Retro-reflective photoelectric sensors with polarisation filter Dimensioned drawing
0.3 … 16m 10 - 30 V DC
l Wide voltage range 10 … 30V with PNP switching output l Polarisation filter blocks unwanted reflections l Complementary switching outputs for optimal adaptation to the application l Warning output - for increased availability l Activation input for testing and interlinking
A B C
We reserve the right to make changes • 46_b01e.fm
ISO 9001
IEC 60947...
Indicator diode green Indicator diode yellow Optical axis
Electrical connection IP 67
IEC 60947...
Accessories: (available separately)
l Mounting systems (BT 46.1, BT 46.1.5, BT 46.2) l M12 connectors (KD …) l Ready-made cables (KB …) l Reflectors l Reflective tapes
Typ. operating range limit (TK(S) 100x100) 1) Operating range 2) Light source Wavelength
0.3 … 16m see table LED (modulated light) 660nm (visible red light, polarised)
Timing Switching frequency Response time Delay before start-up
200Hz 2.5ms 100ms
Electrical data Operating voltage UB Residual ripple Bias current Switching output Function characteristics PRK 46/44(-12; 2000) IPRK 46…, PRK… .8… Signal voltage high/low Output current
Environmental data -20°C … +55°C/-40°C … +55°C 2, 3 II, all-insulated IP 67 IEC 60947-5-2
Options Warning output autoControl Signal voltage high/low Output current Activation input active Transmitter active/not active Activation/disable delay Input resistance 1) 2) 3) 4)
Diagrams Typ. response behaviour (TK 100x100) Misalignment y [mm]
Ambient temp. (operation/storage) Protective circuit 3) VDE safety class 4) Protection class Standards applied
150 100 y2
50 0 -50
y1
-100 -150
0
2
4
6
8
10
12
14
16
Distance x [m]
Typ. operating range limit: max. attainable range without performance reserve Operating range: recommended range with performance reserve 2=polarity reversal protection, 3=short-circuit protection for all outputs Rating voltage 250VAC
y2 y1 x
Order guide
Remarks Designation
Part No.
with M12 connector complementary switching output warning output activation input
PRK 46/44-S12 IPRK 46/4-S.12 PRK 46/4.8-S12
500 81294 500 80981 500 60920
with 2m cable complementary switching output warning output activation input