04

PRT 03/04 - 06. Air pressure sensors, 1.0 / 2.5 bar absolute. The PRT xx series devices are high-accuracy and reliability analogue absolute pressure sensors.
22KB taille 21 téléchargements 453 vues
PRT 03/04 - 06 Air pressure sensors, 1.0 / 2.5 bar absolute The PRT xx series devices are high-accuracy and reliability analogue absolute pressure sensors. Each pressure sensor exploits the piezoresistive properties of silicon devices. The sensing element is a Wheatstone bridge located on a mechanically-shaped silicon chip. A thick film hybrid circuit for signal amplifying is included in the same package. The same circuitry provides thermal compensation and noise reduction. These active devices are housed in hermetically sealed plastic protective casings.

Technical data Mechanical Characteristics Dimensions (maximum) .........76,5x65.0x32.0 Nozzle diameter ........................................4.7 Weight ...................................................42.0 Connector .....................................Mini-Timer

mm mm g 3 ways

Electrical Characteristics Power supply ..........................................5.00 Min pressure output (at 5 Vdc supply) .....0.25 Full scale output (at 5 Vdc supply) ..........4.75 Output impedance...................... less than 10

Vdc ±0.5 V V W

Performance Pressure range: PRT 03/04 .................................. 17 ÷ 105 kPa PRT 06 ....................................... 20 ÷ 250 kPa Operating temperature range.......... -40 ÷ 125 °C Response time ............................. less than 2 ms Accuracy (from nominal values) .................. 1 % f.s.o. (including non-linearity, hysteresis and repeatability) Over pressure.......................................... 200 %

PRT 03/04 Sensor output in mV

Ø5.2 +/- 0.2

4750 mV

V 4m .1 51

Pa /K

Pressure in PKa

Ø6.4

2500 mV

61.5

250 mV 17

105 KPa

61

35.0

4750 mV

A

B

V 6m .5 19

C

2500 mV

Pa /K

Pressure in PKa

PRT 06 Sensor output in mV

250 mV

32.0

50.0

20

135

250 KPa

Connector Pin Out PIN

description

A

+ 5 Vdc

B

GND

C

Signal OUT

A

B

C

Important wiring note: The connections A,B & C are identified as 1,2 & 3 on many commercially available minitimer connectors and may also be numerically / alphabetically reversed. Always check your loom connections against the sensor connector shown here.

Ordering Information Description PRT 03/04 PRT 06

Air Pressure Transducer 105 kPa (1.05 bar max) Air Pressure Transducer 250 kPa (2.5 bar max)

Order code 215810001604 215810001900

For further details please contact MM Competition Systems Ltd Unit 3, Old Station Business Park, Compton, Berkshire, RG20 6NE England 83800551000.doc 14/11/01

Tel: +44 (0)8707 444666 Fax: +44 (0)8707 444888 www.mmcompsys.com [email protected] Specification subject to change without notice

Section 7 / Page 1