ATmega 328 datalogger Altimeter “Alti Multi”– kit console software user manual Goal The goal of this document is to explain how to use the datalogger altimeter kit (AltiMulti) that you just built with the altimeter console software. This is for Firmware version 1.4 and greater. The document assumes that you have already installed altimeters in a rocket payload bay. Before your start Remember that it is a kit and that you can modify the program and behaviour of your altimeter. The country where you live might not even allow the use of such device. You have to assume total legal responsibility for any damages or claims including personal injury that results from the use of this device. I shall not be responsible for the above. If you disagree with that, please do not build it or use it.
Related documentation This document assumes that you have successfully built the Alti Multi kit altimeter and that you have read the kit building instructions. This will not cover things such as flashing the altimeter which will be discussed in another document.
ATmega 328 datalogger Altimeter “Alti Multi”– kit console software user manual Console overview The altimeter console has been written in Java so that it can run on multiple platforms.
Select the USB port speed which has to be the same has the altimeter speed (9600)
Select flight
This is the message window
The console mainly does 3 things: - Retrieve flight data - Configure the altimeter - Allow altimeter firmware upgrade without the need of a development environment
ATmega 328 datalogger Altimeter “Alti Multi”– kit console software user manual Quick start Start the software on your computer and plug the altimeter to the computer using the USB cable.
The altimeter should be beeping away doing its continuity test. A beeping altimeter does not mean an established communication. You need to choose the correct USB port and speed before you can connect to the altimeter.
Important notes: If you use the USB cable you should never power the altimeter with a battery. However if you use the Bluetooth module to allow wireless data retrieval or altimeter config then you need to use a battery. What you should not do: - Never press the altimeter reset switch with pyro charges connected, this will do an ignition test and fire them. - Never attempt to flash an altimeter with pyro charges connected it will fire them - Never connect pyro charges or fly it without testing the altimeter on the ground. You should use Xmas bulbs to test the altimeter in a chamber after you have flashed it.
ATmega 328 datalogger Altimeter “Alti Multi”– kit console software user manual Application preferences The Altimeter console application can be configured
This will open the screen below
Application language: by default the locale language will be used if it exists. If it doesn’t then it will use English unless you overwrite it with another language. Units: you can choose between feet or meters. Internally the altimeter is working in meters. Default COM speed: you can choose a default speed so that whenever you restart the app it will default to it. Avrdude path and config path: those are used to locate the avrdude program which is used to flash the firmware. You can change the path by clicking the ellipse (
ATmega 328 datalogger Altimeter “Alti Multi”– kit console software user manual Retrieving the altimeter flight When you click on the retrieve flight button or retrieve the altimeter config from the menu the altimeter will establish communication (providing that the correct com port and speed have been chosen).
Saving the flight: The current flight can be exported and saved to a CSV file (coma separated file).
CSV files can then be imported on a database or an Excel file.
ATmega 328 datalogger Altimeter “Alti Multi”– kit console software user manual Changing the altimeter configuration As of version 1.4 of the altimeter firmware, the entire altimeter config can be soft coded and stored in the EEPROM; you no longer need to use the jumper. First you need to retrieve the current altimeter configuration. This can be done from the menu [Altimeter Config]-> [Retrieve Alti config]
Note that if the selected port is not connected to the altimeter it will timeout. If successful you will have the following window:
This retrieves for information the altimeter name and version (in the future it will be able to connect to different altimeter with some sort of plug-in mechanism). Altitude beeping mode: you can choose between 2 different modes. Mode 1 is: 1 long beep per hundred meter or feet and 1 short beep per meter or feet Mode 2 is: will beep each digit after the other Beeping frequency: you can choose your beeping frequency between 200hz and 1khz, this is for people who can not hear properly the default frequency and also in case you have several altimeter in your payload you might want them to beep differently so that you can identify them. Altitude units: this is used when beeping the altitude after the flight; it will beep it in meters or feet. 11/11/2013
ATmega 328 datalogger Altimeter “Alti Multi”– kit console software user manual Main altitude: this is the deployment altitude for the main parachute. Note that it will use meter or feet depending on what units you have selected. Channel 1 to 3: here you can define the function of each pyro output Channel 1 to 3 delays: here you can define for each pyro output a delay in ms. This is useful when you have 2 altimeters and want to avoid both to fire exactly at the same time. Modify the configuration and if you want to save it then send it back to the altimeter by clicking the [Upload config] button. Supersonic mode: do not take into account the measure during the first seconds of the flight. This is to avoid premature ejection because the measures are not relevant at that speed.
ATmega 328 datalogger Altimeter “Alti Multi”– kit console software user manual Upgrading the altimeter If you do not know any C programming or do not want to use the Arduino development environment you can upgrade your altimeter firmware using the console. From the menu [altimeter config]-> [upload firmware]
Then select the firmware (hex file) that you want to upload
Press the altimeter reset button and click on open just after that. The program then upload, make sure you check the message window for errors or success.
ATmega 328 datalogger Altimeter “Alti Multi”– kit console software user manual Wireless communication Because you do not want to remove the altimeter from your rocket after each flight, replacing the USB cable with a wireless module will allow you to retrieve flight data from the rocket without opening the payload.
Compatibility table The following table is a summary of all the version history Front end type Arduino serial monitor Arduino serial monitor or Altimeter console Arduino serial monitor or Altimeter console
Java Front end version ( Altimeter console) Some will work with 0.5 0.8
Altimeter program > 1.3 1.4
0.9
1.5
Trouble shooting guide This section will be completed to help people identifying problemes with their altimeter. Flight data retrieval is always timing out what should I do? - Make sure that you have selected the correct USB port and the correct speed FAQ Q: How can I identify which altimeter version I have? A: When the altimeter is powered on it will beep its version. The long beep are for the major version and the short beep are for the minor version. For example, version 1.3 will be one long beep and 3 short beeps. Q: Why is the altimeter beeping away when I power it on? A: This is the continuity test. It does it to test the continuity on all the output. One short beep mean the charge is ok and a long beep mean the charge is not ok. Check the connection on the altimeter or if the ematch on the charge is ok.
High power. No yes yes yes. Category. Construction technic. Ground Support. Electronic. Other .... pad because it takes time to get back on the ground. ... Note that the altimeter will keep on beeping the altitude of the apogee and main until it is.
May 14, 2013 - Electronic. Other .... component used, you just need to plug them and solder them. ... Before you get started here are some recommendations.
May 13, 2013 - ATtiny 84 dual Altimeter âMini Alti Duoââ kit assembly instructions .... Do not hesitate to clean up frequently your soldering iron in order to do ...
La Console de Gree, le plus grand fabricant de climatisation au ... La technologie Gree offre des performances élevées avec un .... Net / Brut (kg). 15.5 / 18.5.
May 17, 2007 - reserve parachute closing loop that is properly pulled through the ...... When the device is unlocked, the control unit display shows a colon â:â.
have a number of mic channels, the display can be controlled from two Relays built-in in ... All mono modules are fitted with a high pass filter with variable frequency. ..... As described at the § 7.16, the START switch operates in tandem with the.
Ideally a cool area is preferred not in close proximity to power distribution ... Each Oxygen 7 module allows also to control two relays controlling ON-AIR lamps. ..... Each press of the START button will alternately send Start and Stop ..... Pins 8
пÑоÑеÑÑ. RU. This device complies with Industry Canada License-exempt RSS-210. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interf
PFL RESET key will always disable all the active PFL keys, regardless of ..... replace whatever signals are also present on the HP output. Example 2 ..... power fuse and a spare, both of the same value, rated at 1600 mA T for. 220/230 V AC ...
Please use high quality wires with good electric shield and balanced links wherever possible. ... TECHNOLOGY and the connection to an auxiliary signal .... reproduce Master signal till a PFL will be called by one or more input modules. .... through a
15 inch â long used in many applications since its introduction in the legendary X-60D. The Highlight IIA includes 10½ inches of standard rack space below the ...
Écran LCD 19 pouces repliable prend en charge 1 366 x 768 résolution. Permet un contrôle ... Profondeur d'image : 0,264 (H) x 0,264 (V). • Résolution : 1 280 x ...