170 180

2 kHz

4 kHz

0 20

-170

180

0 -10

10

-160

-140 -150

-20

20 -30

30 40

-10

10

-20 -30

30 -40

50

40 -50 -60

60 70

-40

50

-50 -60

60

-70

70

-70

80

-80

80

90

-90

90

-90

100

-100

100

-100

-110

110 120

120

-130

140 150

160

170

-170

-160

-110

110

-120

130

-80

-120

130

-140 -150

-130

140 150

160

170 180

8 kHz

16 kHz

0 20

-170

180

0 -10

10

-160

-140 -150

-20

30

20 -30

40

-40

50

-10

10

-20

30

-30

40 -50

60

-60

-50

60

-70

70

-40

50

-60 -70

70

80

-80

80

90

-90

90

-90

100

-100

100

-100

110

-110 -120

120 130

110

150

160

170

-170

-160

130

-140 -150

-130

140 150

180

T-2212

-110 -120

120

-130

140

-80

160

170

-170

-160

-140 -150

180

Horizontal polar data 1/1 octave averaged Angular resolution 10 deg, scale 6 dB/div, positive angles = right side

5

AXYS T-2212 data sheet rev 1.1 / GvB / Dec. 15th 1995

125 Hz

250 Hz

0 20

10

0 -10

-20

30

20 -30

40

10

-10

-20

30 -40

50

-30

40 -50 -60

60 70

-40

50

-50 -60

60

-70

70

-70

80

-80

80

90

-90

90

-90

100

-100

100

-100

110

-110

120

-80

110

-120 -130

130 140 150

160

170

-170

-160

-110

120

-120 -130

130

-140 -150

140 150

160

170 180

500 Hz

1 kHz

0 20

-170

180

10

-160

-140 -150

0 -10

-20

30

20 -30 -40

40

10

-10

-20

30

50

-30 -40

40 -50

60

50

-60

70

-50

60

-70

-60

70

-70

80

-80

80

90

-90

90

-90

100

-100

100

-100

-110

110 120

120

-130

140 150

160

170

-170

-160

-110

110

-120

130

-80

-120

130

-140 -150

-130

140 150

160

170 180

2 kHz

4 kHz

0 20

-170

180

0 -10

10

-160

-140 -150

-20

20 -30

30 40

-10

10

-20 -30

30 -40

50

40 -50 -60

60 70

-40

50

-50 -60

60

-70

70

-70

80

-80

80

90

-90

90

-90

100

-100

100

-100

-110

110 120

120

-130

140 150

160

170

-170

-160

-110

110

-120

130

-80

-120

130

-140 -150

-130

140 150

160

170 180

8 kHz

16 kHz

0 20

-170

180

0 -10

10

-160

-140 -150

-20

30

20 -30

40

-40

50

-10

10

-20

30

-30

40 -50

60

-60

-50

60

-70

70

-40

50

-60 -70

70

80

-80

80

90

-90

90

-90

100

-100

100

-100

110

-110 -120

120 130

110

150

160

170

-170

-160

-110 -120

120

-130

140

-80

130

-140 -150

-130

140 150

160

170

180

T-2212

-170

-160

-140 -150

180

Vertical polar data 1/1 octave averaged Angular resolution 10 deg, scale 6 dB/div, positive angles = top side

6

AXYS T-2212 data sheet rev 1.1 / GvB / Dec. 15th 1995

T-2212 horizontal isobaric curves -90 -80 -70 -60 -50 -40 -30 -20 -10 0 deg 10 20 30 40 50 60 70 80

127

225

399

707

1253

2219

3932

6965

12340

90 21860

Hz

T-2212 vertical isobaric curves -90 -80 -70 -60 -50 -40 -30 -20 -10 0 deg 10 20 30 40 50 60 70 80

127

225

399

707

1253

2219

3932

6965

12340

90 21860

Hz

T-2212

Isobaric curves 1/1 octave averaged -6, -12 and -18 dB

7

AXYS T-2212 data sheet rev 1.1 / GvB / Dec. 15th 1995

T -2212 horiz ontal 3-D graph

127 169 225 300 399 531 707 941 1253 1667 Hz 2219 2954 3932 5233 6965 9271 12340 16424 21861

0

-6

-12 dB -18

-24

-30 90 60 30

T-2212

0 -30 -60 -90 deg

Horizontal 3-D graph 1/6 octave averaged

8

AXYS T-2212 data sheet rev 1.1 / GvB / Dec. 15th 1995

T -2212 vertical 3-D graph

127 169 225 300 399 531 707 941 1253 1667 Hz 2219 2954 3932 5233 6965 9271 12340 16424 21861

0

-6

-12 dB -18

-24

-30 90 60 30

T-2212

0 -30 -60 -90 deg

Vertical 3-D graph 1/6 octave averaged

9