10 GigaBit Inline Regeneration Tap™ with SFP+ Monitor Ports

Monitoring Ports: (16) SFP+ cages (SFP+ modules are sold separately) ... These 10 GigaBit Regeneration Taps have SFP+ monitor ports so they can attach to ...
503KB taille 70 téléchargements 156 vues
10 GigaBit Inline Regeneration Tap™ with SFP+ Monitor Ports Multimode and Singlemode Fiber

Splitter:

Net Optics 10 GigaBit Regeneration Taps solve the key physical layer challenges of multi-device monitoring for 10 Gigabit networks. For a complete picture of network health, these Taps connect up to eight different network management and security devices at any single 10 Gigabit network location.

Fiber Optic Interface:

Keep your intrusion detection and prevention systems, protocol analyzers, RMON probes, and other security devices productive with a single Regeneration Tap. Maximize resources and save on access points when multiple devices can monitor the same traffic simultaneously through a single Regeneration Tap. These 10 GigaBit Regeneration Taps have SFP+ monitor ports so they can attach to monitoring equipment with any type of interface: singlemode fiber, multimode fiber, and copper. Just plug in the appropriate SFP+ transceiver modules for as many and whatever types of tools you want to connect. (1G SFP transceivers are not supported; the Regeneration Tap does not perform data rate conversion.) Without an IP address, monitoring devices are isolated from the network, dramatically reducing their exposure to attacks. However, the monitoring device connected to the Tap still sees all full-duplex traffic as if it were inline, including Layer 1 and Layer 2 errors. For extra uptime protection, Net Optics Taps offer redundant power connections. Should the primary power source fail, the Tap automatically switches to the backup power source. Power LEDs on the front of the Tap indicate the current power.

Technical Specifications: Split Ratio: 50/50, 70/30 Multimode: Corning 62.5µm or 50µm, wavelength 850nm (SR) Insertion Loss (network port): 4.5 dB max Singlemode: Corning 8.5µm, wavelength 1310nm (LR) Insertion Loss (network port): 3.7 dB max Laser: Class I, eye-safe, laser emitter type. These Class I Lasers conform to the applicable requirements per US 21 CFR (J) and EN 60825-1, also UL 1950 applications.

Performance:

Drops: No packets dropped from 0 to 10 Gbps Average Latency: 20 nanoseconds

Environmental:

Temperature: 0ºC to 40ºC (Operating), -10ºC to 70ºC (Storage) Relative Humidity: 10% min, 95% max, non-condensing

Mechanical:

Dimensions: 1.75" high x 13" deep x 17" wide, Weight: 5 lbs

Electrical:

Redundant Power Supplies, each: Input: 100-240VAC, 0.5A, 47-63Hz DC Input: -48VDC nominal, -36 to -72VDC, 1A Power Consumption: 45W

Connectors:

Monitoring Ports: (16) SFP+ cages (SFP+ modules are sold separately) Network Ports: (2) LC connectors

Passive, Secure Technology

Certifications:

• Provides complete full-duplex visibility at 10 Gbps without data stream interference or introducing a point of failure

Part Number Description RG-830X Regen Tap, 8x1 GigaBit Inline MM 62.5µm 50:50 RG-833X Regen Tap, 8x1 GigaBit Inline MM 62.5µm 70:30 RG-840X Regen Tap, 8x1 GigaBit Inline MM 50µm 50:50 RG-843X Regen Tap, 8x1 GigaBit Inline MM 50µm 70:30 RG-850X Regen Tap, 8x1 GigaBit Inline SM 8.5µm 50:50 RG-853X Regen Tap, 8x1 GigaBit Inline SM 8.5µm 70:30 Add -DC to the part number for the -48VDC model.

• Enables real-time monitoring of a single 10 Gigabit link with up to 8 monitoring devices

• Passes all traffic—including errors—from all layers for comprehensive troubleshooting • No IP address is needed for the Tap or monitoring device, enhancing security • Redundant power ensures monitoring uptime

Ease of Use

• LED indicators show redundant power, speed, link, and activity status • Front-mounted connectors support easy installation and operation • No custom analyzer cables—each half-duplex data stream has its own connector • Compatible with all major manufacturers’ monitoring devices, including protocol analyzers, probes, and intrusion detection systems Net Optics® is a registered trademark of Net Optics, Inc. Copyright 1996-2010 Net Optics, Inc. All rights reserved. Additional company and product names may be trademarks or registered trademarks of the individual companies and are respectfully acknowledged. PUBRG830XD Rev. B, 09/11

MET (UL), CE, FCC, VCCI, C-Tick, RoHS, WEEE, IEEE 802.3 compliant

SFP+ Transceiver Kits SFP+KT-SR 10G Fiber SR SFP+ Transceiver with cable SFP+KT-50SR 10G Fiber SR 50um SFP+Transceiver with cable SFP+KT-LR 10G Fiber LR SFP+ Transceiver with cable SFP+ transceivers are required for operation and are sold separately

Warranty

All Net Optics products come standard with a 1 year manufacturer’s warranty. Additional Service Plan options to extend warranty coverage are available for purchase.

GigaBit Inline Regeneration Tap™ with SFP Monitor Ports Multimode and Singlemode Fiber

Splitter:

Net Optics GigaBit Regeneration Taps solve the key physical layer challenges of multi-device monitoring for Gigabit networks. For a complete picture of network health, these Taps connect up to eight different network management and security devices at any single Gigabit network location.

Fiber Optic Interface:

Keep your intrusion detection and prevention systems, protocol analyzers, RMON probes, and other security devices productive with a single Regeneration Tap. Maximize resources and save on access points when multiple devices can monitor the same traffic simultaneously through a single Regeneration Tap. These GigaBit Regeneration Taps have SFP monitor ports so they can attach to monitoring equipment with any type of interface: singlemode fiber, multimode fiber, and copper. Just plug in the appropriate SFP transceiver modules for as many and whatever types of tools you want to connect. Without an IP address, monitoring devices are isolated from the network, dramatically reducing their exposure to attacks. However, the monitoring device connected to the Tap still sees all full-duplex traffic as if it were inline, including Layer 1 and Layer 2 errors. For extra uptime protection, Net Optics Taps offer redundant power connections. Should the primary power source fail, the Tap automatically switches to the backup power source. Power LEDs on the front of the Tap indicate the current power.

Passive, Secure Technology

• Enables real-time monitoring of a single Gigabit link with up to 8 monitoring devices • Provides complete full-duplex visibility at 1 Gbps without data stream interference or introducing a point of failure • Passes all traffic—including errors—from all layers for comprehensive troubleshooting • No IP address is needed for the Tap or monitoring device, enhancing security • Redundant power ensures monitoring uptime

Ease of Use

• LED indicators show redundant power, speed, link, and activity status • Front-mounted connectors support easy installation and operation • No custom analyzer cables—each half-duplex data stream has its own connector • Compatible with all major manufacturers’ monitoring devices, including protocol analyzers, probes, and intrusion detection systems Net Optics® is a registered trademark of Net Optics, Inc. Copyright 1996-2010 Net Optics, Inc. All rights reserved. Additional company and product names may be trademarks or registered trademarks of the individual companies and are respectfully acknowledged. PUBRG830D Rev. B, 09/11

Technical Specifications: Split Ratio: 50/50, 70/30 Multimode: Corning 62.5µm or 50µm, wavelength 850nm (SX) Insertion Loss (network port): 4.5 dB max Singlemode: Corning 8.5µm, wavelength 1310nm (LX) Insertion Loss (network port): 3.7 dB max Laser: Class I, eye-safe, laser emitter type. These Class I Lasers conform to the applicable requirements per US 21 CFR (J) and EN 60825-1, also UL 1950 applications.

Performance:

Drops: No packets dropped from 0 to 1 Gbps Average Latency: 20 nanoseconds

Environmental:

Temperature: 0ºC to 40ºC (Operating), -10ºC to 70ºC (Storage) Relative Humidity: 10% min, 95% max, non-condensing

Mechanical:

Dimensions: 1.75" high x 13" deep x 17" wide, Weight: 5 lbs

Electrical:

Redundant Power Supplies, each: Input: 100-240VAC, 0.5A, 47-63Hz DC Input: -48VDC nominal, -36 to -72VDC, 1A Power Consumption: 45W

Connectors:

Monitoring Ports: (16) SFP cages (SFP modules are sold separately) Network Ports: (2) LC connectors

Certifications:

MET (UL), CE, FCC, VCCI, C-Tick, RoHS, WEEE, IEEE 802.3 compliant Part Number Description RG-830 Regen Tap, 8x1 GigaBit Inline MM 62.5µm 50:50 RG-833 Regen Tap, 8x1 GigaBit Inline MM 62.5µm 70:30 RG-840 Regen Tap, 8x1 GigaBit Inline MM 50µm 50:50 RG-843 Regen Tap, 8x1 GigaBit Inline MM 50µm 70:30 RG-850 Regen Tap, 8x1 GigaBit Inline SM 8.5µm 50:50 RG-853 Regen Tap, 8x1 GigaBit Inline SM 8.5µm 70:30 Add -DC to the part number for the -48VDC model. SFP Transceiver Kits SFPKT-SX GigaBit Fiber SX SFP Transceiver with cable SFPKT-50SX GigaBit Fiber SX 50um SFP Transceiver with cable SFPKT-LX GigaBit Fiber LX SFP Transceiver with cable SFPKT-CU3 10/100/1000 Copper Transceiver with cable SFP transceivers are required for operation and are sold separately

Warranty

All Net Optics products come standard with a 1 year manufacturer’s warranty. Additional Service Plan options to extend warranty coverage are available for purchase.

GigaBit Span Regeneration Tap™ with SFP Monitor Ports Multimode and Singlemode Fiber Net Optics GigaBit Regeneration Taps solve the key physical layer challenges of multi-device monitoring for Gigabit networks. For a complete picture of network health, these Taps fan out two switch Span ports to up to four different network management and security devices each. Keep your intrusion detection and prevention systems, protocol analyzers, RMON probes, and other security devices productive with a single Regeneration Tap. Maximize resources and save on access points when multiple devices can monitor the same traffic simultaneously through a single Regeneration Tap. These GigaBit Regeneration Taps have SFP monitor ports so they can attach to monitoring equipment with any type of interface: singlemode fiber, multimode fiber, and copper. Just plug in the appropriate SFP transceiver modules for as many and whatever types of tools you want to connect. Without an IP address, monitoring devices are isolated from the network, dramatically reducing their exposure to attacks. However, the monitoring device connected to the Tap still sees all full-duplex traffic as if it were inline, including Layer 1 and Layer 2 errors. For extra uptime protection, Net Optics Taps offer redundant power connections. Should the primary power source fail, the Tap automatically switches to the backup power source. Power LEDs on the front of the Tap indicate the current power.

Passive, Secure Technology

• Enables real-time monitoring of two switch Span ports with four monitoring devices each • Provides complete visibility at 1 Gbps without data stream interference or introducing a point of failure • Passes all traffic—including errors—from all layers for comprehensive troubleshooting • No IP address is needed for the Tap or monitoring device, enhancing security • Redundant power ensures monitoring uptime

Ease of Use

• LED indicators show redundant power, speed, module insertion • Front-mounted connectors support easy installation and operation • No custom analyzer cables—each half-duplex data stream has its own connector • Compatible with all major manufacturers’ monitoring devices, including protocol analyzers, probes, and intrusion detection systems Net Optics® is a registered trademark of Net Optics, Inc. Copyright 1996-2010 Net Optics, Inc. All rights reserved. Additional company and product names may be trademarks or registered trademarks of the individual companies and are respectfully acknowledged. PUBRG835D Rev. A, 10/10

Technical Specifications: Environmental: Temperature: 0ºC to 40ºC (Operating), -10ºC to 70ºC (Storage) Relative Humidity: 10% min, 95% max, non-condensing

Mechanical: Dimensions: 1.75" high x 13" deep x 17" wide, Weight: 5 lbs

Electrical: Redundant Power Supplies, each: Input: 100-240VAC, 0.5A, 47-63Hz DC Input: -48VDC nominal, -36 to -72VDC, 1A Power Consumption: 45W

Fiber Optic Interface: Laser: Class I, eye-safe, laser emitter type. These Class I Lasers conform to the applicable requirements per US 21 CFR (J) and EN 60825-1, also UL 1950 applications.

Connectors: Monitoring Ports: (16) SFP cages (SFP modules are sold separately) Network Ports: (2) LC connectors

Performance: Drops: No packets dropped from 0 to 1 Gbps

Certifications:

MET (UL), CE, FCC, VCCI, C-Tick, RoHS, WEEE, IEEE 802.3 compliant Part Number Description RG-835 Regen Tap, 8x1 GigaBit Span MM 62.5µm 50:50 RG-845 Regen Tap, 8x1 GigaBit Span MM 50µm 50:50 RG-855 Regen Tap, 8x1 GigaBit Span SM 8.5µm 50:50 Add -DC to the part number for the -48VDC model. SFP Transceiver Kits SFPKT-SX GigaBit Fiber SX SFP+ Transceiver with cable SFPKT-50SX GigaBit Fiber SX 50um SFP+Transceiver with cable GigaBit Fiber LX SFP+ Transceiver with cable SFPKT-LX SFPKT-CU 10/100/1000 Copper Transceiver with cable SFP transceivers are required for operation and are sold separately

Warranty

All Net Optics products come standard with a 1 year manufacturer’s warranty. Additional Service Plan options to extend warranty coverage are available for purchase.

ELEXO 20 Rue de Billancourt 92100 Boulogne-Billancourt Téléphone : 33 (0) 1 41 22 10 00 Télécopie : 33 (0) 1 41 22 10 01 Courriel : [email protected] TVA : FR00722063534