Line 8 1, 2, 3-Lamp T8, Direct Distribution Project Information

Features • • • • •

8" aperture suits a variety of recessed applications Continuous louver provides a sleek appearance Available with flush or recessed trim One, two, or three-lamp cross sections Shielding options include parabolic louver, cross baffle, or lens

Project Name

Type

Catalog No.

Date

Description The Line 8 is an eight inch wide recessed fluorescent luminaire designed specifically for mounting in rows. It provides a continuous louver for a sleek appearance. Anodized aluminum louvers are available in natural semispecular or specular finishes. Line 8 is also available with prismatic or translucent opal lenses or straight cross-blade louvers in baked white enamel. Lenses are lay-in type and may be ordered to fit flush or regressed 1¾" above the ceiling plane. Shielding shipped separately.

Ceiling Compatibility Line 8 is designed to fit into lay-in (Type G) grid ceilings or concealed suspension (Type F) ceilings requiring an overlapping flange. It is also available in an end-support (Type GF) model which carries the ceiling board on fixture side flanges (see Technical Installation Data). Fixture in exposed grid ceilings (Type G) will have row interrupting cross tees on 4' centers. For uninterrupted shielding without cross tee use end-of-row and intermediate fixtures. Labels and Electrical UL listed 1598. cUL or CSA. Damp location listed.

Construction Fixture housing is constructed of die formed code gauge steel. Louvers tip in place and are permanently aligned by matching grooves at fixture sides. Name: Test #: Efficiency: LER:

Finish Painted parts are treated with a five-stage phosphate bonding process and finished with a high temperature baked powder coat.

Shape and Dimensions

LINE8-2T8-FA-WCB 14556 65.7% 58

6"

8" C.C. Tees

Ordering Information

Line8



Model Line 8 Line 8 (6" × 8")

Row Length 2' Single 3' Single 4' Single 6' Single 8' Single Indicate row length over 8' in 4' increments Note: Rows over 8' will be configured by Alera. Example: 16' will be (2) 8'. Alternate configurations: contact factory. 2 3 4 6 8 —



Example: L8-16-2T8-F-FA-WCB-EU



LAMP TYPE AND PROFILE 1T8 One T8 Lamp 2T8 Two T8 Lamps 3T8 Three T8 Lamps







Trim Type FS Flush Steel Trim (Grid mounting only) FA Flush Trim (Flange or Grid Flange) RA 1¾" Recessed Trim (Any mounting method)

Mounting Method G Grid (For 1" inverted T-Bar) F Overlap Flange Trim (For hard ceilings) GF Grid Ends, Flange Sides (For use where ends will sit on T-Bar and sides will support ceiling tile) (Single fixtures only)

Shielding LD Low Iridescent SemiSpecular Louver LS Low Iridescent Specular Louver WCB White Cross Baffle A12 Acrylic Pattern 12 Prismatic Lens A19 Acrylic Pattern 19 Prismatic Lens OA Opal Acrylic Lens

— U 120 277 347

Voltage 120V-277V 120V 277V 347V

Ballast E Electronic, Instant Start (Std. for T8) EP Electronic, Programmed Start (Std. for T5 & T5HO, optional for T8) ED Electronic, Dimming (Must specify) ESD Electronic, Step Dimming Unless specified, Alera will use fewest ballasts possible.

Options LR Left/Right Switching (2-Lamp only)2 IBOB Inboard/Outboard Switching (3-Lamp only)2 GLR Fast Blow Fuse GMF Slow Blow Fuse EL Emergency Battery Pack1, 2 EMC One Emergency Circuit2, 3 NLC Night Light Circuit2, 3

Specify voltage. For additional, specify quantity before nomenclature (Example: 2EL120). Not available with all configurations; some limitations apply. Contact factory for details. 3 One extra feed drop per EMC/NLC. For through wiring, contact factory. 1 2

Page 1/3 Rev. 06/16/13 © 2013 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com

Recessed / L8

Line 8 1, 2, 3-Lamp T8, Direct Distribution Cross section Parabolic Louver

Straight Blade Louver

8" C.C. Tees

1-Lamp

Lens

6"

Note: Measurements vary based on trim selected. Please see Technical Installation Data for complete information.

Photometric Data

Ballast Ballast Factor Lamp Lumens per Lamp Watts Shielding Angle Spacing Criterion Luminous Opening in Feet

LINE884-132G-WCB-E Line 8 Architectural Recessed 8 × 48 1-Lamp with White Cross Baffle ICN-2P32-SC 0.88 F32T8 2900 30 0º = 46  90º = 40 0º = 0.98  90º = 1.38 Length: 3.92 Width: 0.56 Height: 0.00

Avg. Luminance (Candela/Sq. M.) Coefficients of Utilization (%) 0 30 40 45 50 55 60 65 70 75 80 85

0.0 22.5 45.0 67.5 90.0

4580 3261 2560 2184 1976 1847 1726 1624 1534 1440 1327 1125

4580 3414 2772 2365 2060 1906 1765 1636 1534 1440 1327 1182

4580 3958 3501 3134 2647 2180 1922 1798 1677 1554 1440 1294

4580 4626 4282 3724 3059 2582 2540 2390 2165 1895 1666 1463

4580 5028 4698 4022 3234 3018 3089 3156 3097 2728 2259 1744

Zonal Lumen Summary Zone

0-30 0-40 0-60 0-90 0-180

Lumens % Lamp % Fixt. 685 1085 1671 1972 1972

23.6 37.4 57.6 68.0 68.0

34.8 55.0 84.7 100.0 100.0

RCR

Luminaire

Angle

Luminaire Data Test 14416

RC RW 1 2 3 4 5 6 7 8 9 10

70 75 69 63 58 54 50 47 44 41 38

80 50 30 72 69 64 59 57 52 51 45 46 40 42 36 38 32 35 29 32 27 30 25

10 67 56 47 41 36 32 29 26 23 21

70 73 67 62 57 53 49 46 43 40 38

70 50 30 70 68 62 58 56 51 50 45 45 40 41 36 38 32 34 29 32 27 30 25

10 66 55 47 41 36 32 28 26 23 21

50 67 60 54 48 44 40 37 34 31 29

50 30 65 57 50 44 39 35 32 29 26 24

10 64 54 46 40 35 31 28 26 23 21

Indoor Candela Plot 90

0 0 59 50 43 38 33 30 27 24 22 20

75

60 500 45

RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance

Energy Data Total Luminaire Efficiency Luminaire Efficacy Rating (LER) ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens

68.0% 58 Yes-VDT Normal Use $4.14 based on 3000 hrs. and $0.08 per KWH

1000 0 0.0

15 30 Horiz 0-180 90.0 45.0

Test Date 10/18/06

Photometric Data

Ballast Ballast Factor Lamp Lumens per Lamp Watts Shielding Angle Spacing Criterion Luminous Opening in Feet

LINE8 84-132G-LD-E Line 8 Architectural Recessed 8 × 48 1-Lamp with Semi-Specular Louver ICN-2P32-SC 0.88 F32T8 2900 30 0º = 31  90º = 38 0º = 1.23  90º = 1.72 Length: 3.88 Width: 0.52 Height: 0.00

Avg. Luminance (Candela/Sq. M.) Coefficients of Utilization (%) 0 30 40 45 50 55 60 65 70 75 80 85

0.0 22.5 45.0 67.5 90.0

7250 6961 6547 6111 5270 3265 1014 454 265 165 92 61

7250 7553 7758 7726 7171 5190 1974 581 328 206 92 61

7250 8544 9534 9341 7984 5841 3212 1363 452 268 184 122

7250 9629 10649 9582 7387 4651 3937 2916 1248 433 246 184

7250 10060 11066 9937 6706 4818 4492 4077 1466 577 369 184

Zonal Lumen Summary Zone

0-30 0-40 0-60 0-90 0-180

Lumens % Lamp % Fixt. 1157 2019 3372 3541 3541

20.0 34.8 58.1 61.0 61.0

32.7 57.0 95.2 100.0 100.0

RCR

Luminaire

Angle

Luminaire Data Test 14411

RC RW 1 2 3 4 5 6 7 8 9 10

70 68 63 58 54 50 46 43 40 37 35

80 50 30 66 64 59 56 53 49 47 43 43 38 39 34 35 30 32 27 29 25 27 22

10 62 53 45 39 34 30 27 24 21 19

70 66 61 57 52 48 45 42 39 36 34

70 50 30 64 63 58 55 52 48 47 42 42 37 38 33 35 30 32 27 29 25 27 22

10 61 52 45 39 34 30 27 24 21 19

50 62 56 50 45 41 37 34 31 28 26

50 30 60 53 47 41 37 33 30 27 24 22

10 59 51 44 38 34 30 26 24 21 19

Indoor Candela Plot 90

0 0 54 48 41 36 32 28 25 22 20 18

75

60 850 45

RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance

Energy Data Total Luminaire Efficiency Luminaire Efficacy Rating (LER) ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens

61.0% 104 Yes-VDT Normal Use $2.31 based on 3000 hrs. and $0.08 per KWH

0

1700

0.0

15 30 Horiz 0-180 90.0 45.0

Test Date 10/17/06 Page 2/3 Rev. 06/16/13 © 2013 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com

Recessed / L8

Line 8 1, 2, 3-Lamp T8, Direct Distribution Cross section Parabolic Louver

Straight Blade Louver

8" C.C. Tees

2-Lamp

Lens

6"

Note: Measurements vary based on trim selected. Please see Technical Installation Data for complete information.

Photometric Data

Ballast Ballast Factor Lamp Lumens per Lamp Watts Shielding Angle Spacing Criterion Luminous Opening in Feet

LINE8-2T8-G-WCB-E-4 Line 8 Architectural Recessed 8 × 48 2-Lamp with White Cross Baffle ICN-2P32-SC 0.88 F32T8 2900

Avg. Luminance (Candela/Sq. M.) Coefficients of Utilization (%)

56 0º = 46  90º = 40 0º = 0.95  90º = 1.20 Length: 3.92 Width: 0.56 Height: 0.00

0 30 40 45 50 55 60 65 70 75 80 85

0.0 22.5 45.0 67.5 90.0

9434 6466 4954 4188 3860 3591 3334 3121 2939 2747 2541 2082

9434 6772 5338 4480 3974 3676 3413 3167 2968 2766 2513 2082

9434 7542 6177 5485 4829 4138 3776 3423 3140 2880 2626 2307

9434 8232 7399 7191 6736 5967 4972 4432 3943 3467 3021 2476

9434 8770 8532 8509 8208 7113 5992 6010 5706 5039 3953 2982

Zonal Lumen Summary Zone

0-30 0-40 0-60 0-90 0-180

Lumens % Lamp % Fixt. 1358 2086 3245 3810 3810

23.4 36.0 56.0 65.7 65.7

35.6 54.7 85.2 100.0 100.0

RCR

Luminaire

Angle

Luminaire Data Test 14417

RC RW 1 2 3 4 5 6 7 8 9 10

70 72 66 61 56 52 49 45 42 40 37

80 50 30 69 67 61 57 55 50 49 44 44 39 40 35 37 32 34 29 31 26 29 24

10 65 54 46 40 35 31 28 25 23 21

70 70 65 60 55 51 47 44 41 39 37

70 50 30 68 66 60 57 54 49 48 43 44 39 40 35 36 31 33 28 31 26 29 24

10 64 53 46 40 35 31 28 25 23 21

50 65 58 52 47 42 39 35 33 30 28

50 30 63 55 48 42 38 34 31 28 26 24

10 62 52 45 39 34 31 27 25 23 21

Indoor Candela Plot 90

0 0 57 49 42 37 32 29 26 23 21 19

75

60 1000 45

RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance

Energy Data Total Luminaire Efficiency Luminaire Efficacy Rating (LER) ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens

65.7% 60 Noncompliant $4.00 based on 3000 hrs. and $0.08 per KWH

2000 0 0.0

15 30 Horiz 0-180 90.0 45.0

Test Date 10/18/06

Photometric Data

Ballast Ballast Factor Lamp Lumens per Lamp Watts Shielding Angle Spacing Criterion Luminous Opening in Feet

LINE884-232G-LD-E Line 8 Architectural Recessed 8 × 48 2-Lamp with Semi-Specular Louver ICN-2P32-SC 0.88 2900 56 0º = 31  90º = 29 0º = 1.21  90º = 1.28 Length: 3.88 Width: 0.52 Height: 0.00

Avg. Luminance (Candela/Sq. M.) Coefficients of Utilization (%) 0 30 40 45 50 55 60 65 70 75 80 85

0.0 22.5 45.0 67.5 90.0

7890 7442 6943 6489 5503 3125 768 404 218 103 31 0

7890 8033 7654 7153 6283 4362 1398 505 281 144 61 0

7890 8267 7549 7175 6914 5925 3820 1275 406 227 123 0

7890 8125 7605 7809 8092 6939 4460 2689 952 350 184 0

7890 8144 7946 8473 9238 7720 4951 3888 1201 536 277 122

Zonal Lumen Summary Zone

0-30 0-40 0-60 0-90 0-180

Lumens % Lamp % Fixt. 1209 1956 3244 3402 3402

20.8 33.7 55.9 58.6 58.6

35.5 57.5 95.4 100.0 100.0

RCR

Luminaire

Angle

Luminaire Data Test 14407

RC RW 1 2 3 4 5 6 7 8 9 10

70 65 61 56 52 48 44 41 39 36 34

80 50 30 63 61 57 53 51 47 46 41 41 37 37 33 34 29 31 27 29 24 27 22

10 60 51 44 38 33 29 26 23 21 19

70 64 59 55 50 47 43 40 38 35 33

70 50 30 62 60 56 53 50 46 45 41 41 36 37 32 34 29 31 26 28 24 26 22

10 59 50 43 38 33 29 26 23 21 19

50 59 54 48 44 39 36 33 30 28 26

50 30 58 51 45 40 36 32 29 26 24 22

10 57 49 43 37 33 29 26 23 21 19

Indoor Candela Plot 90

0 0 52 46 40 35 31 27 24 22 20 18

75

60 800 45

RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance

Energy Data Total Luminaire Efficiency Luminaire Efficacy Rating (LER) ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens

58.6% 53 Noncompliant $4.53 based on 3000 hrs. and $0.08 per KWH

0

1600

0.0

15 30 Horiz 0-180 90.0 45.0

Test Date 10/17/06 Page 3/3 Rev. 06/16/13 © 2013 Alera Lighting, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Alera Lighting reserves the right to change specifications without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.aleralighting.com

Recessed / L8