«Vital Development Corporation» OJSC 194156, Saint-Petersburg, Engelsa prospect, 27, build 38 Теlephone: +7 (812) 326-38-47, e-mail:
[email protected]
CATALOGUE CONTENTS Clinical chemistry Specific proteins ........................................................................................................................................................................................ 2 Lipids .............................................................................................................................................................................................................. 3 Substrates .................................................................................................................................................................................................... 4 Enzymes ....................................................................................................................................................................................................... 7 Electrolytes ................................................................................................................................................................................................ 10 Calibrators .................................................................................................................................................................................................. 12 Control materials ................................................................................................................................................................................... 13 New ELISA Thyroid diagnostics ELISA kits ........................................................................................................................................................... 14 Tumor markers ELISA kits ................................................................................................................................................................... 15 New LATEX SLIDE TESTS Latex slide tests ........................................................................................................................................................................................... 16
Equipment Water Purification System PRODEION 10 VS ........................................................................................................................................ 17 Water Purification System PRODEION 20 VS ........................................................................................................................................ 18 New Water Purification System PRODEION 40 VS ........................................................................................................................................ 19
� marked
2 back to CONTENTS
CLINICAL CHEMISTRY specific proteins Product form
Method
Automation
R1: 45 ml, R2: 2 ml R1: 2 x 45 ml, R2: 4 ml
Fluid
Immunoturbidimetric
Semi-auto / Auto
Until expiry date at 2...8° C
5–300 mg/dl (0,05–3 g/L)
50 tests
R1: 45 ml, R2: 2,1 ml
Fluid
Immunoturbidimetric
Semi-auto / Auto
Until expiry date at 2...8° C
3–330 mg/dl (0,03–3,3 g/L)
ASL-O
40 tests 150 tests
R1: 48 ml, R2: 3,2 ml, Calibrator: 0,5 ml R1: 2 x 90 ml, R2: 2 x 6 ml, Calibrator: 0,5 ml
Fluid
Immunoturbidimetric
Semi-auto / Auto
Until expiry date at 2...8° C
25–300 IU/ml
B 47.01* B 47.11* B 47.21*
C3 Complement
50 tests 100 tests 200 tests
R1: 45 ml, R2: 2 ml, Calibrator: 0,5 ml R1: 90 ml, R2: 4 ml, Calibrator: 0,5 ml R1: 2 x 90 ml, R2: 2 x 4 ml, Calibrator: 0,5 ml
Fluid
Immunoturbidimetric
Semi-auto / Auto
Until expiry date at 2...8° C
20–400 mg/dl (0,2–4,0 g/L)
B 48.01* B 48.11* B 48.21*
C4 Complement
50 tests 100 tests 200 tests
R1: 45 ml, R2: 1,8 ml, Calibrator: 0,5 ml R1: 90 ml, R2: 3,5 ml, Calibrator: 0,5 ml R1: 2 x 90 ml, R2: 2 x 3,5 ml, Calibrator: 0,5 ml
Fluid
Immunoturbidimetric
Semi-auto / Auto
Until expiry date at 2...8° C
2–80 mg/dl (0,02–0,8 g/L)
B 40.11* B 40.31*
CRP
100 tests 500 tests
R1: 100 ml, R2: 5 ml, Calibrator: 1 ml R1: 2 x 250 ml, R2: 25 ml, Calibrator: 1 ml
Fluid
Immunoturbidimetric
Semi-auto / Auto
Until expiry date at 2...8° C
0,3–22 mg/dl (3–220 mg/L)
B 43.11* B 43.31*
IgA
100 tests 400 tests
R1: 90 ml, R2: 3 ml, Calibrator: 0,5 ml R1: 2 x 180 ml, R2: 12 ml, Calibrator: 0,5 ml
Fluid
Immunoturbidimetric
Semi-auto / Auto
Until expiry date at 2...8° C
6–600 mg/dl (0,06–6 g/L)
B 45.11* B 45.31*
IgG
100 tests 400 tests
R1: 90 ml, R2: 5 ml, Standrd: 0,5 ml R1: 2 x 180 ml, R2: 20 ml, Calibrator: 0,5 ml
Fluid
Immunoturbidimetric
Semi-auto / Auto
Until expiry date at 2...8° C
90–2700 mg/dl (0,9–27 g/L)
B 44.11* B 44.31*
IgM
100 tests 400 tests
R1: 90 ml, R2: 4 ml, Calibrator: 0,5 ml R1: 2 x 180 ml, R2: 16 ml, Standar d: 0,5 ml
Fluid
Immunoturbidimetric
Semi-auto / Auto
Until expiry date at 2...8° C
10–500 mg/dl (0,1–5 g/L)
B 41.12* B 41.22*
Microalbumin
100 tests 200 tests
R1: 90 ml, R2: 7,6 ml, Calibrator: 1 ml R1: 2 x 90 ml, R2: 2 x 7,6 ml, Calibrator: 1 ml
Fluid
Immunoturbidimetric
Semi-auto / Auto
Until expiry date at 2...8° C
7,0–400 mg/L
RF
50 tests 100 tests 50 tests
R1: 25 ml; R2: 4,5 ml R1: 45 ml; R2: 2 x 4,5 ml R1: 45 ml; R2: 4,5 ml
Fluid
Immunoturbidimetric
Semi-auto / Auto
Until expiry date at 2...8° C
3-500 IU/ml
Transferrin
50 tests 100 tests
R1: 45 ml, R2: 1,5 ml, Calibrator: 0,5 ml R1: 2 x 45 ml, R2: 2 x 1,5 ml, Calibrator: 0,5 ml
Fluid
Immunoturbidimetric
Semi-auto / Auto
Until expiry date at 2...8° C
40–500 mg/dl (0,4–5,0 g/L)
Ref
Parameter
Kit Size
B 50.01* B 50.11*
Apo A1
25 tests 50 tests
B 51.01*
Apo B
B 46.01* B 46.11*
Kit Composition
Storage and stability
Measuring range
New B 52.01 B 52.11 B 52.21
B 42.01* B 42.11*
* � marked
«Vital Development Corporation» OJSC
3 back to CONTENTS
CLINICAL CHEMISTRY lipids Ref
Parameter
Kit size
Kit Composition
B 13.11* B 13.21* B 13.31*
Cholesterol
2 x 100 ml 2 x 250 ml 4 x 250 ml
R1: 2 x 100 ml, Calibrator: 1 x 1,5 ml R1: 2 x 250 ml, Calibrator: 1 x 1,5 ml R1: 4 x 250 ml, Calibrator: 2 x 1,5 ml
B 13.12* B 13.22* B 13.32*
Cholesterol
2 х 100 ml 2 х 250 ml 4 х 250 ml
R1: 2 х 100 ml, R2: 2 vials, Calibrator: 1 х 1,5 ml R1: 2 х 250 ml, R2: 2 vials, Calibrator: 1 х 1,5 ml R1: 4 х 250 ml, R2: 4 vials, Calibrator: 2 х 1,5 ml
Product form
Method
Automation
Storage
Opened reagents stability
Measuring range
Fluid
Enzymatic End point Colorimetric method (ChOD-PAP)
Manual / Auto
24 months at 2...8° C
Calibrator – 1 month at 2..8 °С Reagent 1 – until expiry date at 2...8 °С
0,5–25,8 mmol/L (19–1000 mg/dl)
Lyophilized
Enzymatic End point Colorimetric method (ChOD-PAP)
Manual / Auto
24 months at 2...8° C
Calibrator – 1 month at 2...8 °С
0,5–25,8 mmol/L (19–1000 mg/dl)
Manual
12 months at 18...25° C
Reagent 1 – until expiry date at 18...25 °С Calibrator – 1 month at 18...25 °С
0,2–5,0 mmol/L (8–190 mg/dl)
B 13.04
HDL-Cholesterol
2 х 50 ml
R1: 2 X 50 ml, Calibrator: 5 ml
Fluid
Phosphotungstate-magnesium precipitation
B 13.05* B 13.15*
HDL-Cholesterol
60 ml 120 ml
R1: 45 ml, R2: 15 ml R1: 2 x 45 ml, R2: 2 x 15 ml
Fluid
Enzymatic Colorimetric, Immunoinhibition method
Semi-auto / Auto
Until expiry date at 2...8° C
Until expiry date at 2...8° C
0,026–4,66 mmol/L (1–180 mg/dl)
B 13.06* B 13.16*
LDL-Cholesterol
60 ml 120 ml
R1: 45 ml, R2: 15 ml R1: 2 x 45 ml, R2: 2 x 15 ml
Fluid
Enzymatic Colorimetric, selective protection method
Semi-auto / Auto
Until expiry date at 2...8° C
Until expiry date at 2...8° C
0,026–10,3 mmol/L (1–400 mg/dl)
Triglycerides
50 ml 2 х 50 ml 2 х 100 ml
R1: 1 х 50 ml, Calibrator: 1 ml R1: 2 х 50 ml, Calibrator: 1 ml R1: 2 х 100 ml, Calibrator: 2 х 1 ml
Fluid
Enzymatic End point Colorimetric method (GPO-PAP)
Manual / Auto
12 months at 2...8° C
Reagent 1 - 6 months at 2..8 °С Calibrator–3 months at 2..8 °С
0,5–8,0 mmol/L (44–701 mg/dl)
Triglycerides
50 ml 2 x 50 ml 2 x 100 ml
R1: 1 x 50 ml, R2: 1 vial, Calibrator: 1 ml R1: 2 x 50 ml, R2: 2 vials, Calibrator: 1 ml R1: 2 x 100 ml, R2: 4 vials, Calibrator: 2 x 1 ml
Lyophilized
Enzymatic End point Colorimetric method (GPO-PAP)
Manual / Auto
36 months at 2...8° C
Reconstituted reagent stability - 6 months at 2..8 °С Calibrator – 3 months at 2..8 °С
0,5–8,0 mmol/L (44–701 mg/dl)
New B 17.01* B 17.11* B 17.21*
B 17.02* B 17.12* B 17.22*
* � marked
«Vital Development Corporation» OJSC
4 back to CONTENTS
CLINICAL CHEMISTRY SUBSTRATES Ref
B 21.02*
B 03.12*
B 03.03
B 04.02 B 04.12
B 04.04* B 04.14*
B 04.08*
B 04.09 B 04.19
* � marked
Parameter
Kit size
Kit Composition
Product form
Method
Automation
Storage
Opened reagents stability
Measuring range
Manual / Auto
24 months at 2...8° C
Reagent 1 – until expiry date at 2...8 °С Calibrator – 6 months at 2...8 °С
10–60 g/L (1,0–6,0 g/dl)
Albumin
2 х 100 ml R1: 2 х 100 ml, Calibrator: 1 ml
Fluid
Colorimetric method (with Bromocresol green).
Bilirubin
138 tests Total 138 tests Direct
R1: 200 ml, R2: 55 ml, R3: 2 ml, R4: 250 ml, Calibrator: 1 vial
Fluid
Colorimetric End point method (Endrassik-Grof )
Manual / Auto
18 months at 18..25° C
Until expiry date at 18...25 °С
8–410 µmol/L (0,5–24 mg/dl)
Bilirubin
138 tests Total 138 tests Direct
R1: 250 ml, R2: 250 ml, R3: 2 x 10 ml, Calibrator: 2 vials
Fluid
Colorimetric End point method (Malloy-Eveline)
Manual / Auto
12 months at 2..8° C
Until expiry date at 18...25 °С
5–340 µmol/L (0,3–20 mg/dl)
Creatinine
200 tests 500 tests
R1: 100 ml, R2: 100 ml, Calibrator: 10 ml, R4: 100 ml R1: 250 ml, R2: 250 ml, Calibrator: 20 ml, R4: 250 ml
Fluid
End point method (Jaffe), with deproteinization
Manual
18 months at 18..25° C
Reagents 1, 2 & 4 – until expiry date at 18..25 °С Calibrator – 12 months at 2...8 °С
50–440 µmol/L (0,6–5,0 mg/dl)
Creatinine
100 ml 400 ml
Fluid
Two point method (Jaffe), Semi-auto / without deproteinization Auto
18 months at 18..25° C
Reagents 1 & 2 – until the expiry date at 18..25 °С Calibrator – 3 months at 18..25 °С
25–885 µmol/L (0,3–10,0 MG/DL)
R1: 50 ml, R2: 50 ml, Calibrator: 5 ml R1: 200 ml, R2: 200 ml, Calibrator: 2 X 5 ml
Creatinine
5 х 10 ml
R1: 1 х 50 ml, R2: 5 vials, Calibrator: 1 ml
Creatinine
R1: 1 х 50 ml, R2: 5 vials, R3: 1 vial, 1 х 6 ml, 5 x 10 ml Calibrator: 1 ml 10 x 10 ml R1: 2 x 50 ml, R2: 10 vials, R3: 2 vials, 2 x 6 ml, Calibrator: 2 ml
Lyophilized
Enzymatic Kinetic Two point UV–method.
Semi-auto / Auto
12 months at 2...8° C
Reagent 1 – until expiry date at 2...8 °С Calibrator – until expiry date at 2...8 °С
25–885 µmol/L (0,3–10,0 mg/dl)
Lyophilized
Enzymatic Colorimetric End point method.
Manual / Semi-Auto
6 months at 2...8° C
Reagent 1 – until expiry date at 2...8 °С Calibrator – 6 months at 2...8 °С
10–885 µmol/L (0,1–10,0 mg/dl)
«Vital Development Corporation» OJSC
5 back to CONTENTS
CLINICAL CHEMISTRY SUBSTRATES Ref
Parameter
Kit size
Kit Composition
Product form
Method
Automation
Storage
Opened reagents stability
Measuring range
Fluid
Enzymatic Colorimetric End point method, GOD PAP
Manual / Auto
24 months at 2...8° C
Reagent 1 – until expiry date at 2...8 °С Calibrator – 6 months at 2...25 °С
1–30 mmol/L (18–540 mg/dl)
B 05.01* B 05.11* B 05.31*
Glucose
2 x 100 ml R1: 2 x 100 ml, Calibrator: 2 ml 2 x 250 ml R1: 2 x 250 ml, Calibrator: 2 ml 4 x 250 ml R1: 4 x 250 ml, Calibrator: 2 x 2 ml
B 05.02* B 05.12* B 05.32*
Glucose
2 x 100 ml R1: 2 x 100 ml, R2: 2 vials, Calibrator: 2 ml 2 x 250 ml R1: 2 x 250 ml, 2 vials, Calibrator: 2 ml 4 x 250 ml R1: 4 x 250 ml, R2: 4 vials, 2 x 2 ml
Lyophilized
Enzymatic Colorimetric method (GODPAP)
Manual / Auto
24 months at 2...8° C
Calibrator – 6 months at 2...25 °С
1–30 mmol/L (18–540 mg/dl)
B 05.04* B 05.14* B 05.34*
Glucose
R1: 2 x 100 ml, R2: 2 vials, Calibrator: 2 ml, R4: 50 ml 2 x 100 ml R1: 2 x 250 ml, R2: 2 vials, Calibrator: 2 ml, 2 x 250 ml R4: 125 ml 4 x 250 ml R1: 4 x 250 ml, R2: 4 vials, Calibrator: 2 x 2 ml, R4: 250 ml
Lyophilized
Enzymatic Colorimetric method (GOD-PAP), with deproteinization
Manual / Auto
24 months at 2...8° C
Reagent 4 – until expiry date at 2...25 °С Calibrator – 6 months at 2...25 °С
1–30 mmol/L (18–540 mg/dl)
B 05.03*
Glucose
1 x 100 ml R1: 1 x 100 ml, R2: 1 vital, Calibrator: 2 ml
Lyophilized
Enzymatic End point UV method (Hexokinase)
Manual / Auto
12 months at 2...8° C
Calibrator – 6 months at 2...8 °С
1–50 mmol/L (18–900 mg/dl)
R1: 1 х 100 ml, Calibrator: 2 ml R1: 2 x 100 ml, Calibrator: 2 ml
Fluid
Enzymatic End point UV method (Hexokinase)
Manual / Auto
18 months at 2…8 °С
Calibrator — 6 months at 2...25 ºC
1 – 50 mmol/L (18 – 900 mg/dL)
R1: 4 x 7.5 ml, R2A: 9.5 ml, R2B: 0.5 ml, R3: 200 ml
Fluid
Immunoturbidimetric latex assay
Semi-auto / Auto
Until expiry date
Until expiry date at 2...8 °С
4–12%
Fluid
Ion exchange batch method
Manual / Semi-Auto
Fluid
Colorimetric method (Cyanide)
Manual / Auto
New Glucose
100 ml 200 ml
Glycated hemoglobin
167 tests (1 test – 0.24 ml)
B 05.06* B 05.16*
New B 15.11*
New B 15.05* B 15.15*
20 x 2,5 ml R1: 1 x 12 ml, R2: 20 x 2,5 ml, Calibrator, Separators Glycated hemoglobin 40 x 2,5 ml R1: 1 x 24 ml, R2: 40 x 2,5 ml, Calibrator, Separators
B 15.13*
* � marked
Hemoglobin
2000 ml
R1: 2 x 100 ml
Reagent 1 – 12 months 12 months at 2...8 °С at 2...8° C Reagent 2 – 1 month at 2...8 °С Calibrator – until expiry date 24 months at 18..25° C
Until expiry date at 18...25 ºC
4,5 – 15%
50–300 g/L (5–30 g/dl)
«Vital Development Corporation» OJSC
6 back to CONTENTS
CLINICAL CHEMISTRY SUBSTRATES Ref
B 19.01*
Parameter
Kit size
Kit Composition
Product form
Method
Automation
Storage
Opened reagents stability
Measuring range
Enzymatic Colorimetric End point method (LODPAP)
Manual / Auto
12 months at 2...8° C
Reagent 1 – 6 months at 2...8 °С Calibrator – 3 months at 2...8 °С
0,6–13,3 mmol/L (5,0–120 mg/dl)
Lactate
5 x 10 ml
R1: 50 ml, R2: 5 vials, R3: 30 ml, Calibrator: 1 ml
Lyophilized
Lactate
50 ml
R1: 40 ml, R2: 10 ml, R3: 30 ml; Calibrator: 1 ml
Fluid
Enzymatic Colorimetric method, Fluid Stable
Manual / Auto
18 months at 2...8 C
Reagents - 1 month at 2...8 °С, Calibrator – 3 months at 2...8 °С
0,5–13,3 mmol/L
Fluid
Colorimetric Biuret method
Manual / Auto
18 months at 18...25° C
Reagent 1 – until expiry date at 18...25 °С Calibrator – 6 months at 2...8 °С
10–120 g/L (1–12 g/dl)
2 x 100 ml R1: 2 x 100 ml, Calibrator: 2 ml
Fluid
End point Colorimetric method in urine/CSF (with Pyrogallol Red)
Manual / Auto
18 months at 2...8° C
Reagent 1 – until expiry date at 2...8 °С Calibrator – 2 months at 2...8 °С
0,1–2,0 g/L (10–200 mg/dl)
Fluid
Enzymatic Colorimetric Phenol/Hypochlorite method
Manual
12 months at 2...8° C
Reagents 1, 3, 4 – until expiry date at 2...8 °С Calibrator – 1 month at 2...8 °С
2–32 mmol/L (12–200 mg/dl)
Lyophilized
Urease/GlDH Two point UV-method.
Semi-auto / Auto
18 months at 2...8° C
Reagent 1 – until expiry date at 2...8 °С Calibrator – 1 month at 2...8 °С
2–32 mmol/L (12–200 mg/dl)
New B 19.03
B 06.01*
Total protein
1000 ml
R1: 2 x 100 ml, Calibrator: 2 ml
B 06.03*
Total Protein
B 08.02*
Urea
100 tests
R1: 10 ml, Calibrator: 2 ml, R3: 100 ml, R4: 100 ml
B 08.03* B 08.13* B 08.23*
Urea
1 x 50 ml 2 x 50 ml 5 x 50 ml
R1: 1 x 50 ml, R2: 1 vial, Calibrator: 2 ml R1: 2 x 50 ml, R2: 2 vials, R3:2 ml R1: 1 x 250 ml, R2: 5 vials, Calibrator: 2 ml
B 08.04* B 08.14* B 08.24*
Urea
50 ml 100 ml 250 ml
R1: 40 ml, R2: 10 ml, Calibrator: 2 ml R1: 2 x 40 ml, R2: 2 x 10 ml, Calibrator: 2 ml R1: 1 x 250 ml, R2: 5 vials, Calibrator: 2 ml
Fluid
Urease/GlDH Two point UV-method.
Semi-auto / Auto
18 months at 2...8° C
Reagents – 6 months at 2...8 °С Calibrator – 1 month at 2...8 °С
2–32 mmol/L (12–200 mg/dl)
B 12.02*
Uric acid
2 x 50 ml
R1: 2 x 50 ml, R2: 2 vials, Calibrator: 1,5 ml
Lyophilized
Enzymatic Colorimetric method without deproteinization (Uricase/PAP)
Manual / Auto
18 months at 2...8° C
Calibrator – 1 month at 2...8 °С
80–1200 µmol/L (1,3–20 mg/dl)
Uric acid
100 ml 250 ml
Fluid
Enzymatic Colorimetric method without deproteinization (Uricase/PAP)
Manual / Auto
12 months Reagents - 2 months at 2...8 ºC 30 – 2400 µmol/L at 2...8 ºC Calibrator - 1 month at 2...8 ºC (0,5-40 mg/dL)
New B 12.03* B 12.13*
* � marked
R1: 2 x 40 ml; R2: 1 x 20 ml; Calibrator: 1 x 1,5 ml R1: 2 x 100 ml; R2: 1 x 50 ml; Calibrator: 1 x 1,5 ml
«Vital Development Corporation» OJSC
7 back to CONTENTS
CLINICAL CHEMISTRY ENZYMES Product form
Method
Automation
Storage
Opened reagents stability
Measuring range
R1: 48 ml, R2: 12 ml R1: 96 ml, R2: 24 ml R1: 200 ml, R2: 50 ml
Fluid
Enzymatic Kinetic Colorimetric EPS method (IFCC)
Semi-auto / Auto
36 months at 2...8 °С
Reagents - 90 days at 2...8° C
50–1320 U/L
R1: 40 ml, R2: 10 ml R1: 2 x 40 ml, R2: 2 x 10 ml
Fluid
Enzymatic Kinetic Colorimetric Immunoinhibition EPS method
Semi-auto / Auto
12 months at 2...8 °С
Reagents - 90 days at 2...8° C
15–600 U/L
Acid Phosphatase
250 total + 250 prostatic tests
R1:100 ml, R2: 100 ml, R3: 50 ml, Calibrator: 10 ml, R5: 100 ml
Fluid
End Point Colorimetric method, pNPP
Manual
12 months at 2...8° C
Until expiry date
up to 0,8 µKat/L
B 10.02
Acid Phosphatase
5 x 10 ml Total 5 x 10 ml Prostatic
R1: 50 ml, R2: 50 ml, R3: 10 vials
Lyophilized
Kinetic Colorimetric method (α-Naphtyl Phosphate)
Semi-auto / Auto
12 months at 2...8° C
Until expiry date
up to 74 U/L
B 09.02
Alkaline Phosphatase
200 tests
R1: 80 ml, R2: 100 ml, R3: 20 ml, Calibrator: 10 ml
Fluid
End point Colorimetric method (Bessey-LowryBrock), pNPP
Manual
18 months at 2...8°C
Reagents - until expiry date Calibrator-6 months at 18..25 °C
0,07–2,5 µKat/L
B 09.03* B 09.13*
Alkaline Phosphatase
250 ml 500 ml
R1: 200 ml, R2: 50 ml R1: 2 x 200 ml, R2: 2 x 50 ml
Fluid
Kinetic Colorimetric method (AMP-buffer, pNPP).
Semi-auto / Auto
12 months at 2...8 °С
Reagents - 3 months at 2...8° C
up to 680 U/L (30 °С), up to 830 U/L (37 °С)
ALT
50 ml 100 ml 500 ml
R1: 40 ml. R2: 10 ml R1: 80 ml, R2: 20 ml R1: 2 x 200 ml, R2: 100 ml
Fluid
Enzymatic Kinetic UV method, mono reagent, without pyridoxal phosphate, IFCC mod.
Semi-auto / Auto
12 months at 2...8 °С
Reagents - 30 days at 2...8° C
9–350 U/L
Ref
Parameter
Kit size
B 11.02* B 11.12* B 11.22*
α-Amylase
60 ml 120 ml 250 ml
B 11.05* B 11.15*
Pancreas б-Amylase
50 ml 100 ml
B 10.01
B 01.05* B 01.15* B 01.35*
* � marked
Kit Composition
«Vital Development Corporation» OJSC
8 back to CONTENTS
CLINICAL CHEMISTRY ENZYMES Ref
B 01.06* B 01.16*
B 01.04
Parameter
Kit size
ALT
1 x 50 ml 2 x 50 ml
Product form
Method
Automation
Storage
Opened reagents stability
Measuring range
R1: 1 x 50 ml, R2: 1 vial R1: 2 x 50 ml, R2: 2 vials
Lyophilized
Enzymatic Kinetic UV method, mono reagent, without pyridoxal phosphate, IFCC mod.
Semi-auto / Auto
12 months at 2...8 °С
Reconstituted reagents stability – 30 days at 2...8° C
9–350 U/L
Lyophilized
Enzymatic Kinetic UV method, start, without pyridoxal phosphate, IFCC
Semi-auto / Auto
12 months at 2...8°С
Reagent 3 – 3 months at 2...8° C
10–190 U/L
Manual
18 months at 18...25 °С
Reagent 1 – 18 months at 2...8 °С Reagent 2 & 4 – 18 months at 18...25° C
0,067–1,25 mkat/L
Kit Composition
ALT
1 x 50 ml
R1: 1 x 50 ml, R2: 1 vial, R3: 1 x 5 ml
B 01.01 B 01.11
ALT
400 tests 1000 tests
R1: 100 ml, R2: 100 ml, Calibrator: 5 ml, R4: 100 ml R1: 250 ml, R2: 250 ml, Calibrator: 5 ml, R4: 250 ml
Fluid
End point Colorimetric method (ReitmanFrankel)
B 00.102
ALT/AST
200 + 200 tests
R1: 50 ml ALT + 50 ml AST, R2: 100 ml, R4: 100 ml, Calibrator: 5 ml
Fluid
End point Colorimetric method (ReitmanFrankel)
Manual
18 months at 18...25° C
Reagent 1–12 months at 2...8 °С Reagent 2 & 4 – 12 months at 18...25° C
0,067–1,25 mkat/L
AST
50 ml 100 ml 500 ml
Fluid
Enzymatic Kinetic UV method, without pyridoxal phosphate, IFCC mod.
Semi-auto / Auto
12 months at 2...8 °С
Reagents 1 & 2 30 days at 2...8° C
5–500 U/L
AST
1 x 50 ml 2 x 50 ml
R1: 1 x 50 ml, R2: 1 vial R1: 2 x 50 ml, R2: 2 vials
Lyophilized
Enzymatic Kinetic UV method, mono reagent, without pyridoxal phosphate, IFCC mod.
Semi-auto / Auto
12 months at 2...8 °С
Reconstituted reagents stability – 30 days at 2...8° C
5–400 U/L
R1: 1 x 50 ml, R2: 1 vial, R3: 1 x 5 ml
Lyophilized
Enzymatic Kinetic UV method, start, without pyridoxal phosphate, IFCC
Semi-auto / Auto
12 months at 2...8 °С
Reagent 3 – 30 days at 2...8° C
10–190 U/L
B 02.05* B 02.15* B 02.35*
B 02.06* B 02.16*
B 02.04
* � marked
AST
1 x 50 ml
R1: 40 ml. R2: 10 ml R1: 80 ml, R2: 20 ml R1: 2 x 200 ml, R2: 100 ml
«Vital Development Corporation» OJSC
9 back to CONTENTS
CLINICAL CHEMISTRY ENZYMES Automation
Storage
Opened reagents stability
Measuring range
Fluid
End point Colorimetric method (ReitmanFrankel)
Manual
18 months at 18...25 °С
Reagent 1 – 18 months at 2...8 °С Reagents 2 & 4 – 18 months at 18...25° C
0,067–1,25 mkat/L
R1: 50 ml, R2: 5 vials R1: 2 x 50 ml, R2: 10 vials
Lyophilized
Optimized (DGKC, IFCC) Kinetic UV-method
Semi-auto / Auto
12 months at 2...8 °С
Reagent 1 – until expiry date at 2...8° C
25–1040 U/L
R1: 40 ml, R2: 10 ml R1: 2 x 40 ml, R2: 2 x 10 ml or R1: 80 ml, R2: 20 ml
Liquid
Optimized (DGKC, IFCC) Kinetic UV-method
Semi-auto / Auto
12 months at 2...8 °С
Reagents – 1 month at 2...8° C
20–1040 U/L
5 x 10 ml 10 x 10 ml
R1: 50 ml, R2: 5 vials R1: 2 x 50 ml, R2: 10 vials
Lyophilized
High-sensitive Immunoinhibition Kinetic UV-method
Semi-auto / Auto
12 months at 2...8 °С
Reagent 1 – until expiry date at 2...8° C
5–650 U/L
CK-MB
5 x 10 ml 10 x 10 ml
R1: 50 ml, R2: 5 vials R1: 2 x 50 ml, R2: 10 vials
Lyophilized
Immunoinhibition Kinetic UV-method
Semi-auto / Auto
12 months at 2...8° C
Reagent 1 – until expiry date at 2...8° C
10–650 U/L
B 07.04*
γ-GT
50 ml
R1: 40 ml, R2: 10 ml
Fluid
Kinetic Colorimetric method, (GlupA-carboxy), stand. Szasz
Semi-auto / Auto
24 months at 2...8 °С
Reagents 1 & 2 – 3 months at 2...8° C
up to 230 U/L
B 23.01*
LDH
5 x 10 ml
R1: 50 ml, R2: 5 vials
Lyophilized
Optimized (DGKC) Kinetic UV-method (P→L)
Semi-auto / Auto
18 months at 2...8 °С
Reagent 1 – until expiry date at 2...8° C
100–1200 U/L
B 23.02* B 23.12*
LDH
50 ml 100 ml
Fluid
Optimized (DGKC) Kinetic UV-method (P→L)
Semi-auto / Auto
12 months at 2...8° C
30 days at 2...8° C
100–1200 U/L
Ref
Parameter
Kit size
B 02.01 B 02.11
AST
400 tests 1000 tests
R1: 100 ml, R2: 100 ml, Calibrator: 5 ml, R4: 100 ml R1: 250 ml, R2: 250 ml, Calibrator: 5 ml, R4: 250 ml
B 28.03* B 28.13*
CK
5 x 10 ml 10 x 10 ml
CK
50 ml 100 ml
B 29.03* B 29.13*
CK-MB
B 29.04* B 29.14*
New B 28.04* B 28.14*
* � marked
Kit Composition
R1: 40 ml, R2: 10 ml R1: 2 x 40 ml, R2: 2 x 10 ml
Product form
Method
«Vital Development Corporation» OJSC
10 back to CONTENTS
CLINICAL CHEMISTRY ELECTROLYTES Ref
Method
Automation
Storage
Opened reagents stability
Measuring range
Parameter
Kit size
Calcium
200 ml
R1: 100 ml, R2: 100 ml, Calibrator: 2 ml
Fluid
Colorimetric method (Phtalein Purple).
Manual / Auto
24 month Calibrator – 3 months at 18..25 °С at 18...25° C
B 18.02* B 18.12*
Calcium
100 ml 200 ml
R1: 100 ml, Calibrator: 2 ml R1: 2 x 100 ml, Calibrator: 2 x 2 ml
Fluid
Colorimetric method (Arsenazo III)
Manual / Auto
12 months at 2...25 ºC
Calibrator - 3 months at 18...25 ºC
B 14.01*
Chloride
Fluid
Colorimetric method (Mercurothyocyanate)
Manual / Auto
24 months at 18...25° C
Reagent 1 – until expiry date at 18...25 °С 75–120 mmol/L Calibrator – 2 months at 18...25 °С
B 20.01*
Copper
Fluid
Colorimetric method (3,5-Dibromo-PAESA)
Manual / Auto
12 month at 18...25° C
Until expiry date
2,04–78,65 µmol/L (13–500 µg/dl)
Fluid
Colorimetric mono reagent method (nitroPAPS), without deproteinization
Manual / Auto
18 month at 18...25° C
Reagents and Calibrator – 1 month at 2...8 °С
8–179 µmol/L (up to 1000 mg/ dl)
Manual
18 month at 18...25° C
Reagents - until expiry date Calibrator – 1 month at 18...25 °С
8–179 µmol/L (up to 1000 mg/ dl)
Calibrator – 3 months at 2...8 °С
0,2–2,0 mmol/L (0,4–4,0 mEq/L)
B 18.01*
Kit Composition
Product form
0,25–3,75 mmol/L (1–15 mg/dl)
New
B 24.01* B 24.11* B 24.31*
2 x 100 ml R1: 2 x 100 ml, Calibrator: 1,5 ml
50 ml
R1: 50 ml, Calibrator: 1 ml
0,6-6,5 mmol/L (2,4-26 mg/dL)
Iron
50 ml R1: 48 ml, R2: 1 x 2,8 ml, Calibrator: 0,5 ml 2 x 50 ml R1: 96 ml, R2: 1 x 5,6 ml, Calibrator: 1,0 ml 2 x 100 ml R1: 2 x 95 ml, R2: 2 x 5 ml, Calibrator: 2,0 ml
B 24.03 B 24.13 B 24.33
Iron
50 ml R1: 25 ml, R2: 25 ml, Calibrator: 1,0 ml 2 x 50 ml R1: 50 ml, R2: 50 ml, Calibrator: 1,5 ml 2 x 100 ml R1: 100 ml, R2: 100 ml, Calibrator: 2 x 1,5 ml
Fluid
Colorimetric double reagent method (nitroPAPS), without deproteinization
B 25.01* B 25.11*
Magnesium
50 ml 2 x 50 ml
R1: 50 ml, Calibrator: 0,5 ml R1: 2 x 50 ml, Calibrator: 1 ml
Fluid
Colorimetric (Xylidyl Blue) method without deproteinization.
Manual
18 months at 18...25° C
B 16.01*
Phosphorus
2 x 100 ml R1: 2 x 100 ml, R2: 4,5 ml, Calibrator: 1,5 ml
Fluid
Phosphomolybdate UVmethod
Manual / Auto
24 months Reagents – 6 months at 18...25 °С 0,5–6,46 mmol/L at 18...25° C Calibrator – 3 months at 18...25 °С (1,5–20 mg/dl)
* � marked
«Vital Development Corporation» OJSC
11 back to CONTENTS
CLINICAL CHEMISTRY ELECTROLYTES Ref
Parameter
Kit size
Kit Composition
B 26.01* B 26.11*
Potassium
50 ml 2 x 50 ml
R1: 1 x 50 ml, Calibrator: 1 ml R1: 2 x 50 ml, Calibrator: 2 x 1 ml
Sodium
2 x 10 ml 4 x 10 ml
R1: 21 ml, R2: 1,05 ml, R3: 2 vials, Calibrator: 1,5 ml, R5: 115 ml R1: 41 ml, R2: 2,1 ml, R3: 4 vials, Calibrator: 1,5 ml, R5: 230 ml
B 27.102 B 27.02
B 27.103* B 27.03*
Sodium
2 x 10 ml 4 x 10 ml
Product form
Method
Automation
Storage
Opened reagents stability
Measuring range
Fluid
Turbidimetric method(sodium tetraphenylborate)
Manual / Auto
18 months at 18...25° C
Calibrator – 1 month at 18...25° C
2–10 mmol/L
Lyophilized
Enzymatic Colorimetric Two point / End point method
Manual / Semi-auto
12 months at 2...8° C
Reagent 1 & 2 – 1 month at 2..8° C Reagent 5 – until expiry date 90–160 mmol/L at 2...25 ° C Calibrator – 1 month at 2...8° C
12 months at 2...8° C
Reagent 1 – 1 month at 2..8 °С Reagent 2 on instrument board – 7 days, used manually – 1 month at 2...8 °С Calibrator –1 month at 2...8° C
90–160 mmol/L
90–160 mmol/L
R1: 21 ml, R2: 4,1 ml, R3: 2 vials, Calibrator: 1,5 ml LyophiR1: 41 ml, R2: 4,1 ml, R3: 4 vials, Calibrator: 1,5 ml lized
Enzymatic Colorimetric Two point method
Semi-auto / Auto
Fluid
Enzymatic Colorimetric Two point method
Semi-auto / Auto
12 months at 2...8° C
Reagent 1 & 3 – 1 month at 2...8 °С Reagent 2 on instrument board – 7 days, used manually – 1 month at 2...8 °С Calibrator – 1 month at 2...8° C
R1: 5 ml, R2: 8 g; Spatula
Powder
Saturation with Iron, Magnesium carbonate precipitation
Manual
18 months at 18...25° C
Until expiry date
depends on type of used Iron kit
R1: 50 ml, Calibrator: 1 ml
Fluid
Colorimetric method (5-Bromo-PAPS)
Manual / Auto
12 months at 18...25° C
Until expiry date
up to 61,2 µmol/L (400 µg/dl)
New Sodium
30 ml 55 ml
B 24.02
TIBC
400 tests
B 22.01*
Zinc
50 ml
B 27.104* B 27.04*
* � marked
R1: 23 ml, R2: 5 ml, R3: 2,5 ml, Calibrator: 1,5 ml R1: 45 ml, R2: 5 ml, R3: 5 ml, Calibrator: 1,5 ml
«Vital Development Corporation» OJSC
12 back to CONTENTS
CLINICAL CHEMISTRY CALIBRATORS Name
Volume
Product form
Parameters
Storage
Opened/ reconstituted calibrators stability
APO A1/B Calibrator High
1 ml
Lyophilized
APO A1, APO A2, APO B
Until expiry date at 2...8 °С
6 weeks at 2...8 °С
B 46.51c B 46.53c
ASL-O Calibrator High
1 ml 3 x 1 ml
Fluid
Anti-Streptolysin (O)
Until expiry date at 2...8 °С
6 weeks at 2...8 °С
B 40.51c B 40.53c
CRP Calibrator High
1 ml 3 x 1 ml
Fluid
C- reactive protein
Until expiry date at 2...8 °С
6 weeks at 2...8 °С
B 15.41c
Glycated Hemoglobin Calibrator
4 x 0,5 ml
Lyophilized
HbA1hemoglobin
Until expiry date at 2...8 °С
1 month at 2...8 °С
B 13.55c
HDL-Cholesterol Calibrator
3 ml
Lyophilized
HDL-Cholesterol
Until expiry date at 2...8 °С
7 days at 2...8 °С
B 13.56c
LDL-Cholesterol Calibrator
1 ml
Lyophilized
LDL-Cholesterol
Until expiry date at 2...8 °С
7 days at 2...8 °С
B 41.51c B 41.53c B 41.54c
Microalbumin Calibrator High
1 ml 3 x 1 ml 10 x 1 ml
Fluid
Microalbumin
Until expiry date at 2...8 °С
6 weeks at 2...8 °С
Lyophilized
ACP, ACP-P, ALP, ALT, AST, AMY, PAMY, CK, γ-GT, LDH, Calcium, Magnesium, Phosphorus, Cholesterol, Triglycerides, Albumin, Bilirubin total, Bilirubin direct, Creatinine, Glucose, Lactate, Total protein, Urea, Uric acid
Until expiry date at 2...8 °С
12 hours at 15…25 °C 5 days at 2…8 °C 4 weeks at -25 °C to -15 °C (when frozen once)
Until expiry date at 2...8 °С
6 weeks at 2...8 °С
Until expiry date at 2...8 °С
4 weeks at 2...8 °С
Ref
B APO.51c
B 33.01
B PS.51c B PS.53c
Multicalibrator Vital
1 x 3 ml
PS-Calibrator (Protein Standard)
1 ml 3 x 1 ml
Fluid
Albumin, a1-Antitrypsin, a2-Macroglobulin, a1-Acidglycoprotein, Ceruloplasmin, Haptoglobin, Transferrin, Ig A, Ig G, Ig M, Complement С3, Complement С4, Antithrombin III, C1 Esterase Inhibitor, Kappa Light Chain, Lambda Light Chain, Prealbumin
RF Calibrator
3 x 1 ml
Fluid
RF (level 1, level 2, level 3)
New B 52.53c
* � marked
«Vital Development Corporation» OJSC
13 back to CONTENTS
CLINICAL CHEMISTRY Control materials Name
Volume
Product form
Parameters
Storage
Opened/ reconstituted controls stability
APO A1/B Control
1 ml
Fluid
APO A1, APO A2, APO B
Until expiry date at 2...8 °С
6 weeks at 2...8 °С
B 46.41k B 46.43k
ASL-O Control
1 ml 3 x 1 ml
Fluid
Anti-Streptolysin (O)
Until expiry date at 2...8 °С
6 weeks at 2...8 °С
B 40.41KB B 40.43KB
CRP Control High
1 ml 3 x 1 ml
Fluid
C- reactive protein
Until expiry date at 2...8 °С
6 weeks at 2...8 °С
B 40.42KH B 40.44KH
CRP Control Low
1 ml 3 x 1 ml
Fluid
C- reactive protein
Until expiry date at 2...8 °С
6 weeks at 2...8 °С
B 15.21k
Glycated Hemoglobin Control
2 x 0,5 ml
Lyophilized
HbA1c hemoglobin
Until expiry date at 2...8 °С
1 month at 2...8 °С
Lyophilized
CK, GT, LDH, Calcium, Chloride, Iron, Magnesium, Phosphorus, Potassium, Sodium, Zinc, Cholesterol, Triglycerides, APO A1, APO B, HDL-C, LDL-C, Albumin, Bilirubin total, Bilirubin direct, Creatinine, Glucose, Lactate, Total protein, Urea, Uric acid, IgA, IgM, IgG
Until expiry date at 2...8 °С
12 hours at 15…25 °C 5 days at 2…8 °C 4 weeks at -25 °C to -15 °C (when frozen once)
Until expiry date at 2...8 °С
12 hours at 15…25 °C 5 days at 2…8 °C 4 weeks at -25 °C to -15 °C (when frozen once)
Ref B APO.41k
B 34.01
Lipocont Vital, level 1
1 x 5 ml
B 35.01
Lipocont Vital, level 2
1 x 5 ml
Lyophilized
CK, GT, LDH, Calcium, Chloride, Iron, Magnesium, Phosphorus, Potassium, Sodium, Zinc, Cholesterol, Triglycerides, APO A1, APO B, HDL-C, LDL-C, Albumin, Bilirubin total, Bilirubin direct, Creatinine, Glucose, Lactate, Total protein, Urea, Uric acid, IgA, IgM, IgG
B 41.41k B 41.43k
Microalbumin Control
1ml 3 x 1 ml
Fluid
Microalbumin
Until expiry date at 2...8 °С
6 weeks at 2...8 °С
B 31.01 B 31.11
Multicont Vital, normal level (human control serum) lyophilized
5 ml 8 x 5 ml
Lyophilized
ACP, ALP, ALT, AST, AMY, PAMY, CK, GT, IgA, IgG, IgM, LDH, Calcium, Chloride, Iron, TIBC, Magnesium, Phosphorus, Potassium, Sodium, Cholesterol, Triglycerides, Albumin, Bilirubin total, Bilirubin direct, Creatinine, Glucose, Lactate, Total protein, Transferrin, Urea, Uric acid.
Until expiry date at 2...8 °С
6 weeks at 2...8 °С
B 32.01 B 32.11
Multicont Vital, patological level (human control serum) lyophilized
5 ml 8 x 5 ml
Lyophilized
ACP, ALP, ALT, AST, AMY, PAMY, CK, GT, LDH, Calcium, Chloride, Iron, Magnesium, Phosphorus, Potassium, Sodium, Cholesterol, Triglycerides, Albumin, Bilirubin total, Bilirubin direct, Creatinine, Glucose, Lactate, Total protein, Urea, Uric acid.
Until expiry date at 2...8 °С
1 month at 2 ...8 °С
Protein Control
1 ml 3 x 1 ml
Fluid
Albumin, a1-Antitrypsin, a2-Macroglobulin, a1-Acidglycoprotein, Ceruloplasmin, Haptoglobin, Transferrin, Ig A, Ig G, Ig M, Complement С3, Complement С4, Antithrombin III, C1 Esterase Inhibitor, Kappa Light Chain, Lambda Light Chain, Prealbumin, RF
Until expiry date at 2...8 °С
6 weeks at 2...8 °С
B PC.41k B PC.43k
* � marked
«Vital Development Corporation» OJSC
14
New
back to CONTENTS
ELISA
Thyroid diagnOstics ELISA kits Ref
Name
Number of tests
Method
Principle
Sensitivity
Detection range
Storage
TSH-IMAXYZ
96
Enzyme Linked Immunosorbent Assay
Sandwich ELISA principle
0,015 μIU/ml
0,015 – 15 μIU/ml
18 months at +2...8 °С
FT4- IMAXYZ
96
Enzyme Linked Immunosorbent Assay
Competitive ELISA principle
1 pmol/l
1 – 90 pmol/l
18 months at +2...8 °С
T3-IMAXYZ
96
Enzyme Linked Immunosorbent Assay
Competitive ELISA principle
0,2 ng/ml
0,2 – 8 ng/ml
18 months at +2...8 °С
T4-IMAXYZ
96
Enzyme Linked Immunosorbent Assay
Competitive ELISA principle
10 nmol/l
10 – 320 nmol/l
18 months at +2...8 °С
FT3-IMAXYZ
96
Enzyme Linked Immunosorbent Assay
Competitive ELISA principle
0,5 pg/ml
0,5 – 30 pg/ml
18 months at +2...8 °С
abTG-IMAXYZ
96
Enzyme Linked Immunosorbent Assay
Indirect ELISA principle
4 IU/ml
4 – 1500 IU/ml
18 months at +2...8 °С
abTPO-IMAXYZ
96
Enzyme Linked Immunosorbent Assay
Indirect ELISA principle
1,5 IU/ml
1,5 – 500 IU/ml
18 months at +2...8 °С
TG-IMAXYZ
96
Enzyme Linked Immunosorbent Assay
Sandwich ELISA principle
0,5 ng/ml
0,5 – 300 ng/ml
18 months at +2...8 °С
New BT11-01*
New BT11-02*
New BT11-03*
New BT11-04*
New BT11-05*
New BT11-06*
New BT11-07*
New BT11-08*
* � marked
«Vital Development Corporation» OJSC
15
New
back to CONTENTS
ELISA
Tumor markers ELISA kits Ref
Name
Number of tests
Method
Principle
Sensitivity
Detection range
Storage
PSA
96
Enzyme Linked Immunosorbent Assay
Sandwich ELISA principle
0,1 ng/ml
0,1 – 40 ng/ml
18 months at +2...8 °С
Free PSA
96
Enzyme Linked Immunosorbent Assay
Sandwich ELISA principle
0,06 ng/ml
0,06 – 12 ng/ml
18 months at +2...8 °С
CA 125
96
Enzyme Linked Immunosorbent Assay
Sandwich ELISA principle
1,6 U/ml
1,6 – 1000 U/ml
18 months at +2...8 °С
New BT 12-09
New BT 12-10
New BT 12-11
* � marked
«Vital Development Corporation» OJSC
16
New
back to CONTENTS
LATEX SLIDE TESTS latex SLIDE TESTS
Ref
Name
Number of tests
ASL-O
125 tests 250 tests
CRP
60 tests 125 tests 250 tests
RF
125 tests 250 tests
Kit Composition
Storage
Sensivity
R1: 1 x 2,5 ml; R2: 5 ml; Positive control (+): 1 x 0,5 ml; Negative control (-): 1 x 0,5 ml; Test cards: 3 R1: 2 x 2,5 ml; R2: 5 ml; Positive control (+): 1 x 0,5 ml; Negative control (-): 1 x 0,5 ml; Test cards: 5
Until expiry date at 2...8° C
200±50 IU/ml
R1: 1 x 1,3 ml; R2: 5 ml; Positive control (+): 1 x 0,5 ml; Negative control (-): 1 x 0,5 ml; Test cards: 3 R1: 1 x 2,5 ml; R2: 5 ml; Positive control (+): 1 x 0,5 ml; Negative control (-): 1 x 0,5 ml; Test cards: 3 R1: 2 x 2,5 ml; R2: 5 ml; Positive control (+): 1 x 0,5 ml; Negative control (-): 1 x 0,5 ml; Test cards: 5
Until expiry date at 2...8° C
6 mg/l (5-10 mg/l)
“R1: 1 x 2,5 ml; R2: 5 ml; Positive control (+): 1 x 0,5 ml; Negative control (-): 1 x 0,5 ml; Test cards: 3 R1: 2 x 2,5 ml; R2: 5 ml; Positive control (+): 1 x 0,5 ml; Negative control (-): 1 x 0,5 ml; Test cards: 5
Until expiry date at 2...8° C
8 IU/ml (6-16 IU/ml)
New B 200.125 B 200.250
New B 201.060 B 201.125 B 201.250
New B 202.125 B 202.250
* � marked
«Vital Development Corporation» OJSC
17
New
back to CONTENTS
EQUIPMENT
Water Purification System “PRODEION 10 VS”
Intended use PRODEION 10 VS is an Intelligent Water Purification System designed specially for medical laboratories’ application. Technical characteristics Voltage
220 V
Power consumption
≤ 100 watt
Flowrates
15—20 L/h
Water resistivity Feedwater pressure Storage tank Operational life Dimensions Weight
Filter
Effect
Mechanical
mechanical suspensions organic suspensions turbidity sediment rust
Carbon
water dechlorination hydrogen sulfide elimination permanganate value lowering colour reduction
up to 18 МΩ • cm (0.055 μS/cm) 0—7 Bar 10 L 4000 L
elimination
Cation exchange water softening softener
1050 x 400 x 360 mm 20 kg
• Built-in conductometer with temperature compensation. • Displaying of water resistivity, water pressure, temperature in real-time mode. • Automatic controller of system operational capacity. • Automatic electronic pressure sensor. • Automatic water recirculation and system ablution. • Automatic stop when the storage tank is full. • Direct connection to the water supply system. • Independent of water pressure. • Compact transportable body. • LCD. • Multilanguage interface. * � marked
Filtration
RO Membrane
Mg2+ Hg2+ Sr2+ Ar3+, Ar5+ Fe2+, Fe3+ Pb4+ Cl –
Mg6[Si4O10](OH)8 CN – NO3– NO2– SO42– bacteria viruses
elimination
all organic elements up to 98% of non-organic elements Ion exchange resin №1
Pre-purification
Ion exchange resin №2
Deionazation
Complies with: ISO 3696 (1987) ASTM (D 1193-91) NCCLS (1988) «Vital Development Corporation» OJSC
18
New
back to CONTENTS
EQUIPMENT
Water Purification System “PRODEION 20 VS”
Intended use PRODEION 20 VS is an Intelligent Water Purification System convenient for medical laboratories for medium levels of pure water requirements. Technical characteristics Voltage
220 V
Power consumption
≤ 100 watt
Flowrates
30—40 L/h
Water resistivity Feedwater pressure Storage tank Operational life Dimensions Weight
up to 18 МΩ • cm (0.055 μS/cm)
•
0—7 Bar 20 L
Direct water feed. “PRODEION” 20 VS may be directly connected to the laboratory analyser providing pressure feed of the purified water from the water tank of the System directly to the analyser.
4000 L 1050 x 400 x 360 mm 35 kg
• Built-in conductometer with temperature compensation. • Displaying of water resistivity, water pressure, temperature in real-time mode. • Automatic controller of system operational capacity. • Automatic electronic pressure sensor. • Automatic water recirculation and system ablution. • Automatic stop when the storage tank is full.
* � marked
The system may be equipped with additional options.
• • • • •
Direct connection to the water supply system. Independent of water pressure. Compact transportable body. LCD. Multilanguage interface. Complies with: ISO 3696 (1987) ASTM (D 1193-91) NCCLS (1988)
«Vital Development Corporation» OJSC
19
New
back to CONTENTS
EQUIPMENT
Water Purification System “PRODEION 40 VS”
Intended use PRODEION 40 VS is an Intelligent Water Purification System convenient for medical laboratories for medium levels of pure water requirements. Technical characteristics Voltage
220 V
Power consumption
≤ 100 watt
Flowrates
40—50 L/h
Water resistivity Feedwater pressure Storage tank Operational life Dimensions Weight
up to 18 МΩ • cm (0.055 μS/cm)
•
0—7 Bar 40 L
Direct water feed. “PRODEION” 40 VS may be directly connected to the laboratory analyser providing pressure feed of the purified water from the water tank of the System directly to the analyser.
4000 L 1050 x 400 x 360 mm 40 kg
• Built-in conductometer with temperature compensation. • Displaying of water resistivity, water pressure, temperature in real-time mode. • Automatic controller of system operational capacity. • Automatic electronic pressure sensor. • Automatic water recirculation and system ablution. • Automatic stop when the storage tank is full.
* � marked
The system may be equipped with additional options.
• • • • •
Direct connection to the water supply system. Independent of water pressure. Compact transportable body. LCD. Multilanguage interface. Complies with: ISO 3696 (1987) ASTM (D 1193-91) NCCLS (1988)
«Vital Development Corporation» OJSC