Timing switch for 1 second to 90 minutes ... Activates the ventilator at set time (1 s to 3 min) after switching the lighting on ... cs3-1b_aj.qxd 7.8.2006 18:57 Page 1 ...
66KB taille 58 téléchargements 308 vues
cs3-1b_aj.qxd

7.8.2006

18:57

Page 1

N

L

N 1

1 min.– 1 h 30 min. 8 s –11 min. 1 s –1 min. 25s

CS3-1B

0,1 s – 20 s

Activates the ventilator at set time (1 s to 3 min) after switching the lighting on and deactivates it at set time after switching the lighting off.

CS3-1B Timing switch for 1 second to 90 minutes (for ventilators) Activates the ventilator at set time (1 s to 3.5 min) after switching the lighting on and deactivates it at defined time after switching the lighting off.

CERTIFICATE OF GUARANTEE (guarantee period for the product amounts to 2 years) product No.:

date of sale:

examined by:

stamp of shop:

Send the product for guarantee and after-guarantee service to manufacturer's address. ELEKTROBOCK CZ s.r.o. Blanenská 1763 Kuřim 664 34 Tel./fax: +420 541 230 216 Technická podpora (do 14h) Mobil: +420 724 001 633

www.elbock.cz

MADE IN CZECH REPUBLIC

MADE IN CZECH REPUBLIC

cs3-1b_aj.qxd

7.8.2006

18:57

Page 2

CS3-1B CS3-1B serves for delayed switching on/off of the ventilator in dependence to lighting. The ventilator is activated in time interval of 1 second to 3.5 minutes after switching the lighting on. The interval is set on P1 trimmer (delay) with using of a small screwdriver. The ventilator is deactivated at time 1 second to 90 minutes after switching the lighting off. This interval is set by miniature switch according to the table and by P2 trimmer (timing) with using of a small screwdriver.

Summary of produced types: CS3-1

activates the ventilator after switching the lighting off. CS3-2 timing switch for lighting. CS3-4 is switched on immediately after push ing the button, but the timing itself starts only after button disconnecting - connection without neutral lead. CS3-4M multifunctional timing switch, 8 functions in one connection - connection without neutral lead.

Specification: Nominal operating voltage Nominal frequency of network Resistance load Inductive load

Un=230V fn=50 Hz 20–350 W 20–200 VA

(of ventilator)

Limit of interference suppression Cross section of installation leads Ambient temperature

tcs= ts+tc-tx tcs= period of ventilator running ts = period of lighting tc = the time set on P2 of CS3-1B tx = the time set on P1 of CS3-1B

R 02 0,5 mm2 -10°C to + 55°C

It is necessary to switch off the distribution system in the course of installation, replacement of bulb or fuse! Setting the time and installation should be performed system that is not live and by a person with appropriate qualification in electrical engineering.