Safety data sheet

Wash affected eyes for at least 15 minutes under running water with eyelids held open. .... The local regulations on waste-water treatment must be followed.
38KB taille 88 téléchargements 413 vues
Safety data sheet Page: 1/9 BASF Safety data sheet according to Regulation (EC) No. 1907/2006 Date / Revised: 07.12.2011 Version: 1.0 Product: Infineum V 350 (ID no. 30535415/SDS_GEN_EU/EN) Date of print 08.12.2011

1. Identification of the substance/mixture and of the company/undertaking Product identifier

Infineum V 350 Relevant identified uses of the substance or mixture and uses advised against Relevant identified uses: Component for lubricants and metal working fluids

Details of the supplier of the safety data sheet Company: BASF SE 67056 Ludwigshafen GERMANY Telephone: +49 621 60-0 E-mail address: [email protected]

Emergency telephone number International emergency number: Telephone: +49 180 2273-112

2. Hazards Identification Label elements According to Regulation (EC) No 1272/2008 [CLP] Globally Harmonized System, EU (GHS) The product does not require a hazard warning label in accordance with GHS criteria.

According to Directive 67/548/EEC or 1999/45/EC

Page: 2/9 BASF Safety data sheet according to Regulation (EC) No. 1907/2006 Date / Revised: 07.12.2011 Version: 1.0 Product: Infineum V 350 (ID no. 30535415/SDS_GEN_EU/EN) Date of print 08.12.2011 EEC Directives

The product does not require a hazard warning label in accordance with EC Directives.

Classification of the substance or mixture According to Regulation (EC) No 1272/2008 [CLP] No need for classification according to GHS criteria for this product.

Other hazards According to Regulation (EC) No 1272/2008 [CLP] Other Hazards (GHS): If applicable information is provided in this section on other hazards which do not result in classification but which may contribute to the overall hazards of the substance or mixture.

3. Composition/Information on Ingredients Mixtures Chemical nature Preparation based on: esters, hydrocarbons, additives

4. First-Aid Measures Description of first aid measures Remove contaminated clothing. If inhaled: If difficulties occur after vapour/aerosol has been inhaled, remove to fresh air and seek medical attention. On skin contact: Wash thoroughly with soap and water. On contact with eyes: Wash affected eyes for at least 15 minutes under running water with eyelids held open. On ingestion: Rinse mouth and then drink plenty of water.

Most important symptoms and effects, both acute and delayed Symptoms: The most important known symptoms and effects are described in the labelling (see section 2) and/or in section 11. Further important symptoms and effects are so far not known.

Page: 3/9 BASF Safety data sheet according to Regulation (EC) No. 1907/2006 Date / Revised: 07.12.2011 Version: 1.0 Product: Infineum V 350 (ID no. 30535415/SDS_GEN_EU/EN) Date of print 08.12.2011

Indication of any immediate medical attention and special treatment needed Treatment: Treat according to symptoms (decontamination, vital functions), no known specific antidote.

5. Fire-Fighting Measures Extinguishing media Suitable extinguishing media: water spray, dry powder, foam Unsuitable extinguishing media for safety reasons: water jet

Special hazards arising from the substance or mixture harmful vapours Evolution of fumes/fog. The substances/groups of substances mentioned can be released in case of fire.

Advice for fire-fighters Special protective equipment: Wear a self-contained breathing apparatus. Further information: The degree of risk is governed by the burning substance and the fire conditions. Contaminated extinguishing water must be disposed of in accordance with official regulations.

6. Accidental Release Measures Personal precautions, protective equipment and emergency procedures Use personal protective clothing. Breathing protection required.

Environmental precautions Contain contaminated water/firefighting water. Do not discharge into drains/surface waters/groundwater.

Methods and material for containment and cleaning up For large amounts: Pump off product. For residues: Pick up with suitable absorbent material. Dispose of absorbed material in accordance with regulations.

Reference to other sections Information regarding exposure controls/personal protection and disposal considerations can be found in section 8 and 13.

7. Handling and Storage Precautions for safe handling No special measures necessary provided product is used correctly. Protection against fire and explosion: Take precautionary measures against static discharges.

Page: 4/9 BASF Safety data sheet according to Regulation (EC) No. 1907/2006 Date / Revised: 07.12.2011 Version: 1.0 Product: Infineum V 350 (ID no. 30535415/SDS_GEN_EU/EN) Date of print 08.12.2011

Conditions for safe storage, including any incompatibilities Suitable materials for containers: High density polyethylene (HDPE), Low density polyethylene (LDPE), Steel container, Stainless steel, carbon steel (iron) Further information on storage conditions: Keep container tightly closed and dry; store in a cool place.

Specific end use(s) For the relevant identified use(s) listed in Section 1 the advice mentioned in this section 7 is to be observed.

8. Exposure Controls/Personal Protection Control parameters Components with workplace control parameters No occupational exposure limits known.

Exposure controls Personal protective equipment Respiratory protection: Respiratory protection in case of vapour/aerosol release. Particle filter with medium efficiency for solid and liquid particles (e.g. EN 143 or 149, Type P2 or FFP2) Hand protection: Chemical resistant protective gloves (EN 374) Suitable materials short-term contact and/or splashes (recommended: At least protective index 2, corresponding > 30 minutes of permeation time according to EN 374) butyl rubber (butyl) - 0.7 mm coating thickness nitrile rubber (NBR) - 0.4 mm coating thickness Supplementary note: The specifications are based on tests, literature data and information of glove manufacturers or are derived from similar substances by analogy. Due to many conditions (e.g. temperature) it must be considered, that the practical usage of a chemical-protective glove in practice may be much shorter than the permeation time determined through testing. Manufacturer's directions for use should be observed because of great diversity of types. Eye protection: Safety glasses with side-shields (frame goggles) (e.g. EN 166) Body protection: Protective suit General safety and hygiene measures Handle in accordance with good industrial hygiene and safety practice. Wearing of closed work clothing is recommended. Hands and/or face should be washed before breaks and at the end of the shift.

9. Physical and Chemical Properties Information on basic physical and chemical properties

Page: 5/9 BASF Safety data sheet according to Regulation (EC) No. 1907/2006 Date / Revised: 07.12.2011 Version: 1.0 Product: Infineum V 350 (ID no. 30535415/SDS_GEN_EU/EN) Date of print 08.12.2011 Form: Colour: Odour: Flash point: Solubility in water: Self ignition:

liquid colourless of petroleum distillate (e.g. gasoline, kerosene) > 150.0 °C (ASTM D93) insoluble (20.0 °C) not self-igniting

Thermal decomposition: No decomposition if stored and handled as prescribed/indicated. Viscosity, kinematic: 250.00 - 500.00 mm2/s (ASTM D445) (100 °C) 2,000.00 - 3,500.00 mm2/s (ASTM D445) (40 °C) Explosion hazard: not explosive

Other information Hygroscopy: Non-hygroscopic Other Information: If necessary, information on other physical and chemical parameters is indicated in this section.

10. Stability and Reactivity Reactivity Corrosion to metals: Reactions with water/air:

No corrosive effect on metal. Reaction with:

water

Flammable gases: Toxic gases: Corrosive gases: Smoke or fog: Peroxides:

no no no no no

Reaction with: Flammable gases: Toxic gases: Corrosive gases: Smoke or fog: Peroxides:

air no no no no no

Chemical stability The product is stable if stored and handled as prescribed/indicated. Peroxides:

0.000 % The product does not contain peroxides.

Possibility of hazardous reactions No hazardous reactions when stored and handled according to instructions.

Conditions to avoid Avoid all sources of ignition: heat, sparks, open flame. Avoid electro-static discharge.

Page: 6/9 BASF Safety data sheet according to Regulation (EC) No. 1907/2006 Date / Revised: 07.12.2011 Version: 1.0 Product: Infineum V 350 (ID no. 30535415/SDS_GEN_EU/EN) Date of print 08.12.2011

Incompatible materials Substances to avoid: strong acids, strong bases, strong oxidizing agents

Hazardous decomposition products Hazardous decomposition products: No hazardous decomposition products if stored and handled as prescribed/indicated.

11. Toxicological Information Information on toxicological effects Acute toxicity Assessment of acute toxicity: Virtually nontoxic after a single ingestion. Experimental/calculated data: LD50 rat (oral): > 2,000 mg/kg Irritation Assessment of irritating effects: Not irritating to the eyes. Not irritating to the skin.

Respiratory/Skin sensitization Assessment of sensitization: There is no evidence of a skin-sensitizing potential. Germ cell mutagenicity Assessment of mutagenicity: No data was available concerning mutagenic activity. The chemical structure does not suggest a specific alert for such an effect. The product has not been tested. The statement has been derived from the properties of the individual components. Carcinogenicity Assessment of carcinogenicity: The whole of the information available provides no indication of a carcinogenic effect. Reproductive toxicity Assessment of reproduction toxicity: No data for product. No effects anticipated Other relevant toxicity information

Page: 7/9 BASF Safety data sheet according to Regulation (EC) No. 1907/2006 Date / Revised: 07.12.2011 Version: 1.0 Product: Infineum V 350 (ID no. 30535415/SDS_GEN_EU/EN) Date of print 08.12.2011 The product has not been tested. The statements on toxicology have been derived from the properties of the individual components.

12. Ecological Information Toxicity Assessment of aquatic toxicity: The product has not been tested. The statement has been derived from the properties of the individual components. Toxicity to fish: LC50 > 100 mg/l Microorganisms/Effect on activated sludge: EC0 > 1 - 10 mg/l

Persistence and degradability Elimination information: Not readily biodegradable (by OECD criteria).

Bioaccumulative potential Assessment bioaccumulation potential: Significant accumulation in organisms is not to be expected. Discharge into the environment must be avoided.

Mobility in soil (and other compartments if available) Assessment transport between environmental compartments: No data available.

Results of PBT and vPvB assessment According to Annex XIII of Regulation (EC) No.1907/2006 concerning the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH): The product does not contain a substance fullfilling the PBT (persistent/bioaccumulative/toxic) criteria or the vPvB (very persistent/very bioaccumulative) criteria.

Additional information Add. remarks environm. fate & pathway: At the present state of knowledge, no negative ecological effects are expected. Other ecotoxicological advice: The local regulations on waste-water treatment must be followed. The product has not been tested. The statements on ecotoxicology have been derived from the properties of the individual components.

13. Disposal Considerations

Page: 8/9 BASF Safety data sheet according to Regulation (EC) No. 1907/2006 Date / Revised: 07.12.2011 Version: 1.0 Product: Infineum V 350 (ID no. 30535415/SDS_GEN_EU/EN) Date of print 08.12.2011

Waste treatment methods Must be disposed of or incinerated in accordance with local regulations.

Contaminated packaging: Uncontaminated packaging can be re-used. Packs that cannot be cleaned should be disposed of in the same manner as the contents.

14. Transport Information Land transport ADR Not classified as a dangerous good under transport regulations RID Not classified as a dangerous good under transport regulations

Inland waterway transport ADN Not classified as a dangerous good under transport regulations

Sea transport IMDG Not classified as a dangerous good under transport regulations

Air transport IATA/ICAO Not classified as a dangerous good under transport regulations

15. Regulatory Information Safety, health and environmental regulations/legislation specific for the substance or mixture If other regulatory information applies that is not already provided elsewhere in this safety data sheet, then it is described in this subsection.

Chemical Safety Assessment Chemical Safety Assessment not yet performed due to registration timelines

Page: 9/9 BASF Safety data sheet according to Regulation (EC) No. 1907/2006 Date / Revised: 07.12.2011 Version: 1.0 Product: Infineum V 350 (ID no. 30535415/SDS_GEN_EU/EN) Date of print 08.12.2011

16. Other Information Due to the merger of Cognis and BASF Group all (Material) Safety Data Sheets have been reassessed on the basis of consolidated information. This may have resulted in changes to the (Material) Safety Data Sheets. In case you have questions concerning such changes please contact us at the address mentioned in Section 1. The data contained in this safety data sheet are based on our current knowledge and experience and describe the product only with regard to safety requirements. The data do not describe the product's properties (product specification). Neither should any agreed property nor the suitability of the product for any specific purpose be deduced from the data contained in the safety data sheet. It is the responsibility of the recipient of the product to ensure any proprietary rights and existing laws and legislation are observed. Vertical lines in the left hand margin indicate an amendment from the previous version.