strobe damage stopper

Mark and drill (4) holes 1/4 in. (6.3mm) diameter, 1 1/4 in. (32mm) deep. 4. Insert the (4) ... ADTG1-V SERIES. 40%. 34%. HONEYWELL. XLS202 SERIES. 40%.
458KB taille 1 téléchargements 59 vues
MOUNTING HARDWARE

WHERE FREQUENT WASH DOWNS OCCUR SUPPLIED WITH SUB-122 ENVIRO KIT 06297T EXTERNAL MOUNTING TABS — INSERT TABS INTO FRAME SLOTS AS SHOWN

Safety Technology International, Inc. 2306 Airport Road • Waterford, Michigan 48327-1209 Phone: 248-673-9898 • Fax: 248-673-1246 Toll Free: 800-888-4784 • E-mail: [email protected] Web: www.sti-usa.com OPTIONAL CONDUIT HUB SUB-6297B20 (ACCEPTS 3/4 in. RIGID CONDUIT FITTINGS) 19033 ANCHOR INCLUDES GASKET AND (4) PROVIDED MOUNTING HARDWARE

Safety Technology International (Europe) Ltd.

Unit 49G Pipers Road • Park Farm Industrial Estate • Redditch Worcestershire • B98 0HU • England • Tel: 44 (0) 1527 520 999 19013 SCREW #10 x 1 1/2 in. Fax: 44 (0) 1527 501 999 • Freephone: 0800 085 1678 (UK only) (4) PROVIDED E-mail: [email protected] • Web: www.sti-europe.com

BACK OF FRAME ASSY. MAY BE DRILLED TO ALLOW WIRE ACCESS AS SHOWN

IF ADDED PROTECTION IS NEEDED DUE TO ENVIROMENTAL CONDITIONS ORDER SUB-122 ENVIRO KIT

TYPICAL NOTIFICATION APPLIANCE 629763 STANDOFF BLOCKS (4) MUST BE USED IN AREAS WHERE FREQUENT WASH DOWNS OCCUR SUPPLIED WITH SUB-122 ENVIRO KIT

6

19013 SCREW #10 x 1 1/2 in. (4) PROVIDED 01210 COVER ONLY BACK OF FRAME ASSY. MAY BE DRILLED TO ALLOW WIRE ACCESS AS SHOWN

LOCATED IN THIS AREA DRILL A 1/4 in.(6.3mm) DIA. HOLE

1. To minimize strobe light loss, regardless of the type of horn/strobe appliance used, the clear section (NOT the section containing the cutout slots), must be centered over the strobe light lens. Failure to follow these instructions may lead to light loss transmission. 2. Damage Stopper must be installed to comply with applicable NEC, NFPA and local codes. 1 in.(25mm) 3. In areas where frequent wash downs occur, standoff blocks must be used. 4. In applications where wash downs, rainfall or condensation occur, it is recommended APPROX that a drain or weep hole be provided. Refer to weep hole installation diagram. CENTER LINE 5. OF Damage Stopper may be installed outdoors when appliance carries an outdoor rating. UNDERSIDE OF LOCATED IN THIS AREA

!

INSTALL CLAMP IN NOTCH 2 AS SHOWN

IF ADDED PROTECTION IS 01210 COUVERCLE SEULEMENT NEEDED DUE TO ENVIROMENTAL CONDITIONS ORDER SUB-122 ENVIRO KIT

TYPICAL NOTIFICATION APPLIANCE

HEIGHT 8.5 in.(216mm)

19047 #8-32 x 3/8 in. SOCKET HEAD CAP SCREW (4) PROVIDED

19033 AN (4) PRO DEPTH 3.5 in.(89mm)

CLEAR SECTION

06297B FRAME ASSY.

INSTALLATION NOTES

COVER

629764 CLAMP (4) PROVIDED

OPTIONAL COND SUB(ACCEPTS 3/4 CONDUIT F INCLUDES GAS MOUNTING HA

2

06297T EXTERNAL MOUNTING TABS — CLEAR INSERT TABS INTO FRAME SECTION SLOTS AS SHOWN

06297B FRAME ASSY.

19033 ANCHOR (4) PROVIDED

1

01210 COVER ONLY

WIDTH 6.5 in.(165mm)

!

01210 COUVERCLE SEULEMENT 06297A BACKBOX 06297T MOUNTING TABS (4) PROVIDED

629764 CLAMP (4) PROVIDED

DRILL FOR CONDUIT ENTRY 3 3/8 in. (86mm)

19047 #8-32 x 3/8 in. SOCKET HEAD CAP SCREW (4) PROVIDED

3/4 in.(44mm) HEIGHT 8.5 in.(216mm) PRODUCT DIMENSIONS INTERNAL DIMENSIONS

REMARQUES SUR DRILLL’INSTALLATION A 1/4 in.(6.3mm) DIA. HOLE

1. Afin de minimiser la perte de lumière stroboscopique, quel que soit le type d’alarme sonore/de stroboscope utilisé, la section dégagée (et NON la section contenant les fentes de découpe), doit être centrée sur l’objectif stroboscopique. Le fait d’omettre ces instructions risque d’entraîner la perte de diffusion de la lumière. 2. Le Stopper de dégâts doit être installé de sorte à être conforme avec les normes NEC, NFPA applicables et les codes locaux. 3. Dans les zones où des jets d’eau fréquents surviennent, des blocs de détection à distance doivent être utilisés. 4. Dans les applications où des jets d’eau, des précipitations ou de la condensation se produisent, il est recommandé de prévoir un trou de vidange ou une barbacane. Reportez-vous à schéma d’installation d’une barbacane. 5. Il est possible d’installer un Stopper de dégâts à l’extérieur lorsque l’appareil est homologué pour utilisation à l’extérieur. 1 in.(25mm)

INSTALLATION INSTRUCTIONS - REFER TO EXPLODED VIEW 1. 2. 3. 4. 5. 6. 7. 8. 9.

Insert the (4) 06297T external mounting tabs into the frame assembly slots. APPROX Using backLINE box assembly as a template, place against mounting surface at proper location according to NFPA 72. CENTER Mark drill (4) OF and UNDERSIDE OFholes 1/4 in. (6.3mm) diameter, 1 1/4 in. (32mm) deep. COVER Insert the (4) anchors into the wall. Mount back box to wall with screws. Install electrical fittings as needed. Install horn/strobe appliance. Install cover with clips and screws. Test appliance according to appliance manufacturer’s instructions.

LOCATED IN THIS AREA DEPTH DRILL A 1/4 in.(6.3mm) DIA. HOLE 3.5 in.(89mm)

629763 STANDOFF BLOCKS (4) PROVIDED

19033 ANCHOR (4) PROVIDED

CLEANING INSTRUCTIONS

WIDTH 6.5 in.(165mm)

19013 SCREW #10 x 1 1/2 in. (4) PROVIDED

Rinse with water to remove abrasive dust and dirt. Wash with 629764 RETAINING CLIPS soap or mild detergent, using a soft cloth (do not scrub). Rinse (4) PROVIDED once more then dry with a soft cloth or chamois. To remove 19047with #8-32 x 3/8 in. SOCKET grease or wet paint, rub gently with a cloth wetted naphtha. Then wash and rinse. DO NOT USE RAZOR BLADES.HEAD (DOCAP SCREWS (4) PROVIDED NOT USE RAZOR BLADES.)

629762 DRAIN SCREEN

WEEP HOLE INSTALLATION

Electronic warranty form at www.sti-usa.com/wc14

INSTALLATION OF STI-1210B SPEAKER HORN/STROBE DAMAGE STOPPER® A 1-1/16 in. DIAMETER CONDUIT

1-3/4

1 in.(25mm)

APPROX PRODUCT DIMENSIONS CENTER LINE OF UNDERSIDE OF COVER

629761 NEOPRENE GASKET

All specifications and information shown were current as of publication and are subject without notice. ENTRY HOLE MUSTto BE change FIELD INSTALLED

CLEAR SECTION

A 1-1/16 in. 1210BIS APRIL2006 DIAMETER CONDUIT ENTRY HOLE MUST BE FIELD INSTALLED

!

0121

0121

UL INSTALLATION REQUIREMENTS STI-1210 / STI-1221 SERIES CAUTION

Attention

• This enclosure is rated to protect signaling appliances indoors and in areas of indirect weather exposure. The cover may be used outdoors only with devices also suitable for outdoor use. • When covering fire-signaling appliances with this enclosure, some light and sound loss occurs. Please follow these guidelines listed during installation. • Voice speaker appliance: No spacing adjustment is required for 0.5W, 1.0W and 2.0W appliances. • Refer to the appliance manufacturer's candela rating. Multiply this number by the light loss value from the chart below to determine the new candela rating. Use this number and refer to the notification layout table of NFPA 72 for proper device locations. • The use of this cover on audible devices decreases the sound output by 6dB(A). Actual sound level output should be checked after installation to determine if adequate sound levels exist. Refer to the notification layout table of NFPA 72 for proper device locations.

• Ce boîtier est homologué pour protéger les appareils de signalisation d’incendie à l’intérieur et dans les zones d’exposition indirecte aux intempéries. Le couvercle ne peut être utilisé à l’extérieur qu’avec les appareils appropriés pour une utilisation à l’extérieur aussi. • Le fait de couvrir les appareils de signalisation d’incendie au moyen de ce boîtier risque d’entraîner une certaine perte lumineuse et sonore. Veuillez vous conformer à ces directives lors de l’installation. • Haut-parleur: Aucun ajustement de distance n’est nécessaire pour les appareils à tension de 0,5 W, 1,0 W et 2,0 W. • Reportez-vous à la cote candéla du fabricant de l’appareil. Multipliez cette valeur par la valeur de la perte de lumière du tableau ci-dessous pour déterminer la nouvelle cote candéla. Utilisez cette nouvelle valeur et reportez-vous au tableau de disposition des alertes de la norme NFPA 72 pour les emplacements appropriés de l’appareil. • L’utilisation de ce couvercle sur les dispositifs sonores diminue la puissance sonore de 6 dB(A). Le niveau réel de la sortie sonore doit être vérifié après l’installation pour déterminer le maintien de niveaux sonores adéquats. Reportez-vous au tableau de disposition des alertes de la norme NFPA 72 pour les emplacements appropriés de l’appareil.

Performance Review - LIGHT DERATING FACTOR MANUFACTURER ADT SECURITY AMSECO

SERIES

STI-1210

STI-1221/1221A4X

MANUFACTURER

ADTG1-V SERIES

40%

34%

HONEYWELL

SERIES

STI-1210

STI-1221/1221A4X

XLS202 SERIES

40%

34%

SL24W-153075

22%

37%

HONEYWELL

XLSG1-HV SERIES

40%

34%

AMSECO – COLORED LENSES

SL24W-153075 A, B, G, OR R

47%

26%

HONEYWELL

XLSG1-HOV SERIES

40%

34%

AMSECO – COLORED LENSES

SL24C-3075110 A, B, G, OR R

47%

26%

MIRCOM

FS-240

47%

26%

AMSECO – COLORED LENSES

CSL24W-A, B, G, OR R

47%

26%

MIRCOM

MS SERIES

43%

45%

AMSECO – COLORED LENSES

CSL24C-A, B, G, OR R

47%

26%

MIRCOM

MG1-V SERIES

40%

34%

GES24 SERIES

-

31%

MIRCOM

MG1-HV SERIES

40%

34%

DETECTION SYSTEMS DETECTION SYSTEMS

GES24-15/75

-

-

MIRCOM

MG1-HOV SERIES

40%

34%

EST / EDWARDS

2440S SERIES

43%

45%

MIRTONE

MG1-V SERIES

43%

45% 31%

EST / EDWARDS

202 SERIES

43%

45%

NATIONAL TIME & SIGNAL

GES24 SERIES

-

EST / EDWARDS

G1-V SERIES

40%

34%

NATIONAL TIME & SIGNAL

GES24-15/75

-

-

EST / EDWARDS

G1-HV SERIES

40%

34%

POTTER ELECTRIC

AS-24-153075R

47%

26%

EST / EDWARDS

G1-HOV SERIES

40%

34%

POTTER ELECTRIC

AS-24-153075W

47%

26%

EST / EDWARDS

EG1-V SERIES

40%

34%

SECUTRON

GES24 SERIES

-

31%

EST / EDWARDS

EG1-HV SERIES

40%

34%

SECUTRON

GES24-15/75

-

-

EST / EDWARDS

EG1-HOV SERIES

40%

34%

SIEMENS

202- SERIES

43%

45% 34%

FARADAY LLC

2700

-

57%

SIEMENS

G1-V SERIES

40%

GENTEX

GES24 SERIES

-

31%

SIEMENS

U-MCS SERIES

-

-

GENTEX

GES24-15/75

-

-

SYSTEM SENSOR

SS24110ADA

46%

37%

SYSTEM SENSOR

61%

HARRINGTON SIGNAL

GES24 SERIES

-

31%

HARRINGTON SIGNAL

GES24-15/75

-

-

XLSG1-V SERIES

43%

45%

HONEYWELL

P2, PC2, P4, PC4, SX, SC

53%

WHEELOCK

RSS-24MCW

-

-

ZITON PTY LTD

ZG1-V SERIES

40%

34%

STI-1210 Series Sound Derating Factor: System Sensor P2, PC2, P4, PC4, SX, SC series models: 6.7 dBA, General: 6 dBA STI Generic Light Loss Value: STI-1210 Series: 53%; STI-1221 Series: 61% SAFETY TECHNOLOGY INTERNATIONAL, INC. • 2306 AIRPORT ROAD • WATERFORD • MICHIGAN 48327-1209 • PHONE: 248-673-9898 • FAX: 248-673-1246 • www.sti-usa.com