Fluorescent lamp Bonalux®Super NL-T5 54W/840/G5 Logistic Data Article No. Code Product EAN Customs tariff no. Box quantitiy (pcs.) EAN Box Gross weight of box in kg Length of box in m Width of box in m Height of box in m Pieces per palett EAN Palett ETIM Class ETIM class name
Electric Parameters Lamp nominal wattage Rated wattage Nominal current (mA)
54 W 54.0 W 455 mA
Light Application Parameters Luminous flux max. luminous flux max. luminous flux at Rated lamp luminous flux Luminous efficiency of lamp Radium light colour Colour temperature Colour rendering index Ra Colour rendering group Mean luminance
4450 lm 5000 lm 35 °C 4450 lm 93 lm/W white 4000 K 80-89 80-89 (Klasse 1B) 2,9
Radium Lampenwerk GmbH · P.O. Box 1440 · 51678 Wipperfürth/Germany · Dr.-Eugen-Kersting-Str. 6 · 51688 Wipperfürth/Germany Managing Director: Andreas Steinert · Chairman of the Supervisory Board: Peter Mannhart Registry Court: Köln HRB 37474 · WEEE-Reg-Nr. DE 36655118
Service Life Mean service life Info about service life Lamp survival factor at 2000h Lamp survival factor at 4000h Lamp survival factor at 6000h Lamp survival factor at 8000h Lamp survival factor at 12000h Lamp survival factor at 16000h Lamp survival factor at 20000h Lumen maintenance at 2000h Lumen maintenance at 4000h Lumen maintenance at 6000h Lumen maintenance at 8000h Lumen maintenance at 12000h Lumen maintenance at 16000h Lumen maintenance at 20000h Operation mode for LLMF/LSF
Specification Diameter max. Length max. Controllable (in suitable circuit) Energy Label Suitable for indoors Mercury content Base Lamp shape Colour
16 mm 1149 mm + A Yes 1.5 mg G5 Tube, two bases other
Notes on Operation Starter / Ingnitor Ignition assured down to about (°C) Operation with ECG
EVG -20 +
Miscellaneous ILCOS name LBS name
FDH-54/840-L/P-G5-16/1150 T16 54W/840 G5
Notes: Fluorescent lamp Bonalux? Super Please, note: when changing lamps take care about the electric data of lamp and control gear, mix-up possible!
Radium Lampenwerk GmbH · P.O. Box 1440 · 51678 Wipperfürth/Germany · Dr.-Eugen-Kersting-Str. 6 · 51688 Wipperfürth/Germany Managing Director: Andreas Steinert · Chairman of the Supervisory Board: Peter Mannhart Registry Court: Köln HRB 37474 · WEEE-Reg-Nr. DE 36655118
Notes
Base G5 IEC/EN 60061-1 sheet 7004-52-5
Circuit diagrams One-lampe ciruit with electronic ballast Key: VG = ballast electronic (ECG) P = phase N = zero potential Ctrl = Controller, dimmer The required control gear (here electronic ballast) for the lamp’s operation is usually mounted in the suitable luminaire in an appropriate electric circuit. Changes of any kind are to be conducted by qualified and specialised staff, only. Thus, this circuit example is to be understood merely as a technical background information for interested users.
Circuit with multi electronic ballast Key: VG = ballast electronic (ECG) P = phase N = zero potential Ctrl = Controller, dimmer The required control gear (here electronic ballast) for the lamp’s operation is usually mounted in the suitable luminaire in an appropriate electric circuit. Changes of any kind are to be conducted by qualified and specialised staff, only. Thus, this circuit example is to be understood merely as a technical background information for interested users.
Radium Lampenwerk GmbH · P.O. Box 1440 · 51678 Wipperfürth/Germany · Dr.-Eugen-Kersting-Str. 6 · 51688 Wipperfürth/Germany Managing Director: Andreas Steinert · Chairman of the Supervisory Board: Peter Mannhart Registry Court: Köln HRB 37474 · WEEE-Reg-Nr. DE 36655118
Spectrum Natural daylight is a mixture of direct sunlight and the light of the sky. Therefore, its spectral composition changes permanently due to the changing time of day. The standardised light classification D65 corresponds to a daylight with a colour temperature of approximately 6500 K. Every fluorescent lamp type has got an individual spectral power distribution according to its phosphor coating inside the bulb. From this result important properties light colour or colour rendering. Visible region from 380 to 780 nm; height of graph corresponding with relative spectral emission (400mW/klm) per 10nm.
light colour 840 Spectralux® white (21)
daylight(D 65)
General notes The technical design data in accordance with DIN and IEC. The producer does not take any responsibility for damage to persons or property in case of unsuitable operation or handling of the product. Operating data and dimensions are valid within the usual tolerances. Related lamp types (different bases, mains voltages) may be available on request. Sale and delivery are effected in accordance with the Radium Terms of Delivery and Payment valid on the day of conclusion of contract. Packing units offer economical advantages to the purchase and logistic department. Please match your quantity volume accordingly. For orders of a minimum quantity (clefts) with a lamp model the amount lower than the volume of each packaging unit, we will invoice 10 % additional charge per lamp type. Technical changes and terms of delivery are reserved. Manipulation of any kind to packaging or product is not permissible as this will violate Radium brand rights. Furthermore, technical properties of the product can change to its disadvantage or even destruction. Therefore, Radium cannot be responsible for consequential damages. Subject to change without notice. Errors and omissions excepted. ® = Registered trademark
All technical data without guarantee.
Radium Lampenwerk GmbH · P.O. Box 1440 · 51678 Wipperfürth/Germany · Dr.-Eugen-Kersting-Str. 6 · 51688 Wipperfürth/Germany Managing Director: Andreas Steinert · Chairman of the Supervisory Board: Peter Mannhart Registry Court: Köln HRB 37474 · WEEE-Reg-Nr. DE 36655118
Jan 15, 2013 - Logistic Data. Article No. ... lamps take care about the electric data of lamp and control gear, mix-up possible! ... VG = ballast electronic (ECG).
20 nov. 2015 - lls s'engagent à plus de solidarité, de cohésion et à une mutualisation des efforts dans l'action à tous les niveaux pour avoir une position ...
6 avr. 2016 - La radio confirme que le G5 s'intègre parfaitement entre l'iPhone 6 (à gauche) et ... que la batterie du G5 s'intègre ... Circuit intégré de gestion.
Étape 1 — Carte mère. Placez votre g5 sur une surface appropriée.. Retirez le cordon d'alimentation.. Préparer deux pilotes vis; T10 et Phillips (T15 peut ...
Jun 20, 2006 - Tools. The following tools are required to service the computer: ..... Pro) bus. It's an enhanced PCI bus with extra functionality that is up to 8 times faster than a 66. MHz PCI port. ...... 110 Power Mac G5 Take Apart. Procedure.
Jun 20, 2006 - The Power Mac G5 computer comes with a graphics card installed in ...... Angle the logic board into the enclosure so that the port edge goes in ...
iMac G5 17 "Remplacement Modèle A1058 Alimentation ... Gardez ces électrons circulant en remplaçant votre alimentation cassé! OUTILS: ... Il sera nécessaire de travailler à partir des côtés alternés jusqu'à ce que le connecteur est libre.
Is it nightmare or dream ? G5. G. The morning star, is so afar. Gsus4/A. And yet so close to me. G5. G. I see it rise, in a fool's disguise. Gsus4/A. How could it be.
The white index mark should be located in the marked index area. ..... Indicación: En el modelo GAMMA G7 se adjunta una llave especial. ⢠Gire la pala en 180° .... di questa avvertenza può portare a lesioni di piccola o media portata. (Sfondo: .
18 nov. 2014 - Vers un nouveau modèle de R&D dans les sciences de la vie. Christophe Thurieau ... de l'Enseignement supérieur et de la Recherche. 13h .... économique et de créer des emplois, Horizon 2020 a ..... Conseil scientifique de l'Institut de