direction as the arrow cast on the valve body. INSTALLATION. 1. Mount the valve. See Fig. 1 and 2. 2. Connect the control air tubing. NOTE: No calibration or adjustments are ... Golden Valley, MN 55422. Scarborough, Ontario. M1V 4Z9. Printed in U.S.A. on recycled paper containing at least 10% customer.honeywell.com.
VP527A Pneumatic Water Valve INSTALLATION INSTRUCTIONS
BEFORE INSTALLATION Allow sufficient room for servicing or removing the valve. See Fig. 1 for space requirements. This valve can be installed in any position. The direction of the flow should be in the same direction as the arrow cast on the valve body.
AIR CONNECTION FOR 1/4 IN. (6 MM) O.D. PLASTIC TUBING
1-1/2 (38)
INSTALLATION 1. 2.
1
2-1/4 (57) DIA.
3-13/16 (97)
Mount the valve. See Fig. 1 and 2. Connect the control air tubing.
1-5/8 (41)
NOTE: No calibration or adjustments are necessary.
1-3/8 (35) 2
3-1/8 (79)
2
1/2 IN. (12MM) X 45° SAE FLARED TUBE CONNECTION - 2 (NOT FURNISHED) 1
ALLOW 1-1/2 IN. (38 MM) MINIMUM CLEARANCE TO SERVICE VALVE,
2-1/2 IN. (63 MM) CLEARANCE TO CONNECT TUBING STRAIGHT TO
CONNECTOR. IF CLEARANCE IS LESS THAN 2-1/2 IN. (63 MM),
USE AN ELBOW CONNECTOR.
2
ALLOW 1-3/8 IN. (35 MM) MINIMUM CLEARANCE TO REMOVE VALVE.
1/2 IN. O.D. X 45° SAE FLARED TUBE CONNECTORS (2) (NOT FURNISHED)
USE 1/2 IN. (6 MM) O.D. COPPER TUBING
OUT
IN
M18349
Fig. 2. VP527A connectors and copper tubing dimensions in. (mm).
TYPICAL OPERATION An increase in control air pressure moves the valve stem toward the closed position, modulating flow through the valve. CONTROL AIR
VP527A
N.O.
SYSTEM SUPPLY
M18350
Fig. 3. VP527A typical operation.
Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley, MN 55422
95-5555EF J.H. Rev. 1-02
Honeywell Limited-Honeywell Limitée 35 Dynamic Drive Scarborough, Ontario M1V 4Z9 Printed in U.S.A. on recycled paper containing at least 10% post-consumer paper fibers.
customer.honeywell.com
Vanne pneumatique à eau VP527A NOTICE D’INSTALLATION
AVANT D’INSTALLER CE PRODUIT… Il faut s'assurer qu«il y a suffisamment d'espace pour l'entretien et le démontage de la vanne. Voir la Fig. 1. Cette vanne peut être installée dans n'importe quelle position. L'eau doit s'écouler dans le sens indiqué par la flèche sur le corps de la vanne.
RACCORD D'AIR POUR UNE CANALISATION EN PLASTIQUE DE 6 MM (1/4 PO) DIAM. EXT.
1
57 (2-1/4) DIAM.
38 (1-1/2)
INSTALLATION 1. 2.
97 (3-13/16)
Monter la vanne. Voir les Fig. 1 et 2. Raccorder la canalisation d'air de commande.
41 (1-5/8)
REMARQUE : Il n'y a ni étalonnage ni réglage à effectuer. 35 (1-3/8) 2
79 (3-1/8)
2
RACCORD DE 12 MM (1/2 PO) ÉVASÉ À 45° SAE (2 - NON FOURNIS) 1
LAISSER UN DÉGAGEMENT MINIMAL DE 38 MM (1-1/2 PO) POUR L'ENTRETIEN DE LA VANNE ET DE 63 MM (2-1/2 PO) POUR LE RACCORDEMENT DIRECT DE LA CANALISATION AU RACCORD D'AIR. SI LE DÉGAGEMENT EST INFÉRIEUR À 63 MM (2 1/2 PO), UTILISER UN COUDE.
2
LAISSER UN DÉGAGEMENT MINIMAL DE 35 MM (1-3/8 PO) POUR RETIRER LA VANNE.
MF18348
Fig. 1. Encombrement de la vanne VP527A en mm (po).
2 RACCORDS ÉVASÉS À 45° SAE DE 6 MM (1/2 PO) DIAM. EXT. (NON FOURNIS)
UTILISER UNE CANALISATION EN CUIVRE DE 6 MM (1/2 PO) DIAM. EXT.
SORTIE
ENTRÉE
MF18349
Fig. 2. Encombrement de la canalisation en cuivre et des raccords de la VP527A en mm (po).
FONCTIONNEMENT TYPE Une augmentation de la pression d'air de commande fait déplacer la tige de la vanne vers la position de fermeture, modulant ainsi l«écoulement dans la vanne. AIR DE
COMMANDE
VP527A
SYSTÈME D'ALIMENTATION
N.O.
MF18350
Fig. 3. Fonctionnement type de la VP527A.
Solutions de régulation et d’automatisation Honeywell 1985 Douglas Drive North Golden Valley, MN 55422
direction as the arrow cast on the valve body. INSTALLATION. 1. ... M18350. Fig. 3. VP527A typical operation. Automation and Control Solutions. Honeywell.
COVER FASTENER. BEFORE INSTALLATION. This normally-open, single-seated, straight-through, pneumatic valve provides two-position or proportional control .... 35 Dynamic Drive. Golden Valley, MN 55422. Scarborough, Ontario. M1V 4Z9. 95-5544EFâ1 B.B.
See Fig. 1 for typical piping and Fig. 2 for space. 1-1/2 (38). 1. MIN. ... Fig. 1. Typical piping. H. MINIMUM FOR. REMOVAL OF VALVE. VALVE. SIZE ... COMMON.
End Connections: NPT threaded inlet; male union outlet. Flow Characteristics: Modified ... ANGLE Å MALE. UNION OUTLET. M16449A. 1-1/2 in. (38 mm) MINIMUM CLEARANCE TO REMOVE. ACTUATOR. 2 1/2 in. (63 mm) MINIMUM CLEARANCE. TO FACILITATE .... RACCORDE
Maximum Safe Air Pressure: 30 psi (207 kPa). Maximum ... assembly with 1/8 in NPT air connection and push-in retainer to .... 480 Sawgrass Corporate Parkway.
35 Dynamic Drive. Golden Valley, MN 55422. Scarborough, Ontario. M1V 4Z9. Printed in U.S.A. on recycled. 95-5547EF J.H. 3-02 paper containing at least 10%.
ON-VEHICLE INSPECTION. 1. INSTALL LSPV ... When inspecting the fluid pressure, inspect the left front and right rear together, and the right front and left.
An optional 14003638-001 mounting kit is available for direct mounting to ... (25mm) to the second hole. ... mier trou et un deuxième trou, à 25 mm (1 po) du pre-.
Using an appropriate-sized socket and plastic mallet, lightly tap the valve retainer to loosen the valve keep- ers before installing the valve spring compressor.
water earth. Faizaan Peerzada. 25-F/3, Block D, National Homes,. New Muslim Town, Lahore - ... also given a sense of achievement to. Faizaan as an artist both ...
mier trou et un deuxième trou, à 25 mm (1 po) du pre- mier. Voir la Fig. 1. 2. Percer des trous pour des vis de montage n o 8, non fournies. REMARQUE : Dans le ...
obtained locally. NOTE: The RP418 and RP818 are functional replacements for the RP417 and RP817. Note the difference in location of ports 1 and 2. 2-3/4. (71). 3-3/4 .... 96 (3-3/4). RP418A, C ET RP818A. 42 (1-5/8). RP418B; RP818B. 25 (1). 16 (5/8).
Enfoncez la gâchette et placez environ 5 c.c. d'huile d'outil pneumatique dans ... la pressione massima di esercizio dell'utensile ad aria compressa (90 PSI).
earlier, with the air velocity at the material feed point being particularly important. ...... Fluid Mechanics for F^ngineering Students - 4th Ed. Edward Arnold. 1975.
It is not easy to express mathematically the relationship between the bed depth ... mp. = K} phh2 (b g phSina~K2). ----. (2) where PA = bulk density of material.