SL AUTO - icf-elbeuf.com

(CONTOL OF THE INDICATOR LIGHTS AND THE BUTTONS). REF:10530/C. PAGE 8. PAGE 1. THIS PROGRAMME COMPRISES TWO PHASES . SL AUTO.
121KB taille 2 téléchargements 311 vues
PAGE 8

PAGE 1

BREAKDOWN GUIDE MAIN DRAWING

CONDENSER DRIER

SL AUTO

ELECTRONIC POWER CARD M/AT

PH

BL/VI AP

N

BL/OR

DOOR FUSE

REF:10530/C

TC2 OR

THIS DRIER WITH ELECTRONIC PROGRAMMING COMES WITH A DIAGNOSTICS PROGRAMME TO ASSIST YOU IN FINDING THE CAUSE OF THE BREAKDOWN TC4

PRES.COND

VIOL

FULL TANK

TC5

IMPORTANT

CON.6V

TC6 CON.6V

ELECTRONIC POWER CARD

VIOL

BE/CL

R2:150_

BEFORE YOU ACTIVATE THIS PROGRAMME,ENSURE THAT: J2

MA/NR

CON.2V

1200W

THERMAL FUSE

-THE DRUM IS EMPTY OF WASHING -THE FILTER IS CLEAN(NO FLUFF) WARNING:DO NOT USE RUNNING WATER ON THE FILTER

VE/F

1000W

R1:140_

-THE CONDENSER IS CLEAN

CON.4V

BE/F KL1

MAR

BASKET MOTOR

WARNING

CD

NOIR

VE/CL

THIS PROGRAMME COMPRISES TWO PHASES

CON.3V FAN MOTOR

.

CD

PHASE 1

ROUG

(PAGES 2/3)THIS PROVIDES CONTROL OF THE PROGRAMME CARD'S FUNCTIONS (CONTOL OF THE INDICATOR LIGHTS AND THE BUTTONS) STEPS B-C-D-E ARE INDEPENDENT OF EACH OTHER AND CAN BE CARRIED OUT IN ANY ORDER STEP FENABLES YOU TO CHECK THAT ALL THE STEPS HAVE BEEN CARRIED OUT

HYGROCAPT VALVE SENSOR

ROUG

POSITIONED STOP

GR

PHASE 2 CON.2V

GR

J6 CON.4V

CON.4V

HYGROCAPT SENSOR

(PAGE 4/5)-THIS PROVIDES CONTROL OF THE COMPONENT'S FUNTIONS: DOOR MINISWITCH HYGROCAPT SENSOR MOTOR TRAVELLING IN THE + DIRECTION AND HEATING FAN FULL HEATING AND MOTOR TRAVELLING IN THE - DIRECTION HYGROCAPT SENSOR VALVE CONTROL POSITIONED STOP

PAGE 2

LEGEND:

PHASE 1

PAGE 3

PHASE 1

LIGHT LIT LIGHT UNLIT

PROGRAMME CARD CONTROL

LIGHT FLASHING

MANUAL CONTROL OF THE INDICATOR LIGHTS AND BUTTONS

INDICATE LIGHTS TO BE CHECKED

INITIATION OF SELF-TESTING

MANUAL OPERATIONS

CARD DISPLAY

DIAGNOSTICS

DRIER FUNCTIONS

IF THE DISPLAY FLASHES = OK

PRESS THE START/STOP BUTTON PRESS THE BUTTON

A

1

AND SUCCESSIVELY

1

2

3

PRESS THE BUTTON

IF THE DISPLAY IS FAULTY,CHECK:

YOU ARE NOW IN THE

2 THE DISPLAY FLASHES

3

AUDIBLE SIGNAL(3 BEEPS)

CONTROL PROGRAMME

-START/STOP -THE CONNECTION BETWEEN THE POWER

THE DRUM TURNS IN THE + DIRECTION

(IN LESS THAN 5 SECONDS)

4

-THE (MAINS)POWER SUPPLY

CARD AND THE PROGRAMME CARD OTHERWISE CHANGE THE POWER CARD

LIGHT L1-L2-L3-L4 ILLUMINATE IF THE INDICATED LIGHTS ILLUMINATE= OK

B

4

PRESS BUTTON

(THE DRUM TURNS IN THE + DIRECTION)

IF THE INDICATED LIGHTS ILLUMINATE= OK

LIGHT L5-L6 ILLUMINATE

C

PRESS BUTTON

5

5

OTHERWISE CHANGE THE POWER CARD

(THE DRUM TURNS IN THE + DIRECTION)

OTHERWISE CHANGE THE POWER CARD

IF THE INDICATED LIGHTS ILLUMINATE= OK

LIGHT L7 ILLUMINATE

PRESS BUTTON.

D

6 (THE DRUM TURNS IN THE + DIRECTION)

OTHERWISE CHANGE THE POWER CARD

6 LIGHT L8-L9 ILLUMINATE

PRESS BUTTON.

E

2

IF THE INDICATED LIGHTS ILLUMINATE= OK

(THE DRUM TURNS IN THE + DIRECTION)

OTHERWISE CHANGE THE POWER CARD

2

LIGHT L10-L11 AND THE DISPLAY ILLUMINATE

PRESS BUTTON.

F

7

IF THE INDICATED LIGHTS AND DISPLAY = OK

(THE DRUM TURNS IN THE + DIRECTION)

OTHERWISE CHANGE THE POWER CARD

7 LIGHT L12-L13 ILLUMINATE

PRESS BUTTON.

G

3

IF THE INDICATED LIGHTS ILLUMINATE= OK

(THE DRUM TURNS IN THE + DIRECTION)

3 PRESS BUTTON

3

(STEPS B-C-D-E HAVE ALL BEEN COMPLETED

THE DISPLAY FLASHES AND LIGHT L10 IS PERMANENTLY LIT

OR

OR

H

(IF YOU WISH TO BYPASS STEPS B-C-D-E)

3

PRESS BUTTON (3 3TIMES IN LESS THAN . 5 SECONDS)

(THE DRUM TURNS IN THE + DIRECTION)

THE DISPLAY FLASHES

AND LIGHT L10 FLASHES

OTHERWISE CHANGE THE POWER CARD

PAGE 4

PHASE 2 MANUAL OPERATIONS

THE INDICATOR LIGHTS GO OUT

A

FUNCTIONS

CARD DISPLAY

A

G

PAGE 5

PHASE 2

OPEN THE LID

MOTOR TRAVELLING IN THE

DIAGNOSTICS

DOOR MINISWITCH

+DIRECTION STOPS

IF THE DISPLAY SHOWS'11'=SENSOR OK

B

IF THE DISPLAY SHOWS '00'ou'10'ou '01'CHECK: 4V/4VCONNECTION BETWEEN THE SENSOR AND THE POWER CARD

B

'11'SHOWN ON THE DISPLAY

CLOSE THE LID

HYGROCAPT SENSOR CHECK OTHERWISE CHANGE THE HYGROCAPT SENSOR

H THE DIAGNOSTICS PROGRAMME IS STOPPED WITH DISPLAY '2'

(MOTOR AND POWER ARE STOPPED) IF THERE IS A SENSOR FAULT IN PH 'H'

CHECK ON THE MOTOR TRAVELLING '2'SHOWN ON THE DISPLAY

I

PRESS BUTTON

IN THE + DIRECTION

3 CHECK ON 1200W POWER

3

IF THERE IS A MOTOR FAULT,CHECK: -THE CONNECTION BETWEEN THE MOTOR AND THE POWER CARD -THE CONDENSATOR THE MOTOR IF 1200W POWER FAULT CHECK: -THE CONNECTION BETWEEN THE HEATER AND THE POWER CARD -1/2" THERMOSTATS -HEATING ELEMENT(THERMAL FUSE) OTHERWISE CHANGE THE POWER CARD

IF THERE IS A FAN FAULT,CHECK: '3'SHOWN ON THE DISPLAY

J

PRESS BUTTON

CHECK ON THE FAN

3

-THE CONNECTION BETWEEN THE FAN AND THE POWER CARD -CONDENSATOR FAN MOTOR

3

OTHERWISE CHANGE THE POWER CARD

CHECK ON THE SENSOR VALVE COIL '14'SHOWN ON THE DISPLAY

K

THE DIAGNOSTICS PROGRAMME IS STOPPED

(MOTOR AND POWER ARE STOPPED)

CHECK ON THE MOTOR TRAVELLING IN THE - DIRECTION

PRESS BUTTON

IF THE DISPLAY SHOWS'14'=SENSOR OK IF THE DISPLAY SHOWS'04'CHECK

3 CHECK ON THE MAXIMUM HEATING

3

CHECK: -THE CONNECTION BETWEEN THE COIL AND THE POWER CARD OTHERWISE CHANGE THE HYGROCAPT SENSOR IF THERE IS A HEATING FAULT,CHECK: -THE CONNECTION BETWEEN THE HEATER AND THE POWER CARD -1/2"THERMOSTATS -HEATING ELEMENT (THERMAL FUSE) OTHERWISE CHANGE THE POWER CARD THE DIAGNOSTICS PROGRAMME IS STOPPED WITH DISPLAY '5'

(MOTOR IS STOPPED)

'5'SHOWN ON THE DISPLAY THEN

IF THERE IS A SENSOR FAULT IN PH 'K'

CHECK ON THE PHASE OF THE POSITIONED STOP

L

'AP'FLASHING PRESS BUTTON

3

THEN 'AP'PERMANENTLY LIT

3

(STOP WITH THE BASKET IN THE HIGH POSITION)

(NB:FOR SL MODELS NOT FITTED WITH THE OPTION

EXTINCTION DE TOUS LES VOYANTS PRESS THE START/STOP BUTTON

1

1

CHECK: -THE CONNECTION BETWEEN THE POSITIONED STOP

AND THE POWER CARD

-THE PRESENCE OF THE MAGNET -THE POSITIONED STOP SENSOR OTHERWISE CHANGE THE POWER CARD

THE DISPLAY SHOWN '5' FLASHING)

M

IF THERE IS A FAULT ON THE POSOTIONED STOP

EXIT FROM THE CONTROL PROGRAMME)

PAGE 6

PAGE 7

16

17 GR

J7

J8

VCC

HR

GND

CMT2

CMT1

COM

NC

LED3

LED1

LED2

J2

SCL

SDA

MUX

NC

NEUTR

J1

OPT2

OPT1

START

COM J3

J4

PROGRAMME CARD

COM

START/STOP

CARTE DE PUISSANCE

CTN J6 GR

COSSERET

SECT

WIRING DIAGRAM

BL/VI

BL/VI

SAV 57X1511

SL AUTO CD

VE/CL

ROUG

ROUG

MAR

NOIR

BE/F

BE/CL

VIOL

VIOL

OR

BL/OR

BL/VI

DOOR FUSE

VE/F

MA/NR

J14

GR

J6

GR

SCL

SDA

N

PH

POSITIONED STOP

VE/CL

ROUG

ROUG

MAR

NOIR

BE/F

BE/CL

VIOL

VIOL

OR

BL/OR

BL/VI

VE/F

N

BA

. PHASE

TERRE MAS.PLAQ.

NEUTRE

BLANC BLANC BLANC BLANC

ROUGE ROUGE VE/CL

MARRON

BE/F NOIR

VIOL

VIOL BE/CL

JAUNE

5 6 7 8 9

1200W

HEATING ELEMENT

BASE SOCKET

HYGROCAPT SENSOR

BLANC BLANC BLANC BLANC

ROUGE

ROUGE MARRON

VE/CL

NOIR

BLEU

MAR

NOIR

BLEU

COND.8UF

COND.1.5UF

BE/F

MARRON

NOIR

FAN

1000W

FULL TANK

FUS.

BASKET MOTOR

ROUGE

VIOL

VIOL

NOIR

BA NOIR MARRON

0R

JAUNE

R2

R1

PRESENCE COND.

BE/CL

VE/F.

(230V-50HZ)

THERMOSTAT

1 2 3

3

5 6 7

8 9

10

11 12

13

14

15

10

COMMON BASKET MOTOR

11

COMMON BASKET MOTOR IN THE + DIRECTION

12

COMMON BASKET MOTOR

NEUTRAL+DOOR FUSE

13

VALVE COIL CONTROL

DOOR FUSE

14

VALVE COIL CONTROL

TANK FUSE+PRESENCE OF CONDENSER

15

FAN MOTOR CONTROL

16

POSITIONED STOP SENSOR

17

POSITIONED STOP SENSOR

1200W HEATING ELEMENT CONTROL 1000W HEATING ELEMENT CONTROL LIVE

N

L

VE/F

FILTRE AP

BL/OR

L

THERMOSTAT

2

1

MA/NR

BL/OR

ORANGE

MA/NR

POWER CARD

TANK FUSE+PRESENCE OF CONDENSER

IN THE - DIRECTION

COMMON HEATING ELEMENT CHAUFFANT (1000+1200W)

WARNING WHEN REPLACING THE POWER CARD: -RESPECT THE CONFORMITY BETWEEN THE COLOR OF THE WINES IN THE STRAND AND THE MARKINGS ON THE CARD -PULL THE CONNECTORS TO DISENTANGLE THEM (DO NOT PULL THE WIRES)

MARQUAGE/CARTE WIRE COLOR MA/NR -BROWN/BLACK VE/F -DARK GREEN BL/VI -WHITE/VIOLET BL/OR -WHITE ORANGE OR -ORANGE VIOL -VIOLET BE/CL -LIGHT BLUE BE/F -DARK BLUE NOIR -BLACK MAR -BROWN ROUGE -RED VE/CL -LIGHT GREEN